| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 LAccepted-Finance 2 222 B 10 PONMAGAR METTUR DAM 636 401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | 1 | Accepted-Finance satisfied | |
| 2 | 2₹5.2 L+₹24,415.80 (4.97%)Accepted-Finance 3 140 H 1 PERIYAR STREET AMMAN NAGAR METTUR DAM 636 401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | 2 | Accepted-Finance satisfied |
| Sl No | Description | Qty | Unit | SS ENGINEERING CONTRACTOR L2 | PREETHI ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for removal of RC valve in CWP 3A, 3B & 3C of size 200 mm along with R.C. pipe and manhole door and fitting the same after completion of work. | 3 | Nos | 15,500 ₹46,500 | 14,750 ₹44,250 Lowest |
| 2.00 | Charges for checking and Renewal of Nitrile rubber Seal in 1600 mm Butterfly valve in Cooling Water Pump 3A, 3B & 3C in the discharge lines and if necessary / renewal of seal clamping pad, rethreading of worn-out threads in the seal mounting disc and clamping the seal with the disc. Checking the open / close operation of 1600 mm butterfly valves of Cooling Water Pumps 3A, 3B & 3C. | 3 | Nos | 11,000 ₹33,000 | 10,800 ₹32,400 Lowest |
| 3.00 | Charges for overhauling of 1 No. (out of 3A, 3B & 3C) gear box assembly of 1600 mm B.F.V, including removal of Actuator, dismantling the gear box assembly, inspection if necessary / renewal of spare and reassembling the same. | 1 | No | 20,600 ₹20,600 | 20,300 ₹20,300 Lowest |
| 4.00 | Charges for overhauling of 1No BFV of size 1600 mm (which will be taken up for gearbox overhauling) including dismantling the bearing assembly at both ends inspection, if necessary / renewal of spares and reassembling Butter fly valve size 1600 mm. | 1 | No. | 40,900 ₹40,900 | 40,600 ₹40,600 Lowest |
| 5.00 | Charges for lifting the CWPs intake screen, positioning, cleaning the debris and algae and placing the screens in its position after completion of painting works. | 3 | Set (1 set consist of 3 Nos) | 12,500 ₹37,500 | 11,900 ₹35,700 Lowest |
| 6.00 | Charges for cutting and removal of existing eroded / corroded portion of the bolt fixing area of the 3 Nos. CWP intake screen. | 113 | Kg | 7 ₹791 | 6.4 ₹723.2 Lowest |
| 7.00 | Charges for petty iron works for fabrication of MS plate of size 200x200x10 mm and welding the MS plate in the bolt fixing area of the 3 Nos. CWP intake screens. | 119 | Kg | 60 ₹7,140 | 57 ₹6,783 Lowest |
| 8.00 | Charges for dismantling the existing half round S.S. wire mesh with the frame structure of two halves of condenser ball catcher assembly provided over the Flow Control Valve in Cooling Tower and place the C.B. catcher assembly on the fan floor to facilitate for O/H of Flow Control Valve and 12 reassembly the condenser ball catcher assembly over the FCV. | 12 | Nos | 2,250 ₹27,000 | 2,185 ₹26,220 Lowest |
| 9.00 | Charges for dismantling of existing deteriorated 500 mm dia Disc type angular valve assembly from respective hot water pipe nozzle, cleaning the pipe nozzle flange surface, lifting, positioning, and reassembling the valve. | 12 | Nos | 8,950 ₹1,07,400 | 8,080 ₹96,960 Lowest |
| 10.00 | Charges for dismantling, cleaning & examining of valve internal components and renewal of other worn out components such as spindle support with bush / disc support M.S. bush by cutting, removing and welding with new M.S. bush, removing the existing damaged & worn out rubber seal of the disc, cleaning and fixing the new rubber seal over the disc by using proper adhesives if necessary, and reassembling and re-commissioning of the valves in the hot water pipe lines of Cooling Tower - III. | 12 | Nos | 5,000 ₹60,000 | 4,780 ₹57,360 Lowest |
Tender Value
Refer Docs
EMD Value
₹5,300
Closing Date
15 Sept 2026, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I CA CWS II Unit III Overhauling of 1600 mm BFV in CWP discharge line including Actuator Gearbox Overhauling checking renewal of Nitrile rubber seal Replacement of eroded corroded portion of bolt fixing area in Intake Screens of CWPs 3A 3B 3C
2026_EB_701849_1
CE/MTPS-I/SE/M-I/CA/OT. 40 /2026-27
Open Tender
Power/Energy Projects/Products
Works
15 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specification
4 documents required · 4 mandatory
₹0
₹5,300
Yes
16 Sept 2026
9 Sept 2026
16 Sept 2026
9 Sept 2026
15 Sept 2026
9 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for removal of RC valve in CWP 3A, 3B & 3C of size 200 mm along with R.C. pipe and manhole door and fitting the same after completion of work. | 3 | Nos | - | - |
| 2 | Charges for checking and Renewal of Nitrile rubber Seal in 1600 mm Butterfly valve in Cooling Water Pump 3A, 3B & 3C in the discharge lines and if necessary / renewal of seal clamping pad, rethreading of worn-out threads in the seal mounting disc and clamping the seal with the disc. Checking the open / close operation of 1600 mm butterfly valves of Cooling Water Pumps 3A, 3B & 3C. | 3 | Nos | - | - |
| 3 | Charges for overhauling of 1 No. (out of 3A, 3B & 3C) gear box assembly of 1600 mm B.F.V, including removal of Actuator, dismantling the gear box assembly, inspection if necessary / renewal of spare and reassembling the same. | 1 | No | - | - |
| 4 | Charges for overhauling of 1No BFV of size 1600 mm (which will be taken up for gearbox overhauling) including dismantling the bearing assembly at both ends inspection, if necessary / renewal of spares and reassembling Butter fly valve size 1600 mm. | 1 | No. | - | - |
| 5 | Charges for lifting the CWPs intake screen, positioning, cleaning the debris and algae and placing the screens in its position after completion of painting works. | 3 | Set (1 set consist of 3 Nos) | - | - |
| 6 | Charges for cutting and removal of existing eroded / corroded portion of the bolt fixing area of the 3 Nos. CWP intake screen. | 113 | Kg | - | - |
| 7 | Charges for petty iron works for fabrication of MS plate of size 200x200x10 mm and welding the MS plate in the bolt fixing area of the 3 Nos. CWP intake screens. | 119 | Kg | - | - |
| 8 | Charges for dismantling the existing half round S.S. wire mesh with the frame structure of two halves of condenser ball catcher assembly provided over the Flow Control Valve in Cooling Tower and place the C.B. catcher assembly on the fan floor to facilitate for O/H of Flow Control Valve and 12 reassembly the condenser ball catcher assembly over the FCV. | 12 | Nos | - | - |
| 9 | Charges for dismantling of existing deteriorated 500 mm dia Disc type angular valve assembly from respective hot water pipe nozzle, cleaning the pipe nozzle flange surface, lifting, positioning, and reassembling the valve. | 12 | Nos | - | - |
| 10 | Charges for dismantling, cleaning & examining of valve internal components and renewal of other worn out components such as spindle support with bush / disc support M.S. bush by cutting, removing and welding with new M.S. bush, removing the existing damaged & worn out rubber seal of the disc, cleaning and fixing the new rubber seal over the disc by using proper adhesives if necessary, and reassembling and re-commissioning of the valves in the hot water pipe lines of Cooling Tower - III. | 12 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_843940.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .