OHE modification work in connection with provision of Track Machine siding at RVK & MDT Station Yard under the work Siliguri - Alipurduar Jn- Provision of Track machine siding - 3 station.
AP-EL-TRD-24-25-26
AP-EL-TRD-24-25-26
Open
12 Months
Alipurduar, West Bengal
₹0
₹1.7 L
5 Jun 2026
5 Jun 2026
15 Jun 2026
-A: OHE modification work in connection with provision of track machine
Preparation of OHE design & drawing
Concrete for foundation/Plinth including supply of sand, ballast & cement.
Supply of fabricated Galvanized Steel Structure i.e. Traction Mast/other special masts (BFB/RSJ/ B-Series etc. as required)
Erection of fabricated Galvanized Steel Structure i.e. Traction Mast/other special masts (BFB/RSJ/ B-Series etc. as required)
Supply of fabricated Galvanized Steel works (SPS) other than Mast including MCC, Chair etc.
Erection of fabricated Galvanized Steel works (SPS) other than Mast including MCC, Chair etc.
Supply of Single Bkt. Assembly complete without insulators for conventional OHE and erection of Single Bkt. Assembly complete with insulators
Erection of Single Bkt. Assembly complete without insulators for conventional OHE and erection of Single Bkt. Assembly complete with insulators
Supply of Stay insulator
Supply of Bracket Insulator
Supply of 9-Tonne Insulator (Porcelain)
Erection of 9-Tonne Insulator (Porcelain)
Supply of Section insulator assembly including core & cut-in insulator.
Erection of Section insulator assembly including core & cut-in insulator.
Supply of regulating equipment, 3 pulley type with counter weight assembly.
Erection of regulating equipment, 3 pulley type with counter weight assembly.
Supply of Guy rod assembly
Erection of Guy rod assembly 1168811.3
Supply of Joint less grooved contact wire 107 sq.mm. made out of continuous cast copper wire RDSO as per Spec. ETI/OHE/76(6/97) with A& C Slip No.- 1,3,4,5,6. 1169649.3
Supply of uninsulated cadmium copper catenary wire 65 sq.mm. 9/2.10mm), confirming to RDSO Specification No. - ETI/OHE/50/(6/1997) WITH A&C Slip No. 1&5.
HD copper dropper wire 5 mm as per RDSO spec. No. IS:282-1982.
Supply of 105sq mm large jumper wire
Supply of Contact Splices
Erection of Contact Splices
Supply of Catenary Splices
Erection of Catenary Splices Per Track
Supply of OHE equipments excluding catenary, contact, jumper and dropper wire Per Track
Erection of OHE equipments including catenary, contact, jumper and dropper wire etc.
Supply of Retro reflective number plate complete as per RDSO's Spec. ETI/OHE/33a (12/97) Rev-6 or latest
Erection of Retro reflective number plate complete as per RDSO's Spec. ETI/OHE/33a (12/97) Rev-6 or latest
Supply of Retro reflective type Power block working limit board
Erection of Retro reflective type Power block working limit board
Supply of Retro reflective type Danger board for 25 KV
Erection of Retro reflective type Danger board for 25 KV
Supply of structure bond
Erection of structure bond
Supply of longitudinal bonds
Erection of longitudinal bonds
Supply of Transverse/Cross /Special bonds
Erection of Transverse/Cross /Special bonds
Supply and fitment of PVC Sleeve for bond Per Track
Adjustment of OHE and Tower Wagon Checking
Supply of single earth electrode with earth pit box cover complete.
Erection of single earth electrode with earth pit box cover complete.
Supply of 25KV single pole isolator with earth contact assembly.
Erection of 25KV single pole isolator with earth contact assembly & post insulator.
Supply of Materials for termination of double overhead equipments conductor.
Erection of Materials for termination of double overhead equipments conductor.
Supply of 25kV Post Insulator
Supply of 18 mm solid copper busbar with components
Supply of Copper Bus-bar terminal (6310)
Supply of bus splice (6320)
Supply of copper jumper wire 160 sq.mm
Dismantling mast/structure/upright by cutting (If required)
Dismantling of cantilever assembly
Dismantling of Regulating Equipments
Dismantling of Guy Rod
Shifting of OHE from old mast to new mast.
Transportation of materials from depot to work site and work site to depot
Terminal connector 19mm multiple hole bolted type complete set with fasteners as per RDSO Drg. No. ETI/OHE/P/1009 Mod-A or latest.
Contact wire Parallel Clamp (157-65/107/150) (1031-3) with GI bolt 16x50x38 mm with nut, washer & spring washer, as per RDSO drawing No. ETI/OHE/P/1030-3, Rev-A
-B: Extra erection charges 100% under power block on Schedule-A
Erection of fabricated Galvanized Steel Structure i.e., Traction Mast/other special masts (BFB/RSJ/ B-Series etc. as required)
Erection of fabricated Galvanized Steel works (SPS) other than Mast including MCC, Chair etc.
Erection of Single Bkt. Assembly complete without insulators for conventional OHE and erection of Single Bkt. Assembly complete with insulators
Erection of 9-Tonne Insulator (Porcelain)
Erection of Section insulator assembly including core & cut-in insulator.
Erection of regulating equipment, 3 pulley type with counter weight assembly.
Erection of Guy rod assembly
Erection of Contact Splices
Erection of Catenary Splices Per Track
Erection of OHE equipments including catenary, contact, jumper and dropper wire etc. Per Track
Adjustment of OHE and Tower Wagon Checking
Erection of 25KV single pole isolator with earth contact assembly & post insulator.
Erection of Materials for termination of double overhead equipments conductor.
Dismantling mast/structure/upright by cutting (If required)
Dismantling of cantilever assembly
Dismantling of Regulating Equipments
Dismantling of Guy Rod
Shifting of OHE from old mast to new mast.
-C: OHE modification work in connection with provision of track machine
Preparation of OHE design & drawing
Concrete for foundation/Plinth including supply of sand, ballast & cement.
Supply of fabricated Galvanized Steel Structure i.e., Traction Mast/other special masts (BFB/RSJ/ B-Series etc. as required)
Erection of fabricated Galvanized Steel Structure i.e., Traction Mast/other special masts (BFB/RSJ/ B-Series etc. as required)
Supply of fabricated Galvanized Steel works (SPS) other than Mast including MCC, Chair etc.
Erection of fabricated Galvanized Steel works (SPS) other than Mast including MCC, Chair etc.
Supply of Single Bkt. Assembly complete without insulators for conventional OHE and erection of Single Bkt. Assembly complete with insulators
Erection of Single Bkt. Assembly complete without insulators for conventional OHE and erection of Single Bkt. Assembly complete with insulators
Supply of Stay insulator
Supply of Bracket Insulator
Supply of 9-Tonne Insulator (Porcelain)
Erection of 9-Tonne Insulator (Porcelain)
Supply of Section insulator assembly including core & cut-in insulator.
Erection of Section insulator assembly including core & cut-in insulator.
Supply of regulating equipment, 3 pulley type with counter weight assembly.
Erection of regulating equipment, 3 pulley type with counter weight assembly.
Supply of Guy rod assembly
Erection of Guy rod assembly 1168811.3
Supply of Joint less grooved contact wire 107 sq.mm. made out of continuous cast copper wire RDSO as per Spec. ETI/OHE/76(6/97) with A& C Slip No.- 1,3,4,5,6. 1169649.3
Supply of uninsulated cadmium copper catenary wire 65 sq.mm. 9/2.10mm), confirming to RDSO Specification No. - ETI/OHE/50/(6/1997) WITH A&C Slip No. 1&5.
HD copper dropper wire 5 mm as per RDSO spec. No. IS:282-1982.
Supply of 105sq mm large jumper wire
Supply of Contact Splices
Erection of Contact Splices
Supply of Catenary Splices
Erection of Catenary Splices Per Track
Supply of OHE equipments excluding catenary, contact, jumper and dropper wire Per Track
Erection of OHE equipments including catenary, contact, jumper and dropper wire etc.
Supply of Retro reflective number plate complete as per RDSO's Spec. ETI/OHE/33a (12/97) Rev-6 or latest
Erection of Retro reflective number plate complete as per RDSO's Spec. ETI/OHE/33a(12/97) Rev-6 or latest
Supply of Retro reflective type Power block working limit board
Erection of Retro reflective type Power block working limit board
Supply of Retro reflective type Danger board for 25 KV
Erection of Retro reflective type Danger board for 25 KV
Supply of structure bond
Erection of structure bond
Supply of longitudinal bonds
Erection of longitudinal bonds
Supply of Transverse/Cross /Special bonds
Erection of Transverse/Cross /Special bonds
Supply and fitment of PVC Sleeve for bond Per Track
Adjustment of OHE and Tower Wagon Checking
Supply of single earth electrode with earth pit box cover complete.
Erection of single earth electrode with earth pit box cover complete.
Supply of 25KV single pole isolator with earth contact assembly.
Erection of 25KV single pole isolator with earth contact assembly & post insulator.
Supply of Materials for termination of double overhead equipments conductor.
Erection of Materials for termination of double overhead equipments conductor.
Supply of 25kV Post Insulator
Supply of 18 mm solid copper busbar with components
Supply of Copper Bus-bar terminal (6310)
Supply of bus splice (6320)
Supply of copper jumper wire 160 sq.mm
Dismantling mast/structure/upright by cutting (If required)
Dismantling of cantilever assembly
Dismantling of Regulating Equipments
Dismantling of Guy Rod
Shifting of OHE from old mast to new mast.
Transportation of materials from depot to work site and work site to depot
Terminal connector 19mm multiple hole bolted type complete set with fasteners as per RDSO Drg. No. ETI/OHE/P/1009 Mod-A or latest.
Contact wire Parallel Clamp (157-65/107/150) (1031-3) with GI bolt 16x50x38 mm with nut, washer & spring washer, as per RDSO drawing No. ETI/OHE/P/1030-3, Rev-A
-D: Extra erection charges 100% under power block on Schedule-C
Erection of fabricated Galvanized Steel Structure i.e., Traction Mast/other special masts (BFB/RSJ/ B-Series etc. as required)
Erection of fabricated Galvanized Steel works (SPS) other than Mast including MCC, Chair etc.
Erection of Single Bkt. Assembly complete without insulators for conventional OHE and erection of Single Bkt. Assembly complete with insulators
Erection of 9-Tonne Insulator (Porcelain)
Erection of Section insulator assembly including core & cut-in insulator.
Erection of regulating equipment, 3 pulley type with counter weight assembly.
Erection of Guy rod assembly
Erection of Contact Splices
Erection of Catenary Splices Per Track
Erection of OHE equipments including catenary, contact, jumper and dropper wire etc. Per Track
Adjustment of OHE and Tower Wagon Checking
Erection of 25KV single pole isolator with earth contact assembly & post insulator.
Dismantling mast/structure/upright by cutting (If required)
Dismantling of cantilever assembly
Dismantling of Regulating Equipments
Dismantling of Guy Rod
Shifting of OHE from old mast to new mast.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureVIB3.pdf
ATTACHMENT
AdditionalTermsandconditions.pdf
ATTACHMENT
Chapter-ll.pdf
ATTACHMENT
ExplanatoryNotesofschedule_compressed.pdf Explanatory Notes of Schedule
ATTACHMENT
ANNEXURE-IFirstsheetlatestmodified.pdf
ATTACHMENT
ANNEXURE-VA.pdf
ATTACHMENT
ANNEXURE-V.pdf
ATTACHMENT
ShramikKalyaninstruction.pdf
ATTACHMENT
GCC-2022-ACS10_1_1.pdf
ATTACHMENT
ACS11GCCWorks2026March.pdf
ATTACHMENT
ExplanatoryNotesofschedule_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid