Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.5 LAdmitted-Finance | -15.99% | ₹4.5 L | L1 | Admitted-Finance |
| 2 | L2₹4.7 LAdmitted-Finance H NO 29 FIRST FLOOR MASJIT MOTH SOUTH EXTENSION PART II DELHI 110049 | DELHI | SOUTH DELHI | DELHI | 110049 | -11.10% | ₹4.7 L | L2 | Admitted-Finance |
| 3 | L3₹5.1 LAdmitted-Finance | -5.10% | ₹5.1 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical not eligible |
Tender Value
₹5.3 L
EMD Value
₹10,683
Closing Date
24 Mar 2026, 1:00 pmClosed
Executive Engineer
12, Cavalry Lane, Engineering Department, University of Delhi, Delhi-110007
Electrical Maintenance work to be carried out in various rooms at Department of Anthropology, University of Delhi
2026_DU_902021_1
CEET-7376
Open Tender
Electrical Works
10 days
North Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar, University of Delhi
₹10,683
9 Apr 2026
11 Mar 2026
25 Mar 2026
11 Mar 2026
24 Mar 2026
11 Mar 2026
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
8 Module (125mmX125mm)
6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5 amps switch
5 amps socket
15 amps switch
15 amps socket
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing of 3 Module GI box with modular plate having 1 nos of 15/16 amp socket and 1 nos of 15/16 amp switch i/c making connection etc as reqd
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V 50 HZ , Single phase AC supply , earthing etc complete as reqd
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 10 sq. mm (25mm)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
Supply, Installation, testing and commissioning of one no. LED tube of , 16.5 Watt complete as required. Tube equivalent to Philips Make, Cat No. MAS LEDTube 1200mm HE 16.5W 865 T5.
Replacement of condenser of 2.5/3.15 mfd for ceiling fan including making necessary connections etc. complete as required
Supply and fixing of street light pole box of size (250 X 200 X 100) complete with all necessary accessories including suitable clamps, bakelite sheet, brass screws, washers, and 01 no. 10 Amps SP MCB (Single Pole Miniature Circuit Breaker), inclusive of making electrical connections, as required at site.
Supply, Installation, testing and commissioning of pre-wired, 150 watt, flood light Pressure die-cast aluminium housing with high impact resistance (IK07) glass cover IP66 protection, 130lm/w, 220-240 V, 50 Hz on existig street light pole/wall including all accessories and connection etc.as required..Philips Make, Cat No. BVP 192 LED 177 CW NB FG A1 PSU GR or equivalent model of Thorn/Trilux
Supplying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of size 4C X 10 sqmm etc as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_948113.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_948113.xls
BOQ • 3.46 MB
Download all tender documents and submit your bid