Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC Awarded as found L1 | |
| 2 | L2₹5.6 L+₹1.6 L (38.9%)Rejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹6.1 L+₹2.1 L (51.5%)Rejected-Finance B 16 280 KALYANI KALYANI NEAR KALYANI MUNICIPALITY NADIA WEST BENGAL 741235 | NADIA | WEST BENGAL | 741235 | L3 | Rejected-Finance Rejected as L3 | |
| 4 | Rejected-Technical 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | - | Rejected-Technical Shorfall not reponded. |
Tender Value
₹4.4 L
EMD Value
₹8,822
Closing Date
9 Oct 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE,SKHESD I
O/o The Assistant Engineer South Kolkata Health Electrical Sub Division-I, P.W.Dte. K.S.Ray T.B. Hospital, Jadavpur, Kolkata - 700 032
Emergent dismantling and re-installation of AC machines as urgent bsais for civil renovation work.
2025_WBPWD_897563_1
WBPWD/AE/SKHESD-I/NIQ-16/25-26
Open Tender
ELECTRICAL WORKS M/R
Item Rate
120 days
Baghajatin S.G Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,822
10 Dec 2025
2 Sept 2025
13 Oct 2025
2 Sept 2025
9 Oct 2025
9 Sept 2025
Amount
Charges for dismantle the 2.0/a.5 Tr split type AC machines and handing it over to the store house/ section house as per instruction of EIC.
Charges for dismantle the 2.0/a.5 Tr window type AC machines and handing it over to the store house/ section house as per instruction of EIC.
Charges for Re-installation, Testing, commissioning of split type 2.0 Ton Air-Condition machines including fixing of copper refrigerant pipe line for inter-connecting indoor and outdoor unit with necessary insulation tube including iron bracket (powder coated) and others necessary fixing arrangements after completion of civil renovation work by making suitable scaffolding arrangement as per site condition and mending the goood damages to original finish.
Installation, testing and commissioning of 1.5/2.0 Tr window AC including wood frame of required size and GI tray with proper fixing arrangement , initial gas charging and mending good the damages to original finish.
Supply and fixing of copper refrigerant pipe line with insulation tube heavy quality black nitrail rubber and cotton tape for inter-connecting indoor & outdoor unit as following size : 5/8" or 15mm dia copper pipe as per direction of EIC.
Supply and fixing of copper refrigerant pipe line with insulation tube heavy quality black nitrail rubber and cotton tape for inter-connecting indoor & outdoor unit as following size : 1/4" or 6.35mm dia copper pipe as per direction of EIC.
Supply & charging of extra R-32/R-410A Gas as per requirement.
Cost of PVC drain pipe laying.
S&F of 25 mm heavy type (40 Grade) UPVC pipe with necessary elbows,connector,solvent cement & clamps. (Make: Supreme)
Supply and fixing of MS bracket for AC machine outdoor unit.
Supply & drawing 3 core 2.5 sq. mm. P.V.C. insulated copper wire for connecting the Power hub to Outdoor unit supply. (Make KEI/Finolex/polycab /havells/ Gloster/ Heavels)
Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated wire for connecting the outdoor to indoor supply.(Make Finolex/RR Kabel /Gloster)
Cost for repairing of 90ft (L) X 3.3 ft(W) X 6ft(H) existing structure by supporting the base by 15 Nos. [50x50x6mm] x 3.8ft MS angle for Vertical support & 15 Nos. [50x50x6mm] x 4.5ft MS angle for cross support with repect of wall. Horizontal support and cross support should be welded with the existing structure. Also the structure supporting by [35 X 6mm] x 300ft flat bar for Horizontal with respect wall. These flat bar should be welded.Also need some patch repair to the existing structure. Those MS angle should be fixed on concrete wall by cutting hole & necessary masonary works and mending goods damages to original finish as per direction of EIC with scaffolding arrangement. MS Iron should be make by TATA/Jindal.[N/S]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for ODU and Structure installation, per storey of building per vertical run.
Terms and condition
The Agency must procure the materials from the Manufacturere/ OEM or from their authorised sales channel so that the standard warranty/ support of the Manufacturer/ OEM becomes applicable to the products to be delivered and installed by them.
Make & Model no of each and every materials to be approved by EIC.
Defect liability period 1(one) year.
ANIKET COOLING AND REFRIGERATION CO (BID ID -6936901)
REFRICON (BID ID -7018797)
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .