Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.5 LAccepted-AOC | ₹2.5 L | 1 | Accepted-AOC Most responsive bidder. The buyer selects the most suitable bidder for the contract based on the overall evaluation. |
Tender Value
₹2.8 L
EMD Value
₹5,584
Closing Date
1 Mar 2025, 4:00 pmClosed
Executive Engineer (E)
BSNL Electrical Division, Kharagpur Old DTO Building, BOGDA Kharagpur
SITC of Outdoor type LT Feeder Pillar for Power Feeding arrangement at Telecom Factory- Kharagpur
2025_BSNL_226772_1
54/BSNL/ED/KGP/2024-25
Open Tender
Electrical Works
Item Rate
60 days
TF Kharagpur
As per NIT
2 documents required · 2 mandatory
₹590
Yes
The Account Officer, (Cash) O/o the G.M.T ,BSNL, K
₹5,584
Yes
26 Apr 2025
20 Feb 2025
3 Mar 2025
20 Feb 2025
1 Mar 2025
20 Feb 2025
20 Feb 2025 - 1 Mar 2025
Supplying, installation, testing & commissioning of Out Door Type Double Door weather-proof cubicle of LT feeder pillar with Degree of Protection-IP 43 in accordance with IS-2147, floor mounting type,suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system complete as per detailed specifications and drawing attached , fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 1000 Amp capacity extensible type FP aluminum alloy bus bars of height conductivity, bus bar supports, cable alley with bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.0 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half. The compartments and cable alley section shall be protected by rubber gaskets, dust and vermin proof , suitable ventilation system with wire net guards , neutral link, etc. i /c providing following switch gears, making interconnection complete as required 1.Size : (1.150(H) x 1.250(W) x .450(D) approx 2.The top of pillar shall be fitted with a sloping canopy, the design of which shall be such that rain water shall not accumulate on the top. 3.Air ventilation arrangement shall be provided at all sides of the enclosure to facilitate air circulation 4.The Pillar shall be provided with removable split type base plate fitted with rubber grommets for cable entryto facilitate cable jointing. 5.Proper support shall be provided for holding I/C& O/G cables. These, cable support arrangement shall be provided to take the load of the cable. 6.The Busbar of all phases and neutral shall be provided with colour coded heat shrinkable insulation sleeves. Phase barriers shall be provided between the Busbars and all Busbars shall be in two equal sections with removable link. 7.Panel Construction Free Standing floor mounted with steel frame, 8.The supplier shall submit their own drawing for approval of the competent authority before manufacturing.
Incoming : [Supplying and fixing of 630 Amp 4 pole MCCB having breaking capacity 36 KA (Icu=Ics) along with set of Phase Spreader terminals (set of 4) including connection testing etc as required ( Make L &T DN630N or S.S Make )= 2 Nos.
Extended Rotary Handle- 2 Nos
Electrical-Mechanical Interlocking between both incomer
On/ OFF indication on Incomer Feeder
Outgoing : 4 Pole 1000A 4Strip Al .Bus Bar with heat shrinkable coloured sleeves and i/c bus bar cross section supports & their spacing etc. Max. current density of Al Bus-bar =1 Amp/sqmm.The Bus-bar of all phases and neutral shall be provided with colour coded heat shrinkable insulation sleeves. Phase barriers shall be provided between the Busbars and all Busbars shall be in two equal sections with removable link.
Interconnection Metering and Indication :
Digital Amp Meter & Voltmeter With 600/5 CT
Phase indicator
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3 ½ C X 240 sq. mm (62mm)
Dressing of 3 ½ C X 240 sq. mm XLPE Aluminiun Armoured Cable ( i/c clamped with 40x3mm MS flat clamp) in Surface of Wall & with Existing Cable trays
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .