| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 1105 NEW DELHI HOUSE NEW DELHI HOUSE 1105 NEW DELHI HOUSE 27 BARAKHAMBA ROAD 091 CENTRAL DELHI DELHI 110001 | NEW DELHI | DELHI | 110001 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 3 6 584 G HIMAYATNAGAR STREET NO 8 HYDERABAD HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 0 F 16A ROAD NO 3 MIA MADRI UDAIPUR RAJASTHAN 313003 | UDAIPUR | RAJASTHAN | 313003 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical A 25 MOHAN COOPERATIVE INDUSTRIAL ESTATE MATHURA ROAD SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹40 L
Closing Date
13 Jul 2026, 2:00 pmClosed
Shamik Gupta
BHEL Sadan Sector 16A, Noida-201301
Open tender Enquiry for LT Switchgear for 2 X 800 MW NTPC SINGRAULI TPP Stage-III Project
2026_BHEL_60787_1
77/26/6027/SHA
Open Tender
Electrical Work/ Equipment
Lump-sum
450 days
SONEBHADRA
As per NIT
2 documents required · 2 mandatory
₹0
₹40 L
Yes
PEM Noida office
2 Jun 2026
2 May 2026
13 Jul 2026
2 May 2026
13 Jul 2026
2 May 2026
2 May 2026 - 13 Jul 2026
22 May 2026
2X800 MW NTPC SINGRAULI STPP STAGE – III
NIT No. 77/26/6027/SHA, Dated 02.052026
S.No. ITEM NO. ITEM NAME UOM TOTAL QTY. RATING (A) BOARD NO. UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) NO. OF PCC / ACB PANEL NO. OF MCC / ACDB / DCDB PANEL BOARD NAME PLATE, DESCRIPTION & RATING
1 506-0110316-00-A UNIT EMERGENCY SWBD-1 NOS. 1 3000 8DG U#8 EMERGENCY MCC 8DG, 3000A
2 506-0110040-00-A 220V MAIN DCDB-1 NOS. 1 1600 8FA U#8 220V MAIN DCDB 8FA, 1600A
3 506-0110382-00-A Unit Boiler PMCC-1 NOS. 1 4000 8DA U#8 BOILER SERVICE PMCC 8DA, 4000A
4 506-0110107-00-A BOILER V&D ACDB-1 NOS. 1 250 8HA U#8 BOILER VALVE & DAMPER ACDB 8HA, 250A
5 506-0110092-00-A BOILER ACDB-1 NOS. 1 630 8HB U#8 BOILER ACDB 8HB, 630A
6 506-0110419-00-A SOOT BLOWER MCC-1 NOS. 1 63 U#8 SOOT BLOWER MCC, 63A
7 506-0110387-00-A Unit Turbine PMCC-1 NOS. 1 4000 8DB U#8 TURBINE SERVICE PMCC 8DB, 4000A
8 506-0110321-00-A UNIT SERVICE ACDB-1 NOS. 1 630 8QA U#8 UNIT SERVICE ACDB 8QA, 630A
9 506-0110300-00-A TURBINE VALVE ACDB-1 NOS. 1 250 8KA U#8 TURBINE VALVE DB 8KA, 250A
10 506-0110317-00-A UNIT EMERGENCY SWBD-2 NOS. 1 3000 9DG U#9 EMERGENCY MCC 9DG, 3000A
11 506-0110041-00-A 220V MAIN DCDB-2 NOS. 1 1600 9FA U#9 220V MAIN DCDB 9FA, 1600A
12 506-0110383-00-A Unit Boiler PMCC-2 NOS. 1 4000 9DA U#9 BOILER SERVICE PMCC 9DA, 4000A
13 506-0110108-00-A BOILER V&D ACDB-2 NOS. 1 250 9HA U#9 BOILER VALVE & DAMPER ACDB 9HA, 250A
14 506-0110093-00-A BOILER ACDB-2 NOS. 1 630 9HB U#9 BOILER ACDB 9HB, 630A
15 506-0110420-00-A SOOT BLOWER MCC-2 NOS. 1 63 U#9 SOOT BLOWER MCC, 63A
16 506-0110388-00-A Unit Turbine PMCC-2 NOS. 1 4000 9DB U#9 TURBINE SERVICE PMCC 9DB, 4000A
17 506-0110322-00-A UNIT SERVICE ACDB-2 NOS. 1 630 9QA U#9 UNIT SERVICE ACDB 9QA, 630A
18 506-0110301-00-A TURBINE VALVE ACDB-2 NOS. 1 250 9KA U#9 TURBINE VALVE DB 9KA, 250A
19 506-0110179-00-A ESP SWBD NOS. 12 3000 8DD, 8DE, 8DF, 8DC, 8DH, 8DJ, 9DD, 9DE, 9DF, 9DC, 9DH, 9DJ U#8 & U#9 ESP PMCC's, 3000A
20 506-0110180-00-A ESP SWBD-1 NOS. 1 4000 8DL U#8 ESP STANDBY PMCC 8DL, 4000A
21 506-0110181-00-A ESP SWBD-2 NOS. 1 4000 8DM U#8 ESP STANDBY PMCC 8DM, 4000A
22 506-0110182-00-A ESP SWBD-3 NOS. 1 4000 9DL U#9 ESP STANDBY PMCC 9DL, 4000A
23 506-0110183-00-A ESP SWBD-4 NOS. 1 4000 9DM U#9 ESP STANDBY PMCC 9DM, 4000A
24 506-0110170-00-A ESP A/C & VENT MCC-1 NOS. 1 630 8TB U#8 ESP HVAC MCC 8TB, 630A
25 506-0110165-00-A ESP & ID FAN AREA MCC-1 NOS. 1 400 8HD U#8 ESP & ID FAN AREA MCC 8HD, 400A
26 506-0110171-00-A ESP A/C & VENT MCC-2 NOS. 1 400 9TB U#9 ESP HVAC MCC 9TB, 400A
27 506-0110166-00-A ESP & ID FAN AREA MCC-2 NOS. 1 400 9HD U#9 ESP & ID FAN AREA MCC 9HD, 400A
28 506-0110264-00-A STATION SERVICE SWBD.-1 NOS. 1 4000 0DA U#8 STATION SERVICE PMCC 0DA, 4000A
29 506-0110077-00-A AIR CONDITIONING MCC NOS. 1 1250 0TA U#8 & 9 AIR CONDITIONING MCC 0TA, 1250A
30 506-0110331-00-A VENTILATION MCC-1 NOS. 1 1000 8TA U#8 VENTILATION MCC 8TA, 1000A
31 506-0110241-00-A MISC. SERVICE MCC-1 NOS. 1 630 0QA U#8 MISC. SERVICES MCC 0QA, 630A
32 506-0110079-00-A AIR WASHER MCC-1 NOS. 1 800 0SA U#8 AIR WASHER MCC 0SA, 800A
33 506-0110983-00-A OUTDOOR SWGR # 1 NOS. 1 400 U#8 TRF AREA OUTDOOR SWGR, 400A
34 506-0110265-00-A STATION SERVICE SWBD.-2 NOS. 1 4000 0DB U#9 STATION SERVICE PMCC 0DB, 4000A
35 506-0110332-00-A VENTILATION MCC-2 NOS. 1 1000 9TA U#9 VENTILATION MCC 9TA, 1000A
36 506-0110242-00-A MISC. SERVICE MCC-2 NOS. 1 630 0QB U#9 MISC. SERVICES MCC 0QB, 630A
37 506-0110080-00-A AIR WASHER MCC-2 NOS. 1 800 0SB U#9 AIR WASHER MCC 0SB, 800A
38 506-0110984-00-A OUTDOOR SWGR # 2 NOS. 1 400 U#9 TRF AREA OUTDOOR SWGR, 400A
39 506-0110162-00-A DM PLANT SWBD. NOS. 1 4000 0DE DM/ CPU/ SERVICE PMCC 0DE, 4000A
40 506-0110142-00-A CPU MCC NOS. 1 630 0WA CPU MCC 0WA, 630A
41 506-0110259-00-A SERVICE BLDG. MCC NOS. 1 1000 0WB SERVICE BUILDING MCC 0WB, 1000A
42 506-0110339-00-A WORKSHOP SWBD NOS. 1 2500 0DF WORKSHOP/ ETP ACDB 0DF, 2500A
43 506-0110184-00-A ETP MCC NOS. 1 400 0DI ETP MCC 0DI, 400A
44 506-0110254-00-A RAW WATER SWBD. NOS. 1 3000 0DM RWPH/ AUX CT/ O&M STORE PMCC 0DM, 3000A
45 506-0111020-00-A AUX CT SWBD NOS. 1 400 0DK AUX CT MCC 0DK, 400A
46 506-0111019-00-A O&M STORE SWBD NOS. 1 400 0WE O&M STORE ACDB 0WE, 400A
47 506-0111032-00-A CLARIFIER WATER P/H SWBD NOS. 1 2500 0DD SW/ CLW/ PTP PMCC 0DD, 2500A
48 506-0110251-00-A PRE-TREATMENT PLANT MCC NOS. 1 1000 0WC PTP MCC 0WC, 1000A
49 506-0110044-00-A 220V OFFSITE DCDB NOS. 1 125 0FA 220V AUX CT & RW PH DCDB 0FA, 125A
50 506-0111033-00-A CHLORINATION PLANT SWBD NOS. 1 1000 0DC FIRE WATER/CW/CLO2/CWTP PMCC 0DC, 1000A
51 506-0111035-00-A CSSP SWBD NOS. 1 2500 0DH CSSP PMCC 0DH, 2500A
52 506-0110190-00-A FUEL OIL P/H SWBD. NOS. 1 2500 0DN FOPH PMCC 0DN, 2500A
53 506-0111024-00-A CHP SWBD-1 NOS. 1 4000 0DR CHP PMCC-01 0DR, 4000A
54 506-0111025-00-A CHP SWBD-2 NOS. 1 4000 0DS CHP PMCC-02 0DS, 4000A
55 506-0111026-00-A CHP SWBD-3 NOS. 1 4000 0DU CHP PMCC-03 0DU, 4000A
56 506-0111021-00-A 220V CHP DCDB-1 NOS. 1 150 0FC 220V CHP MCC-2 DCDB 0FC, 150A
57 506-0111022-00-A 220V CHP DCDB-2 NOS. 1 125 0FC1 220V CHP MCC-3 DCDB 0FC1, 125A
58 506-0111034-00-A SWITCHYARD SERVICE SWBD NOS. 1 1000 0DJ SWYD ACDB 0DJ, 1000A
59 506-0110977-00-A 220V SWITCHYARD DCDB 1 NOS. 1 125 0FD 220V SWYD DCDB 0FD, 125A
60 506-0110404-00-A 48V SWITCHYARD DCDB NOS. 1 125 48V SWYD DCDB, 125A
61 506-0110411-00-A SWITCHYARD EMERGENCY DB NOS. 1 250 SWITCHYARD EMERGENCY POWER DB, 250A
62 506-0111030-00-A SWITCHYARD AC SWBD NOS. 1 250 SWITCHYARD AC MCC, 250A
63 506-0111031-00-A SWITCHYARD VENTILATION SWBD NOS. 1 250 SWITCHYARD VENTILATION MCC, 250A
64 506-0110412-00-A SWITCHYARD OIL FILTRATION SWBD NOS. 1 400 SWITCHYARD OIL FILTRATION BOARD, 400A
65 506-0110985-00-A AC MCCB BOX NOS. 125 63
66 506-0110986-00-A DC MCCB BOX NOS. 25 63
67 506-0110417-00-A HMI SYSTEM NOS. 1 AS PER ANNEXURE-A
68 506-0111006-00-A NUMERICAL RELAY, IMCC AND WIRELESS TEMP MONITORING SYSTEM- NETWORKING HARDWARE LOTS 1 AS PER ANNEXURE-B1 & B3
69 506-0110991-00-A AMC FOR NUMERICAL RELAY LOTS 1 NA 0 AS PER ANNEXURE-B2
70 506-0111007-00-C NUMERICAL RELAY, IMCC AND WIRELESS TEMP MONITORING SYSTEM & HMI SYSTEM- COMMISSIONING SET 1 NA 0 AS PER ANNEXURE-C_NUMERICAL RELAY, IMCC, WIRELESS TEMP MONITORING & HMI SYSTEM- COMMISSIONING
71 506-0110282-00-A TOOLS & TACKLE SET 1 AS PER ANNEXURE-D
72 506-0110991-00-A SITE MODIFICATION LOTS 1 NA 0 AS PER ANNEXURE-E
73 506-0110989-00-A E & C SPARES LOTS 1 AS PER ANNEXURE-F
74 506-0110000-00-B MANDATORY SPARES SET 1 AS PER ANNEXURE-G
75 GRAND TOTAL (Evaluation Price shall be Exworks + Freight)
1 TO CALCULATE THE SWITCHBOARD PRICES, REFER DETAILED BOARD WISE BOM AND MODULE WISE BOM, ANNEXURE-A.1 AND ANNEXURE-A.2 OF TECHNICAL DATA PART-A OF TECHNICAL SPECIFICATION (PE-TS-512-506-E002) RESPECTIVELY.
2 BIDDER HAS TO QUOTE FOR THE FOLLOWING ALONG WITH THE BID:
i) HMI SYSTEM: AS PER LIST IN ANNEXURE–A
ii) NETWORKING HARDWARE FOR NUMERICAL RELAYS, IMC AS PER LIST IN ANNEXURE-B1 & FOR WIRELESS TEMPERATURE MONITORING SYSTEM AS PER LIST IN ANNEXURE-B3
iii) AMC FOR NUMERICAL RELAYS AS PER ANNEXURE-B2
iv) NUMERICAL RELAY, IMCC, WIRELESS TEMPERATURE MONITORING & HMI SYSTEM COMMISSIONING: AS PER ANNEXURE-C
v) TOOLS & TACKLES: AS PER ANNEXURE-D
vi) SITE MODIFICATION CHARGES: AS PER ANNEXURE-E
vii) E & C SPARES: AS PER ANNEXURE-F
viii) MANDATORY SPARE: AS PER LIST IN ANNEXURE–G
ix) BIDDER TO PROVIDE A SCHEDULE OF UNIT PRICES IN ACCORDANCE WITH THE LIST PROVIDED IN ANNEXURE-H
3 BIDDER TO ENSURE THAT SUMMATION OF PRICES (AS PER ANNEXURE-H) OF APPLICABLE MODULES (AS PER ANNEXURE A.1-BOARDWISE BOM) AND APPLICABLE PANELS (MENTIONED ABOVE BY THE BIDDER) OF A BOARD SHALL BE EQUIVALENT TO BOARD PRICE QUOTED ABOVE FOR THAT BOARD. VARIATION OF +/- 5% IS ACCEPTABLE IN THE DERIVED PRICE FROM THE BOARD PRICE QUOTED ABOVE.
4 ADDITION/ DELETION OF QUANTITIES SHALL BE APPLICALBE AT THE QUOTED PRICES. ALLOWABLE VARIATION IN QUANTITY AND PRICE SHALL BE AS PER NIT.
5 ALL LT PCC/ PMCC/MCC/ DBs SHALL BE SUPPLIED ALONGWITH THE INTEGRAL BASE FRAMES, FOUNDATION BOLTS, CABLE GLANDS & LUGS. PRICES FOR THE SAME SHALL BE BUILT IN THE SWITCHBOARD PRICE.
6 BIDDER IS REQUIRED TO PROVIDE THE QUANTITY OF PANELS CORRESPONDING TO EACH BOARD IN THE TABLE ABOVE WHEN SUBMITTING THEIR TECHNO-COMMERCIAL PROPOSAL.
7 IN CASE MODULE DOORS ARE PART OF MODULES, 2 NOS OF DUMMY MODULES OF EACH SIZE TO FILL IN MODULE BEING TAKEN OUT FOR MAINTENANCE PURPOSE SHALL BE PROVIDED IN EACH SWITCHGEAR ROOM (REFER ANNEXURE-3_TENTATIVE SWITCHGEAR LOCATION OF TECHNICAL SPECIFICATION PE-TS-512-506-E002), THESE DUMMY MODULES SHALL BE FITTED IN SWITCHBOARD AS VACANT MODULES HAVING NO CUT OUT ON BACK SIDE AND CABLE ALLEY SIDE. IN CASE DOOR IS HINGED TO THE PANEL, 2 NOS OF BLANKING PLATES OF EACH SIZE NEED TO BE PROVIDED. PRICES FOR THE SAME SHALL BE BUILT IN THE SWITCHBOARD PRICE.
8 NO ADDITIONAL PRICES SHALL BE PAID FOR PROTOTYPE PANELS, PRICES QUOTED ABOVE INCLUDES COST OF PROTOTYPE PANELS ALSO.
9 PVC SHALL BE APPLICABLE FOR THIS ENQUIRY FOR PMCC / PCC / MCC / ACBD / DCDB ONLY) AS PER IEEMA CIRCULAR (https://ieema.org/wp-content/uploads/2020/07/lvswgr-jan-2019.pdf) .PRICE VARIATION IS NOT APPLICABLE FOR AC MCCB BOX; DC MCCB BOX; HMI SYSTEM; NUMERICAL RELAY, IMCC AND WIRELESS TEMP MONITORING SYSTEM- NETWORKING HARDWARE; AMC FOR NUMERICAL RELAY; NUMERICAL RELAY, IMCC, WIRELESS TEMP MONITORING AND HMI SYSTEM- COMMISSIONING; TOOLS & TACKLE; SITE MODIFICATION; E & C SPARES & MANDATORY SPARES.
10 IN UNIT ADDITION-DELETION PRICES (ANNEXURE-H), PRICES QUOTED FOR COMPONENTS SHALL BE REASONABLE AND AS PER LIST PRICE OF CONCERNED MANUFACTURERS.
S. No. Item Description QTY. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
COMPLETE DESIGN, ENGINEERING & SUPPLY OF THE FOLLOWING ITEMS :
1 HMI (EWS) 4 NOS.
2 CONSOLE FOR HMI 4 NOS. REFER NOTE- 2 & 3
3 LASER PRINTER (A4 SIZE) 4 NOS.
4 TABLE FOR PRINTER 4 NOS. REFER NOTE- 3
5 TOTAL OF ANNEXURE A
1 REFER ANNEXURE-1_TYPICAL SWITCHGEAR RELAY NETWORK ARCHITECTURE.
2 INDUSTRIAL MODULAR DESIGN CONSOLE (FURNITURE I.E. TABLE WITH DRAWER & SWIVEL COMPUTER CHAIR) SHALL BE PROVIDED. EACH CONSOLE SHALL HAVE SPACE FOR KEEPING AN ADDITIONAL PC.
3 MAKE AND COLOR SHADE OF FURNITURE SHALL BE DECIDED DURING DETAIL ENGINEERING. FURNITURE COLOR SHADE SHOULD MATCH WITH CONTROL ROOM FURNITURE.
4 BHEL WILL PROVIDE UPS REDUNDANT FEEDER AT ONE LOCATION NEAR TO EWS LOCATION. FURTHER DISTRIBUTION OF UPS SUPPLY (FOR HMI, NETWORK SWITCH ETC.) ALONG WITH UPS DB SHALL BE IN THE SCOPE OF BIDDER.
5 FOR TESTING AND ERECTION & COMMISSIONING CHARGES FOR HMI- ITEMS, KINDLY REFER S.No.4 OF ANNEXURE-C.
NETWORKING HARDWARE FOR NUMERICAL RELAY & IMCC
S. No. Item Description QTY. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
1 ETHERNET SWITCH WITH IEC-61850 PROTOCOL IT SHALL BE PART OF SWITCHBOARD
2 NETWORK LEVEL ETHERNET SWITCH (OF ADEQUATE PORTS) 2 SET NEAR DDCMIS END, INCLUDING COMPLETE DESIGN, ENGINEERING, SUPPLY, TESTING AND ERECTION & COMMISSIONING. EACH SET SHALL BE SUITABLE FOR RECEIVING SIGNALS FROM EACH SWITCHGEAR LEVEL NETWORK/RING OF ETHERNET SWITCH's. BOTH SET OF NETWORK LEVEL ETHERNET SWITCH SHALL BE MOUNTED IN ETHERNET SWITCH BOX.
3 CAT5e/CAT6 or Better Ethernet CABLE 5000 METERS
4 SIMPLEX FIBER OPTICAL CABLE FOR COMMUNICATION BETWEEN SWGR LEVEL ETHERNET SWITCH's (& THEIR RINGS) & NETWORK LEVEL ETHERNET SWITCH 40000 METERS
5 HDPE CONDUIT (RODENT FREE) 40000 METERS USED FOR FIBER OPTICAL CABLE AT S.NO. 4
6 FO TERMINATION ACCESSORIES AT BIDDER'S SUPPLIED EQUIPMENT END UNDER THIS PACKAGE 1 SET ANNEXURE-1_TYPICAL SWITCHGEAR RELAY NETWORK ARCHITECTURE FOR SCOPE AND TERMINAL POINT
7 LAPTOP PC WITH LICENCED VERSION SOFTWARE, HARDWARE FOR RELAY, IMC PARAMETERISATION 5 NOS.
8 INTERFACE CABLE WITH SUITABLE CONNECTING PORT AT BOTH END FOR CONNECTION OF NUMERICAL RELAY FRONT PORT TO THE LAPTOP 55 NOS. EACH CABLE OF LENGTH ATLEAST 5M
9 INTERFACE CABLE WITH SUITABLE CONNECTING PORT AT BOTH END FOR CONNECTION OF IMCC FRONT PORT TO THE LAPTOP 20 NOS. EACH CABLE OF LENGTH ATLEAST 5M
10 Total of Annexure B1
1 REFER ANNEXURE- 3_TENTATIVE SWITCHBOARD LOCATION DETAIL FOR DISTANCE BETWEEN SWITCHGEAR AND NETWORK LEVEL ETHERNET SWITCH IN MAIN CONTROL ROOM.
2 REFER ANNEXURE- 1_TYPICAL SWITCHGEAR RELAY NETWORK ARCHITECTURE FOR HMI REQUIREMENT.
3 BIDDER TO PROVIDE ONE NO. OF EACH TYPE OF IMCC MODULE ALONG WITH Y-LINK TO BHEL ON RETURNABLE BASIS & COORDINATE WITH BHEL FOR CONDUCTING FAT FOR IMCC AS PER CUSTOMER SATISFACTION.
AMC FOR NUMERICAL RELAY
S. No. Item Description QTY. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. GST@18% ON EX-WORKS (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
1 AMC for 3 years for following : - Numerical Relays (with IEC 61850) in all LV Switchgears - IEC 61850 Ethernet switches in Switchgear panels - Cat5e Ethernet cable / FO cable/ Optical Fibre Cable with fire retardant outer sheath - Optical fibre cable termination equipment such as LIU, patch cord etc. for complete network - Laptops - HMI stations (Engineering Work Stations and printers) - All other equipment required to meet the intended specification AMC START DATE: REFER NOTE-1
1.1 1st year 1 Lot
1.2 2nd year 1 Lot
1.3 3rd year 1 Lot
0.0 TOTAL OF ANNEXURE B2
1 THE COMMENCEMENT DATE FOR AMC WILL BE FROM THE DATE OF TAKEOVER BY THE END CUSTOMER. HOWEVER, TENTATIVE DATE OF AMC COMMENCEMENT SHALL BE 05.05.2028.
NETWORKING HARDWARE FOR WIRELESS TEMPERATURE MONITORING SENSOR
S. No. Item Description Qty. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
1.A COMPLETE NETWORKING HARDWARE(EXCEPT CABLE & TERMINATION ACCESSORIES) NEAR SWITCHGEAR END FOR COMMUNICATION BETWEEN WIRELESS TEMPERATURE RECEIVER END & DDCMIS/HMI FOR TEMPERATURE MONITORING SYSTEM :- FOR TWO SET OF SWITCHBOARDS- a. FIRST SET- 8DA, 8DB & 8DG b. SECOND SET- 9DA, 9DB & 9DG 2 SET INCLUDING COMPLETE DESIGN, ENGINEERING AND SUPPLY. 1 SET IS FOR EACH UNIT (CONSISTS OF 3 SWITCHBOARDS)
1.B SPECIAL CABLE(TWISTED PAIR/CAT/OPTICAL FIBRE CABLE OR AS APPLICABLE) INCLUDING TERMINATION ACCESSORIES FOR COMMUNICATION BETWEEN SWITCHGEAR & DDCMIS/HMI FOR TEMPERATURE MONITORING SYSTEM :- FOR TWO SET OF SWITCHBOARDS- a. FIRST SET- 8DA, 8DB & 8DG b. SECOND SET- 9DA, 9DB & 9DG 2 SET INCLUDING COMPLETE DESIGN, ENGINEERING AND SUPPLY. 1 SET IS FOR EACH UNIT (CONSISTS OF 3 SWITCHBOARDS)
2.A COMPLETE NETWORKING HARDWARE(EXCEPT CABLE & TERMINATION ACCESSORIES) NEAR SWITCHGEAR END FOR COMMUNICATION BETWEEN WIRELESS TEMPERATURE RECEIVER END & DDCMIS/HMI FOR TEMPERATURE MONITORING SYSTEM :- FOR TWO SET OF SWITCHBOARDS- a. FIRST SET- 0DA b. SECOND SET- 0DB 2 SET INCLUDING COMPLETE DESIGN, ENGINEERING AND SUPPLY. 1 SET IS FOR EACH UNIT (CONSISTS OF 1 SWITCHBOARD)
2.B SPECIAL CABLE(TWISTED PAIR/CAT/OPTICAL FIBRE CABLE OR AS APPLICABLE) INCLUDING TERMINATION ACCESSORIES FOR COMMUNICATION BETWEEN SWITCHGEAR & DDCMIS/HMI FOR TEMPERATURE MONITORING SYSTEM :- FOR TWO SET OF SWITCHBOARDS- a. FIRST SET- 0DA b. SECOND SET- 0DB 2 SET INCLUDING COMPLETE DESIGN, ENGINEERING AND SUPPLY. 1 SET IS FOR EACH UNIT (CONSISTS OF 1 SWITCHBOARD)
TOTAL OF ANNEXURE B3
1 REFER ANNEXURE- 3_TENTATIVE SWITCHBOARD LOACTION DETAIL FOR DISTANCE BETWEEN SWITCHGEAR AND MAIN CONTROL ROOM.
2 FOR ABOVE ITEMS LISTED AT S.NO.1.A AND 1.B, BMCC(8DA), TMCC (8DB) and EMCC(8DG) OF ONE UNIT IS CONSIDERED AS 1 SET
NUMERICAL RELAY, IMCC, WIRELESS TEMPERATURE MONITORING & HMI SYSTEMS - COMMISSIONING CHARGES
S. No. Item Description Qty. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. GST@18% ON EX-WORKS (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
1 LUMP SUM ALL INCLUSIVE CHARGES PER NUMERICAL RELAY COMMISSIONING (INCLUDING CONVEYANCE TO SITE, BOARDING AND LODGING) 410 NOS.
2 LUMP SUM ALL INCLUSIVE CHARGES PER IMC COMMISSIONING (INCLUDING CONVEYANCE TO SITE, BOARDING AND LODGING) 3000 NOS.
3.A LUMP SUM ALL INCLUSIVE CHARGES FOR WIRELESS TEMPERATURE MONITORING SYSTEM COMMISSIONING. FOR TWO LOT OF SWITCHBOARDS- a. FIRST LOT- 8DA, 8DB & 8DG SWITCHBOARDS b. SECOND LOT- 9DA, 9DB & 9DG SWITCHBOARDS 2 LOT 1 LOT IS FOR EACH UNIT (CONSISTS OF 3 SWITCHBOARD). REFER NOTE NO.3A & 4A
3.B LUMP SUM ALL INCLUSIVE CHARGES FOR WIRELESS TEMPERATURE MONITORING SYSTEM COMMISSIONING. FOR TWO LOT OF SWITCHBOARDS- a. FIRST LOT- 0DA SWITCHBOARD b. SECOND LOT- 0DB SWITCHBOARD 2 LOT 1 LOT IS FOR EACH UNIT (CONSISTS OF 1 SWITCHBOARD). REFER NOTE NO.3B & 4B
4 TESTING AND ERECTION & COMMISSIONING CHARGES FOR HMI- ITEMS AT SL. NO. 1-4 OF ANNEXURE-A 4 NOS. 1 NO. SHALL CONSIST OF TESTING AND ERECTION & COMMISSIONING OF ONE ITEM EACH OF SL.NO. 1-4 OF ANNEXURE-A
5 TOTAL OF ANNEXURE C
1 AMOUNT PAYABLE FOR NUMERICAL RELAY COMMISSIONING = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.1 ABOVE x NO. OF RELAYS COMMISSIONED (SAME TO BE CERTIFIED BY BHEL).
2 AMOUNT PAYABLE FOR IMCC COMMISSIONING = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.2 ABOVE x NO. OF IMCC COMMISSIONED (SAME TO BE CERTIFIED BY BHEL).
3.A AMOUNT PAYABLE FOR WIRELESS TEMPERATURE MONITORING SYSTEM COMMISSIONING FOR EACH UNIT (BMCC, TMCC and EMCC) = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.3.A ABOVE (SAME TO BE CERTIFIED BY BHEL).
3.B AMOUNT PAYABLE FOR WIRELESS TEMPERATURE MONITORING SYSTEM COMMISSIONING FOR EACH UNIT (STATION SERVICE SWITCHBOARD) = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.3.B ABOVE (SAME TO BE CERTIFIED BY BHEL).
4.A FOR LINE ITEM 3.A, TESTING AND COMMISSIONING OF WIRELESS TEMPERATURE MONITORING SYSTEM FOR BMCC(8DA), TMCC (8DB) and EMCC(8DG) OF ONE UNIT IS CONSIDERED AS 1 LOT, SIMILARLY 3 BOARDS OF ANOTHER UNIT FOR 2ND LOT.
4.B FOR LINE ITEM 3.B, TESTING AND COMMISSIONING OF WIRELESS TEMPERATURE MONITORING SYSTEM FOR STATION SERVICE SWITCHBOARD (0DA) OF ONE UNIT IS CONSIDERED AS 1 LOT, SIMILARLY 1 BOARD OF ANOTHER UNIT FOR 2ND LOT.
5 APPROXIMATELY 15 NOs. OF NUMERICAL RELAYS AND/OR 50 NOs. OF IMCS CAN BE CONSIDERED BY BIDDER FOR COMMISSIONING IN EACH VISIT.
6 FOR LINE ITEM 1, 2, 3.A & 3.B, BIDDER TO NOTE THAT TESTING, CONFIGURATION AND NETWORKING SETUP OF RELAY, IMC & TEMPERATURE MONITORING SYSTEM SHALL BE THE BIDDER’S RESPONSIBILITY COMPLETELY.
7 FOR LINE ITEM 4, BIDDER TO NOTE THAT ERECTION & COMMISSIONING, TESTING, CONFIGURATION AND NETWORKING SETUP OF HMI SYSTEM SHALL BE THE BIDDER’S RESPONSIBILITY COMPLETELY.
8 BIDDER TO COORDINATE WITH DCS SUPPPLIER (BHEL EDN) TO ENSURE SMOOTH AND EFFECTIVE COMMUNICATION BETWEEN NUMERICAL RELAY/ Y-LINK AND DCS, AS WELL AS BETWEEN TEMPERATURE MONITORING SYSTEM AND DCS/HMI.
9 FOR LINE ITEMS 1 TO 4, BIDDER TO DEPUTE ITS MANPOWER WITHIN 15 DAYS FROM THE DATE OF INTIMATION BY BHEL.
TOOLS & TACKLES
S. No. Item Description Quantity Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
1 ACB RACKING HANDLE 30 Nos.
2 TELESCOPIC TROLLY (TROLLEY FOR ACB HANDLING) 20 Nos.
3 DOOR KEY 100 Nos.
4 RELAY TEST EQUIPMENT 2 Nos.
5 MODULE RACKING HANDLE 30 Nos.
16 TOTAL OF ANENXURE -D
1 BIDDER HAS TO QUOTE FOR TOOLS AND TACKLES MENTIONED ABOVE. HOWEVER, BIDDER HAS TO INDICATE ANY SPECIAL TOOLS (IF REQUIRED).
SITE MODIFICATION CHARGES
S. No. Item Description Quantity Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. GST@18% ON EX-WORKS (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.)
1 LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR SKILLED TECHNICIAN (EXCEPT DAILY CHARGES) 15 VISITS
2 LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SKILLED TECHNICIAN 60 DAYS
3 LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR SERVICE ENGINEER (EXCEPT DAILY CHARGES) 15 VISITS
4 LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SERVICE ENGINEER 60 DAYS
6 TOTAL OF ANNEXURE E
1 AMOUNT PAYABLE FOR SKILLED TECHNICIAN PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. 1 ABOVE + (DAILY CHARGES AS PER SL. NO. 2 ABOVE X NO. OF DAYS AT SITE) (TO BE CERTIFIED BY BHEL SITE)
2 AMOUNT PAYABLE FOR SERVICE ENGINEER PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. 3 ABOVE + (DAILY CHARGES AS PER SL. NO. 4 ABOVE X NO. OF DAYS AT SITE) (TO BE CERTIFIED BY BHEL SITE)
3 AMOUNT PAYABLE FOR SITE MODIFICATION MATERIAL SHALL BE BASED ON THE ACTUAL COST OF THE MATERIALS UTILIZED. (TO BE CERTIFIED BY BHEL SITE). THE COST OF THE ACTUAL MATERIALS USED WILL BE DETERMINED USING THE UNIT RATE PROVIDED BY THE BIDDER IN THE ANNEXURE-H.
4 FOR LINE ITEMS 1 TO 4, BIDDER TO DEPUTE ITS MANPOWER WITHIN 15 DAYS FROM THE DATE OF INTIMATION BY BHEL.
S. No. Item / Component Qty. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.)
1 FACTORY BUILT ASSEMBLIES (PCC/MCC/DB)
1.1 Busbar supports (Horizontal) 1 1 set of 3
1.2 Primary isolating contacts (Bus side) of each rating 1 1 set of 3
1.3 Primary isolating contacts (Load side) of each rating 1 1 set of 3
1.4 Secondary isolating contacts of each rating 1 1 set of 3
1.5 Gaskets (each size) 10 Meter
1.6 Fixed Terminal (1way) 20 Nos.
1.7 Shrouds (for outgoing modules) - one for each physical size of module 1 Nos.
1.8.a. Wire (for secondary wiring)-2.5 mm2 100 Metres
1.8.b. Wire (for secondary wiring)-1.5mm2 100 Metres
0.0 Lugs (for secondary wiring) 100 Nos.
2 AIR CIRCUIT BREAKER (FOR EACH RATING)
0.0 Shunt trip coil 5 Nos.
0.0 spring charging motor-1 motor of each rating 1 Nos.
0.9 closing coil 5 Nos.
0.9 Auxiliary switch 1 Nos.
3 ISOLATING SWITCH
3.1 Main contact kit for each rating 1 1 set of 3 poles
4 POWER CONTACTORS
4.1 Contactor coil of each rating 1 Nos.
4.2 Contacts kit (main) for each rating 1 1 set of 3 poles
5 AUXILIARY CONTACTORS
5.1 Complete unit with 2NO + 2NC contacts-1 no. of each rating/type 1 Nos.
5.2.a. Contactor coils-AC for each rating 1 Set
5.2.b. Contactor coils-DC for each rating 1 Set
6 MCCB-1 no. of each rating/type 1 Nos.
7 MPCB -1 no. of each rating/type 1 Nos.
8 MCB-1 no. of each rating/type 1 Nos.
6.1 Actuator contacts 5 Nos.
6.2 Element 5 Nos.
8 INDICATING LAMPS
8.1 Complete unit 10 Nos.
8.2 Lens (assorted) 10 Nos.
9.1 Selector & control switch (each type) 1 Nos.
9.2 Connecting cable between CT and IMCC of appropriate length 50 Nos.
9.3 Connecting cable between VT and IMCC of appropriate length 50 Nos.
9.4 IMC Display HMI cable of Appropriate length 50 Nos.
0.0 TOTAL OF ANNEXURE -F
MANDATORY SPARES
S.no. Item Description QTY. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. FREIGHT % IN W.R.T TOTAL EX- WORKS (IN %) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EXWORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.)
1 Complete breaker of each rating 10 Nos.
2 Numerical Relays of each type 5 Nos.
3 Auxiliary Relays of each type 10 Nos.
4 Horizontal busbar support Insulators 12 Nos.
5 Vertical busbar dropper support insulators 12 Nos.
6 Current transformer of each type & ratio 3 Nos.
7 Voltage transformer of each type & ratio 3 Nos.
8 Control supply transformer of each type & rating 3 Nos.
9 Power Contactor of each type and rating 10 Nos.
10 Coil for above contactor for each type and rating 10 Nos.
11 MCCBs (equally divided for all ratings) 40 Nos.
12 MPCBs (equally divided for all ratings) 40 Nos.
13 Closing coil of each type of each rating 10 Nos.
14 Trip coil of each type of each rating 10 Nos.
15 Aux contact set of each type and Rating 6 Sets.
16 Fixed contact set of each type & rating 3 Sets.
17 Moving contact set of each type & rating 3 Sets.
18 Maintenance tools and accessories for maintenance of LT MCC 2 Nos.
19 TOTAL OF ANNEXURE -G
MODULE UNIT PRICE
S.No. Item Description Quantity Unit Unit Price (Rs.) Remarks
1 INCOMING FEEDER UNIT
a) ACB Incomer to PCC/PMCC from Trafo. - Module Type DAET (I/C)
b) ACB Incomer to MCC - Module Type DAE (I/C)
c) ACB Incomer to Emergency Board - Module Type DG(I/C)
d) MCCB Incomer for MCC / ACDB – Module Type E3 (I/C)
63A – Fixed Type 1 No.
125A – Fixed Type 1 No.
160A – Fixed Type 1 No.
200A – Fixed Type 1 No.
250A – Fixed Type 1 No.
300A – Fixed Type 1 No.
400A – Fixed Type 1 No.
63A – Drawout Type 1 No.
125A – Drawout Type 1 No.
160A – Drawout Type 1 No.
200A – Drawout Type 1 No.
250A – Drawout Type 1 No.
300A – Drawout Type 1 No.
400A – Drawout Type 1 No.
e) MCCB Incomer with contactor changeover – Module Type CC
16A – Fixed Type 1 No.
32A – Fixed Type 1 No.
63A – Fixed Type 1 No.
125A – Fixed Type 1 No.
200A – Fixed Type 1 No.
250A – Fixed Type 1 No.
300A – Fixed Type 1 No.
400A – Fixed Type 1 No.
16A – Drawout Type 1 No.
32A – Drawout Type 1 No.
63A – Drawout Type 1 No.
125A – Drawout Type 1 No.
200A – Drawout Type 1 No.
250A – Drawout Type 1 No.
300A – Drawout Type 1 No.
400A – Drawout Type 1 No.
f) 220V DCDB Incomer from charger - Module type CH (I/C)
50A – CH Fixed Type 1 No.
100A – CH Fixed Type 1 No.
125A – CH Fixed Type 1 No.
150A – CH Fixed Type 1 No.
200A – CH Fixed Type 1 No.
300A – CH Fixed Type 1 No.
400A – CH Fixed Type 1 No.
450A – CH Fixed Type 1 No.
500A – CH Fixed Type 1 No.
630A – CH Fixed Type 1 No.
800A – CH Fixed Type 1 No.
1000A – CH Fixed Type 1 No.
1250A – CH Fixed Type 1 No.
1600A – CH Fixed Type 1 No.
50A – CH Drawout Type 1 No.
100A – CH Drawout Type 1 No.
125A – CH Drawout Type 1 No.
150A – CH Drawout Type 1 No.
200A – CH Drawout Type 1 No.
300A – CH Drawout Type 1 No.
400A – CH Drawout Type 1 No.
450A – CH Drawout Type 1 No.
500A – CH Drawout Type 1 No.
630A – CH Drawout Type 1 No.
800A – CH Drawout Type 1 No.
1000A – CH Drawout Type 1 No.
1250A – CH Drawout Type 1 No.
1600A – CH Drawout Type 1 No.
g) 220V DCDB Incomer from battery - Module type DB (I/C)
50A – DB Fixed Type 1 No.
100A – DB Fixed Type 1 No.
125A – DB Fixed Type 1 No.
150A – DB Fixed Type 1 No.
200A – DB Fixed Type 1 No.
300A – DB Fixed Type 1 No.
400A – DB Fixed Type 1 No.
450A – DB Fixed Type 1 No.
500A – DB Fixed Type 1 No.
630A – DB Fixed Type 1 No.
800A – DB Fixed Type 1 No.
1000A – DB Fixed Type 1 No.
1250A – DB Fixed Type 1 No.
1600A – DB Fixed Type 1 No.
50A – DB Drawout Type 1 No.
100A – DB Drawout Type 1 No.
125A – DB Drawout Type 1 No.
150A – DB Drawout Type 1 No.
200A – DB Drawout Type 1 No.
300A – DB Drawout Type 1 No.
400A – DB Drawout Type 1 No.
450A – DB Drawout Type 1 No.
500A – DB Drawout Type 1 No.
630A – DB Drawout Type 1 No.
800A – DB Drawout Type 1 No.
1000A – DB Drawout Type 1 No.
1250A – DB Drawout Type 1 No.
1600A – DB Drawout Type 1 No.
2 BUSCOUPLER UNIT
a) ACB Buscoupler to PCC/PMCC/MCC - Module Type DAET/ DAE (B/C)
b) MCCB Buscoupler for MCC / ACDB – Module Type E3 (B/C)
63A – Fixed Type 1 No.
125A – Fixed Type 1 No.
160A – Fixed Type 1 No.
200A – Fixed Type 1 No.
250A – Fixed Type 1 No.
300A – Fixed Type 1 No.
400A – Fixed Type 1 No.
63A – Drawout Type 1 No.
125A – Drawout Type 1 No.
160A – Drawout Type 1 No.
200A – Drawout Type 1 No.
250A – Drawout Type 1 No.
300A – Drawout Type 1 No.
400A – Drawout Type 1 No.
c) 220V DCDB buscoupler - Module Type - DC
50A – DC Fixed Type 1 No.
100A – DC Fixed Type 1 No.
125A – DC Fixed Type 1 No.
150A – DC Fixed Type 1 No.
200A – DC Fixed Type 1 No.
300A – DC Fixed Type 1 No.
400A – DC Fixed Type 1 No.
450A – DC Fixed Type 1 No.
500A – DC Fixed Type 1 No.
630A – DC Fixed Type 1 No.
800A – DC Fixed Type 1 No.
1000A – DC Fixed Type 1 No.
1250A – DC Fixed Type 1 No.
1600A – DC Fixed Type 1 No.
50A – DC Drawout Type 1 No.
100A – DC Drawout Type 1 No.
125A – DC Drawout Type 1 No.
150A – DC Drawout Type 1 No.
200A – DC Drawout Type 1 No.
300A – DC Drawout Type 1 No.
400A – DC Drawout Type 1 No.
450A – DC Drawout Type 1 No.
500A – DC Drawout Type 1 No.
630A – DC Drawout Type 1 No.
800A – DC Drawout Type 1 No.
1000A – DC Drawout Type 1 No.
1250A – DC Drawout Type 1 No.
1600A – DC Drawout Type 1 No.
d) 220V DCDB TIE - Module Type - HD
50A – HD Fixed Type 1 No.
100A – HD Fixed Type 1 No.
125A – HD Fixed Type 1 No.
150A – HD Fixed Type 1 No.
200A – HD Fixed Type 1 No.
300A – HD Fixed Type 1 No.
400A – HD Fixed Type 1 No.
450A – HD Fixed Type 1 No.
500A – HD Fixed Type 1 No.
630A – HD Fixed Type 1 No.
800A – HD Fixed Type 1 No.
1000A – HD Fixed Type 1 No.
1250A – HD Fixed Type 1 No.
1600A – HD Fixed Type 1 No.
50A – HD Drawout Type 1 No.
100A – HD Drawout Type 1 No.
125A – HD Drawout Type 1 No.
150A – HD Drawout Type 1 No.
200A – HD Drawout Type 1 No.
300A – HD Drawout Type 1 No.
400A – HD Drawout Type 1 No.
450A – HD Drawout Type 1 No.
500A – HD Drawout Type 1 No.
630A – HD Drawout Type 1 No.
800A – HD Drawout Type 1 No.
1000A – HD Drawout Type 1 No.
1250A – HD Drawout Type 1 No.
1600A – HD Drawout Type 1 No.
3 ACB outgoing supply feeder - Module Type DAE (O/G)/DAE-TIE
4 ACB outgoing motor feeder - Module Type DM/PM/AM (controlled from DDCMIS/PLC/ATRS)
5 MCCB outgoing supply feeders
a) Module Type E3(O/G)
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
160A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
300A - Fixed type 1 No.
400A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
160A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
300A - Drawout Type 1 No.
400A - Drawout Type 1 No.
b) Module Type E3-TP (O/G)
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
160A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
300A - Fixed type 1 No.
400A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
160A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
300A - Drawout Type 1 No.
400A - Drawout Type 1 No.
c) Module Type ES3 (O/G)
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
160A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
400A - Fixed type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
160A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
400A - Drawout Type 1 No.
d) 2-ph feeder Module Type E2(O/G)
100A - Fixed type 1 No.
160A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
300A - Fixed type 1 No.
400A - Fixed type 1 No.
100A - Drawout Type 1 No.
160A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
300A - Drawout Type 1 No.
400A - Drawout Type 1 No.
e) Double pole 1-ph feeder Module Type E1(O/G)
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
f) 3-Ph MCCB controlled outgoing contactor feeder with IMC Module Type EA3(O/G)
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
400A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
400A - Drawout Type 1 No.
g) 3-Ph MCCB controlled outgoing contactor feeder without IMC Module Type ET3(O/G)
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
400A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
400A - Drawout Type 1 No.
h) 1-Ph MCCB controlled outgoing contactor feeder Module Type EA1(O/G)
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
i) 220V DC Outgoing MCCB Type (X) Feeder
16A - Fixed type 1 No.
32A - Fixed type 1 No.
63A - Fixed type 1 No.
100A - Fixed type 1 No.
125A - Fixed type 1 No.
200A - Fixed type 1 No.
250A - Fixed type 1 No.
300A - Fixed type 1 No.
400A - Fixed type 1 No.
600A - Fixed type 1 No.
800A - Fixed type 1 No.
16A - Drawout Type 1 No.
32A - Drawout Type 1 No.
63A - Drawout Type 1 No.
100A - Drawout Type 1 No.
125A - Drawout Type 1 No.
200A - Drawout Type 1 No.
250A - Drawout Type 1 No.
300A - Drawout Type 1 No.
400A - Drawout Type 1 No.
600A - Drawout Type 1 No.
800A - Drawout Type 1 No.
6 DOL Motor Starter - Unidirectional Drive - Drawout Type
a) Module Type DK2 / PK2 / AK2 (controlled from DDCMIS/PLC/ATRS)
Upto 5.5KW 1 No.
b) Module Type DK21 / PK21 / AK21 (controlled from DDCMIS/PLC/ATRS)
c) Module Type DK2E/PK2E/AK2E (Reacceleration) (controlled from DDCMIS/PLC/ATRS)
Upto 5.5KW 1 No.
d) Module Type DK21E/PK21E/AK21E (Reacceleration) (controlled from DDCMIS/PLC/ATRS)
e) Module Type K2 (Controlled from LCP)
Upto 5.5KW 1 No.
f) Module Type K21 (Controlled from LCP)
g) Module Type K3 (Controlled from LPBS)
Upto 5.5KW 1 No.
h) Module Type K31 (Controlled from LPBS)
7 RDOL Motor Starter - Bidirectional Drive - Drawout Type
a) Module Type DN1/ PN1/ AN1 (controlled from DDCMIS/PLC/ATRS)
Upto 5.5KW 1 No.
8.1 Rapping Motor (RM1) Module with IMC 1 No.
8.2 Rapping Motor (RM2) Module with OLR 1 No.
9 DUST DENSITY MONITOR (DDM) Module 1 No.
10 HOPPER HEATER (HH) Module 1 No.
11 SUPPORT INSULATOR HEATER (HI) Module 1 No.
12 SHAFT INSULATOR HEATER (HS) Module 1 No.
13 Ash Level Indicator (ALI) Module 1 No.
14 ARECA MARSHALING (ARECA) Module 1 No.
15 WAVE LEVEL TRANSMITTER (WLT) Module 1 No.
16 MARSHALING MODULE FOR SSPB OF RAPPING MOTOR AND HOPPER HEATER FEEDBACK (MM) 1 No.
17 WALL BLOWER Module 1 No.
18 LR BLOWER Module 1 No.
19 AH BLOWER Module 1 No.
20 JAMMING RELAY Module 1 No.
21 Wireless Temperature Sensor (WTS1) Module (In one ACB/PCC panel with single ACB) 1 No.
22 Wireless Temperature Sensor (WTS2) Module (In one ACB panel with double ACB) 1 No.
23 Wireless Temperature Sensor (WTS3) Module (In one Double front MCC panel) 1 No.
24 Common Auxiliary Module
i Bus PT module for PCC/PMCC - G1 Type 1 No.
ii Bus PT module for Emergency MCC - G2 Type 1 No.
iii Bus PT module for MCC/ACDB - VM Type 1 No.
iv Bus PT DCDB - S Type 1 No.
b.1) 110V AC control supply module – Type CS (consisting of 415/110V control Trafo.)
b.2) 240 V AC control supply module – type CS (consisting of 415/240V control Trafo.)
b.3) 24V AC control supply module – Type CS (consisting of 415/24V control Trafo.)
c) 240V AC motor space heater module 1 No.
d) 220V DC supply module (for receiving 220V DC supply) 1 No.
e) 24V DC supply module 1 No.
f) 24 V winding heating module 1 No.
g) Alarm module 1 No.
h) Test supply module 1 No.
i) 240 V AC Panel Space heating supply module – type SH (consisting of 415/240V control Trafo.)
i) 240V AC SPACE HEATER SUPPLY MODULE- SHS 1 No.
j) Y-Link 1 No.
25 Empty Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar (4 Wire System)
a) PCC Panel (Single Front Drawout Type) Without Temperature Sensor
b) MCC Panel (Single Front Fixed Type )
c) MCC Panel (Single Front Drawout Type)
d) MCC Panel (Double Front Drawout Type)
e) ACDB Panel (Double Front Fixed Type)
f) 220V DCDB Panel (Single Front Fixed type) with 20kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1 No.
UPTO 630A (with 630A VBB) 1 No.
1000A (with 630A VBB) 1 No.
1600A (with 630A VBB) 1 No.
g) 220V DCDB Panel (Single Front Fixed type) with 40kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1 No.
UPTO 630A (with 630A VBB) 1 No.
1000A (with 630A VBB) 1 No.
1600A (with 630A VBB) 1 No.
h) 220V DCDB Panel (Double Front Fixed type) with 20kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1 No.
UPTO 630A (with 630A VBB) 1 No.
1000A (with 630A VBB) 1 No.
1250A (with 630A VBB) 1 No.
1600A (with 630A VBB) 1 No.
i) 220V DCDB Panel (Double Front Fixed type) with 40kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1 No.
UPTO 630A (with 630A VBB) 1 No.
1000A (with 630A VBB) 1 No.
1250A (with 630A VBB) 1 No.
1600A (with 630A VBB) 1 No.
j) 48V DCDB Panel (Single Front Fixed type)
UPTO 125A (with 125A VBB) 1 No.
UPTO 200A (with 200A VBB) 1 No.
UPTO 630A (with 630A VBB) 1 No.
k) 48V DCDB Panel (Double Front Fixed type)
UPTO 125A (with 125A VBB) 1 No.
UPTO 200A (with 200A VBB) 1 No.
UPTO 630A (with 630A VBB) 1 No.
l) Empty ACB Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar
26 Empty Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar (3 Wire System)
a) PCC Panel (Single Front Drawout Type) Without Temperature Sensor
b) MCC Panel (Double Front Drawout Type)
c) ACDB Panel (Double Front Fixed Type)
d) Empty ACB Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar
UPTO 630A 1 No.
28 Unit Prices For Circuit Components
a) Air Circuit Breaker without releases
630A ACB, 4P, EDO, AC 1 No.
800A ACB, 4P, EDO, AC 1 No.
1000A ACB, 4P, EDO, AC 1 No.
1250A ACB, 4P, EDO, AC 1 No.
1600A ACB, 4P, EDO, AC 1 No.
2000A ACB, 4P, EDO, AC 1 No.
2500A ACB, 4P, EDO, AC 1 No.
3000A ACB, 4P, EDO, AC 1 No.
4000A ACB, 4P, EDO, AC 1 No.
630A ACB, 3P, EDO, AC 1 No.
800A ACB, 3P, EDO, AC 1 No.
1000A ACB, 3P, EDO, AC 1 No.
1250A ACB, 3P, EDO, AC 1 No.
1600A ACB, 3P, EDO, AC 1 No.
2000A ACB, 3P, EDO, AC 1 No.
2500A ACB, 3P, EDO, AC 1 No.
3000A ACB, 3P, EDO, AC 1 No.
4000A ACB, 3P, EDO, AC 1 No.
800A ACB, 2P, MDO, DC 1 No.
1000A ACB, 2P, MDO, DC 1 No.
1250A ACB, 2P, MDO, DC 1 No.
1600A ACB, 2P, MDO, DC 1 No.
b) MPCB, Short-Circuit Release
c) TP MCCB, 2NO+2NC AUX, FSC & O/L RELEASE
d) TP MCCB, 2NO+2NC AUX, ADJ S/C & O/L RELEASE
e) TP MCCB with LSIG release
f) TP MCCB - Motorized with LSIG release
g) Power contactor (AC) ( With 2NO & 2NC Minimum)
h) Power contactor (DC) ( With 2NO & 2NC Minimum)
i) AC Aux. contactor With
2NO + 2NC 1 No.
3NO + 3NC 1 No.
4NO + 4NC 1 No.
6NO + 6NC 1 No.
j) DC Aux. contactor With
2NO + 2NC 1 No.
3NO + 3NC 1 No.
4NO + 4NC 1 No.
6NO + 6NC 1 No.
k) Protection Relay
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), STAND BY EARTH FAULT PROTECTION (51NS), RESTRICTED EARTH FAULT PROTECTION (64R), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1 No.
SEF NUMERICAL RELAY 1 No.
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), STAND BY EARTH FAULT PROTECTION (51NS), RESTRICTED EARTH FAULT PROTECTION (64R), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF), MEASUREMENT AND DISPLAY OF HARMONIC CONTECT OF VOLTAGE & CURRENT 1 No.
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1 No.
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), RESTRICTED EARTH FAULT PROTECTION (64R), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), DIFFERENTIAL PROTECTION (87) (HIGH IMPEDANCE), REVERSE POWER PROTECTION, DG NEUTRAL DISPLACEMENT (59), DG MONITORING, RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1 No.
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), STALLING/ LOCKED ROTOR PROTECTION (50L/R), THERMAL OVERLAOD PROTECTION (49), NEGATIVE PHASE SEQUENCE PROTECTION (46), BUS NO VOLT, REPETATIVE START PROTECTION (66), FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), MOTOR DIFFERENTIAL PROTECTION (87M), CIRCUIT BREAKER FAILURE (50BF), PHASE REVERSAL PROTECTION (46R), CURRENT UNBALANCE PROTECTION, RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1 No.
Numerical Check synchronising Relay 1 No.
Check synchronising Relay Type-SKE11 or better 1 No.
Guard Relay 1 No.
BATTERY EARTH FAULT RELAY, 1-7mA, NOMINAL VOLTAGE-220V DC, 1DV, 2NO S/R, FLUSH 1 No.
OVERLOAD RELAY, NOMINAL VOLTAGE-220V DC, O/V VLTAGE SETTING-110%, 1/4NV, 1NO+1NC S/R 1 No.
UNDER VOLTAGE RELAY, NOMINAL VOLTAGE-220V DC, U/V SETTING-80%, AUX..-240V AC, 1/2NH, 1NO+2NC S/R 1 No.
BATTERY EARTH FAULT RELAY, 1-7mA, NOMINAL VOLTAGE-48V DC, 1DV, 2NO S/R, FLUSH 1 No.
OVERLOAD RELAY, NOMINAL VOLTAGE-48V DC, O/V VLTAGE SETTING-110%, 1/4NV, 1NO+1NC S/R 1 No.
UNDER VOLTAGE RELAY, NOMINAL VOLTAGE-48V DC, U/V SETTING-80%, AUX..-240V AC, 1/2NH, 1NO+2NC S/R 1 No.
JAMMING RELAY 1 No.
ELECTRONIC TYPE JAMMING RELAY 1 No.
l) IMC & its modules for Unidirectional Drive
1.1 IMC Upto 5.5KW 1 No.
1.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
2.1 IMC for 5.6 - 7.0KW 1 No.
2.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
3.1 IMC for 7.1 - 13KW 1 No.
3.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
4.1 IMC for 13.1 - 24KW 1 No.
4.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
5.1 IMC for 24.1 - 29.9KW 1 No.
5.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
6.1 IMC for 30.0 - 37.0KW 1 No.
6.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
6.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1 No.
7.1 IMC for 37.1 - 55KW 1 No.
7.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
7.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1 No.
8.1 IMC for 55.1 - 80.0KW 1 No.
8.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
8.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1 No.
9.1 IMC for 80.1 - 89.9KW 1 No.
9.2 Current Sensing Module for above (if not Integral in IMC Module) 1 No.
9.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1 No.
10 Expansion Module for IMC 1 No.
ON DELAY TIMER, 0.5-5SEC., 220V DC, 2NO+2NC 1 No.
ON DELAY TIMER, 1.0-10SEC. 220V DC, 2NO+2NC 1 No.
240VAC MTR RESTART CONTROL TIMER (.2-60SECS) 1 No.
240VAC ON DELAY TIMER(1-10SECNS)WITH 1NO 1 No.
220VDC ON DELAY TIMER(.5-5SECS) WITH 1NO 1 No.
220VDC 0N DELAY TIMER(0.5-5SECS)WITH 3NO 1 No.
220VDC ON DELAY TIMER(1-10SECS) WITH 3NO 1 No.
AC ammeter (Digital) 1 No.
AC ammeter (Analog) linear scale 1 No.
AC ammeter (Analog) compressed scale 1 No.
DC ammeter (Digital) 1 No.
DC ammeter (Analog) 1 No.
DC ammeter with shunt and center zero 1 No.
AC voltmeter (Digital) 1 No.
DC voltmeter (Analog) 1 No.
Wattmeter (3 Phase) 1 No.
Wattmeter (1 Phase) 1 No.
TVM meter 1 No.
DIGITAL ENERGY METER 1 No.
Frequency meter 1 No.
Synchroscope 1 No.
Differential Voltmeter 1 No.
Differential Frequency meter 1 No.
Multifunction digital Energy meter with RS485 Port (0.2 Acc. Class) 1 No.
Multifunction digital Energy meter with RS485 Port (0.5 Acc. Class) 1 No.
Multifunction digital Energy meter with RS485 Port (1.0 Acc. Class) 1 No.
o) Single Phase Preventor Relay 1 No.
6A, 4P 415V AC 1 No.
10A, 4P 415V AC 1 No.
16A, 4P 415V AC 1 No.
6A DP, 240V AC 1 No.
10A DP, 240V AC 1 No.
16A DP, 240V AC 1 No.
32A DP, 240V AC 1 No.
6A DP, 110V AC 1 No.
10A DP, 110V AC 1 No.
16A DP, 110V AC 1 No.
32A DP, 110V AC 1 No.
6A DP, 220V DC 1 No.
10A DP, 220V DC 1 No.
16A DP, 220V DC 1 No.
6A SP, 240V AC 1 No.
10A SP, 240V AC 1 No.
16A SP, 240V AC 1 No.
32A SP, 240V AC 1 No.
6A SP, 110V AC 1 No.
10A SP, 110V AC 1 No.
16A SP, 110V AC 1 No.
32A SP, 110V AC 1 No.
6A SP, 220V DC 1 No.
10A SP, 220V DC 1 No.
16A SP, 220V DC 1 No.
q) SWITCH & PUSH BUTTON
BREAKER CONTROL SWITCH, 16A,220V DC, 2CLOSE+2TRIP 1 No.
DC ISOLATING SWITCH 16A,220V DC, DP, BASE MTG. 1 No.
16A, 240V AC SELECTOR SWITCH 3WAY, 4POLE, FLUSH MTG 1 No.
25A, 240V AC SELECTOR SWITCH 3WAY, 4POLE, FLUSH MTG 1 No.
16A, 240V AC SELECTOR SWITCH 2WAY, 2POLE, FLUSH MTG 1 No.
NORMAL/ TRIAL SEL. SWITCH, 2POLE , 2WAY, 10A 240V AC, FLUSH MTG, 1 No.
MCC/ NORMAL/ TRIAL SEL. SWITCH, 2POLE ,3WAY, 10A 240V AC, FLUSH MTG 1 No.
SWGR/ REMOTE SEL. SWITCH 3POLE 2WAY,16A 220V DC, FLUSH MTG 1 No.
SWGR/ NORMAL/ TRIAL SEL. SWITCH, 3POLE, 3WAY, 16A 220V DC, FLUSH MTG. 1 No.
NORMAL/ TRIAL SEL. SWITCH, 2POLE , 2WAY, 10A 240V AC, FLUSH MTG, LOCKABEL TYPE 1 No.
MCC/ NORMAL/ TRIAL SEL. SWITCH, 2POLE ,3WAY, 10A 240V AC, FLUSH MTG, LOCKABEL TYPE 1 No.
SWGR/ REMOTE SEL. SWITCH 3POLE 2WAY,16A 220V DC, FLUSH MTG.LOCKABLE TYPE 1 No.
SWGR/ NORMAL/ TRIAL SEL. SWITCH, 3POLE, 3WAY, 16A 220V DC, FLUSH MTG., LOCKABLE TYPE 1 No.
AMMETER SELECTOR SWITCH 1 No.
VOLTMETER SELECTOR SWITCH 1 No.
TOGGLE SWITCH 5A, 240V AC 1 No.
AC SWITCH SPST-5A,240V AC 1 No.
10A, 220V DC SWITCH 1 No.
Door Limit switch 1 No.
Ammeter selector switch 1 No.
Voltmeter selector switch 1 No.
Synchronisation selector switch 1 No.
Trip selector switch 1 No.
Push Button 1 No.
2NO + 2NC Shrouded 1 No.
1NO + 1NC Shrouded 1 No.
2NO + 2NC Mushroom head stayput 1 No.
2NO + 2NC Lockable type 1 No.
r) Indicating Lamp Assembly (LED Type)
240V AC-GREEN 1 No.
240V AC-RED 1 No.
240V AC- AMBER 1 No.
110V AC-GREEN 1 No.
110V AC-RED 1 No.
110V AC- AMBER 1 No.
220V DC-WHITE 1 No.
220V DC-RED 1 No.
220V DC-GREEN 1 No.
220V DC-BLUE 1 No.
220V DC- AMBER 1 No.
63.5V AC-RED 1 No.
63.5V AC-YELLOW 1 No.
63.5V AC-BLUE 1 No.
Upto 75/1A 1 No.
ii) Protection CT (5P20)
Upto 75/1A 1 No.
iii) PS Class CT
t) Voltage Transformer
u) Toggle switch (16A) 1 No.
v) Secondary Isolating Contact Block 1 No.
w) Control Terminal (Fixed) 1 No.
x) Control Terminal (Drawout) 1 No.
y) Thermostat, Dial type 1 No.
z) CONTROL TRANSFORMER
415/240V,CL-B, 1 KVA 1 No.
415/240V,CL-B, 2KVA 1 No.
415/240V,CL-B, 2.5KVA 1 No.
415/240V,CL-B, 3KVA 1 No.
415/240V,CL-B, 5KVA 1 No.
415/240V,CL-B, 7.5KVA 1 No.
415/240V,CL-B, 10KVA 1 No.
415/110V,CL-B, 1 KVA 1 No.
415/110V,CL-B, 2KVA 1 No.
415/110V,CL-B, 2.5KVA 1 No.
415/110V,CL-B, 3KVA 1 No.
415/110V,CL-B, 5KVA 1 No.
415/110V,CL-B, 7.5KVA 1 No.
415/110V,CL-B, 10KVA 1 No.
aa) 415/110V,CL-B, 10KVA
4-20mA Dual o/p, Aux sup 220V DC, 1A, Current Transducer 1 No.
4-20mA Dual o/p, Aux sup 240V AC, 1A, Current Transducer 1 No.
4-20mA Dual o/p, Aux sup 110V AC, 1A, Current Transducer 1 No.
4-20mA Dual o/p, Aux sup 220V DC, VoltageTransducer, PTR 415/110V 1 No.
4-20mA Dual o/p, Aux sup 240V AC, VoltageTransducer, PTR 415/110V 1 No.
4-20mA Dual o/p, Aux sup 110V AC, VoltageTransducer, PTR 415/110V 1 No.
4-20mA Dual o/p, Aux sup 220V DC, FrequencyTransducer, PTR 415/110V 1 No.
4-20mA Dual o/p, Aux sup 220V DC, Input 0-75mV DC, Current Transducer-DC 1 No.
4-20mA Dual o/p, Aux sup 240V AC, Input Voltage 0-220V DC, Voltage Transducer-DC 1 No.
4-20mA Dual Output kW transducer 1 No.
4-20mA Dual Output kVA transducer 1 No.
4-20mA Dual Output PF transducer 1 No.
4-20mA Dual Output Frequency transducer 1 No.
ab) Interposing relay RE 302 or Eqvt with freewheeling diode & LED 1 No.
ac) 3 PIN SOCKET - 5A, 110V AC, 3PIN 1 No.
ad) SPACE HEATER 1 No.
ae) NEUTRAL LINK WITH MOUNTING ASSEMBLY
20A FOR CONTROL CKT. & POWER CKT. UPTO 25A MCCB RATING 1 No.
32A FOR 50A MCCB RATING 1 No.
63A FOR 100A & 125A MCCB RATING 1 No.
125A FOR 250A MCCB RATING 1 No.
250A FOR 400A & 500A MCCB RATING 1 No.
af) CASTLE KEY INTERLOCK FOR MCCB - 3LOCK+2KEY 1 No.
ag) MECHANICAL INTERLOCK FOR POWER CONTACTOR
ah) ADDON BLOCK FOR CONTACTOR
1NO + 1NC 1 No.
ai) ISOLATING TRANSFORMER
ISOLATING TRANSFORMER-15kVA 1 No.
ISOLATING TRANSFORMER-20kVA 1 No.
ISOLATING TRANSFORMER-25kVA 1 No.
ISOLATING TRANSFORMER-30kVA 1 No.
aj) ISOLATOR WITH HANDLE
29 Foundation Frame
upto 1600A (SF) 1 No.
2500A (SF) 1 No.
3000A (SF) 1 No.
4000A (SF) 1 No.
upto 1600A (DF) 1 No.
2500A (DF) 1 No.
3000A (DF) 1 No.
4000A (DF) 1 No.
b) 220V DCDB panel
c) PCC / PMCC panel
upto 1600A 1 No.
30 Connection from PMCC/MCC panel to PMCC/MCC panel
31 Cable Glands & Lugs:
a) Single Compression Cable Glands for cable sizes:
2C X 2.5 Sq. mm. 1 No.
3C X 2.5 Sq. mm. 1 No.
5C X 2.5 Sq. mm. 1 No.
7C X 2.5 Sq. mm. 1 No.
10C X 2.5 Sq. mm. 1 No.
14C X 2.5 Sq. mm. 1 No.
2C X 10 Sq. mm. 1 No.
2C X 16 Sq. mm. 1 No.
2C X 25 Sq. mm. 1 No.
2C X 35 Sq. mm. 1 No.
2C X 50 Sq. mm. 1 No.
2C X 70 Sq. mm. 1 No.
2C X 95 Sq. mm. 1 No.
3C X 2.5 Sq. mm. 1 No.
3C X 10 Sq. mm. 1 No.
3C X 16 Sq. mm. 1 No.
3C X 25 Sq. mm. 1 No.
3C X 35 Sq. mm. 1 No.
3C X 50 Sq. mm. 1 No.
3C X 70 Sq. mm. 1 No.
3C X 95 Sq. mm. 1 No.
3C X 150 Sq. mm. 1 No.
3C X 240 Sq. mm. 1 No.
3C X 300 Sq. mm. 1 No.
3.5C X 25 Sq. mm. 1 No.
3.5C X 50 Sq. mm. 1 No.
3.5C X 70 Sq. mm. 1 No.
3.5C X 95 Sq. mm. 1 No.
3.5C X 240 Sq. mm. 1 No.
3.5C X 300 Sq. mm. 1 No.
4C X 16 Sq. mm. 1 No.
4C X 35 Sq. mm. 1 No.
1C X 300 Sq. mm. 1 No.
1C X 630 Sq. mm. 1 No.
b) Double Compression Cable Glands for cable sizes:
2C X 2.5 Sq. mm. 1 No.
3C X 2.5 Sq. mm. 1 No.
5C X 2.5 Sq. mm. 1 No.
7C X 2.5 Sq. mm. 1 No.
12C X 2.5 Sq. mm. 1 No.
16C X 2.5 Sq. mm. 1 No.
2C X 10 Sq. mm. 1 No.
2C X 16 Sq. mm. 1 No.
2C X 25 Sq. mm. 1 No.
2C X 35 Sq. mm. 1 No.
2C X 50 Sq. mm. 1 No.
2C X 70 Sq. mm. 1 No.
2C X 95 Sq. mm. 1 No.
3C X 2.5 Sq. mm. 1 No.
3C X 10 Sq. mm. 1 No.
3C X 16 Sq. mm. 1 No.
3C X 25 Sq. mm. 1 No.
3C X 35 Sq. mm. 1 No.
3C X 50 Sq. mm. 1 No.
3C X 70 Sq. mm. 1 No.
3C X 95 Sq. mm. 1 No.
3C X 150 Sq. mm. 1 No.
3C X 240 Sq. mm. 1 No.
3C X 300 Sq. mm. 1 No.
3.5C X 25 Sq. mm. 1 No.
3.5C X 50 Sq. mm. 1 No.
3.5C X 70 Sq. mm. 1 No.
3.5C X 95 Sq. mm. 1 No.
3.5C X 240 Sq. mm. 1 No.
3.5C X 300 Sq. mm. 1 No.
4C X 16 Sq. mm. 1 No.
4C X 35 Sq. mm. 1 No.
1C X 300 Sq. mm. 1 No.
1C X 630 Sq. mm. 1 No.
c) Cable Lugs for sizes:
1.5 Sq. mm. 1 No.
2.5 Sq. mm. 1 No.
10 Sq. mm. 1 No.
16 Sq. mm. 1 No.
25 Sq. mm. 1 No.
35 Sq. mm. 1 No.
50 Sq. mm. 1 No.
70 Sq. mm. 1 No.
95 Sq. mm. 1 No.
120 Sq. mm. 1 No.
150 Sq. mm. 1 No.
185 Sq. mm. 1 No.
240 Sq. mm. 1 No.
300 Sq. mm. 1 No.
630 Sq. mm. 1 No.
32.1 Thermal O/L relay with SPP - OLR
Upto 5.5KW 1 No.
5.6 to 7.0KW 1 No.
7.1 to 13KW 1 No.
13.1 to 24KW 1 No.
24.1 to 29.9KW 1 No.
30.0 to 37.0KW 1 No.
37.1 to 55.0KW 1 No.
55.1 to 80.0KW 1 No.
80.1 to 89.9KW 1 No.
32.2 Heavy Duty Thermal O/L relay with SPP - OLR
Upto 5.5KW 1 No.
5.6 to 7.0KW 1 No.
7.1 to 13KW 1 No.
13.1 to 24KW 1 No.
24.1 to 29.9KW 1 No.
30.0 to 37.0KW 1 No.
37.1 to 55.0KW 1 No.
55.1 to 80.0KW 1 No.
80.1 to 89.9KW 1 No.
33 Daily 8 hour rate deployed at site:
Engineer : (per day) 1 No.
34 Module Name plate 1 No.
35 Wires for Secondary wiring:
a) 1.5 Sq. mm. per meter 1 No.
b) 2.5 Sq. mm. per meter 1 No.
c) 4.0 Sq. mm. per meter 1 No.
36 Control Terminal for Secondary wiring suitable for cable size:
1) 0.5 Sq. mm. 1 No.
2) 1.5 Sq. mm. 1 No.
3) 2.5 Sq. mm. 1 No.
37 Electrical Junction Boxes (for termination of 0.5 sqmm screened control cables)
a) 48 ways 1 No.
b) 64 ways 1 No.
c) 72 ways 1 No.
a) 96 ways 1 No.
38 ISMC channels
a) ISMC 75 channel per meter 1 No.
b) ISMC 100 channel per meter 1 No.
39 Temperature Sensor for WIRELESS TEMPERATURE MONITORING SENSOR 1 No.
40 Wireless Transmitter for WIRELESS TEMPERATURE MONITORING SENSOR 1 No.
41 Wireless Receiver for WIRELESS TEMPERATURE MONITORING SENSOR 1 No.
42 Additional components (except networking hardware mentioned in Annexure B3) required for completeness of WIRELESS TEMPERATURE MONITORING SENSOR 1 No.
43 DP MCCB, ADJ. SC & O/L Release:
TP MCCB motor duty type with S/C release:
TP MCCB ADJ S/C , O/L, E/F release:
47 SWITCH FUSE UNIT (DC) - DP along with fuse, link etc complete (suitable for 40kA fault current)
48 SWITCH FUSE UNIT (AC) - TP along with fuse, link etc complete
OLM, Profibus DP connector along with accessories (at Y-link end) for interface of Y-Link with DDCMIS. 1 No.
SP ON/ OFF SWITCH FOR MOTOR SPACE HEATER OF BREAKER MOTOR FDR, 10A, 240V AC 1 No.
4 POLE, 2 POSI., SELECTOR SWITCH FOR CONTROL TRF., 110V AC 1 No.
EXTENDED ROTORY HANDLE 1 No.
AUXILIARY CONTACT FOR MCCB 1C/O 1 No.
TRIP CONTACT FOR MCCB 1C/O 1 No.
CONTROL TERMINALS (DRAWOUT) 1 No.
3 PIN INDUSTRIAL SOCKET & PLUG 1 No.
ROTARY ON/OFF SWITCH 1 No.
TIMER WITH 2C/O 1 No.
CONTROL TRANSFORMER, DRY TYPE, CAST RESIN, 415/24V, INS. CL-B OR BETTER 1 No.
RECTIFIER 1 No.
LIMIT SWITCH (BREAKER) 1 No.
Ethernet Switch with 16 Copper Ports & 4 FO ports 1 No.
Ethernet Switch with 08 Copper Ports & 4 FO ports 1 No.
Cat5e/ Cat6 Ethernet Cable 1 No.
Fibre Optic Patch Cord (minimum length - 10metres) 1 No.
9 WINDOWS ALARM ANNUNCIATION -1 1 No.
ELECTRONIC HOOTER (96SQMM) 1 No.
Class 0.2s accuracy energy meters suitable for ABT requirement (Specification in Annexure-I) 1 No.
NOTE: The bidder should list the unit price for any additional modules, components, or items that are not mentioned in the above specifications but may be necessary to fulfill the customer's requirements.
SCHEDULE OF TECHNICAL AND COMMERCIAL DEVIATION
PROJECT:- 2X800 MW NTPC SINGRAULI STPP STAGE – III
PACKAGE:-LT SWITCHGEAR
TENDER REF NO - 77/26/6027/SHA, dated 02-05-2026
NAME OF VENDOR:-
TECHNICAL DEVIATIONS
COMMERCIAL DEVIATIONS
PARTICULARS OF BIDDERS/ AUTHORISED REPRESENTATIVE
NAME DESIGNATIONS SIGN & DATE
1. Cost of withdrawl of deviation will be applicable on the basic price (i.e. excluding taxes, duties & freight) only.
2. All the bidders have to list out all their Technical & Commercial Deviations (if any) in detail in the above format.
3. Any deviation not mentioned above and shown separately or found hidden in offer, will not be taken cognizance of.
4. Bidder shall submit duly filled unpriced copy of above format indicating "quoted" in "cost of withdrawl of deviation" column of the schedule above along with their Techno-commercial offer, wherever applicable. In the absence of same, such deviation(s) shall not be considered and offer shall be considered in total compliance to NIT.
5. Bidder shall furnish price copy of above format along with price bid.
6. The final decision of acceptance/ rejection of the deviations quoted by the bidder shall be at discretion of the Purchaser.
7. Bidders to note that any deviation (technical/commercial) not listed in above and asked after Part-I opening shall not be considered.
8. For deviations w.r.t. Credit Period, Liquidated damages, Firm prices if a bidder chooses not to give any cost of withdrawl of deviation loading as per Annexure-VII, will apply. For any other deviation mentioned in un-priced copy of this format submitted with Part-I bid but not mentioned in priced copy of this format submitted with Priced bid, the cost of withdrawl of deviation shall be taken as NIL.
9. Any deviation mentioned in priced copy of this format, but not mentioned in the un-priced copy, shall not be considered.
10. All techno-commercial terms and conditions of NIT shall be deemed to have been accepted by the bidder, other than those listed in unpriced copy of this format.
11. Cost of withdrawl is to be given seperately for each deviation. In no event bidder should club cost of withdrawl of more than one deviation else cost of withdrawl of such deviations which have been clubbed together shall be considered as NIL.
12. In case nature of cost of withdrawl (positive/negative) is not specified it shall be assumed as positive.
13. In case of descrepancy in the nature of impact (positive/ negative), positive will be considered for evaluation and negative for ordering.
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 12.43 MB
Tendernotice_2.pdf
PDF • 20.51 MB
Tendernotice_3.pdf
PDF • 3.81 MB
Tendernotice_4.pdf
PDF • 0.49 MB
Tendernotice_5.pdf
PDF • 0.85 MB
SCC.pdf
Tender Documents • 0.55 MB
BOQ.xls
Additional Documents • 0.34 MB
Corrigendum07.pdf
PDF • 0.65 MB
Corrigendum06.pdf
PDF • 0.65 MB
Corrigendu05.pdf
PDF • 1.33 MB
Corrigendum04signedfinal.pdf
PDF • 0.32 MB
Corrigendum03.pdf
PDF • 2.84 MB
Corrigendum02.pdf
PDF • 4.83 MB
Corrigenda01.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .