Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.1 L+₹39,560 (3.12%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹15.6 L+₹3.0 L (23.3%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹16.0 L+₹3.3 L (26.1%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹16.8 L+₹4.2 L (32.9%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
9 Mar 2020, 6:00 pmClosed
SH M V SANKAR SE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINTENANCE OF INTERNAL WIRING INDUCING REPLACEMENT OF U S MCBs DBs LIGHT FITTINGS FOR BLDGS AT VARUNAPURI I II AND UWR UNDER AGE EM II OF GE NW VASCO
2020_MES_320119_1
85228/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹32,000
Yes
1 May 2020
30 Jan 2020
11 Mar 2020
30 Jan 2020
9 Mar 2020
17 Feb 2020
Amount
Taking down aluminium/copper point wiring (light, socket or power ) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials (credit for above items should be made as per conditions separately) and making good the disturbed surface all as specified and as directed .
Taking down sub main wiring aluminium/ copper of any size including earth continuity conductor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Taking down existing DB TPN 4 way and DB SPN 8 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M &L Point wiring complete with 1100volt grade PVC insulated unsheathed multi stranded 1.5 sq mm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sq mm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches, sockets etc concealed on wall complete all as specified and as directed.
(a) One light point/fan point controlled by one switch
(b) One call bell point controlled by bell push
(c) One 3 pin socket outlet, on the same board with other switches with cable 1.5 sq mm
(d) One 3 pin socket outlet, 5 Amps on independent board.
(e) one light point controlled by two, two way switches.
All as per Item No 4 here in before but complete with 1100volt grade PVC insulated unsheathed multi stranded wire with 2.5 sq mm copper cable through casing and capping of suitable size and one run of 2.5 sq mm copper cable as earth continuity conductor including connecting with earth dolly for 15 Amps socket outlet on independent board all as specified and as directed.
S & F Switch piano, flush type single pole, one way 5 Amp all as specified and as directed.
S &F Switch piano, flush type single pole, two way 5 Amp all as specified and as directed .
S & F in repair switch socket combination 2 in 1, 3 pin 5 Amp and 2 pin 5 Amp combined flush type universal all as specified and as directed .
S & F in repair switch socket combination 5 in 1 pin 5 / 16A, flush type all as specified and as directed.
S & F in repairs ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S&F in repair ding dong bell, AC, 230 volts, single phase, 50 HZ complete all as specified and as directed
S & F in repair bell push 5 Amp flush type complete all as specified and as directed .
S &F in repair lamp holder, insulated body ,with back plate for batten fitting complete all as specified and as directed.
M & L for sub main wiring complete with 1100volt grade PVC insulated unsheathed multi stranded cable with 1100volt grade PVC insulated unsheathed multi stranded 02 run of 04sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC CONDUIT in Ivory/Grey/white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 4 sq mm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 03 runs of 04 sq mm and 01 run of PVC conduit will be measured as one unit length.
M & L for sub main wiring complete with 1100volt grade PVC insulated unsheathed multi stranded cable with 1100volt grade PVC insulated unsheathed multi stranded 02 run of 06 sq mm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC CONDUIT in Ivory/Grey/white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 6.0 sq mm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 03 runs of 06 sq mm and 01 run of PVC conduit will be measured as one unit length.
S&F MCB DB SPN double door 8 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-43 degree protection complete all as specified and as directed.
S&F MCB DB TPN double door 4 way 415 volts 50 Hz horizontal with IP-43 degree protection complete all as specified and as directed
S&F in repair MCB TPN 'C' series 63 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and as directed
S&F in repair MCB 'C' series SP 06 to 32 Amp, 230 volts,50Hz,Breaking Capacity 10 KA complete all as specified and as directed
S& F in repairs 'C' series 20 to 32 Amp SPN MCB complete all as specified and as directed
M&L in repair for RCCB , DP, 25 Amp, 30 mA, 230 volts, 50 HZ, 10 KA breaking capacity complete all as specified and as directed .
S&F in repairs MCCB 4 Pole, current rating 100 Amp, Adjustable thermal setting breaking capacity 25 kA at 415V, 50Hz all as specified and as directed.
S &F in repair deluxe fan regulator electronic stepped type 230 volts 50 Hz complete all as specified and as directed
S&F in repair hylum sheet top cover 3 mm thick for fixing switches, sockets, fan regulators etc including cutting into suitable sizes all as specified and as directed .
S & F in repair LED INTEGRATED BATTEN T5 tube light fitting type 1x 10 watt indoor decorative aluminium extruded T5 LED Battens-integrated type complete with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
S & F in repair LED spot light fitting complete recess mounting type 12 Watt with all accessories internally prewilized including connecting up with twin core twisted flexible copper cable and complete all as specified and as directed . Make: Luker , Model No.LCOB12 or equivalent in Philips / Crompton / Bajaj Notes for Item Nos 25 to 27:- (i)The contractor shall submit original manufacturer's replacement warranty certificate stating defective light fittings shall be replaced without any extra cost for minimum two years after completion of the work. (ii) The Contractor shall write CA No and date of completion on each LED light fittings. (iii) An amount of 10000/- shall be retained as security deposit against replacement warranty and this amount shall be released after successful completion of two years replacement warranty. Contractor cannot be claimed any interest for this amount.
Fixing only LED Tube light fitting 18/20 watt including connecting up with twin core twisted flexible copper cable and all as specified and as directed . Note. LED Tube light fitting shall issued under schedule ' B '.
M & L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 m deep below the ground level with top to edge of the plate n. less than 1.5 m below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified and as directed.
S & F in repairs emergency Power system consisting of invertor equipment 2 KVA, Single Phase 230V including two numbers 150 A Hr tubular battery with protections for overload deep discharge, short circuit and reverse polarity and display for mains available battery Charging, Battery Charging level inverter switched ON low battery Indication overload indication etc all as specified and as directed.
sapna enterprises
DOGRA ELECTRICALS
Mehta and Co.
NATIONAL ENGINEERING CORPORATION
Super Construction
pk janardhanan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .