Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
Closing Date
25 Mar 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHAILENDRA KUMAR SINGH,
SUPERINTENDING ENGINEER
IGIMS, PATNA
SHAILENDRA KUMAR SINGH,
SUPERINTENDING ENGINEER
Group - A Flicker fusion apparatus Digital Hand Dynamometer Digital Display Multiple Choice Apparatus Peg Board (Purchase and groove) and hand stabilometer Exercise physiology System with data acquisition system and Gas Analyzer Treadmill with exercise physiology system Master two steps Autonomic function test lab Platelet aggregometer 16-channel polygraph Portable Hand Held Doppler Atomic absorption Spectrophotometer Biochemical Autoanalyzer Fully automated cell counter Ice- lined refrigerator (ILP) / minus 20 degree Deep freezer UV-visible Spectrophotometer Kits and solvents Biosafety cabinet Cooling centrifuge CO2 incubator Culture plates and glasswares Autoclave Media filtration system Refrigerator Real Time PCR (RT-PCR) Autoclave Feed sterilizer Compound microscope with camera and recording system Table top anaesthesia system Individually ventilated cage (IVC) water purifier Portable USG machine Portable X-Ray Machine Enzyme multiplied Immunoassay technique Extraction equipment ? solid phase extractor, liquid phase, Protein Precipitation / Visualization Reagents and solvents Ice-Lined refrigerator / minus 20 degree Celsius freezer Semi-auto analyser (semi-automatic biochemical analyser
124983
NIT-35 / 2025-26 / Biomedical Eqpt/ IGIMS / Store
Open Tender
GENERAL
Patna
• Manufacturer or Authorized Agent of the Manufacturer
• Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
• Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
• Certificate towards market standing of minimum 05 years in the area of supply and or maintenance of bio-medical equipments.
• Certificate for sole ownership / partnership
• Statement of financial standing from bankers
• Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
• Notary certified User List (List of Govt./Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
• Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt./Semi Govt.//Reputed Pvt. Institutions/organization for the quoted items. ( same model)
• Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the deptt. or Institution after a minimum period of six months of installation
• Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
• Whether rates quoted are inclusive of all taxes or not.
• Whether rates are quoted as per format mentioned in the Bidding Document or not.
• Affidavit to the effect that the bidder is not
blacklisted by any Govt. agency or have no pending case either Civil or Criminal against them.
• Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. / Pvt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
• Quality Assurance Certificate like ISI, ISO-9002, IP/BP, CE, FDA (US) or any other (please specify)
• Bid Security amount deposited is enclosed or not. If yes, please mention the details.
• Original Technical Catalogue of the quoted model
• Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of three years including all spares, accessories, consumables etc., (Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
• Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document.( Clause No- 13 of ? Instruction to Bidder ? & clause no- 3, 4 and 5 of Condition of contract.)
• Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing? Complied shall not be accepted.
• PAN and copies of Income Tax Returns for the last three years.
• Duly attested copy of sales tax/Vat registration certificate
• Compliance Statement with relation to the terms & conditions as mentioned in the document.
• Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of five years after expiry of warranty period of five years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
GENERAL
ITEM RATE
L1
1
27 documents required · 27 mandatory
₹2,500
Processing Fee: 590
In the Conference Room of Superintending Engineer at ground floor of New Administrative Building.
13 Feb 2026
13 Feb 2026
27 Mar 2026
13 Feb 2026
25 Mar 2026
13 Feb 2026
24 Feb 2026
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipt /IGIMS/Store
A.: To be filled by the bidder and submitted along with the Technical Bid.
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Status of Bidder:
· Manufacturer or Authorized Agent of the Manufacturer
· Whether Public Undertaking, Public Ltd., Private Ltd. Company or Proprietary Firm/partnership firm
(Please attach Notary certified MANUFACTURER’S AUTHORISATION FORM as per FORMAT placed at Annexure – III)
2 Power of Attorney as per Annexure - V in favour of person to sign, submit and negotiate the bid.
3 Certificate towards market standing of minimum 05 years in the area of supply and or maintenance of bio-medical equipments.
4 Certificate for sole ownership / partnership
5 Statement of financial standing from bankers
6 Statements of turnover per year for last three successive years duly certified by the Chartered Accountants.
7 Notary certified User List (List of Govt.
/Semi Govt., Reputed Pvt. Hospital) where quoted model of the items has been supplied and installed.
8 Notary certified Supply order copy (Minimum 3nos. or more) issued by Govt./Semi Govt.//Reputed Pvt. Institutions/organization for the quoted items. ( same model)
9 Notary certified Performance certificate of the same supplied machine (of quoted make and Model) issued by Head of the deptt. or Institution after a minimum period of six months of installation
10 Prerequisite (if any) for installation of the Machine, if any, to be provided by the Institute.
11 Whether rates quoted are inclusive of all taxes or not.
12 Whether rates are quoted as per format mentioned in the Bidding Document or not.
13 Affidavit to the effect that the bidder is not
blacklisted by any Govt. agency or have no pending case either Civil or Criminal against them.
14 Affidavit, to the effect that the bidder is not supplying the quoted item(s) to any other Govt. / Pvt. Organizations / Institutions / Hospitals at the rate lower than the rate quoted against this tender.
15 Quality Assurance Certificate like ISI, ISO-9002, IP/BP, CE, FDA (US) or any other (please specify)
16 Bid Security amount deposited is enclosed or not. If yes, please mention the details.
17 Original Technical Catalogue of the quoted model
18 Certificate, to the effect that bidder will maintain the quoted item(s) during Warranty period of five years including all spares, accessories, consumables etc.,
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement)
19 Certificate, to the effect that bidder has quoted its rate for Comprehensive Annual Maintenance Contract inclusive of labour, spares, consumables, accessories etc. on per year basis for a further period of five years after expiry of warranty period of five years in the price bid.
(Please mention the name of the item / items with price, which are not supplied by the bidder free of cost with frequency of replacement during Comprehensive Annual Maintenance Contract period in the price bid)
20 Acceptance of all terms / conditions towards after sales / services as mentioned in the bidding document.( Clause No- 13 of “ Instruction to Bidder “ & clause no- 3, 4 and 5 of Condition of contract.)
21 Compliance Statement with relation to the technical specification as mentioned in the bidding document duly supported by the original catalogue. The bidder must quote specification in the compliance column Mere writing” Complied shall not be accepted.
22 Compliance Statement with relation to the terms & conditions as mentioned in the document.
23 PAN and copies of Income Tax Returns for the last three years.
24 Duly attested copy of GST registration certificate.
B: To be filled by the Bidder and submitted along with Price Bid
Sl. No. Terms & Conditions as per Bidding Document Page No. Remarks
1 Item wise price for the item(s) as mentioned in the Bidding Document and as per format attached as Annexure – I(a) or I (b)
2 Rate for Comprehensive Annual Maintenance Contract as per terms & conditions mentioned in the Bidding Document and as per format attached as Annexure - II
Note: If the above-tender details are not mentioned and required documents are not attached at appropriate places, the offer of the bidder(s) shall be summarily rejected. Hence, bidder(s) are advised to go through the bidding document carefully and tender be prepared with all the required documents to avoid rejection of offer.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipt /IGIMS/Store
ELIGIBILITY CRITERIA Mentioned Page no.
1 Manufacturers or their authorized dealers/Indian subsidiaries/direct importers having a place of business in any of the States of India are eligible to participate in this tender.
2 The bidder and manufacturer of the equipment offered should be in the business of the supply and installation of same / similar equipment for the last five calendar years.
3 (a) The manufacturer should have completed at least 05( Five ) nos. installations of the quoted items in Govt. /Pvt. Institutions /Hospitals in India. The installations mentioned by the manufacturer in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
(b) The bids quoted as the authorized representative of the manufacturer meeting the above criteria 02 (a) should have also supplied and installed at least 03( Three) nos. installations of the quoted items in Govt. /Pvt. Institutions/ Hospitals in India in last five years from the last date of submission of tender. The installations mentioned by the authorized representative in their offer must be functional and performance certificate for the same issued by the user concerned also be attached with the offer.
4 The Bidder should be public undertaking /Autonomous Body /Public Ltd./Pvt. Ltd. Company or proprietary firm /Partnership Firm and should be in medical equipment business since last five years in India. The Bidders having manufacturing facility in their name in India for the majority of the items offered by them shall be given preference.
5 The Bidder (manufacturer or their authorized agent) should have had average annual financial turnover of Rs. 50 Lakh during the last three years ending s 31st March 2024.
6 Bidders who have the capability to attend repairs of these equipment within the time mentioned in this bidding document and who are willing to provide stand by equipment or replace the faulty equipment if the repair/down time extends beyond 72 hours from the time of reporting of the fault within the next 48 hours (total down time should not exceed 5 days in one instance). The bidders who have the capability to ensure the uptime mentioned in this document (Documentary proof shall be submitted on the after sales facilities and expertise of the bidder.)
7 Bidders are not offering the equipment of a firm /company that has
been blacklisted by Indira Gandhi Institute of Medical Sciences – Patna or blacklisted/debarred by any other State / Central Government's organization.
Note: Notwithstanding anything stated above, the Institute reserves the right to assess the Bidder’s capability and capacity to perform the contract satisfactorily before deciding on award of contract, should circumstances warrant such an assessment in the overall interest of the purchaser.
The Institute reserves the right to ask for a free demonstration of the quoted equipment at a pre determined place acceptable to the purchaser of technical acceptability as per the tender specification, before the opening of the price tender.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (1)
SI. NO. Specification of Flicker fusion apparatus
1 · Includes viewing Chamber, AC adapter, hand-held response switch
2 · Power Supply
3 o AC/DC Wall mount adapter 5V 5W with USB 1.1 Cable A Male to B Male 4.92 feet Shielded
4 o Computer USB port
5 · Frequency: 1.0 to 100.0 Hz in 0.1 Hz increments with an error of 0.05%
6 · Slide Holder: 2 x 2 in 35 mm holder for optional neutral density filters with 0.5% to 50% light transmission
7 · Auto Mode Ramp Rates: Options of 0.5, 1, 2, and 4 Hz per second
8 · External Response: SPDT normally open hand-held switch with 3.5 mm stereo plug
9 · Typical Maximum Luminance: 58 Cd/m2
10 · Viewing Angle: 1.9 degrees
11 · Light/Dark Ratio: 1:1
12 · Stimulus Colour: White
13 · Viewing Chamber Colour: Black
14 · Viewing Chamber Mask: should obstruct external light and made of material non-toxic to skin
15 · Viewing Chamber:
16 o Approx. dimensions: 7 x 19 x 16 inches (L x W x H)
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (2)
SI. NO. Specification of Digital hand dynamometer
1 Designed for forearm,wrist,and hand strengthevaluation and training
2 Indicator:Embedded
3 Capacity:Diverse measuring capacity that can be setup to20,40,80,100kg by changing springs or changing settings
4 Graduation: 100
5 Differentmodesshouldbeavailableinthesetting
6 Maxmodeshould beavailablefor recordthemaximumgrip force
7 AVGmodeshouldbeavailabletoaveragegripforceofrighthandandlefthand
8 Handleeasilyadjuststo different(preferablyfive)grippositions
9 Poweroptionshouldbewithbatteriesaswellaswithpowercord adapter
10 Manualwithdetailedinstructionsanddemonstrationofperformancetobeprovided before procurement and installation
11 AMC,CMCandtechnicalsupportforatleast3 years
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (3)
SI. NO. Specification of Digital display Multiple Choice Apparatus
· MultipleChoiceReactionTimeApparatus
· Reactiontimeunitdesignedforgettingresponsetodifferentauditoryandvisual stimuli.
· ContainsaMasterControlwhichcontainsa1/100seconddigitalclock,pre-stimulus intensity control, variable cue-stimulus delays, a stimulus selector and a response selector;
· IncludesaResponseUnitwithatleastthreetelegraphkeysandauxiliary;afourmode Stimulus Unit with a 1-second cue light, at least three colored stimulus light (red, green, blue), and auditory 2800 Hz Sonalert, and auxiliary; a Slide Viewer; and electronic Voice Reaction-Timer Control
· Accessories:deskmike,throatmike,pushbuttonbox,andallthenecessarycables and connectors, power cords, etc.
· LineVoltage:105/125VAC50/60Hz
· MinimumReactionTime:1/100second
· MaximumReactionTime:999.99seconds
· AuxiliaryStimulus: 6 voltsAC to1 amp
· Displayshouldpreferablybedigital
· AMC,CMCforatleast3yearswithallnecessarytechnicalsupport
· Demonstrationoffunctionshouldbedisplayedbeforeprocurementandinstallation
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (4)
SI. NO. Specification of PegBoard/Hand Stabilometer
Thewholesystemconsistsofthreepartsasdetailedbelow; all three parts withall necessary accessories should be provided to complete the set-up:
(1) PurduePegBoard
· Theinstrument similartoPurduepegboard
· Rectangularboardwith2setsof25holesrunningverticallyand4concavecupsatthe top
· approximately30inchestall
ü Smallmetal pegs/pins50in numbers
ü Washers50innumbers
ü Collars50in numbers
· Technicalsupportandsupplyofextraaccessories,ifnecessary,evenafter procurement/installation
(2) GroovedPegBoard
· GroovedPegboardfor complexhandmanipulationanddexteritytest
· Groovedpegboardmanipulativedexteritytestinstrumenttocontain25holeswith randomly positioned slots.
· Pegswitha“key”alongoneside mustberotatedto matchholebeforeinserted.
· Thetest requiresmorecomplexvisual-motor coordination
· Shouldmeasureperformancespeed ina finemotor task
· Accessories:atleast50 pegswith“keys”, andexaminer’smanualwithnorms
· Demonstrationoffunctionbeforeprocurementandinstallation
· Technicalsupportandsupplyofextraaccessoriesasnecessaryevenafter procurement/installation
(3) Hand steadiness tester
· Electricaldevicelikeaboxwithmultipleseriallyarrangedholesofdecreasing diameter with Impulse Counter with Manual
· Devicetoexaminethesteadinessofthehandandthe fingers
· Holesarrangedsystematicallyindecreasingorderofdiametersothattheyproceed from the widest to the smallest
· Atleast9 holeswith greatestdiameterofapprox. 12 mmtothesmallestof approx.2.5 mm
· Electricallyconnected stylus
· Impulsecounterattachedtothesystemthatindicatetouchwiththesurfaceofthebox with the stylus
· Accessories: Power cord and all connectors, etc.
· Manualwithdetailedinstructionsforoperation
· AMC,CMCforatleast3yearswithallnecessarytechnicalsupport
· Demonstrationoffunctionbeforeprocurementandinstallation
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (5)
SI. NO. Specification of Exercise Physiology system with data acquisition system and Gas Analyser
A. The Data Acquisition & Analysis software
· Thesystemshouldhave at-least32channelsforrecording
· TheDatarecorder shouldhaveaHighsampling rate of100KHzor more.
· ADC resolution of 16 bits on all gain ranges and variable sampling speed on each channel with continuously record and display up to 32 channels of data.
· Shouldbecapabletopoweravailableexternaldevicesofupto350W
· System should be able be powered from mains, laptop or portable battery pack for increased portability in different experimental setups.
· ThesystemshouldmeasureVO2, VCO2, RQ, VE, spirometry/flowvolume, etc.
· The system should supply with Branded Compatible Desktop Computer i7 12th Generation,preferably 16GB RAM,512GB SDD and 1TBHDD,genuinein-built Windows 11, in-built genuine MS office, Wi-Fi Bluetooth with LED 27 inch Monitor, coloured Laser printer.
· Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabiliser
· Toplotrealtimeflow&volumeloops
· Facility for ECG (lead I, II, III, aVL, aVF, aVR and VI to V6) for real time vectorcardiographyanalysistoevaluatethemagnitudeanddirectionofcardiacaxis during exercise.
· ShouldhaveanoisefreewirelessmultichannelECG,R-Rinterval,HeartRate,Skin temp,GSR,Respirationrate,SPO2,PPGAccelerometeractivityintegratedintothe system.
· The range of wireless parameters should be 100 meters or above for real time recording and also have logging mode as well.
· Bothwiredandwirelessmodulesshouldrecordandanalysesimultaneouslyaswell individually on same software.
· Thesystemshouldproviderealtimedatarecordingwithonlineandofflineanalysis.
· Thegraphsandreportcan besimplecustomizationandprinting option
· Online data streaming to MS Excel and MATLAB and Editable macros for customization
· Should have software-controlled filtering High Pass, Low Pass filters, AC Coupling, Digital filters, band pass filter & Main filters.
· The software should have built in smart analysis features like RMS, power spectrum, template matching, curve fitting, cross correlation etc.
· Export formats should allow export Binary, IGOR, MATLAB, QuickTime, Wav, Text, Excel etc.
· Online Cyclic Measurements tools: Rate, period, frequency, count, minimum, maximum, height, integral, variance, derivative, Arithmetic & mathematic formulae.
· Thesoftwareshould haveanalysis modules ECG, HRV, PeakAnalysis, Metabolic analysis, video monitoring etc.
· Facility to perform online and offline complete heart rate variability analysis (Time & Frequency domains), ECG interpretation, PQRST amplitudes and ST elevation analysis.
· The gas analysis metabolic software should automatically generate the VO2 oxygen consumption, VCO2 carbon dioxide production, VE Expired minute volume , RER respiratory exchange ratio, ECG, HRV, Body Temperature and Pressure Saturate BTPS, Standard Temperature and Pressure Dry STPD, (VE / VO2),(VE/VCO2)etc.andshouldgeneratesanumberofMetabolicgraphsand report for easy interpretation.
· Softwareupdateandupgradesshouldbeprovidedforatleastnext5 years.
· Onsitetrainingfromthecompanyexpertsshouldbeprovided.
· Itshouldsuppliedwithallthenecessarycompatibleaccessories, transducers, cables and consumables like leads, etc.
B. GasAnalyserO2and Co2
· Shouldhavehighlysensitiveoxygenandcarbondioxidesensorwithadequate variable flow range for best performance and results.
CO2 Sensor: O2 Sensor
Type: Infrared, optical absorption:Type: Visible spectrum (760nm) Range: 0-
10% CO2:Range: 0-100% O2
Linear Output: 0-1V (0-10% CO2): LinearOutput: 0-1V (0-100%O2)
Resolution: 0.1% CO2: Resolution: 0.01% O2
· The Gas analyser should have with a pump controller on/off switch, a gas sampling port and a dial for selecting variable pump sampling rates (approx.35to 200 mL/min).
· The system should simultaneously record and analyse all the required parameter in a single screen for interpretation and computation of results.
· Thesystemshouldbeprovidedwithphysicalmixingchambersuitablefor extremely high and low ventilation ranges.
· Accessories: -. Mouthpiece, head gear, tubing and flow sensors, mixing chamber connectors, ECG electrodes, cream, paste, filters and Douglas bags to be provided.
· In addition,compatible accessories including tubing, cables, transducers for small animals, like rats and mice should be provided
· Thegasanalysershouldbeable toworkwithrat and mice.
· Free Software upgrades and updates should be provided for next 5 years.
C. Bicycle Ergometer
· Bi-cycle ergometer should be supplied or interfaced with a compatible Brake systemmicroprocessor-controllededdycurrentbrake,Speedrange30 -100rpm
· Loadupto1000-Watt,speedindependent
· Adjustmentofhandlebarsinclination:360°andAdjustmentofsaddleheight continuous, mechanic
· Patient weight (max.)160kg
· ThecontrolunitmusthaveDisplay/patientdisplayload,rpm,speed,time,blood pressure, heart rate (LCD) / rpm (LED), Keyboard, Graphic display (load, heart rate)
· Interfaceupgradableoption forBloodpressureandSp02 preferable
· SeamlesslyInterfacesviaCOM
· AMC,CMCandtechnicalsupportfor5 years
· Treadmillshouldbeoperatingautomaticallywiththehelpofcomputerforhuman.
· TreadmillinterfacetothecomputershouldbeRS232.
· Treadmillshouldoperateonmains230V50Hz12Amp.
· Treadmillwalkingareashouldbeatleastwidth500mm,length1400mm.
· TreadmillspeedcontrolshouldbeVariable.
· Treadmillelevationcontrolshouldbe variable.
· Treadmillshouldtakepatientloadupto150Kgs.
· Thesystemshouldbecompatiblewiththedataacquisitionsystemasprovidedandthe GasAnalyzer
· ThedataincludingECGetcshouldbenoise-free
· CompatibleECGleads,transducer,cablesandnecessaryaccessoriesshouldbe provided
· AMC,CMCandtechnicalsupportfor5 years
E. Documentation&Certification
· ManufacturershouldhaveISOcertificationforqualitystandards.
· ShouldbeCE/USFDA/IEC/BISothersafetystandardsapproved product.
· Demonstrationoftheequipment’sandnecessarytrainingtobeprovidedbythe exports if required.
· ManufacturershouldhaveexperienceofManufacturing&Installationofthe quoted product for at-least 05 years. Documentary proof should beattached.
· Warranty5years
· CMC,AMC for a tleast 5 years with all technical support should be provideds
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (6)
SI. NO. Specification of Treadmill with exercise physiology system
· Exercisetreadmillforratshouldallowanimaltoexercisewithinanisolated space.
· It should have an exercise belt, associated pulleys and stimuli are enclosed in a compartment which should be made air-tight.
· Itshouldhaveanopen-flowcalorimetertothecompartmenttocreateacompletesystem for the measurement of respiratory metabolic performance while exercising.
· It should have the facility to incorporates an electric motor and speed controller to which one to seven additional slave units can be connected for exercising multiple animals.
· Incline of animal compartment is adjustable in 5° increments with exercise lane dimension should bot be more than 384mmX 51mmX102mm.
· Electrical stimulus grid is available each exercise lane and can be activated manually by the operator and led lamps should indicate when electrical stimulus grid is active.
· Theintensityofelectricalshockshouldbealsooperatoradjustablefrom0.35mAto 1.5mA.LEDlamps indicatewhich electricalstimulus gridis active
· Animal compartment should offer with air-tight seals for measuring oxygen consumptionduringanimalexercisebywayofanattachedopencircuitcalorimeterfor the measurement of VO2, VCO2, RER,
· Systemshouldbeabletomeasuretheexchangeofcarbondioxideforoxygenisknown as indirect calorimetry. The ratio of the exchange varies depending on if the animal is metabolizing fat, carbohydrate, protein, or a mixture of the three.
· Totalsettletimewithmeasuretimeforgassensorsshouldnotbeexceedingonehundred twenty seconds per minute.
· Sampleairdrawnfromeachcageshouldbedriedthroughadesiccatingdevicewithout coming into contact with any chemical drying agent.
o OxygenSensor:
· Range:18.9% to21.2%Resolution: 0.002%O2 with resolutionof 0.01 ppm
· SensorAccuracy: +/-0.001%of reading
· Drift:lessthan0.25%O2/ 24 Hours
· ItisdesirabletohaveElectrochemicalSensorfor higher accuracy.
· CarbondioxidegasshouldabsorbIRlightataveryspecificwavelengthandthesample air will passed through the sensor, an IR emitter should emits a known amount of IR light and the amount absorbed by the sample should be recorded by the detector.
o CarbonDioxideSensor:
· Range:0%-0.8%Resolution:0.002%CO2
· SensorAccuracy: +/-0.001%of reading.
· Drift:(Zero)lessthan20ppmCO2/ Hour
· ItisdesirabletohaveNon-Dispersive IR (NDIR) Sensor type.
· ThesystemshouldhavehighspeedZirconiadifferentialsensorworksbyheating Zirconium Dioxide to very high temperatures
· Ambient air and sample air should introduce on either side of the Zirconium Dioxide where it then conducts electricity as oxygen ions passes through, creating a Nernst voltageandthisvoltage shouldbeproportionalto thedifferencebetween freshair and sample air.
· Software should provide system control, data collection, and real time calculation of VO2, VCO2, RER and heat/EE with comparison of multiple data side by side, basic stat analysis and prepare graphs for export as jpg.
· Maximumstimulusvoltageshouldnot bemorethan163 V.
· Treadmill speed should be from 6 to 99.9 m/m, continuously variable with inclination of -10 degree to +25 degree in 5-degree steps.
· Warrantyfor atleast5yearand CAMandCMCforfive years
· Softwareupgradefree-of-cost forat least5 years
· All accessories, probes, transducers, leads, cables should be compatible to the system genuine and provided with the set-up
· Equipment should be provided with Branded Compatible Desktop Computer i7 12th Generation, preferably 16 GB RAM, 512 GB SDD and 1 TB HDD, genuine in-built Windows11,in-builtgenuineMS office,Wi-Fi BluetoothwithLED27inchMonitor, coloured Laser printer.
· Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabiliser
· Extra set of leads, transducers, probes, and other relevant accessories should be provided for uninterrupted function for at least 6 years.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (7)
SI. NO. Specification of Master two step
Thecompleteset-upofthefollowingpartsasmentionedundersub-sections (A) and (B) should be provided:
1. Set up for testing active avoidance (also called automatic reflex conditioner or shuttlebox)for rats and mice, i.e.learning to predict the occurrence of an aversive event, based on the presentation of a specific stimulus.
2. Enables performance of a wide range of avoidance experiments using a flexible schedule.
3. Precise detection of avoiding aversive event.Manage up to 4 cages with one controller
b. General features:
1. Shock:constantcurrent
2. ShockIntensity:from 0to 3mA,in 0.1mAsteps
3. ShockDuration:in0.1s
4. VisibleLight:0-100,instepsof5%
5. Soundfrequency:100-18.000Hz,instepsof100Hz
6. OperatingTemperature:10°to40°C
7. PollutionDegree:≤2
8. NumberofCages:Up to 4(with expansion boxes)
c. Physical descriptors:
1. Dimensions:appropriateforratsandmiceseparately–tobefinalizedafter demonstration before bidding and procurement
2. Forratscage:57x27x30(h)cm,I.D.48x20x22(h)
3. Formicecage:47x18x25(h)cm,I.D.38x9x17(h)cm
4. Weight:3.5Kgformousecageandto5.4Kgforratcage
5. ShippingWeight:RatSet-Up13Kg,MouseSet-Up 12Kg
6. Highcontrast,non-reflectivematerialsthatareoptimalforvideotracking.
7. Anti-slip,naturallywarm,mazesurfacetextureisselectedforbestrodentcomfort.
8. SystemincludesaController,andaCageforeitherrator mouse.
d. Touchscreencontrollerwithsoftware:
1. LCD:12”withresistivetouchscren
2. CPUModulePort:2USBPort2.0;1Ethernetport10/100Mb;1DVIportfor external monitor
3. PeripheralPort:4outputsforSound,Shockandlight;1Powersupply12V-2A
4. ExpansionBusConnection: 2RJ11 connectors.
5. Electronicunitdisplaycontrolsupto4cages,incorporatesaconstant-currenthigh precision 8-pole shocker and manages data acquisition.
6. Dataarestoredinsidetheunitandcanbedownloadedforfurtherprocessingor analysis in Excel, Access, etc.
7. samecontrollercanmanagedifferentconditioning tests
e. Performance:
1. Set-upcanperformawiderangeofavoidanceexperiments,eachaccordingtoa flexible schedule (using Timeline feature)
2. Precise detection of animal crossing (moving to a different compartment).Atilting floorprovidesasimple, reliable detection mechanism for scoring animal movement across the two compartments.Apartition with an intercommunicating opening at floor level divides the cage.
3. Measuresrecordedinclude:
· Numberofavoidances(themousecrossingtotheothercompartmentduring the warning signal)
· Numberofnon-responses(themousefailingtocrosstotheothercompartment during the trial)
· Responselatency(latency toavoidorescape)
· Numberofintertrialresponses(i.e.crossingthebarrierwithintheintertrial interval)
f. Maintenance and Accessories:
1. Warranty: Active Avoidance is covered by a12-month warranty + 12 after product registration
2. CMC for atl east 5years with all technical support ands ervices and parts free-of- cost
3. Allnecessarycompatibleaccessoriestocompletetheset-upandtofulfilthepurpose of relevant experiments should be provided
4. Controller with Touch Screen and 8-pole Scrambling Shocker; software; P.A. Rat andMouseCages,USBCable,USBpendrive,othernecessarycables,detaileduser manual should be provided
1. Set-up to test passiveavoidancefor miceand ratsto assessmemory function based on the association formed between a specific environmental context, which the animallearnstoavoidandanaversivestimulus–representedbyamildfootshock.
b. General features:
1. LatencyTime:5-digitRead-Out,0.1ssteps
2. DoorDelay: 1-300s, instepsof 1s
3. Delayafter crossing door:0.2 to 3.0s
4. Shock/PulseDuration:0.1-9.9s,instepsof0.1s
5. ShockIntensity:0.1-3mA,instepsof0.1mA
6. Cut-offTime:0-600s,instepsof1s
7. Shock/PulsePause:0-9.9s
8. Shock/PulseTrain:0-9stimuli
9. VisibleLight: Variable from 0to1800Lux(0-100%)
10. OperatingTemperature:10°to40°C
11. SoundLevel:Negligible
12. PollutionDegree:≤2
13. NumberofCages:Up to 4(with expansion boxes)
14. Silent, automated sliding door divides the dark and light compartments.Systems for mice or rats. Manage up to 4 cages with one controller.
c. Physical descriptors:
1. Atwo-compartmentcage dividedby anautomated, silent sliding door.
2. The first compartment is dimly lit (preferabletoarodent), and the secondis brightly lit.
i. ControllerwithTouchScreenand8-poleScramblingShocker: 25(d)x33(w)x5.5(h) cm
ii. P.A.RatCage:57x27x30(h)cm,I.D.48x20x22(h)cm
iii. P.A.MouseCage:47x18x25(h)cm,I.D.38x9x17(h)cm
i.ControllerwithTouchScreenand8-poleScramblingShocker: 2.7Kg
ii.P.A.RatCage:5.3Kg(40552)
iii.P.A.MouseCage:3.4Kg
5. Highcontrast, non-reflectivematerialsthatareoptimalforvideotracking.
6. Anti-slip, naturally warm, maze surface texture is selected for best rodent comfort.
7. System includes a Controller, and a Cage for either rat or mouse.
d. Touch screen controller with software:
1. LCD:12”with resistive touch screen
2. CPU Module Port: 2 USB Port 2.0; 1 Ethernet port 10/ 100Mb;1 DVI port for external monitor
3. PeripheralPort:4outputsforSound,Shockandlight;1Powersupply12V-2A
4. ExpansionBusConnection:2RJ11 connectors
5. Electronic unit display controls up to 4 cages, incorporates a constant-current high precision 8-pole shocker and manages data acquisition.
6. Data are store dinsidetheunitandcanbedownloadedforfurtherprocessingor analysis in Excel, Access, etc.
7. Samecontrollercanmanagedifferent conditioning tests
8. Tilt-floordetectionmechanism
9. RemoteControlfeature present
1. Tilting floor ensures a simple and reliable detection mechanism to score the animal’s movement across the two compartments.
2. Set ups available for mice and rats
3. Easy,convenient testing using the 12 inch touch screen Controller:
• SetupandmanagebothPassiveandActiveAvoidanceTestsincludingthe8-pole shocker.
• Connectupto4cagestothesameController(usingExpansionBoxforeach additional cage).
• Data is recorded, displayed and stored in the control unit. Transfer test data to yourPCusingtheUSBkey(supplied)forfurtherprocessingusingExcel,Access, etc.
f. MaintenanceandAccessories:
1. Warranty:ActiveAvoidanceiscoveredbya12-monthwarranty+12afterproduct registration
2. CMCforatleast5yearswithalltechnicalsupportandservicesandpartsfree-of- cost
3. Allnecessarycompatibleaccessoriestocompletetheset-upandtofulfilthe purpose of relevant experiments should be provided
4. Controller with Touch Screen and 8-pole Scrambling Shocker; software; P.A. Rat andMouseCages,USBCable,USBpendrive,othernecessarycables,detaileduser manual should be provided
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (8)
SI. NO. Specification of Autonomic Function Test lab
· Non-InvasivebeattobeatHemodynamicRecorderforCardiovascularLab
· The complete system should be portable and easy to carry less than 5 kgs including the carry case
· Shouldbeabletorecordcontinuousbeat-to-beatbloodpressurenon-invasivelyfromthe human subject for long term recording.
· Shouldhavearecordingrangeofatleast60to250mmHgforsystolicBpand40to200 mm Hg for diastolic BP.
· Should be working on the principle of volume clamp (penaz technique) using reusable finger cuffs.
· Shouldhaveprovisiontoswitchbetween2finger cuffsforpressurerecordingtoreduce subject discomfort of long- term recordings.
· Oneofeachfingercuffs small,mediumandlarge sizes.
· Reusable finger cuffs with unlimited usage without damage and self-life of at-least 3 years.
· Extra at least one pair of finger cuffs with transducer and necessary cables should be provided
· Should have the provision to manually switch off the calibration process to record continuousuninterpretedbloodpressuresignalatleastforadurationof5minutesorfor a user defined customizable duration.
· ShouldhavefacilityforHeightcorrectionunittoaccountfortheleveldifferencebetween recording site and heart.
· Accuracy l% for cuff Pressure (within 6 mmHg) and Heart RateAccuracy [HR (bpm)/ 60] %
· Shouldhavefacility foronlineandofflinerecording &Analysis.
· Onlinestreamingofdata toMatlaband Excel.
· The analysed data should be exported to text, IGoR and other file formats online andoffline.
· The Blood pressure data should be integrated & analysed with HRV data (time domain and Frequency domain) online and offline.
· The system should provide cardiac output (CO), Stroke volume (SV), Total peripheral Resistance (TPR), Baroreflex sensitivity.
· Necessary software for recording and analysis of blood pressure signal. The softwareshould provide hemodynamic parameters from pressure data, wave forms etc.
· Softwareupdateandupgradesshouldbeprovidedforatleastnext5 years.
· Onsitetrainingfromthecompanyexpertsshouldbeprovided.
· Should be compatible and seamlessly interface to software for recording and analysis without any additional hardware.
· Should be supplied with compatible portable data acquisition, Laptop PC with intel 12 generationi7processor,in-builtgenuineWindows11,genuineMSOffice,512GBSDD and 16 GB RAM and Laser COLOUR printer
· MusthavenecessarycertificationlikeISO, IEC, CE marked, etc.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (9)
SI. NO. Specification of PLATELET AGGREGO METER
Technical Specifications:
· Platelet Aggregometer working on the principle of Platelet Rich plasma (Optical turbidimetric)/ Whole blood (Impedance)
· Shouldhaveminimumtwochannels withopticalaggregation –AggregationinPRP, with sample volume: 300 microliter or less. Impedance aggregation – Aggregation in whole blood preferably with a sample volume of 500 microliter.
· Should gave adjustable stirrer speed between 400 to 1200 RPM in 100-RPM steps with “stirrer stopped” position, and error detection to prevent operation, if not within (plus-minus) ±10 RPM (present for standard tests – selectable for user defined tests)
Test volume - 250 uL o 500 uL
Reagent volume - 25 uL o 50 uL
Sensitivity - 50,000 platelet/mm3
· Light source LED (Light Emitting Diodes)
Wavelength - UV 400 – 430 nm
· Should have LCD display, one per channel, for display of: (a) Heater block – temperature in °C (b) Stirring speed in RPM (c) Operating mode ( Optical or Impedance) (d) Warning message
· Computerized data analysis with appropriate system software should be included.
· Software updation and upgradation at free-of-cost for at least 5 years
· System should include an internal computer interface and comprehensive software for measuring upto two samples for simultaneous aggregation
· Software on-board should provide for real time display of two channels of aggregation, Computation of amplitude, slope, log time and area under the curve, Storage of reagent data for tracking test value, demography details, for later recall
· ShouldbeFDAandCE approved
· System should be quoted complete with appropriate voltage stabilizer and UPS with one hour battery backup.
· The recommended maintenance kit, accessories, for trouble free operation and maintenance of the system for a minimum period of five years should be quoted.
· The consumables including reagents should be available for supply in local currency and preferably within 72 hours after ordering.
· The after sales service should be available preferably within 72 hours and with trained service personnel. The bidder has to produce a certificate assuring that they have an application specialist and who will be attending any test related problem within reasonable time to ensure zero down time.
· Warranty for 5 years & CMC for next 5 years, which should include cost of labour spares, entire equipment.
· Accessories, reagents and consumables for at least 100 tests, like, ADP, arachidonic acid, epinephrine, collagen, ristocetin, etc. and other consumables should be provided
· Desktop Computer
· Intel i7 processor, at least 16 GB RAM, 512 BG SSD and 1 TB HDD, DVD RW,
· Genuine inbuilt Windows 11 OS, LED Monitor 27”
· Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabilizer
· Laser Colour Printer along with accessories
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (10)
SI. NO. Specification of 16-channelpolygraph
· The system should have 16 channel data acquisition system and analysis software compatible with Windows and Macintosh OS.
· High sampling rate of 100 KHz on each channel with high ADC resolution of 16 bits or more
· The system should be based on proven technology and validated calibration methods to provide a variety of calibration options depending on the research protocol.
· The system should have volume segments and a composite volume, wide range of gain settings, integrated internal ECG circuit, temperature and dual pressure facility that allow comprehensive cardiac function assessment in a wide range of animal models including rats and mice.
· The high-fidelity micro tip pressure and volume catheters for measurements from a single catheter.
· Should be supplied with Rat PV Catheter (2F, 4E, 9mm, 15cm, PI) supplied along with other necessary accessories like connector, cables, calibration cuvettes, amplifiers, software etc for performing the animal cardiovascular and metabolic experiments.
· Various other catheter sizes should be available (ranging 1 to 6 French) for future applications.
· Single system should have Small and large animal recording capabilities.
· The software should have online and offline analysis
· Loop View that allows the display and analysis of individual PV loops, or selected loops of interest.
· The Software should automatically monitor different hemodynamic parameters like
MinimumdV/dt : PreloadRecruitableSW
End-SystolicVolume : MinimumPressure
StrokeVolume : VolumeatdP/dtMax
PressureatdP/dtMin : VolumeatdP/dtMin
PressureatdV/dtMax : End-SystolicPressure
End-DiastolicVolume : End-SystolicP-Vrelation
Ejection Fraction : End-DiastolicP-Vrelationship
MaximumPressure :End-Diastolic Pressure
Time-VaryingMaximum : End-SystolicElastance
Elastance : Time-VaryingMaximum
· Should have at-least 4 plots to display linear regression information.
· Calibration options to check parallel conductance or parallel volume effects
· Direct export of data to Microsoft Excel and other file formats.
· It also has an option for file sharing with distinct user free of cost.
· Facility to perform complete, HRV analysis – Time & Frequency domains, Tachogram, Histogram plot, Poincare plot, Power Spectrum plot etc.ECG analysis – Averaging, PQRST amplitudes and intervals, QT vs RR, QT vs Time, RR vs Time, Waterfall plot and ST elevation
· Software should have channel calculations and frequency analysis tools like PSD, FFT and spectrograph
· It should be supplied with ventilators and a rodent ventilating unit compatible for mice, rat to guinea pig. And should have a direct setting of Tidal Volume, Rate, I/E Ratio, and has automatic sign function. Complete remote control via USB interface allows advanced functions such as constant-volume breath-holds, external triggering, etc. Operates in volume or pressure mode. Safe with oxygen or anesthesia. Multiple animal expansion via rear port. All relevant accessories compatible with the ventilator and ventilating unit should be provided.
· In addition, for autonomic function and cardiovascular experiments for humans, ECG transducer, leads, cables along with all accessories; hand dynamometer with accessories, PPG and sensors for respiratory signals compatible with the data acquisition system should be provided
· Complete set-up of Rodent Langendorff Apparatus with all accessories, Direct Perfusion Core, accurate pressure measurement, heart chamber, seamless switching between two 1-liter reservoirs, lever, bottles, tubing should be provided that are compatible with the software and data acquisition system
· Software should have free update & upgrades for 5 years.
· The system should be certified by ISO and IEC/FDA/European EMC/EC Declaration/BIS, etc.
· Environmental conditions
· Altitude up to 2000m
· Ambient Temperature 10 – 40 °C
· Storage Temperature 20 – 70 °C
· Desktop Computer
· Intel i7 processor, at least 16 GB RAM, 512 BG SSD and 1 TB HDD, DVD RW,
· Genuine inbuilt Windows 11 OS, LED Monitor 27”
· Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabilizer
· Laser Colour Printer
· along with accessories
· CMC, AMC for at least 5 years with all technical support should be provided
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (11)
SI. NO. Specification of Portable hand held doppler
(Apparatus for coordination and cognition)
Technical specifications:
· The rota rod apparatus for small animals should have the facility for at least four running drums.
· System should have the capacity to show angular speed, running time of each animal and the time at which animal falls.
· Animal should be detected through infrared beam sensor attached perpendicular to the rotating rod when the animal is out of rod assembly.
· It should be able to detect the fall of animal from the rod.
· It should also be able to detect the animal if it is not rotating but holding on to the rod.
· System should have the facility to communicate with PC.
· Acceleration speed should be from 0.1 RPM/sec to 20 RPM/sec & increments should be there.
· System should provide angular speed from 0-99.9 RPM.
· System should have the facility for separate spindle for rat & mice.
· Groves should be there in the rotating rod which will provide better grip to the animal
· It should come with software to score the cumulative running from the rats.
· The software should have a facility to record the passive rotation time.
· It should also record running duration, speed at the time of fall and distance travelled.
· The software should have the facility for self check and diagnostic for GLP validation.
· One software should be able to attach multiple Rota Rod for up gradation.
System should also be able to run stand alone without the software.
The equipment should be provided with one Electro-convulsive device (electroconvulsiometer) with the following specifications:
· Electroconvulsive Device apparatus should be useful for neurochemical and neuropharmacological research.
· A constant current output should be used, which ensures reproducible results and accurate determination of the electroconvulsive threshold while also pinpointing any variations in the threshold, brought about by drugs having a specific action on the cortex and subcortical regions.
· The instrument should automatically adjust the current to the value pre-set by the operator, irrespective of the animal’s skin resistance and skin/electrode interface conditions.
· The standard auricular (ear lobe) electrodes supplied allow a single operator to deliver shock to a number of animals in a short time with features to connect to oscilloscope.
· The impedance to the animal should be premeasured and displayed, and a warning signal should flash if the impedance is too great to deliver the desired current level.
· Shock Duration should from 0.1 to 9.9 in 0.1 s steps ± 1%
· Operating Temperature should be from 15° to 30° C
· Current Range should be from 1 to 99 mA in 1 mA steps ± 2%
· Pulse Width (ms) should be from 0.1 to 0.9 in 0.1 ms steps ± 1%
· Power requirements: 115 or 230 V, 50/60 Hz, 75 W max.
· Manuals (digital): Instruction manual-For step by step guide of working
· Frequency (pulses/s) 1 to 299 in 1 pulse/s steps ± 1%
· the use of a CRT is indispensable to monitor shape, width and intensity of the pulses.
· Warranty, CMC for 5 years with all technical support and provision of cables, accessories, electrodes, etc at free-of-cost
· Extra two pairs of electrodes for mice and rats with compatible cables/wires should be provided
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (12)
SI. NO. Specification of Atomic Absorption Spectrophotometer
Spectrophotometer system
· Fully automated computer controlled Inductively Coupled Argon Plasma Emission Spectrometer (ICP-OES) capable to analyze all possible elements of periodic table in aqueous and non-aqueous solutions of varied samples.
· True simultaneous and background correction including simultaneous measurements of all analyte wavelengths, internal standard, and background.
· Systems hould be able to determine, major, minor and trace elements in a dual view and in a single run measurement.
· The instrument must be a Polychromator based true simultaneous reading ICP using solid-state detector technology having Axial, Radial and Dual view.
· The instrument must be a bench-top design with chemical resistant body.
· The instrument must be able to run aqueous matrices, and HF samples and to be offered withfollowingSampleintroductionKitsconsistingofNebulizer-1,SprayChamber-1,Torches-2,Injectors-2&necessarytubings:
1) AqueousSampleanalysisKit:1
2) HFsample analysisKit:1
· Plasma ignition and shut down must be computer controlled and totally automated. The system must include minimum three channels, variable speed, computer controlled peristaltic pump which allows for on-line addition of internal standards.
· Should have shorter startup/warm up time and analysis time, should consume the Argon as little as possible
· Wavelength Range:167 to 840 nm or better
(mailto:0.007@200塹ᴻ䡿ⲯ嶂藄挧ꮥ)
· Optics: Simultaneous echelle type grating
· Measurement type:
· True and simultaneous measurement of all possible elements of periodic table present in the sample
· RF Generator:
· The RF generator must run at a frequency of 27 MHz or more with the facility to cool the RF source, or better.
· The RF Generator must have an optimal power output range of 750 - 1300 watts or better in Axial, Radial & Dual View with capability to use maximum available power and be computer controllable.
· Low Flow Demountable Design, the Torch should be mounted vertically or horizontally so that it can handle high matrix or challenging matrices easily. The instrument should be capable of performing analysis both in axial and radial view so that high concentration and low concentration elements can be analyzed in the same method and in the same sample.
· Plasma ignition and shut down must be computer controlled and totally automated.
· The instrument must include a mechanism to eliminate the cool end of the plasma for minimizing self – absorption and physical interference.
· Gas flow controls:
· The instrument must be provided with mass flow controller (MFC) for all gas flows.
· The instrument must monitor all gas pressures through MFC. The interlocks must be continuously monitored and if any interlock is interrupted, the plasma should shutdown automatically. All the MFC should be factory fitted.
· The plasma flow gas consumption to operate ICP-OES instrument should be 16 L/min or better for aqueous sample.
ü 1. Latest detector CID/CMOS/SCD with anti-blooming features and 100% active area.
ü 2. Detector optimized for performance across the entire emission spectrum, anti-blooming
ü protection to enable the simultaneous measurement of trace level analytes in the presence
ü of major matrix constituents.
· 3.The detector must have Auto–Integration that allows intense and trace signal to be
· Measured simultaneously.
· Wavelength library: 40,000 or more
· System Software:
· The instrument system software shall be based on the windows operating system.
· The software should provide full control of all instrument functions including plasma ignition, gas flows, viewing position, and monitoring of safety interlocks.
· Software should feature automatic identification of possible spectral interferences when selecting wavelengths for analysis and should have search mode for identification of unknown wavelengths.
· Software should have the capability to perform back ground correction such as Inter Element Correction (IEC) or similar way of correcting spectral interferences.
· All standard conditions of various elements shall be built-in and one can select these conditions by entering elements involved.
· There should be the capability to capture the complete spectra of the sample irrespective of the number of elements selected in the method so that the analyst can review other elements which has not be selected previously in the method.
· Measurements shall be made in radial, axial & dual views for all the elements and should be computer controlled with no manual intervention in between.
· Microwave Digestion System for the sample preparation of ICP-OES:
· Microwave output power: 850 -1000 Watt or better peak output power, controllable in a microprocessor. Preference shall be given to system which requires low power for its operation.
· Pressure max: 40 bar or higher.
· Temperature capacity max: Highest sustained temperature of ambient to 250°C or more.
· Material of cavity: Stainless steel with multilayer fluoropolymer / PTFE coating. Acid / solvent fumes resistance, corrosion resistance.
· Volume: Minimum 50 ml or more
· Exhaust & cooling system: In built automatic rapid cooling system.
· Rotor’s capacity: The system should be capable of holding minimum 10 or more high-pressure vessels at a time. The rotor should be made of light weight and must be provided with a lid for protection of cavity.
· System Control: Microprocessor based control system with screen display and storing digestion programs. Should be provided with library of tested methods. IR Sensor / pressure & temperature sensor for all individual vessels.
· Following accessories to be quoted with offered instrument:
· Branded Computer & amp; printer to be supplied along with the instrument from the manufacturer with preloaded licensed version software.
· Water re-circulator for the ICP system should be provided by the manufacturer, if needed for the operation of the instrument.
· sets of Peristaltic Tubing for aqueous samples.
· sets of Peristaltic Tubing for HF samples.
· Fume Hood Exhaust system,
· Suitable 10KVA UPS with at least 30 min backup
· Argon gas cylinder (5 nos.)
· Gas manifold, Argon Gas regulator etc. to be also supplied by the vendor along with all tubing
· Periodic mix standard / Multi-Element standards containing all elements of the periodic table, SRM and CRM of soil & sediment samples should be provided for at least 1000 runs.
· Fume Hood Chamber for chemicals.
· To operate the instrument, maintenance and troubleshooting problems at the place of installation should be imparted to the users of the institute.
· Five years from the date of installation.
· Full system should be covered under warranty period from the date of installation.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (13)
SI. NO. Specification of Bio chemical auto analyzer (Flow Cytometer)
· The instrument should have minimum 3 solidstate lasers i.e. Blue, Red & Violet with at least 50 mW laser power.
· The systemshouldbe able todetectatleast15parametersincluding13fluorescent channels.
· The scatter parameters should be FSC and SSC with ability to detect and resolve 300 nm particles.
· Thesystemshould haveminimum 25,000eventspersecond speedfor acquisition.
· The system should provide superior sensitivity: FITC<30 MESF, PE<10 MESF to measure of events with low staining index for rare detection and application with dim fluorescence staining which is achievable by high efficiency, low-noise.
· SystemshouldabletoProcesssamplesatsampleflowratesbetween10μLand200μL perminuteprovidinghighsensitivityandadjustableflowrates,samplesizesaslowas 25 µL for low volume precious samples.
· Thesystem should haveat least 7decadedynamicrange.
· Thesystem shouldhave APDdetectors forbest levelsof sensitivity&resolution.
· Should have 32 tubes carousal autoloader with capability to individually vortex each tube before acquisition.
· The system should have automated easy to use software to determine the correct compensation matrix with virtual multicolor panel and/or with new gain settings.
· Fully featured analysis software featuring time saving functions such as “linear gain” to automatically modify compensation following gain setting changes and “auto threshold” function whereby the software automatically sets the threshold based on population scaling in order to easily find target population.
· Accepts any company 5mL (12 x 75mm) polystyrene and polypropylene and micro centrifuge 1.5mL and 2mL.
· Automated Maintenance: System should be capable of doing automated maintenance bydoingindividualtubevortex,dailyclean,deepclean.Syringehavinginnerandouter wallautomaticcleaningfunction,reducecross-contamination.Automaticmaintenance procedure: automatic standby / initialization, automatic boot process, row bubble, recoil, automatic shutdown procedures.
· Systemshouldbecompactenoughtobeputinsidebiosafetycabinets/hoods.OneNSF certified biosafety cabinet should be provided.
· Desktop Computer
o Inteli7processor,atleast 16GBRAM,512BGSSDand1TBHDD,DVDRW,
o GenuineinbuiltWindows11OS,LEDMonitor27”
o Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabilizer
o LaserColourPrinter
o alongwith accessories
· CMC,AMCforatleast5 yearswith alltechnicalsupport shouldbe provided
· ElectronicBit datashould beminimum24 bit andhigherwith CVless than 3%.
· Thesystem shouldbe US-FDA/ CDSCO Approved.
· The system should be supplied with 2 set of QC beads, at least 5 tubes of microbeads, cleaning solutions, etc. enough for running machine for atleast 6 months and 30 liters of sheath fluid with at least 500 Flow acquisition tubes (5 ml) and other consumables for at least 500 reactions
· Auto-pipette system: 0.1 - 2.5ul; 2-20ul; 10-100 ul; 20-200 ul and 100-1000 ul.; One multi-channel(08 channel) (100-1000 ul).
· Boxfor theinstrument shouldbe provided
Should be supplied with one analytical weighing balance with the following specifications:
· Capacity:220g
· Readability: 0.0001g(0.1mg )
· Repeatability:0.0001g
· Linearity(±):±0.0003g
· Min.(Capacity):0.01g(10mg)
· Display:TouchScreen
· PanSize:90mmØ
· ResponseTime:4-6Sec
· Calibration:InternalCalibration
· TareRange:Full
OperatingTemperature: :15°C to 30°C
· Density:FunctionAvailable
· Unit:mg,g,ct, ozt,oz, GN,dwt, lb
· WeighingChamberHeight:210mm
· UserPassword:Yes
· Interface:RS232C
· DataOutputMode:Command,ContinuousandStableOutput
· PowerSupply:AC220V/50-60 Hz
· Dimension(LxWxH):220 x360 x 345mm
· Weight: 9.5kg
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (14)
SI. NO. Specification of Fully automated haematologic cell counter
· BenchtopCentrifugalVacuumConcentratorSystemshouldhaveaCentrifugalVacuum Concentrator with integrated vacuum pump for DNA, RNA, Nucleotides, proteins & other liquid or wet samples
· Built-indiaphragmpumpof350W
· PumpshouldhavehighresistantfororganicsolventslikeAcetonitrile,DMSO,Chloroform etc.
· Shouldhaveabilitytoconcentratesamplesuptoa maximumcapacityof 300ml
· Shouldhaveavacuumport for externaldevicethat requirevacuum (e.g. GelDryer)
· Shouldhavemotorlessinductiondriveandchemicalresistantstainless-steelchamber
· SystemshouldhavethreeoperationalmodesforAqueous,AlcoholandHighlyVolatile solvents
· Systemshouldpossessfourtemperatureselections(roomtemperature,30°C,45°Cand 60°C) to allow safe and efficient concentration of samples
· SystemshouldsupportCentrifugationandDesiccatorfunction
· Runtime:1minto9:59hrsinincrementsof1minuteorinfinite
· ShouldhaveBrakefunction
· Noise:<50dB(A)
· Shouldhaveafixed rotationalspeedof1,400 rpm
· Systemshouldhaveimbalance detection
· System should support multiple lab ware formats (0.2 ml,0.5ml, 1.5ml, 2ml,15ml conical tubes, 50 ml conical tubes, 96 well plates, MTP and Deep well plates) with different rotors
· Smallfootprintisrequiredwith Dimension(WxDxH)incm:32x53x30is preferred
· Rotorsandadaptersmustbeauto cleavable
· Systemshould havean emissioncondenser topurify outlet air
· GoodQualitycommerciallyavailablecoldtrapunitmustbequoted
· Basicrotor:48x1.5/2ml tubes
a. Coldtrapunitshouldbeincludedalongwithvacuum concentrator
b. StandardsandSafety
· ComprehensiveWarrantyof5yearswithCMCof5yearsafter warranty
· Comprehensivetrainingforlabstaffandsupportservicestillfamiliaritywiththesystem
· ShouldbeprovidedwiththeVacuumOilPumpwiththefollowing specifications:
• Pump should be a portableAC powered source of vacuum to 585mm/23” Hg (at mean sea level) or pressure to 4 bar/ 58 psig for filtration of liquids or gases use with all types of filter holders.
• Should have 3 pronged (grounded) cord and plug.1/8” BSP inlet and outlet hose connectors.
• Internal pump head surfaces are Teflon coated and leaf valves are of High-grade stainless steel.
• Warranty: 5 years , CMC for 5 years with technical support and services free-of- cost
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (15)
SI. NO. Specification of Ice-lined refrigerator (ILR) / minus 20 degree Celsius Deep Freezer)
TheRefrigeratormustmeetthefollowingcriteria:
· Refrigeratormusthave(1)hingedsolid doors
· RefrigeratormusthavePositiveforced-aircirculation
· RefrigeratormusthaveAutomaticdefrostsystem
· RefrigeratormusthaveMicroprocessorbasedElectronicControllerwith7Segment LED display
· RefrigeratormusthaveMercury-freeLEDinteriorlighting
· Refrigeratormusthaveexternallymountedinternallightswitch
· Refrigeratormusthaveacapacityof465Literscapacity
· Refrigeratormusthavea1-minutedooropeningrecoveryoflessthanorequalto8 minutes
· Refrigeratormusthavesetoffourcastersstandardandinstalledinfactory
· Refrigeratormusthavedigitaltemperaturedisplay
· Refrigeratormusthaveatemperatureresolutionto0.1°C
· Refrigeratormusthaveatemperatureuniformityof1.4°Corbetter
· Refrigeratormusthaveadjustablecoldandwarmalarms
· Refrigeratormusthavebothaudibleandvisualalarms
· Refrigeratormusthavedoorajaralarmand icon
· Refrigeratormusthaveservicealarmandicon
· Refrigeratormusthavelowbattery alarm
· Refrigeratormusthave(5)internalwireshelves
· Refrigeratormusthavestandard1”rearaccessportstandard
· Refrigeratormusthavestandardremotealarmterminalsstandard
· RefrigeratormustbeCE certified
· RefrigeratormustincorporateRodentproofpower cord
· RefrigeratormustuseenvironmentallyfriendlySNAP&F-GASCompliantHC refrigerants
· Refrigeratormustoperateatlessthanorequalto55.1dba
· Refrigeratormustsupportastandardsettablerangeof-25Cto-15C
· Refrigeratormustincludesofttouchgripforfulldoorlengthhandle
· Refrigeratormust haveLoadLimitof45kg(99.2lbs)perShelf
· WarrantyandCMCforatleast5yearswithallsupportandservicesfree
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (16)
SI. NO. Specification of UV-VIS Spectrophotometer
· Optical design Double-beam with sample and reference cuvette positions with Czerny-Turner Monochromator
· Spectral Bandwidth- 1nm
· Light Source-Xenon Flash Lamp with three years warranty (7 years typical lifetime)
· Detector: Dual Silicon Photodiodes
· Wavelength range 190–1100 nm
· Wavelength Accuracy: ±0.2 nm (546.11 nm mercury lines)
· Wavelength Repeatability: ≤0.01 nm(546.1 nm mercury line, SD of 10 measurements)
· Scanning Speed: <1 to 6000 nm/min or better
· Photometric Range >3.5 A or better
· Photometric Display Range -0.3 to 4.0 A or better
· Photometric Noise 0A: ≤0.00015 A
· Stray Light KCl, 198 nm: ≤0.40% T
· Baseline Flatness ±0.0006 A or better.
· Data intervals 10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
· Two pair of standard quartz cuvette to be quoted (1 ml & 3.5 ml).
· CE certificate & ISO certificate should be provided.
· Warranty: -The complete system should be covered with five years of comprehensive warranty.
· Should supply with two (02) 0oC Mini Cooler (with Non toxic gel) : i. capacity should be 15 ml having 12 places at least; ii. capacity should be 1.5 ml having 32 places at least.
· Should be provided compatible branded desktop computer (12th Generation Intel Core i7/16GB/1TB/1TB SSD/Windows 11 Home/Intel HD Integrated Graphics, online UPS (min 30 min power back up), CD/DVD writer/reader, USB ports(4), 23” LED screen with laser printer)
· Should be provided one (01) multi-channel & variable volume MicroPipette (100-1000 ul)
· Should be provided two (02) sets of with single channel & variable volume Micro Pipettes (05 Nos.) with pipette stand: 0.1 - 2.5ul; 2-20ul; 10-100 ul;20-200 ul and 100-1000 ul. Micro Pipettes should have 4digit display for more accurate volume setting and easier volume identification. Without removing any parts, full pipette needs to withstand Autoclave sterilization at 121°C for 20 min. Pipette Volume Range with Volume Increments [0.1-2.5 ul – 0.002ul increment; 2-20ul – 0.01ul increment; 20-200ul – 0.2 ul increment; 100-100ul- 1 ul increment]. Pipette Piston with highly resistant to heat, acids and alkalis, mildew, bleaches, aging, sunlight and abrasion. Should have ultralight weight mechanical pipette. Micro Pipettes should have minimum 3 years warranty.
· Should be supplied with one pH Meter of following specifications:
o Meter specification :
pH Range : -2 to 20
Resolution : 0.001
Accuracy : ±0.002
Calibration points : up to 5 .
Temperature range : -5 to 105 °C
Data logging memory: 2000 data with date & time stamp.
Power : AC adapter/Optional 4AA batteries.
IP rating : IP54 rated
Calibration Editing: Yes
o Electrode Range:
pH electrode Range:0-14
pH electrode Temp Range:0-100°C
pH electrode body: Glass.
Warranty: 3 years on Meter 12 months on pH probe.
Supply should include :
Includes main meter; Glass body refillable pH/ATC probe with ceramic junction and filling solution ; pH 4, 7 and 10 buffers; storage solution; cleaning solution; and pH electrode storage bottle; Electrode holder and stand , power Adapter with certificate of calibration by manufacturer.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (17)
SI. NO. Specification of Kits and Solvents
Magnesium Chloride 500g; Molecular Biology grade; purity ≥99%
Sodium Chloride 500g; ACS grade reagent; purity ≥99%
Sodium bicarbonate 500g; ACS grade reagent; purity ≥99%
Sodium dihydrogen phosphate anhydrous 500g; ACS grade reagent; purity ≥98%
Sodium phosphate dibasic 500g; ACS reagent, ≥99.0%
Phenylmethyl sulfonyl fluoride 100g; powder, ≥98.5% (GC)
Nitrocellulose Membrane, 01 roll; 0.25 µm, 9 cm x 10cm
PVDF membrane; 1 roll, 8.5cm x 10m, 0.45 µm pore size; should have low background fluorescence for Western blotting. Should compatible with visible and infrared fluorescent probes.
Tris HCl- 1kg; Assay ≥99% (titration), useful in pH range 7.0-9.0
Trizma base (1 Kg), BioUltra, for molecular biology, Assay ≥99.8%
ECL Plus Western Blotting Substrate 500 ml. Should able to detect of low-picogram amounts of target protein.
Potassium hydroxide 500g; ACS reagent, ≥85%, pellets
Potassium chloride 500g; ACS reagent, Assay: 99.0-100.5%
Glycine- 500g; Assay: ≥99% (HPLC), suitable for western blotting
Acrylamide- 1000g; Assay: ≥99%; suitable for electrophoresis.
Bisacrylamide-1000g; Assay: ≥99.0% (saponification, acidimetric), should be used for electrophoresis and molecular biology.
Sodium Dodecyl Sulfate- 500g; Assay: ≥99.0% (GC), should be used for molecular biology.
Ammonium persulfate – 500g, should be used for molecular biology, suitable for electrophoresis, Assay : ≥98%
TEMED (N, N, N’, N’- tetramethyl ethylenediamine)- 100ml; suitable for electrophoresis, ≥99.0%
Bromophenol Blue -50g; ACS reagent, should be used for molecular bilogy
Glycerol -500ml; molecular biology grade; Assay: ≥99.0%
Coomassie Brilliant Blue G 250; 100g; >5000 mg/kg LD50
2-Mercaptoethanol – 100 ml; for molecular biology, suitable for electrophoresis, suitable for cell culture, 99% (GC/titration)
Butanol – 2 L; Assay: 99.9%
Pyridine - 2L; ACS reagent Assay: ≥ 99.0%
Acetic acid- 2L, ACS reagent; Assay≥99.7%;
Bovine serum albumin 100g; protease free, IgG free, fatty acid free, Ph 7.0, ≥98%; should be used for western blot, electrophoresis, ELISA; should be essentially globulin free, ≤3 EU/mg endotoxin.
Ethylenediaminetetraacetic acid (EDTA)- (100g x 2) ACS reagent; Assay: 99.4-100.6%;
Chloroform 2L; Grade: ACS reagent; Assay: ≥99.8%
Phenol (500ml), molecular biology grade, Assay: ≥99.0% (GC)
Isopropenol/2-Propanol 2L; Grade: ACS reagent; Assay: ≥99.5%
Sodium acetate (500g x 2), Grade: ACS reagent; Assay: ≥99.0%
Culture plate – 500 pieces
Agarose- 1kg; Grade: molecular biology
GelRed -0.5 mlx2 (for nucleic acid staining)
Ethidium bromide 10 ml, Concentration 10 mg/mL;; Grade: Molecular biology
PCR tube – 8 well tubes with cap 500 nos, 96 wells tubes with cap 500 nos; compatible with most of the PCR machine.
PCR tube stand -06 nos; Should be autoclavable.
Pyrogallol 100g, Grade: ACS reagent; Assay: ≥99.0%
Minimum Essential Media (MEM) 500 ml
DMEM Cell Culture Media 500 ml
Roswell Park Memorial Institute (RPMI) 500 ml
FETAL BOVINE SERUM (500mL); hemoglobin, ≤20 mg/dL
Antibiotic Antimycotic Solution (100×) 100 ml,
Non-Essential Amino Acid (100×) 100 ml, Without ʟ-glutamine, liquid, sterile-filtered, suitable for cell culture.
TRYPSIN-EDTA (500ml), suitable to cell culture
L-GLUTAMINE (100mL), suitable for cell culture.
Dimethyl sulfoxide (500 ml); suitable for cell culture and cryopreservation; Assay: ≥99.5% (GC)
Human AB Serum (500mL); suitable for cell culture,
MTT ASSAY KIT (Qty 2); one for In Vitro Toxicology Assay (for 1000 reactions); one for Cell Growth Assay (for 5000 reactions)
DNA METHYLATION – Lightning Kit (for 100 reactions)
DNA ISOLATION KIT; (for 100 reactions);
RNA ISOLATION KIT; (for 100 reactions);
RIPA LYSIS BUFFER; 10X (100mL); should be suitable for immunoprecipitation/ western blot
PROTEASE INHIBITOR COCKTAIL (10 mL); Should be suitable for plant cell and tissue extracts.
METHANOL 2.5L x 2; Assay: ≥99.8%, Grade: ACS reagent.
SKIMMED MILK (500g)
PROTEIN LOADING DYE for SDS-PAGE, 2X (1ml x 2)
PROTEIN PRESTAINED MARKER
DNA Loading Dye (6X) - 5ml x 2; Label: Bromophenol Blue, Orange G, Xylene Cyanol FF (XCFF); Gel Compatibility: Acrylamide Gels, Agarose Gels.
Trizol (200 ml); Yield should be : DNA: ≤7 μg
RNA: ≤73 μg; Grade: molecular biology
Phenol: Chloroform: Isoamyl Alcohol 25:24:1, Saturated with 10mM Tris, pH 8.0, 1mM EDTA; Assay: ≥99.8%, Grade: molecular biology.
Ethanol 5L; Grade: ACS reagent for analytical purposes, for extraction reagent grade; Assay: ≥99.9% (GC)
Cetyltrimethylammonium Bromide (100 ml x 2); Molecular Biology Grade; Assay: ≥98% (TLC)
RNAse (500mg x 2); Biological source: bovine pancreas; specific activity: ~40 U/mg dry powder [dry powder according to Kunitz (+25°C; RNA as substrate)]
DNAse (100mg x 2); Biological source: bovine pancreas; Suitable for technique(s) cell culture | mammalian: suitable.
Chloroform:Isoamyl alcohol 24:1 (1 L) ; suitable for nucleic acid purification,
DNase free Ribonuclase A (50 mg x 2); for molecular biology; specific activity: ≥70 Kunitz units/mg protein (Exonuclease, endonuclease, NICKase and DNase free)
Sodium Acetate (500g x 2); Assay: ≥99.0%, Grade: ACS reagent.
TRIS (HYDROXYMETHYL) AMINOMETHANE HYDROCHLORIDE; Grade: ACS reagent. Solid form, reag. Ph. Eur., GR for analysis buffer substance
Tris(hydroxymethyl)aminomethane (500g x 2), 99.8%, ACS reagent
Hydrochloric acid (500 ml), 37%; Grade: ACS reagent.
H2SO4 (500 ml); Grade: ACS reagent
DAPI (10 mg x 2), [4′,6-Diamidino-2-phenylindole dihydrochloride, 2-(4-Amidinophenyl)-6-indolecarbamidine dihydrochloride]; Grade: molecular biology; Assay: ≥98% (HPLC); should be suitable for suitable for fluorescence; Solubility: H2O: 20 mg/mL & PBS: insoluble.
T-25 CULTURE FLASK (CELL CULTURE TREATED) 500 pieces
T-75 CULTURE FLASK (CELL CULTURE TREATED) 500 pieces
T-25 CULTURE FLASK (SUSPENSION Culture) 500 pieces
T-75 CULTURE FLASK (SUSPENSION Culture) 500 pieces
6-WELL CELL CULTURE PLATE (CELL CULTURE TREATED) 500 pieces
12-WELL CELL CULTURE PLATE (CELL CULTURE TREATED) 500 pieces
24-WELL CELL CULTURE PLATE (CELL CULTURE TREATED) 500 pieces
48-WELL CELL CULTURE PLATE (CELL CULTURE TREATED) 500 pieces
96-WELL CELL CULTURE PLATE (CELL CULTURE TREATED) 500 pieces
6-WELL CELL CULTURE PLATE (SUSPENSION Culture) 500 pieces
12-WELL CELL CULTURE PLATE (SUSPENSION Culture) 500 pieces
24-WELL CELL CULTURE PLATE (SUSPENSION Culture) 500 pieces
48-WELL CELL CULTURE PLATE (SUSPENSION Culture) 500 pieces
96-WELL CELL CULTURE PLATE (SUSPENSION Culture) 500 pieces
50-ML FALCON TUBES 500 pieces
15-ML FALCON TUBES 500 pieces
MEDIA FILTERATION UNIT 100 pieces
MICROCENTRIFUGE TUBES (0.5mL) ; (500 pieces x 5 pkt)
MICROCENTRIFUGE TUBES (1.5mL); (500 pieces x 10 pkt)
MICROCENTRIFUGE TUBES (1.5mL) (500 pieces x 10 pkt)
50 ML FALCON TUBE STAND box10 pieces)
15 ML FALCON TUBE STAND box (10 pieces)
15 ML FALCON TUBE STAND (10 pieces)
1.5 ml microcentrifuge tube storage 10 pieces
Pipette Stand (06 Nos.), Capacity: minimum 05; Material: PMMA
1.5 mL Microcentrifuge tube rack; should hole minimum 20 tube (20 pieces)
Serological pipette: 10 ml- 10 Nos.; 5 ml- 10 Nos.
TRYPAN BLUE SOLUTION (0.4%) (20ml x 5); should be suitable for cell culture
Corning Syringe Filter (100 Nos.) (Pore size: 0.2 μm, Diameter: 28 mm); material: polyethersulfone membrane.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (18)
SI. NO. Specification of Biosafety cabinet
· The Biological Safety Cabinet should be of Class II , Type A2 designed in compliance with International Standards
· The Biological Safety Cabinet quoted instrument model must have International standards test like NSF, TUV NORD, EN 12469 Certification. Certificate copy must be provided along with the technical bid.
· Working area should be around 4 feet.
· It should have feature for Personal Protection, Sample Protection, Cross Contamination Protection and Environmental Protection.
· It must utilize Brushless DC motor technology which uses significantly less energy with less heat emission provision compared to traditional AC motor technology to ensure lower levels of energy consumption.
· The system should be designed with dual motor.
· The motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction.
· Air Flow Direction: Vertical Laminar Flow & Air intake across front opening and 70% recirculation.
· Filter: High performance particle air filter H14 (HEPA EN1822), filtering efficiency 99.995% MPPS or better.
· Energy saving mode when cabinet not in use with maintaining sterility. Continuous airflow helps to maintain a sterile environment, even when the cabinet is not in use.
· The system should have independent sensors to detect pressure changes across the exhaust and down flow plenum/air velocity and should indicate alarm signal when a 20-30% change in inflow/exhaust or down flow occurs.
· Control Panel and Performance monitor displays inflow / down flow velocities, hours of use etc. to verify proper cabinet operation.
· Front glass window should be easily lowered for thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered.
· The UV light must be quoted which should be programmable from 30 min to 24 hrs in minimum 30 minutes increment to shut off automatically. The settings must allow the user to program the timer.
· The cabinet noise level must be less than 63 dB (A) as measured in a sound proof room topromote more comfortable and safer working habits of the user as per NSF/ ANSI 49.
· The controller must be located on a slanted front panel so it is easy to see from a seated working position in front of the cabinet.
· Control panel should be a large digital color Touch screen display with health monitoring system, valuable safety and performance data withconstant read-out of Downflow/inflow velocities and hours of operation in real-time, number ofhours of use on the HEPA filters.
· The front Window sash must be angled 10° sloped front for operator comfort.
· Two pieces of removable and autoclavable stainless steel Arm rest should be provided foroperator’s comfort without disturbing the Air Flow.
· The system must have audio visual alarms to indicate when inflow is restricted and as well aswhether front window is in correct position or not.
· The Work Area should be illuminated with switchable fluorescent lamp of lighting power >120 fc or higher.
· Suitable height floor stand without casters should be provided.
· In built Access ports, 2 nos. (1 on each side) should be available.
· It has Single piece stainless steel work tray for easy Cleaning and decontamination.
· Warranty: Minimum 5 year comprehensive warranty.
· Electrical Supply Available: 230V A.C, single phase, 50 Hz.
· Bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website.
· Prompt & efficient after sales service should be available.
· User List: Minimum 10 numbers of quoted model should have been installed in GovernmentInstitution (List should be enclosed).
· Quoted with compatible at least 2KVA servo voltage stabilizer.
· Should supply with Micro centrifuge (13500 RPM) with one PCR tube rotor and one fixed angle rotor (12 x 1.5 ml).
· Should be provided two (02) sets of with single channel & variable volume Micro Pipettes (05 Nos.) with pipette stand: 0.1 - 2.5 microliter (µl); 2-20µl; 10-100 µl;20-200 µl and 100-1000 µl.Micro Pipettes should have 4 digit display for more accurate volume setting and easier volume identification. Without removing any parts, full pipette needs to withstand Autoclave sterilization at 121°C for 20 min. Pipette Volume Range with Volume Increments [0.1-2.5 µlwith0.002µl increment; 2-20 µlwith0.01 µl increment; 20-200 µlwith0.2 µl increment; 100-100µlwith1 µlincrement]. Pipette Piston with highly resistant to heat, acids and alkalis, mildew, bleaches, aging, sunlight and abrasion. Should have ultralight weight mechanical pipette. Micro Pipettes should have minimum 3 years warranty.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (19)
SI. NO. Specification of Coolong centrifuge
· Max.Speed :29,000 rpmor more
· Max.RCF : 100,500 x gor more
· Max.Rotor Capacity: 6x 1000ml in Fixed-angle,4 x1000 mlin swing-bucket options
· Control:Microprocessorbased,Touch-screeninterface(canbeusedwithgloved hand)
· DriveSystem:brushless,high-frequency,directdrivewith3-yearnon-prorated warranty
· Temp.SetRange:-20°Cto40°C
· Refrigerationsystem:CFC/HCFCfreewith5-yearnon-proratedwarranty
· RunTime:99hrs;Hold
· Temp.ControlAccuracy:±2°Cofsettemperature
· Speedcontrol range: 500 to 29,000 rpm
· SpeedControlAccuracy:±25 rpm
· Programmability:99programsormore
· Acceleration/DecelerationProfile:9/10
· Power:200-240VAC,50Hz,30A,singlephase
The centrifuge must provide automatic and instant rotor identification, completed upon installation of the rotor into the centrifuge, before the run is started
Fast, simple, and secure push-button rotor exchange mechanism to automatically lock the rotor onto the drive adapter, eliminating the need for a tool or to hand tighten.
Must have a rotor landing pad near the touchscreen for better ergonomics
The centrifuge must have a optional vacuum system, with a HEPA filter option, which only operates when needed and can be user selected for high performance or for energy saving.
The centrifuge must be able to run without the use of a partial vacuum to protect sensitive samples in microplates, as well as other tubes and bottles.
Rotors: The centrifuge must be quoted with following rotors a. Fixed angle hi-speed conical 24x15ml rotor that can reach up to 21,500 rpm & RCF 63,049xg. One set of tubes and accessories must be included. b. The centrifuge must be quoted with a non-metallic high capacity 48x1.5ml rotor that can reach RCF to 57,368xg & at least 23,000 rpm. c. Fixed angle hi-speed conical 8 x 50 ml rotor with at least 27,000 rpm and 87,200 x g or more.
The centrifuge must have an energy savings mode (“sleep mode”) to reduce power consumption up to 15% by turning itself off if idle after a period of time.
The centrifuge must have certificates of ISO, cULus and CE safety requirements without being bolted to the floor, to provide flexibility to relocate within the facility.
Warranty of the machine: 5 years CMC.
Must have more than 300 installations in India, with at least 5 performance certificates mandatory.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (20)
SI. NO. Specification of CO2 incubator
· MicroprocessorbasedCO2Incubatorwithwork chambervolumeofapprox.165litersor more.
· TheCO2 IncubatormusthaveDirectHeating system.
· Theincubator should becapableto operateat ambient+3oCto ambient +55 oC.
· Theincubatortemp.control:±0.1°CandUniformity:<±0.3°C,TrackingAlarm:±1°C
· HumidityControl:>90%rH@37degC,andHumidityReservoircapacitynotmorethan 3 liter to allow more space for samples and to maintain optimum humidity at the same time.
· CO2concentration range:1–20%and CO2 Inletpressureapproximately12-16 PSI.
· CO2Control: ±0.1% ,Tracking Alarm: ±1%.
· Sterilizationcycletime:approximately10-12hrs.
· CO2 concentration, Temperature and Humidity to be controlled by IR Sensor. Should be silicon based IR sensor for better intensity.
· Systemmusthaveprovisionforbuiltinautomatic180°CormoreHighTemperature Sterilization.
· Theincubatormusthave atleast3nos.stainlesssteel,perforated, adjustable shelves.
· System should have access port of around 40 mm to allow any cable, plugor tubingto beeasilyinsertedintooroutofthechamber.
· The system should have data collection software to facilitate data capturing. The USB output port should be rear mounted for convenient and safe operation.
· ThesystemshouldhaveInteractiveControlwithTouchScreeninterfacewithbrightLED, large display. There must be provision to store all types of parameters of CO2 incubator for around 30 days.
· System should have Active Airflow with in-chamber stainless steel fan for mechanical convection. The fan should be vibration free and it should gently distribute clean, humidified air throughout the chamber ensuring homogeneous conditions and maintain uniformity of CO2, temperature, and humidity for better cell culture. The fan should be capable of faster recovery for all parameter after every door opening by the help of mechanical convectionand it should protect valuable cell lines from drying out without any contamination.
· Thehumidityreservoirwaterlevelshouldbecontinuouslymonitoredanddisplayedonthe touch screen with advanced refill reminder. The reservoir should be filled without removing shelves or cultures and easily drained through built-in copper drain.
· The system must have provision for incoming air that travels first over a direct heated water reservoir resulting in 50% faster humidity recovery.
· System must have in-chamber HEPA filter that cleans the airstream of microbes and particles protecting cultures from contamination. HEPA air filtration system should complywith ISOClass5clean roomairqualityandrecovertothatqualityofairwithin5 minutes of door closure (in accordance with ISO 14644-1 and ISO 14644-3).Entire chamber air volume must be filtered nearly every 60 seconds.
· The fan must have an auto–stop function which disables fan operation during door openingstominimizeairexchange. Oncethedoor isclosed,thefan shouldacceleratefor quick recovery.
· The CO2 concentration should recover within 5-6 minutes, relative humidity should recover within8-10 minutes and temperature should recover within 5-6 minutes from a door opening of 30 seconds.
· SystemshouldhaveDualtemperatureprobeswithPIDcontrollertoprovideover temperature protection by preventing overshoot during recovery.
· Systemshouldhaveatleasttwodoors,onemaindoorwithrighthinge andoneglass door.
· Suitable for 230V, single phase50Hzoperation. Power consumption between 0.5-0.6kW.
· DoublestageCO2pressureregulatorwithstainlesssteeldiaphragmand15-20kgCO2 cylinder filledwith CO2Gas 99.5%orbetter purityshould beincluded.
· Suitableservovoltagestabilizershouldbeincludedforsafety oftheequipment.
· Prompt&efficientafter salesserviceshouldbeavailable.
· Atleast10userlistfromcentral/stategovtinstitutions)mustbe provided.
· Thequotedmodelspecificationsshouldbeavailableinthemanufacturer’swebsite.
· Warrantyfor5years.
· ShouldincludeaLiquidnitrogen Tankas perbelow specs:
· Compactdesigntominimizespace requirements whilemaximizingstorage capacity
· Suitedforbothmanualand computerizedinventoryrecord-keepingmethods
· Outstandingtemperatureuniformity:samplesarestoredbelow-180°C,evenwhen less than 2 in. (5cm) of liquid nitrogen remains in the vessel
· Audiblealarmthatsoundswhennitrogenlevelfallsbelowsaferange;dryremote alarm contact for remote monitoring
· Advancedvacuuminsulationtominimizeliquidnitrogenevaporationandreduces operating costs
· Securelockingtopreventunauthorized entry
· Capacity: Minimum71L(2.507cu.ft.).TemperaturerangeBelow-180°C, Insulation: Vacuum, Rack capacity: Min.4, sample to hold upto 6000, static holding time: 83 days, CE/CSAcertification, Level monitor included,Vial capacity-Min. 2000.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (21)
SI. NO. Specification of Culture plates and glassware
Items(Plastic ware)
Aspirator Bottle with stop coack , 10 litre
Aspirator Bottlewith stop coack , 20 litre
Narrow Mouth Wash bottle, 125 ml
Narrow Mouth Wash bottle, 250 ml
Wide Mouth Autoclavable wash bottle,500ml
Mesuring Cylinder Class B, PP, 25 ML
Mesuring Cylinder Class B, PP, 50ML
Mesuring Cylinder Class B, PP, 100 ML
Beaker, 50ml ,PP
Beaker, 50ml, PP
Membrane Filter Holder- 47mm, PSF, 25ml
Membrane Filter Holder- 47mm, PSF, 500ml
Handy Pipette aid, PP silicon- 10ml
Handy Pipette aid, PP silicon- 25ml
Pipette bulb, PP natural rubber - 100ml
Pipette Rack Hortizontal-PP, 12 places
Reagents Reservoir, PP Autoclavable-75ml
Graduated Tip Reload- PP Autovlavable- 10 micro litre
Graduated Tip Reload- PP Autovlavable- 200 micro litre
Graduated Tip Reload- PP Autovlavable- 1000 micro litre
Vortex shaker (Digital)
Test Tube Rotator , Disc for 24x1.5ml tubes
Test Tube Rotator , Disc for 18x15ml tubes
Test Tube Rotator , Disc for 12x50ml tubes
-20 degree C, Mini Cooler for 5ml, Micro centrifuge tube, 12 places
-20 degree C, PCR Mini Cooler , The aluminium block has 96 holes to hold tubes, Strips and plates-0.2ml
Cryo Gloves, Thermal protection for hand and arm protection in ultra cold Environment, Mid arm- medium size
Ice bucket with Lid, Durable rigid ice bucket unbreakable, insulating properties for liquid nitrogen, dried ice, water ice salt solution and acetone- 2.5 L, dimension (335x28x118)
Ice bucket with Lid, Durable rigid ice bucket unbreakable, insulating properties for liquid nitrogen, dried ice, water ice salt solution and acetonr- 4.5 L, dimension (335x285x187)
Hand Protector Grip- Silicon
Float Rack, PP- 16 places (1.5ml)
Rack for micro centrifuge tube, PC autovlavable, 10 places(5ml)
Conical Centrifuge Rack, RPP (Full Rack)
Rack for micro tube, PC-1.5ml (24 places)
Rack for micro tube, PC-1.5ml (48 places)
UV safety goggles
Utility Tray, PP (Size- 320x260 x100 mm)
Test tube Basket with cover, PP (size- 180x170x160 mm)
Desicator plain, PP/PC (200mm diameter)
Paraffin , Thermoplastic-self sealing film (size- 4”x250’)
Paraffin dispenser
15mL Conical Sterile Polypropylene Centrifuge Tubes
50mL Conical Sterile Polypropylene Centrifuge Tubes
PCR Tubes & Caps, RNase-free, 0.2 mL (8-strip format)
MICROCENTRIFUGE TUBES (0.5mL) cap (Lid),clear polypropylene
MICROCENTRIFUGE TUBES (1.5mL) cap (Lid),clear polypropylene
MICROCENTRIFUGE TUBES (2.0mL) cap (Lid),clear polypropylene
MICROPIPPETE TIPS, PP,0.2-10 μL
MICROPIPPETE TIPS,PP,200-1000 μL
MICROPIPPETE TIPS,PP,200-1000 μL
Cryo vial, 1.8 ml , 1000 Packing
Cryobox for storage of 1.8 ml vial with 81 place
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (22)
SI. NO. Specification of Autoclave
· Capacity:75ltrs,Vertical
· InnerDimension (Dia.xLength):16*24inch(400*600mm)
· OperationMode:Fullyautomatic(DigitalControllerwithAutomaticPressureRelease Valve)
· Construction:DoubleWalledInnerChamberStainlesssteel304
· Externalchamber:Stainlesssteel304LidStainlesssteel304
· Ring&Stand:Stainlesssteel304HeaterImmersionheater
· Gasket:Hightemperaturesiliconerubbergasket(Jointless)LockingsystemRadial locking mechanism w/ pedal lifting device
· Temperaturerange:121°Cto126°CTemperatureaccuracy±1°C
· Temperaturesensor:PT100
o Digitaltemperaturecontroller
o In-builtdigitaltimer0-60minutes
o ENDofsterilizationbuzzeralert
o Digitaldisplay ofpressure
o Sensorbroken indication
· Pressure:15to20psi
· Steamrelease:Automaticsteamrelease aftersterilization
· Releasevalve:Solenoid valve
· Pressuredisplay:Dialtypepressuregauge
· Pressurecontrol:Automaticpressurecontrolswitch
o Overpressuresafetyvalve
o Automaticvacuumbreaker
o Lowwaterlevelcut-off sensor
· Basket:Wiremeshbasket
· Powersupply:220Volts50Hz
· WaterInletValve
· No,Directly pourinto thechamber
· Standard accessories
Water levelindicator(glass) Water drain valve
· Warranty:5years
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (23)
SI. NO. Specification of Media filtration system
· Ultrasonicprobesonicatorwithrequiredpower:650Wattsormore
· Operatingfrequency22-25KHzwithautofrequency changing
· Timershouldcontroltheprocessingfrom1secto10hours
· Adjustableenergy,intensitywithvariableamplitudecontrols(10-100%)andmonitor digitally and graphically
· Ultrasonicprocessorswithintegratedtemperaturecontrollerunits(setfrom1–100 degree Centigrade)
· Microprocessorcontrolled,completelyprogrammablewithmemorystoragefeatures(≥ 10 protocols)
· Samplesize:shouldbesuppliedwithsuitableTitaniumprobesof≤3mmand≥6mm that can process minimum sample volume of 250 microliter and maximum 250 mL sample
· CompatibleSS temperatureprobeshould besupplied
· Shouldbesupplied withimported soundproof enclosure
· Shouldbe suppliedwith suitableStand and Clampto makethe system functional
· ShouldhaveConverterToolKitandFootSwitchConnectionandPowerCord
· CompanyshouldbeISO/CEandBSIcertifiedandshouldmeetinternationally recognized safety norms
· SystemshouldbeRoHS compliant
· Additionalaccessoriesrequiredformaintainingsampletemperature4to10degree Centigrade
· Automatedchillerbatch with recirculators
· ShouldbesuppliedwiththeCupHornthatcanprocesssamplesinabsolute isolation (in microcentrifuge tubes)
· Allpartsoftheinstrumentshouldbefromsamecompany–nolocal-madeinferior quality parts should be there
· Power: 230V/50Hz
· WarrantyandCMCforatleast5yearsincludingalllabourcost,spareparts, consumables and preventative maintenance
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (24)
SI. NO. Specification of Refrigerator
· GrossVolume(Litres):morethan630L
· Dimensionswxdxh (cm):91.2x61.0x 174
· Icemaker:DualIceMaker
· NumberofDoor Pocket:5
· Compressor:DigitalInverterCompressor
· TemperatureRange:2–8°C
· No.ofLids/Doors:02
· No.ofshelves: minimum 4
· InteriorLight:LED
· Wheels/Castors:Yes
· No. of Compressors:1
· Refrigerant:R600a
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (25)
SI. NO. Specification of Real time PCR (RT-PCR)
Real Time (RT) PCR should have following features:
· The system should be automated and integrated with 96 well peltier based for both real-time PCR and post-PCR (end-point) analysis with 6 independently controlled zones.
· It should have interactive touch screen LCD for standalone operation with 8 - 10GB onboard memory for storage of at least 1600 - 2000 runs.
· System should support minimum recommended reaction volume of 10–30 μL/10–100 μL for 0.1/0.2 mL block.
· The Quoted System should support the temperature range from 4oC to 99oC with block ramp more than 6 oC/sec, and run time less than 40 minutes.
· System should have six de-coupled excitation and emission filter sets to enable collection of up to 21 unique combinations of wavelengths during a single run for multiplexing five colors or above.
· The System should utilize a bright white LED source, excitation by LED light source with a > 5 years lifespan and detection by CMOS/CCD with whole plate imaging anddetection.
· The system should be factory calibrated for the following FAM/SYBR Green, VIC/JOE/HEX/TET, ABY/NED/TAMRA/Cy3, JUN, ROX/Texas Red, Mustang Purple,Cy5/LIZ, Cy5.5 dyes
· The system should be able to do applications such as Gene Expression, Genotyping, Copy Number Variation, Pathogen Detection, Strain Typing, and Viral Load, MutationScanning, Methylation and other Epigenetic Applications, miRNA profiling, Protein analysis with proximity ligation assays and Protein Thermal Shift technology.
· Features to assist with 21 CFR part 11compliance Security, auditing and e-signature, CE, ISO, and MIQE compliant.
· System should detect differences in target quantity as small as 1.5-fold in single plex reactions, and should have 10 logs of linear dynamic range.
· The system should be able to do single-plate analysis, absolute and relative gene expression, SNP genotyping, presence/absence, high resolution melt, multiplate analysis gene expression studies, and SNP genotyping studies.
· The normalization of reaction due to non-PCR related fluctuations should be possible by using any calibrated dye.
· The system can be connected to the online ecosystem and instrument data/status will be automatically uploaded, allow users to access and securely share result with colleague anywhere, anytime from any location with internet access
· Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabilizer
· System should come TaqMan™ RNase P Instrument Verification Plate, Taqman fast reagents starter kit, Optical adhesive Covers starter kit & 96-Well Reaction PCR Plate.
· Should be provided with DNA extraction kits for 500 samples.
· Should be provided with RNA extraction kits for 500 samples.
· Should be provided with cDNA extraction kits for 500 samples.
· Should be provided with master mix. &TaqMan 500 reactions.
· Should be provided with online UPS with min 30 min power back-up and compatible branded desktop computer (12th Generation Intel Core i7/16GB/512 GB SSD/1TB HDD/Windows 11 Home/Intel HD Integrated Graphics, CD/DVD writer/reader, USB ports(4), at least 19.5” LED screen with color laser printer)
· CMC, AMC for at least 5 years with all technical support should be provided
· Should be supplied with microwave oven 32 liter (with digital display) with all accessories
· Should be provided two (02) sets of with single channel & variable volume Micro Pipettes (05 Nos.) with pipette stand: 0.1 - 2.5ul; 2-20ul; 10-100 ul; 20-200 ul and 100-1000 ul. Micro Pipettes should have 4 digit display for more accurate volume setting and easier volume identification. Without removing any parts, full pipette needs to withstand Autoclave sterilization at 121°C for 20 min. Pipette Volume Range with Volume Increments [0.1-2.5 ul – 0.002ul increment; 2-20ul – 0.01ul increment; 20-200ul – 0.2 ul increment; 100-100ul- 1 ul increment]. Pipette Piston with highly resistant to heat, acids and alkalis, mildew, bleaches, aging, sunlight and abrasion. Should have ultralight weight mechanical pipette. Micro Pipettes should have minimum 3 years warranty.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (26)
SI. NO. Specification of Autoclave
· Capacity:75ltrs,Vertical
· InnerDimension (Dia.xLength):16*24inch(400*600mm)
· OperationMode:Fullyautomatic(DigitalControllerwithAutomaticPressureRelease Valve)
· Construction:DoubleWalledInnerChamberStainlesssteel304
· Externalchamber:Stainlesssteel304LidStainlesssteel304
· Ring&Stand:Stainlesssteel304HeaterImmersionheater
· Gasket:Hightemperaturesiliconerubbergasket(Jointless)LockingsystemRadial locking mechanism w/ pedal lifting device
· Temperaturerange:121°Cto126°CTemperatureaccuracy±1°C
· Temperaturesensor:PT100
o Digitaltemperaturecontroller
o In-builtdigitaltimer0-60minutes
o ENDofsterilizationbuzzeralert
o Digitaldisplay ofpressure
o Sensorbroken indication
· Pressure:15to20psi
· Steamrelease:Automaticsteamrelease aftersterilization
· Releasevalve:Solenoid valve
· Pressuredisplay:Dialtypepressuregauge
· Pressurecontrol:Automaticpressurecontrolswitch
o Overpressuresafetyvalve
o Automaticvacuumbreaker
o Lowwaterlevelcut-off sensor
· Basket:Wiremeshbasket
· Powersupply:220Volts50Hz
· WaterInletValve
· No,Directly pourinto thechamber
· Standard accessories
Waterlevelindicator(glass)
o Water drain valve
· Warranty:5years
o Should be supplied with Heating and Drying Oven with following specification:
· Convectiontechnology:Gravity convection
· Temperaturerange °C:50°C-250°C
· Spatialtemperaturedeviation at150 °C:± 4.0 °C
· Temperaturedeviationovertimeat150°C:±0.4 °C
· Footprintm2 / sqft:0.3 /3.2
· ChambervolumeL / cubicft: 60 to 80 / 2.3 to3.3
· Exteriordimension, in (WxH x D):21.0x 30.0x 23.0 Approx
· Numberofshelves supplied / max : 2 / 12
· Max.shelf load kg/ lb:25 / 55
· Ratedvoltage/ frequency V / Hz: 230 / 50
· Energyconsumptionat150°CW: 200
· Lowenergy consumption.
· Builtintimer, Excellent footprint/volumeratio.
· Innerchambersmadefromcorrosion-resistantstainlesssteelwithroundedcorners for easy cleaning.
· Large, easytoviewvacuumfluorescentdisplay.
· Doorscan beopenedover 180°making theseunits easy to access.
· Simple,microprocessor-basedtouchbutton controls.
· Automaticovertemperaturealarmsystemtoprotectsamples.
· RS232Interface.
· Promptandefficientafter salesserviceshouldbeavailable.
· Warranty: 3YearsandCMCwithtechnical supportandservicefor5 years
o ShouldbesuppliedwithDigitalWaterBath:
Ø Microprocessorbaseddigitalprecisionwaterbathwithsmallerfootprint, frees up valuable benchtop space.
Ø Advancedmicroprocessorcontrollerisdesignedforextended functionality.
Ø Protectyourworkwithaudiblealarms.
Convenientlysavecommonlyusedsettingswithfourtemperaturepresets
Ø Bathscomewithclearpolycarbonategablecover,diffusertray,drainhoseand rubber duck .
Ø ULListedandCEMarked;USFDAClassIMedicalDevice.
Ø Over-temperaturesafety circuitryisdesignedtopreventthermal runaway.
Ø Outstanding chemical and corrosion resistance with epoxy powder-coated exterior,andeasilycleanthechamberwithitsseamlessstainlesssteelinterior.
Ø Designedto maintainwatertemperaturefromambient to 100°C.
Ø Icon-basedgraphicaldisplayforeasyoperationandmonitoring.
Ø Chambercapacity 20-25Liters.
Ø TemperatureStability±0.1°CandUniformity±0.2°C@37°C
Ø HeaterOutput:1200W
Ø PowerSupply:230V,50Hz
Ø Promptandefficientaftersalesserviceshouldbe available.
Ø QuotedModel’sspecificationshouldbeavailableintheManufacturer’s Website
Ø Warranty:3YearsandCMCwithtechnicalsupportandservicefor5years
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (27)
SI. NO. Specification of Feed Sterilizer
· Rectangular Horizontal Single Door Steam Sterilizer (Autoclave) to autoclave cages, water bottles, animal feed and animal bedding
· Inner Chamber dimension should be approximately 600 mm (width) X 600 mm (Height) X 1200 mm (depth)
· Chamber, jacket and doors should be made of high quality (316 grades) stainless steel
· Steam jacket: MS Boiler/SS 304 >10 mm thickness
· Door: Thick Stainless Steel door >15mm thick
· Should have safety pressure release valves for chamber and jacket
· Resin bounded glass wool/Rockwool slab insulation
· Should be supplied with a steam generator
· Should have digital temperature, pressure and time control unit
· Piping and other fittings should be constructed of high quality 316 grade SS
· Gasket: Silicon jointless
· Should have pneumatic valve
· Should have GM ejector for fast drying
· Sterilization programs for solid material, with adjustable temperature between 121 °C and 125°C
· Approximate Dimension: Size 750 [W] x 750 [H] x 1200 [D]
· Complete installation on turnkey basis depending on the available space
· Regulatory Compliance: Should be CE FDA/BIS/ISO approved product
· Should be supplied with all the essential accessories required for its functioning
· Vendor should quote for 5 years CMC including technical support and services free.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (28)
SI. NO. Specification of Compound microscope with camera and recording system
· Equipment: Complete microscope sstand with smart control box for transmitted light brightfield, phase contrast and fluorescence RGB-UV. ( Upgradeable to DIC and incubation setup)
· Application: Bright field, Phase contrast and Fluorescence Microscopy (Upgradeable to DIC for glass and plastic dishes).
· Operation: Smart Control Box - for stand-alone operation (without PC) of microscope stand functions with camera via On Screen Display and use with software (Windows and iOS) - Automatic features for camera control, Image enhancement functions and readout of encoded microscope functions - Provided interfaces: HDMI, USB 3.0 Type-C and Type-A, USB 2.0 Type- A, Ethernet, Micro-D - Wi-Fi compatibility via USB Wi-Fi adapter and router -
Phosphorescence block filter
Light manager for TL and RL
· Snap buttons on both sides of microscope stand
· Dust cover to be provided
TL Illumination: Lifetime TL/FL-LEDs (60k hours)
Carrier transmitted-light illumination with white LED 10W
· Mechainical stage: Specimen stage 232x230 mm with hardcoat anodized surface - Object guide
Universal mounting frame for slides and petri dishes.
· Nose piece: Encoded 6 position DIC nosepiece
· Objectives: LD Objectives – 5x/0.15 Ph , 10x/0.25 Ph , 20x/0.35 Ph , 40x/0.55 Ph and Semi-apochromatic objectives –LD – 20X/0.4 and LD – 40x/0.6
· Condenser: LD condenser 0.3for H, Ph, DIC for glass and plastic - rotatable, with click stops 0°, 90°, 180°, 270° - - 72 mm working distance - aperture stop.
· Filters: Encoded 6 position reflector turret.
· Fluorescence attachment: Solid-State Light source Type RGB-UV 4-channel fluorescence light source with integrated control unit in microscope continuous brightness adjustment, quickly switchable and adjustable by stand - Equipped with 4 solid state LED lamps. - Red (625 nm) for excitation of Cy5, Alexa 631, TOTO-3 and similar dyes - Green (565 nm) for excitation of Cy3, TRITC, DsRed and similar dyes - Blue (470 nm) for excitation of eGFP, Fluo4, FITC and similar dyes - UV (385nm) for excitation of DAPI, Alexa 405, Hoechst 33258
Dedicated Band pass filters for RGB to be provided (EX BP 470/40, BS FT 495, EM BP 525/50 , EX BP 550/25, BS FT 570, EM BP 605/70, BP 390/40, BS FT 420, EM BP 450/40).
· Desktop: Should be provided compatible branded high end computer system/desktop computer (13th Generation Intel Core i11/16GB/1TB/ SSD/Windows 11 Home/Intel HD Integrated Graphics, UPS, CD/DVD writer/reader, USB ports (4), more than 27” LED screen with color laser printer). One external LED monitor (~43-45”) should be also provided. Should also be provided with online 1KVA UPS with minimum 60 min back-up.
· Camera: Microscopy Color Camera: 12 MP pixel colour camera with CMOS image sensor, Pixel size – 1.85 μm X 1.85 μm, exposure time 1 ms: with a frame rate of 30 fps with a passive cooling system. And should have interfaces – HDMI, USB 3.0 Type C, Ethernet, and Micro-D Full HD Resolution. The camera shall provide an on-screen display (OSD), that allows to control the camera without an extra controller/computer or software. In the OSD, camera parameters and the image file name shall be selected and adjusted via mouse and keyboard. Images should be stored conveniently on a USB flash drive. The camera should support both, the operation in stand-alone mode and in combination with a computer and software. The camera shall provide multiple setup possibilities to use it in a wireless mode. Wifi adapter should be provided with the camera. Microscope, camera & software should be from same manufacturer.
· Software: Software for Windows / iOS / Android easy-to-use imaging software for the connected microscope and camera with following functions are included: - Image acquisition - Microscope/camera control (encoded components) - Microscope configuration - Image processing - Measurement and annotation - File management - Reporting and sharing - Multi Channel Fluorescence (MCF) for acquisition of fluorescence and transmitted light images in independent channels. - acquisition of up to 4 fluorescence channels + 1transmitted light channel - smart fluorescence channel overwrite - easy fluorescence channels setup with manual microscopes - compatibility with Smart Microscopy - multichannel view including image processing - report generation with MCF images -AI based cell confluency and AI cell counting.
· Certification and Quality: Microscope should have international quality standard certification like European CE, ISO, BIS, THE etc. Should be submitted along with technical bid. Schematic diagram of microscope should be provided.
· BINOCULAR MICROSCOPE:
· Upright compound microscope with Koehler Illumination
· Control Display
· 5-element display on either side of the stand and long-life blue LEDs. This intensity display is well readable from several meters distance.
· Contrasting Method
· LED illumination 3W white-light, 3200K, lifetime 25000 hours
· Homogeneous field illumination 20mm
· Microscope can perform plug-on swiveling mirror
· Optical system
· Color-corrected infinity optics
· A pair of eyepieces 10x suitable for spectacle wearers and retrofittable eyepiece pointer
· Eyepiece with field of view of 20mm
· Eyepieces secured with setscrews against unauthorized removal
· With High quality objectives of the Plan-Achromat class:
· Plan-Achromat 4x/0.10
· Plan-Achromat 10x/0.25
· Plan-Achromat 20x
· Plan-Achromat 40x/0.65
· 4-position nosepiece tilted back and objectives secured against unauthorized removal
· Optional accessory
· Plan-Achromat 100x/1.25 Oil, WD=0.14mm, incl. Immersion oil, 5ml
· With Abbe condenser 0.9/1.25
· Viewing with 30° angle and field of view 20mm
· Siedentopf "up and down" position for 2 different viewing heights
· With Interpupillary Distance continuously variable from 48 to 75 mm by asymmetric folding of the binocular part
· Tube is secured against dropping by special dovetail
· Mechanical reckless stage with Long-lived stage surface
· With well-readable vernier and robust controls
· Stage size 140x140, travel range 75x40
· Extremely stable stand to broad base and low center of gravity
· With power unit integrated into stand by way of a parking position with cable storage in the stand rear
· Wall. Ergonomic shape for convenient, safe carrying.
· With Wide-range power pack with country-specific power cable
· With IEC adapter for conversion into a bench-top power pack
· With external unit that is easy to change in case of defect
· With Power of 100-240V and 50-60Hz
· Carrying Handle
· With carrying handle that is completely integrated into stand
· With ergonomic shape for convenient and safe carrying
· With dust Cover
· Anti-fungus treated optics
· Must provide anti-fungus certification from manufacturer.
· 5 years CMC warranty
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (29)
SI. NO. Specification of Table Top Anesthesia System
1. Should be suitable for Mice, Rat, Guinea Pig & Rabbit. Anesthesia System should be provided with stand/ suitable trolley to move the system from one place to another.
2. Should provide continuous flow of gas anaesthesia during surgical procedures while actively scavenging away excess.
3. Should be provided with Mobile Anaesthesia System with Isoflurane Vaporizer; Active Gas Scavenger
4. Suitable Induction Chamber for Mice, Rat upto 500gm & Rabbit above 500gm.
5. Anaesthesia Systems should have configuration specifically for stereotaxic procedures.
6. Suitable Nose cone Mask for animal of weight range 15-50gm, 40 – 100gm, 100-300gm, 300 – 450gm & Mask for Rabbit.
7. Rodent Warmer and Cage Heating Pads should be provided.
8. Mobile Anaesthesia System with Isoflurane Vaporizer. In house facility of Vaporizer calibration should be available.
9. Isoflurane funnel-fill vaporizer with ideal flow meter range for rodents should be provided. Air pump flow rate 2.5 – 4.5 LPM, so that we can use the system in absence of Oxygen cylinder.
10. Should provide minimum 3 stations for anaesthesia with preset flow rate for any station (500cc-5 LPM). System should generate 50 LPM negative flow that can be attenuated to appropriate levels and divided between 3 stations.
11. Colour coded tubing and connector should be provided to help user identify which fresh gas supply tubing goes to which station.
12. Flip a toggle switch to “on” should start flow of fresh gas, indicator should confirm flow, without the need to adjust flow meters.
13. Mobile Anaesthesia System with Isoflurane Vaporizer. Inhouse facility of Vaporizer calibration should be available.
14. Isoflurane funnel-fill vaporizer with ideal flow meter range for rodents should be provided. Air pump flow rate 2.5 – 4.5 LPM, so that we can use the system in absence of Oxygen cylinder.
15. Should provide minimum 3 stations for anaesthesia with preset flow rate forany station (500cc-5 LPM). System should generate 50 LPM negative flowthat can be attenuated to appropriate levels and divided between 3 stations.
16. Colour coded tubing and connector should be provided to help user identify which fresh gas supply tubing goes to which station.
17. Flip a toggle switch to “on” should start flow of fresh gas, indicator should confirm flow, without the need to adjust flow meters.
18. Pressure gauge should be provided to let user know when pressure has been released from system for filling of vaporizer.
Active Gas Scavenger
Waste anaesthetic gases should be discharged into activated charcoalcanister or any non-re-circulating hood, vent, downdraft/ back draft systemor snorkel.
Continuous Induction Chamber
· Anaesthesia system should have a direct vacuum port to connect tothe Induction Chamber
· Adjustable negative flow meters easily activated with toggle switches shouldbe provided
· Available without negative flow generating pump should then be used toattenuate active, in-house vacuum source.
· Warranty should be 5 years and 3 years of CMC.
· All the above points should be mentioned with page number in technicalcompliance sheet
· Installation and demonstration with trained company staff at the customer point free of cost.
Should be supplied with Tabletop Auto CO2 euthanasia Assembly with following specification:
• Automated multi-stage control of gas flow and evacuation Automatic locking system.
• A single chamber system that can incorporateup to 8 Mouse Cages, 2 Rat Cages
• Automated Single Chamber System EA-285 Electrically Heated Regulator 25 - 125 CFH Output With Smartbox Side Control Box,
• Tabletop Chamber, Exhaust Blower, Exhaust Tubing, Two Hose Clamps, Mounted Timer Cart with 6” wheel, CO2 Cylinder
• Two preset times - adult and neonate
• Flow Rate: 10-30%
• Chamber Volume/minute
• Chamber Size: 9” L X 4” W x 4”H 11” L X 7” W x 6”H
• Compliant with AVMA Guidelines.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (30)
SI. NO. Specification of Individually Ventilated Cage (IVC)
· IVC for Mice: Qty 04
· General: Supply, Installation, Commissioning and Testing of “Mobile, Individually Ventilated Caging Systems (IVC) for housing Specific Pathogen Free (SPF) mice under aseptic conditions with bottle type drinking water arrangement. The IVC system should be as per the International Standards and Guidelines. Certification (ISO / CE etc.) /validation for the system are mandatory (including filter integrity test for HEPA filters). Voltage Requirement should be 200-240V (AC), single phase 50Hz
· Vendor should quote for 3 years AMC
· Air Handling Units (IVC Ventilator)
· Stand-alone type, capable of catering to 4 (four) single sided rack for mice with capacity of 40- 50 cages per rack Or 2(two) double sided rack with capacity of 80-100 cages per rack. HEPA filters and pre filters should be fitted on both supply and exhaust systems of AHU and the efficiency level of the filter should be 99.99% to prevent the entry of particles of more than 0.3micron size. HEPA filters should be DOP tested Air handling unit should provide 60 or more Air change/ hour. The system should have built in safety devices/ alarm indicating system failure, filter choking etc. It should have ability to signal alarms when temperature and relative humidity, supply airflow, exhaust airflow, air pressure etc., conditions set up by operator are breached. Provision for real time display of critical parameters like temperature, relative humidity, number of air changes per hour (ACH) etc. Also display HEPA life indicator as “%age” for HEPA filter life There must be a provision to discharge the exhaust air out of the room via a thimble connection or other and this shall be in the scope of the supplier IVC Rack must operate in both positive or negative pressure mode Noise level generated by the equipment should be less than 50 decibel.
· Air Handling Units (IVC Ventilator)
· Stand-alone type, capable of catering to 4 (four) single sided rack for mice with capacity of 40- 50 cages per rack Or 2(two) double sided rack with capacity of 80-100 cages per rack. HEPA filters and pre filters should be fitted on both supply and exhaust systems of AHU and the efficiency level of the filter should be 99.99% to prevent the entry of particles of more than 0.3micron size. HEPA filters should be DOP tested Air handling unit should provide 60 or more Air change/ hour. The system should have built in safety devices/ alarm indicating system failure, filter choking etc. It should have ability to signal alarms when temperature and relative humidity, supply airflow, exhaust airflow, air pressure etc., conditions set up by operator are breached. Provision for real time display of critical parameters like temperature, relative humidity, number of air changes per hour (ACH) etc. Also display HEPA life indicator as “%age” for HEPA filter life There must be a provision to discharge the exhaust air out of the room via a thimble connection or other and this shall be in the scope of the supplier IVC Rack must operate in both positive or negative pressure mode Noise level generated by the equipment should be less than 50 decibel.
· IVC cage rack for mice
· 4(four) no. single sided with capacity of 48 cages per rack .(Total cage capacity = 192). Four castor wheels with SS 304 casing and special grade nylon (or better quality) wheels for free moving and lockable type autoclavable wheel suitable for use in cage and rack washer.
· AHU/Ventilator: 01 no. Should have Facility for
· Disinfection- Should also have indication for PLC error on the control panel with analog mode facility in case of PLC (Display) failure.
· IVC cages and water bottle for mice
· Cages should be compatible with the IVC rack. Cages should be made of Polysulphone or better material with clarity/transparency capable of bearing frequent autoclave cycles. Caging accessories like cover grills, water bottles, label holders etc. should be included. Cage must be fitted with autoclavable silicon gasket either on the cage lid or tray for making the lid and tray locking airtight. Appropriate air filter/safety feature for animals to permit filtered air exchange in case of any system/power failure. Mice Cages should have a floor area and height as per national and international recommendations for housing mice (Minimum floor area- 500cm2).
· IVC for rat: Qty 04
· General: Supply, Installation, Commissioning and Testing of “Mobile, Individually Ventilated Caging Systems (IVC) for housing Specific Pathogen Free (SPF) rats under aseptic conditions with bottle type drinking water arrangement. The IVC system should be as per the International Standards and Guidelines. Certification (ISO / CE etc.) /validation for the system are mandatory (including filter integrity test for HEPA filters). Voltage Requirement should be 200-240V (AC), single phase 50Hz
· Vendor should quote for 3 years AMC
· Air Handling Unit:
· 04 (four) no. single sided with capacity of 30 cages per rack. (Total cage capacity = 120). Four castor wheels with SS 304 casing and special grade nylon (or better quality) wheels for free moving and lockable type autoclavable wheel suitable for use in cage and rack washer.
· Consists of AHU/Ventilator: 01no. Should have Facility for Disinfection. Should also have indication for PLC error on the control panel with analog mode facility in case of PLC (Display) failure.
· HEPA filters and pre filters should be fitted on both supply and exhaust systems of AHU and the efficiency level of the filter should be 99.99% to prevent the entry of particles of more than 0.3micron size. HEPA filters should be DOP tested Air handling unit should provide 60 or more Air change/ hour. The system should have built in safety devices/ alarm indicating system failure, filter choking etc. It should have ability to signal alarms when temperature and relative humidity, supply airflow, exhaust airflow, air pressure etc., conditions set up by operator are breached. Provision for real time display of critical parameters like temperature, relative humidity, number of air changes per hour (ACH) etc. Also display HEPA life indicator as “%age” for HEPA filter life There must be a provision to discharge the exhaust air out of the room via a thimble connection or other and this shall be in the scope of the supplier IVC Rack must operate in both positive or negative pressure mode Noise level generated by the equipment should be less than 50 decibel.
· Cages and Bottles:
· Total 160 cages with complete set of bottles, cage lid, grill and gasket. Cages should be made of Polysulphone or better material with clarity/transparency capable of bearing frequent autoclave cycles. Caging accessories like cover grills, water bottles, label holders etc. should be included The cage top should be fitted with appropriate and efficient gasket sealing -Appropriate air filter/safety feature for animals to permit filtered air exchange in case of any system/power failure. Rat Cages should have a floor as per national and international recommendations for housing rat (Minimum floor area- 800 cm2). Cage height: 14cm2 approx.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (31)
SI. NO. Specification of WaterPurifier
· Part 1: High Quality Pre Filter Before Main Units to counter the feed water contamination
· Manufactured by same equipment manufacturer submit catalogues mentioning below details.
· High quality Prefilter with Low pressure switch cuts off system which can able to take care high TDS upto 5000 ppm and high SDI up to 50 having 5 Micron and 1 Micron with DC diaphragm pump to boost water pressure from 0 to minimum 2.5 bar at approximately 120 L/Hr with noise levels of Less than 50 Db.
· Apart from prefilters two separate model should be there for Type-I and TYPE II systems.
· Part 2: Main Unit Lab Grade Water purification System (Type II)
· Feed water acceptance capability Specifications for main unit-
· Conductivity: up to 2000 μS/cm.
· Fouling Index (SDI): upto 12.
· Free Chlorine: upto 3 ppm.
· Temperature- 5-35°C.
· Product Water and main unit should meet or exceed Type II water quality
· Resistivity 5-15 Mega Ohms with Flow Rate - 3 Ltrs/Hr and TOC < 30 ppb
· Automatic Electro Deionization Module – With Carbon Beads at cathode which doesn’t required extra pre softening cartridges.
· System should have facility to control remotely with the help of software interface. All parameter like pressure, current, water rejection %, water product quality should be monitored in desktop or laptop. Attach screenshot of computer screen to validate it.
· No of Conductivity Cell in Type -II to ensure the Input& Output water quality- 3 Nos.
· Inside Type-II system Inbuilt Pretreatment Cartridge- 0.5 Micron filter, anti-scaling compounds and RFID tag must be there not as a optional.
· Pre-treatment pack contains silver-impregnated activated carbon which prevents the proliferation of Bacteria present in tap water; anti scaling compounds must to eliminate hardness and protect the RO membrane against oxidation, scaling and plugging.
· RFID Tag- for Traceability of pretreatment cartridge and every Liter throughput water volume should be seen on computer when connected thought LAN. Date of installation also be seen on computer. Attach screen shot to verify this feature.
· RO reject water recovery- up-to 50 %, before and after RO conductivity cell to know the % rejection of RO.
· In Type II system: - LCD Display must show all below parameter to understand the main system’s performance by the user itself.
· Tap water feed conductivity.
· RO feed water conductivity.
· RO water temperature.
· RO pump pressure.
· RO % rejection value.
· RO permeate water conductivity.
· 3 Way solenoid Valve- RO permeate is diverted to drain until the quality meets expectations. No. of Recovery loop – 1 Nos in type II system to save wastage of reject water.
· Specifications for Storage Reservoir
· Cylindrical tank Capacity minimum 30 Liter.
· Part 3: Ultra-Pure Water (Type I)
should meet or exceed:
· Product Water Quality Ultrapure (Type 1) water:
· Typical Water Delivery Flow Rate (L/min) ….2
· Ultrapure Water Resistivity (MΩ.cm at 25°C) - 18.2
· Microorganisms (cfu/mL) –end filter< 0.01
· Particulates< 0.22 μm (/mL) – with end filter< 1
· Pyrogen Levels (EU/mL) –< 0.001
· RNase Level (pg/mL) –< 1
· DNase Level (pg/mL) – < 5
· TOC (ppb) ...... ≤ 5 ( TOC indicator should be there)
· Proteases (μg/mL) < 0.15
· Recirculation loop- 1 number.
· The water system has a built-in UV lamp with emission at 185 nm and 254 nm wavelength. The lamp will operate for 2 years without replacement in order to reduce operating costs and the maintenance procedures.
· Two numbers of Polishing Cartridge of mixed bed resins should be there in Type-I system.
· The system will have a choice of minimum 6 point-of-use final filters on the water dispenser to support different applications. Submit details of all minimum six.
· The water Point-of-Delivery can be installed on a wall-mounted support for full flexibility of installation. The wall mounted configuration where the HMI and the Point of Delivery are fixed on the wall to a distance up to 3 meters. POD dispensing experience should be the same whatever the installation of the water purification system.
· At the Point-of-Delivery, basic information on water quality or anyalert / alarm information shouldbeshared.
· 7” large touchscreenwithbrightcolor LCD display compatible withgloves and wet or dry hands.
· Only one single inlinephoto-oxidation UV lampallowsboth to reduceorganics in ultrapure water and to measure TOC level.
· Inline TOC indicatorisbeingmeasure at the point of use and displayed on the touchscreenaftereach dispense.
· The water purification system is able to report the resistivity and conductivity in both temperature compensated and non-temperature compensated formats. The resistivity meters are able to be verified and calibrated on-site.
· The system can be connected to the local network via an Ethernet port and has a USB key port.
· Water dispensing reports record all dispensing parameters (water quality and volume, date and time). Dispensing reports can be stored without time limit.
· The volumetric water dispensing to deliver a specific water volume, from 100mL to 25L automatically (with 100 mL incremental). A quick volumetric dispensing is also accessible from a pre-set menu of customizable water volumes.
· Lab Close mode to saves energy and reduces wear of system components. The system automatically resumes hourly recirculation 24 hours prior to resuming lab activity, ensuring the system is ready for use.
· Check and dispense LEDs should be embedded on the support of the Point-of-Delivery, the key information is at the point of dispensing,
· Certifications for Water System from manufacturer :-
· CE certificates for Type I & Type II system with model name need to be submitted along with tender.
· CUL, FCC certificates Type I & Type II certificates need to be submitted along with tender.
· Mandatory Requirement:
· Minimum 10 appreciation letter clearly mentioning water purification system from any government organization in India.
· Minimum Install base 100 in India for water purification system with organization details with email id/ contact no.
· Service should be directly from the manufacturer’s engineer should be based at Kolkata, provide contact details. Call should be attended within 24 hours.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (32)
SI. NO. Specification of PortableUSG Machine
Portable Colour Doppler Ultrasound Machine2D ECHO
1. Should be top of the line and State of the Art fully digital portable ultrasound machine with provision for high resolution real time B
Mode, M-mode, colour Doppler, power Doppler and pulsed Doppler scanning modes. It should have Transient Elastography (TE)/ Controlled Attenuation Parameter (CAP) too.
2. It should be suitable and supplied with probe for abdominal, Obstetrics, Gynaecological, Cardiac Vascular, Thoracic, Transcranial, Musculoskeletal, Urological, Small Parts, for adults, paediatric (supplied with probe) and neonatal (supplied with probe) patient.
3. The unit should have a laptop type console design. The unit should be compact, lightweight and portable. Weight should not exceed 5.5 kg including battery (excluding cart and accessories) with quick boot of 30 seconds.
4. Provided with high quality, compact stand with lockable wheels and trolley should be having three probe connectors from the same company. The most recent model should be quoted.
5. Multiple preloaded as well as user configurable application presets should be available.
6. The system should have advanced measurement, manual and automatic for all applications.
7. The system should have minimum 100000 or more digital processing channels and 256 or more grey shades. Technical data sheet should be enclosed in technical bid to support the number of channels on the systems.
8. Maximum scanning depth to be 30 cm or more.
3. The system to have a dynamic range of 250 decibels or more.
4. System should support transducer technologies like phased array, convex, linear, hockey stick, microconvex and 4D volume etc.
5. Convex probe should be with either single crystal technology or pure wave technology or high density for excellent Image quality on Difficult to image patients. Please mention the above technology used in the transducer. System offered with normal transducers on convex are liable for rejection.
6. All transducer should be light weight digital phased array broadband type transducers.
7. Provision for inter-switchability between the transducers without the need of manual disconnection.
8. Display screen should be of atleast 15inches in size with high resolution colour LCD. The system should an integrated high resolution TFT/LCD of 15inches (flicker free images)or more.
9. Convex and linear transducers shall have detachable reusable biopsy guides for different gauge needles.
10. The system should have a frame rate of at least 600 frames per seconds (fps) in B mode and more than 300 fbs in Colour mode.
11. The system should have an ergonomic full alphanumeric soft keys keyboard with easy access scans control and trackball or touchpad.
12. The Systems should have cine loop review facility of not less than 60 sec/1000 frames.
13. System should have 500 GB or higher capacity internal HDD.
14. The system should have the facility of digital storage and retrieval of B/W and colour image data.
15. Provision for USB port and LAN transfer of data should also be present.
16. The system shall support the all DICOM functionality, Storage, Print, and Work List, also ready to connect to PACS.
17. Imaging modes of Real time 2D, Colour, Pulsed wave, Continuous Wave and Power (energy) Doppler, Anatomical M-Mode should be available.
18. Controls for 2D mode: Total gain, depth, TCG, dynamic range, acoustic power output.
19. Controls for Colour Doppler: PRF, colour gain, position and size of ROI, steering of ROI, colour maps and colour invert.
20. Controls for pushed Doppler: variable sample volume size from 1 to 5mm or more, steer, PRF, baseline, gain angle correction, spectral invert duplex on/off.
21. Measurements for 2D mode: Multiple distances, area and volume.
22. Measurement for Doppler modes: Stenosis quantification in area percentage, Diameter, PSV, EDV, means, PI, RI, acceleration time and index. Automatic and manual measurements and display of pulsed Doppler calculations should be possible.
23. Unit should function with 200-240 V, 50 Hz AC, 5-amp power outlet power requirement to be specified.
24. In built battery backup, should be at least 45 minutes or more. And should be supplied with compatible online UPS should be supplied which could support power backup for 45 minutes.
25. System should have both Triplex and Duplex display and a wide range of probes, increases system versatility and adaptability to our clinical needs.
26. System should be upgradable to Enhanced Needle Tracking, Panoramic Imaging and 3D software in future.
27. System should be upgradable to 3D/ 4D imaging
28. System should have capability to compare the current exam to the previous exam
29. System should have stain elastography
30. System should have continuous optimization the images when scanning different tissues
31. System should have onboard contextual reference tool
32. System should have capability for auto EF and stress echo
33. System should have facility to transfer images to an integrated CD writer/USB ports, without any interfacing.
34. Print– should have direct connectivity to printer for printing images.
35. System should be ICE Compatable.
36. The system must be US-FDA certified
System Must Be Supplied With the Following Transducers
1. Wide-band linear array transducer with 15.0–6.0 (±2) MHz Imaging Frequency for Intraoperative, vascular, musculoskeletal, nerve block, small parts, and pediatric patients
2. Wide-band hockeystick-linear array transducer with 13.0–5.0 (±1) MHz Imaging Frequency for Peripheral vascular, small parts, musculoskeletal, nerve blocks, superficial thoracic/pleural, needle guidance
3. Wide-band phased array transducer with 5.0–1.0 (±1) MHz Imaging Frequency for Adult and paediatric cardiac, abdomen, OB/GYN, thoracic/pleural
4. Wide-band convex array transducer with 5.5–2.0 (±1) MHz Imaging Frequency for Abdomen, OB/GYN, hip, spine, bladder, conventional musculoskeletal.
5. Phased array probe with basic cardiology package
6. Convex Probe 2- 5MHz +/- 1
System should be supplied with the following Accessories
1. Thermal B/W Printer.
Dockable cart must have at-least 3 Imaging universal active probe ports with electronic switching facility from key board without probe adapter.
2. Detachable, premium quality OEM Trolley/cart to mount transducers and machine.
3. When the machine is mounted on trolley, facility for connecting three transducers in standby mode with easy selection of active transducer should be possible.
4. Guarantee / Warranty: Comprehensive, on-site Warranty for 5 years covering main unit, transducers and all accessories supplied should be quoted.
5. CMC rates for subsequent 5 years (6th-10th year) including labour cost and cost of spare parts for whole equipment including all transducers and accessories should be quoted.
A free, comprehensive software upgrade (compatible with the existing platform) guarantee for 10 years must be provided.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (33)
SI. NO. Specification of PortableX-RayMachine
Digital Detector
· DetectorSize17inchesx17inches(wireless),14 inchesx17inches(wireless)
· Matrixsize2kx2k, 3kx3k
· Detectorstoragecapacitypreferably100imagesormore
Controlpanelforimageacquisition
· ControlpanelentryTouchscreen,Alphanumerickeyboard
· InbuiltconsoleshouldhavetouchTFTscreenandcontrol
XRAYGeneratorandTubes
· HighFrequencyX-rayGeneratorPowerinKw:6Kw,15Kw,50Kw,30Kw,32 Kw, 3.5 Kw, 40Kw,20Kw, 35 Kw KVrange40-125ormore,40-110,40-100
· MaximummA70@50KVP,100@40KVP,150@100KVP,200@100KVP, 400 @ 100 KVP Focalspot,mm0.8-2,0.5-1.2, 0.3-1
· HeatCapacity,KHU40-100,101-200,201-300
· AnodeTypeStationary,Rotating
· Anoderpm 3000 ormore forrotating, NAfor stationary
· CompatiblePCsystemwithaccessories andprinters
· Intelcorei7processor,512GBSDD,1TBHDD, 16GBRAM,27inchLED monitor
· Stitchinghardwareandsoftware
· DAPMetersupplied
· Lightweight‘zerolead’radiationprotectionapronsprovided
· Extractablemeasurabletapeshouldbeavailable
· Motorizedmovementforcompletemachine
Warranty 5years, CMC 5 years with at least all technical support
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (34)
SI. NO. Specification of Enzyme multiplied Immunoassay technique
Thefollowingspecificationsasawholeshouldbefulfilledwithallnecessarycompatible accessories:
o GeneralSpecificationsforMultimodeMicroplateReaderforenzymeandprotein related analysis:
• MicroplatereaderwithTandemdetectiontechnologywithSpectrometerbasedUV- Vis absorbance and filter based fluorescence intensity, FRET, TRF, Luminescence
• MeasurementModeslikeEndpointandKineticmeasurements,SequentialMulti Excitation measurements / Multi Emission measurements,
• Well Scanning mode with 900 data points per well, 3-D profile of the well, individualreadingandstatisticalanalysislikeaverage,Sum,Min,Max,etc.
• ShouldbecompatiblewithallSBSformat6to384‐wellMicroplates.
• Temperaturecontrolfromambient+3°Cto45°C
• ReadTimes Flying mode:<10 secfor 96well plates &<18secfor 384-well plates.
• Linearandorbitalshakingmodeswithuser‐definabletimeandspeed
o UV-VisAbsorbancemodespecifications:
• WavelengthRange:220‐1000nm,ODrange:0to4OD
• Lightsource:High-energylong-lifeXenonflash lamp
• Detector:CCDbased advanced Spectrometer
• ScanSpeed:shouldbepossibletoscanfullwavelengthspectruminlessthan1 sec/well.
• Shouldbepossibletosetscanbetween220–1000nmwithoutlimitationonnumber of data points.
• Accuracy:±1%at2OD&Precision:±0.5%at1ODand±0.8%at>2OD Pathlength correction to normalize to standard ODs at 10mm.
o FluorescenceIntensity/TRFMode:
• WavelengthRange:240‐740nm
• Lightsource:High-energylong-lifeXenonflash lamp
• Detector:DualPhotomultiplierTube(PMT)forsimultaneousemissiondetection
• Topandbottomreadingshouldbepossible.
• Wavelengthselection:onlybyopticalFilterswithon-board6-8positionseachfor Excitationandemissionfiltersonthewheel/slider.Aminimumoffourexcitation and four emission filters should be supplied.
• Sensitivity:Fluorescenceintensity:betterthan0.2fmol/wellfluorescein, 384sv,20μL
• TRFmodebetterthan30amol/wellEuropium
• Gaincontrol: Automatic gainadjustmentandsoftwareselectable.
o LuminescenceMode
• WavelengthRange:240‐740nm
• Detector:Photomultipliertube
• Topandbottomreadingshouldbepossible.
• Wavelengthselectionbyselectivefiltershouldbe possible.
• Sensitivity:20 amol/wellATP
• Shouldbepossibletoupgradeforon-boardhaveuptotworeagentinjectorsto dispense reagents and initiate kinetic events
o Control& DataAnalysis Software
• License‐freesoftwarepossibletoinstallonmultiplecomputers.
• CompliantwithUSFDAregulation21CFRPart11
• ShouldbepossibletocreateUSERS,setpasswordsandselectpathfordata storage.
• Shouldbepossibletocreateshortcuticonsfor frequentlyused protocols.
• Versatilekineticsoftwarefeaturesforendpoint,long‐termandfastkinetic measurement
• Real‐timekineticmonitoringshouldbepossible.
• Templatemanagerfortransferringstandards,buildingcomplexdataprocessing protocols and using default templates.
• CalculationbasedonStandardCurves,Userdefinedformulas,Ratiometric analysis, etc.
• Warranty:5 year fromthedateof installation
• Suppliedwith:DesktopcomputerwithInteli3processor,8GBRAM,500GB SSD, 18” Monitor, Keyboard, Mouse,
• Windows11OS withcolorlaser printer.
o Shouldbesupplied withone IceMachine withthefollowingtechnical Specification:
1. Iceproductioncapacity: 40-50kgsper24 hours.
2. Storagebin:15-20kg.
3. Iceholdingtankshouldbemadeupofstainless steel,insulatedwithPUF sothatice can be stored for longer period without melting.
4. Shouldhaveautocut offincaseofwatersupplyfailureandmaximumice level.
5. Overflowanddrainlinesshouldbeprovidedfor continuousdrainingofwater.
6. Noiselevel:≤50-60 Db.
7. Warranty:5years;CMCfor5yearswithalltechnicalsupportand freeservices
o Should be supplied with one DRY Ice (CO2 ice) making machine with the following technical Specification:
Production capacity: 400 kg/h (880 lb/h)
• Voltage 480V/ 60 Hz/ 3 Ph+PE (othervoltageavailableon request)
Dimensions(LxWxH) 2540×1100×3750mm(100x44x148 in)
- 1.700kg (3.740 lb) (withouthydraulicoil / options)
- 1.900kg(4.180 lb)(withhydraulicoil)
Weightpacked:2.300kg(5.060 lb)(withhydraulicoil)
Averagepowerconsumption 6 kW(8 HP)
• Noise levelBP420istandard92dB(A)
• CO2 inlet connection
- 1x1/2"BSPfemaleCO2 liquid
- 1x1/4"BSPfemaleCO2 gas
• CO2source:CO2storagetank, liquidphase(15-20 bar) (218-290 psi)
• Connectivity:Remoteaccessanddataservices:LAN,Ethernet,3G(otherdataservices on demand)
• Warranty: 5 years; CMC for 5 years with all technical support and services free-of- cost
• Shouldsuppliedwithtwoinsulatedcarrierboxes
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (35)
SI. NO. Specification of Extraction equipment–solid phaseextractor, liquid phase, Protein Precipitation
1) Chemiluminescent Documentation Systems should image and analyse chemiluminescent western blots and stained Protein (Coomassie, silver, sypro, etc), DNA (EtBr, Sybr, etc) gels, colony plates, 2D strips, TLC plates and with Fluorescent imaging across 5 separate channels with RGB (Visible range), and near IR fluorophores (e.g., Alexa Fluor™ and Alexa Fluor Plus, DyLight™ dyes) with up to 4 channel multiplexing option.
2) Camera: True 16-bit cooled 8.4megapixel or more high efficiency low noise CCD sensor with -30 ºC below ambient temperature.
3) System interface: Touchscreen at least 12-inch display, Fully automated operation
4) Motorized and Fully Automatic fixed lens with f-stop of 0.95 or better
5) The system should have Auto-focus for each level of zoom& Auto-exposure capability. It should automatically take the best focus according to the sample.
6) Dynamic range: System should have equal or more than 4.0 orders of magnitude
7) Illumination: Systems should utilize a transilluminator based on green LED, which effectively excites popular DNA dyes such as ethidium bromide and SYBR and one epi white LED
8) Exposure time: 1 millisecond to 60 minutes or more System should possess built-in roll out LED transilluminator with sample view stage size of 22cm x 18 cm or more
9) System should eliminate uneven light illumination
10) Filter Wheel and filters: Minimum 12 position motorized filter wheel for capturing images
11) It should have Epi white light and Epi IR light source with 5 colour fluorescence and 4 colour multiplexing.
12) System should have images in TIFF, JPG, PNG & PDF formats
13) System should allow series capture for creating series of images over different time period
14) System should have option to rotate sample blot/gel mechanically through software before capturing the images.
15) System should offer various binning option modes ranging from 1x1 to 8x8 for customized sensitivity/resolution.
16) System should have built-in algorithms that can identify multiple analysis frames and then assigns and quantifies lanes and bands for each analysis frame independently to allow multiple gels or membranes to be imaged and analyzed simultaneously with minimal user input and manipulation.
17) Automatic generation of customization report containing channel images, tables reporting band intensity, size, density, background etc with automatic and manual detection of lanes and quantification of bands or regions. System should have option to analyse up to 4 mini gels simultaneously.
18) The system should have molecular weight marker (MWM) overlay feature to allow users to perform molecular weight determination using a colorimetric molecular weight marker in the membrane channel and combining it with the corresponding chemiluminescent image.
19) Image analysis Software should not have any requirement for license registration allowing multiple users to use the software with full functionality
20) Software should produce customizable reports with data organized as desired including Lane & Band identification with molecular weight estimation, relative quantitation, absolute quantitation and normalization using loading controls.
21) Should be provided compatible branded desktop computer (12th Generation Intel Core i7/16GB RAM/512 GB SSD/1TB HDD/genuine Windows 11 Home/Intel HD Integrated Graphics, genuine Microsoft Office package and other necessary software; compatible UPS for at least 30 minutes power back-up, CD/DVD writer/reader, USB ports (4), compatible 27 inch LED screen monitor, color laser printer with all necessary cables, accessories like ink toner, HDMI cable, power cord, etc.)
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (36)
SI. NO. Specification of Reagents and Solvents (Neurobehavioural testing system)
· Neurobehavioural testing system with software for recording and analysing neurobehavior parameters of small animals including rats and mice.
· Video Camera based activity monitoring system for small animal for the assessment of memory, anxiety, depression and other type of behaviour of the animal.
· Should be provided with USB Camera, USB Cable with vari-focal lens (2-10 mm), IR night light illuminator (compatible USB and type C cable system)
· The behaviour tracking system can able to work with sixteen cameras and thirty-two apparatus simultaneously i.e analogue, digital, fire wire, and USB CMOS and webcam camera.
· The system should consist of video-tracking software, USB CMOS camera with lens, USB cable of 15ft and can track any animal in any mazes (like, Y-maze, elevated plus maze, Barnes maze and others) with experimental protocol editing facility.
· The behaviour tracking software protocol should have the following options for selection like video source, apparatus, zones, ports, sequences, keys, switches, test settings & options, fields, stages, events & actions, calculations, analysis and result, report & data.
· The software should have the facility to create password protected individual id to comply with GLP and the save data should also be password protected.
· Should generate report in graph, text, excel spread sheet, track and occupancy plotting (heat map) for centre, head and body separately with immobility and freezing episode count.
· The tracking software should run at least ten years without any updating charges after the activation of the software license key.
· Software should have the ability to track the animal’s head, centre and tail and can also covered the animal with colour with animal movement orientation during animal behaviour tracking
· It should have the facility for sequence setting to detect specific transitions of the animal with in the apparatus and also have the facility to identify specific location in the apparatus.
· System should automatically score over hundred different parameters like total distance absolute turn angle, total distance travelled by animal’s head, animal body clock wise and anti-clockwise rotation, visited zone list, , no of rearing episode, grooming of the animal and Overall: distance, speed, direction, Zones: Latency to enter, time in, distance from. Mobility: Latencies, time mobile, mobile bouts, Sequences: Rotations, visit to zone in an order. Behaviours: Counts, durations, frequencies.
· Should be provided compatible branded desktop computer (12th Generation Intel Core i7/16GB/1TB/Windows 11 Home/Intel HD Integrated Graphics, UPS, CD/DVD writer/reader, USB ports(4), 23” LED screen with colorlaser printer)
· Warranty and CMC, all technical support, software upgradation at free-of-cost, solution of software corruption, bugs or reinstallation at free-of-charges for at least 5 years or lifetime, as applicable
· All compatible cables, accessories should be provided
· Demonstration of system before biding and procurement
The system should be provided with one Tail-flick Analgesia Apparatus (Analgesiometer) with the following specifications:
1. The Tail Flick Apparatus should automatically measure thermal nociceptive threshold in mice and rats.
2. The system should work as a standalone or connected to the PC
3. An adjustable infrared heat stimulus should be focused on the animal tail and reaction time that is time to flick should automatically been recorded by the system.
4. Latency time & Intensity should automatically exported to a memory stick, or through USB to Software
5. The reaction time of the animal should automatically determine to the nearest 0.1 second
6. Operating Temperature should be from10° to 40° C with read-out multifunctional graphic display
7. Infrared intensity should be adjustable and focused by an embodied parabolic mirror on the rat tail with in the interval of 01-99 (in one digit steps)
8. Latency time should displayed on the graphic display, in 0.1s steps
9. Power requirements should 85-264 VAC, 50-60Hz
10. Manuals (digital): Instruction manual-For step by step guide of working and recording process
11. CUB software should provide for both recording and analysis of data
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (37)
SI. NO. Specification of Ice-lined refrigera tor (ILR) / minus 20 degree Celsius Deep Freezer)
1. Refrigerator must have (1) hinged solid doors
2. Refrigerator must have Positive forced-air circulation
3. Refrigerator must have Automatic defrost system
4. Refrigerator must have Micro processor based Electronic Controller with 7 Segment LED display
5. Refrigerator must have Mercury-free LED interior lighting
6. Refrigerator must have externally mounted internal light switch
7. Refrigerator must have a capacity of 465 Liters capacity
8. Refrigerator must have a 1-minute door opening recovery of less than or equal to 8minutes
9. Refrigerator must have set off our casters standard and installed in factory
10. Refrigerator must have digital temperature display
11. Refrigerator must have a temperature resolution to 0.1°C
12. Refrigerator must have a temperature uniformity of 1.4°C or better
13. Refrigerator must have adjustable cold and warm alarms
14. Refrigerator must have both audible and visual alarms
15. Refrigerator must have door-ajar alarm and icon.
16. Refrigerator must have service alarm and icon
17. Refrigerator must have low battery alarm
18. Refrigerator must have (5) internal wire shelves
19. Refrigerator must have standard 1”rear access port standard
20. Refrigerator must have standard remote alarm terminals standard
21. Refrigerator must be CE certified
22. Refrigerator must incorporate Rodent proof power cord
23. Refrigerator must use environmentally friendly SNAP & F-GAS Compliant HC refrigerants
24. Refrigerator must operate at less than or equal to 55.1dba
25. Refrigerator must support a standard set table range of -25C to-15C
26. Refrigerator must include soft touch grip for full door length handle
27. Refrigerator must have Load Limit of 45kg (99.2lbs) per Shelf
28. Warranty and CMC for at least 5 years with all support and services free
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipment/IGIMS/Store
TECHNICAL BID SHEET
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
NAME OF WORK:- A (38)
SI. NO. Specification of Semi auto analyzer (semi-automatic biochemical analyzer)
1. Should be open integrated discrete, Automated, benchtop Random Access, walk away Clinical Chemistry Analyzer for Routine chemistries, Specific Proteins, Drugs of abuse testing, Therapeutic drugs monitoring and Immunosuppressant drugs testing.
2. Should be able to provide results for at least 350 Tests/hour, photometric tests.
3. US – FDA certificate to be submitted.
4. The reagent tray with on board cooling facility for all reagent, having more than 40 positions for reagents bottles and it should accept both 10mland 20ml bottles.
5. Continuous access to reagents should be there without interrupting test processing. Automatic identification via internal barcode reader. Clearly displayed real-time reagent volume and remaining test capacity. Up to four reagent additions per test.
6. Automatic upload of calibrator and control values to save time and reduce manual errors
7. Minimum reading volume should be 120 μL/test.
8. Sample volume should be in the range of 2-120 microliter (μL)
9. Reagent volume 2-240 microliter (μL)
10. It should have static photometric range from 340-700 nm with Single channel interference filter photometer with beam splitting reference, 12 filter positions.
11. Should have an ability to measure in the range from 0 - 3.5 A with resolution of 0.001 A and reproducibility of SD <0.005 A at 2 A.
12. Should have separate sample and reagent probes to dispense those as required. Should have mixer for the reagent & samples mixing in the reaction cuvette.
13. Must have single use disposable cuvettes to allow user, safe and contamination free analysis.
14. No external tubing should be there outside the analyzer, the analyzer must be self-contained with waste container for liquid waste and deionized water inside the analyzer.
15. Should have sample tray having more than 53 sample positions to accommodate primary tubes of 5ml, 7ml and 10ml or more than 106 sample positions to accommodate sample cups of 0.5ml and 2ml.
16. Operating and detailed service manual should be supplied.
17. Water requirement should not be more than 3 ltrs/hr.
18. The equipment should have Bidirectional interfacing facility for easy LIS connectivity.
19. Accessories: All software required for the functioning of the equipment should be provided along with equipment.
20. Accessories for reporting like, printer, ink, paper for printer, necessary cables,
21. Movable trolley or work station should be provided
22. Kits and reagents and other necessities for at least 200 samples each for phenytoin, carbamazepine, valproic acid, amitriptyline, tacrolimus, mycophenolate mofetil, olanzapine, sertraline, benzodiazepines etc. should be provided for at least 5 years batch by batch as demanded (not at the same time of installation to avoid wastage)
23. Warranty and CMC for 5 years with all technical support
24. CMC from 6th year to 10th year additionally provided
25. Extra pack of tubing solution, cleaning solution, tensile cuvettes, preventive maintenance kit, probe, tubing’s should be supplied to maintain the equipment and run the tests for 5 years
26. Compatible PC system
• Intel i7 processor, at least 16 GB RAM, 512 BG SSD and 1 TB HDD, DVD RW,
• Genuine inbuilt Windows 11 OS, LED Monitor 27”
• Compatible colour Laser printer
• Should be supplied with Online UPS with at least 30 minutes power back-up and compatible voltage stabilizer
• Laser Colour Printer along with accessories.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/2025-2026/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- A
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
LOCATED WITHIN INDIA.
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
EMAIL ID OF AGENCY
Scheduled Brief description of goods Make: Model: Country of origin Qty./Nos. Ex-factory/ Ex-warehouse/ Ex-Showroom/ off-the shelf (a) Excise duty (If any) % and value. (b) GST (If any) % and value (c) Pcaking and forwarding charge (d) Inland transportation, isurancer for a period inculing 3 months delivery, loading/unloading and incidental cost till consignee site. (e) Incidental services (Including installation and commissioning, supervision, demonstration and training) at the consignee site. (f) Unit Price( at consingee site basis (g) a+b+c+d+e+f Total unit price (at consignee site) Basis Rs. 4x5 (g)
TOTAL AMOUNT IN FIGURE
TOTAL AMOUNT IN WORDS
Note: Bidders are requested to submit price bid in above format otherwise the bid submitted will be regected.
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, SHEIKHPURA, PATNA-800014
NIT No. 35/ 2025-2026/Bio Medical Equipt/IGIMS/Store
NAME OF WORK:- A
EARNEST MONEY 2% of the Equipment
COST OF BOQ 2500
TENDER PROCESSING FEE 590
COMPREHINSIVE ANNUAL MAINTENANCE CONTRACT PRICES SCHEDULE
ADDRESS OF AGENCY
CONTACT NUMBER OF AGENCY
E-MAIL ID OF AGENCY
S. No. Item Description 1st Yr. 2nd Yr. 3rd Yr. 4th Yr. 5th Yr. Total Comprehensive annual maintenance contract over a period of five years after expiry of warranty period of five years from the date of successful installation. (c+d+e+f+g)
1 Name of the equipment Make: Model: Qty:
2 Name of the equipment Make: Model: Qty:
3 Name of the equipment Make: Model: Qty:
4 Name of the equipment Make: Model: Qty:
5 Name of the equipment Make: Model: Qty:
6 Name of the equipment Make: Model: Qty:
7 Name of the equipment Make: Model: Qty:
8 Name of the equipment Make: Model: Qty:
9 Name of the equipment Make: Model: Qty:
10 Name of the equipment Make: Model: Qty:
11 Name of the equipment Make: Model: Qty:
12 Name of the equipment Make: Model: Qty:
13 Name of the equipment Make: Model: Qty:
14 Name of the equipment Make: Model: Qty:
15 Name of the equipment Make: Model: Qty:
16 Name of the equipment Make: Model: Qty:
17 Name of the equipment Make: Model: Qty:
18 Name of the equipment Make: Model: Qty:
19 Name of the equipment Make: Model: Qty:
20 Name of the equipment Make: Model: Qty:
21 Name of the equipment Make: Model: Qty:
22 Name of the equipment Make: Model: Qty:
23 Name of the equipment Make: Model: Qty:
24 Name of the equipment Make: Model: Qty:
25 Name of the equipment Make: Model: Qty:
26 Name of the equipment Make: Model: Qty:
27 Name of the equipment Make: Model: Qty:
28 Name of the equipment Make: Model: Qty:
29 Name of the equipment Make: Model: Qty:
30 Name of the equipment Make: Model: Qty:
31 Name of the equipment Make: Model: Qty:
32 Name of the equipment Make: Model: Qty:
33 Name of the equipment Make: Model: Qty:
34 Name of the equipment Make: Model: Qty:
35 Name of the equipment Make: Model: Qty:
36 Name of the equipment Make: Model: Qty:
37 Name of the equipment Make: Model: Qty:
38 Name of the equipment Make: Model: Qty:
39 Name of the equipment Make: Model: Qty:
40 Name of the equipment Make: Model: Qty:
41 Name of the equipment Make: Model: Qty:
42 Name of the equipment Make: Model: Qty:
43 Name of the equipment Make: Model: Qty:
44 Name of the equipment Make: Model: Qty:
45 Name of the equipment Make: Model: Qty:
46 Name of the equipment Make: Model: Qty:
47 Name of the equipment Make: Model: Qty:
48 Name of the equipment Make: Model: Qty:
49 Name of the equipment Make: Model: Qty:
50 Name of the equipment Make: Model: Qty:
Scope of contrct (details as mentioned in the clause No. - 13 of "Instruction to Bidder" & Clauses No. 3,4 and 5 of Condition of Condition of Contract".)
a) The rate of Comprehensive Annual Maintenace Contract as mentioned above shoul cover the Complete system.
Complete System should include the basic unit and allied supporting components like UPS, stabilizer Computer System,
Printer, De-ionizer, dehumififer etc to be supplied by the bidder along with basic unit.
b) Preventifve maintenance visit: Four Maintenance visits at ragular interval for usual mintenance & supervision failing which
25% of the contract amount per visit would be deducted as penalty.
c) Break down maintenance visit: As & when requrd
d) Response Time: Within 48 Hours.
e) Uptime Guarantee: 95% of 365 days
f) The above-mentioned charges should includes labour charges for maifntenance and breakdown visits per year, spares,
accessories and all type of consumables requird for the maintenaed charges: it should be clearly mentiond with frequency of
replacement and with rate. The validity of rate of suchf items should also be mentioned vclearly. What will be the rate of
such item must be mentioned.
g) Payment of Comprehensive Annual Maintenance Contract would be made on half yearly basis after completion of work and
satisfctory working report . In no case, advance payment is to be considerd.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Bidding Doc..pdf
NIT • 1.52 MB
Technical Sheet.xls
NIT • 0.80 MB
Bidding Doc..pdf
NIT • 1.52 MB
TNo 35 2025-26 (1).pdf
NIT • 0.91 MB
BOQ.xls
NIT • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .