Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Value | |
| 2 | L2₹13.9 L+₹4.1 L (41.3%)Rejected-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L2 | Rejected-Finance Higher Bid Value | |
| 3 | L3₹17.4 L+₹7.6 L (76.8%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
15 Jul 2021, 6:55 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA, KALAIKUNDA AIR FIELD POST, DIST- WEST MEDINIPORE, 721303
REPAIR/MAINT OF AC PLANTS, AHU AND OTHER ALLIED WORKS
2021_MES_452237_1
8383/KKD/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
AT AF STN SALUA
Class E category c(i)
2 documents required · 2 mandatory
₹500
Yes
GE AF KALAIKUNDA
₹50,000
Yes
6 Aug 2021
17 Jun 2021
17 Jul 2021
17 Jun 2021
15 Jul 2021
1 Jul 2021
18 Jun 2021 - 25 Jun 2021
Amount
S&F in repair expansion valve required for AC plant of Capacity 5.5 TR Complete all as specified and directed by Engr- in- Charge .
M&L for cleaning of evaporator coils of AC plant of capacity 5.5 TR with dilute HCL by force feed method to remove the dust particle formed on the coil & fins,cleaning of liquid lines stainer expansion valve complete all as specified and directed by Engr- in- Charge .
M&L for servicing including cleaning of condensor , cooling coil,refrigerant coils fins with mild detergent and descaling of condensor coil for Package type 5.5 TR AC of including leake testing with N2 gas any make/ capacity complete all as specified and directed by Engr- in- Charge .
Disconnecting, dismantling and taking out existing burnt out compressor of package type AC 5.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity , single phase, 230 V AC supply initialy filled with compressor oil/gas as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and directed by Engr- in- Charge .
M&L for servicing including cleaning of condensor & evaporator coils fins with mild detergent and descaling of condensor coil for split type AC of any make/ capacity after taking down the whole unit and refixing at the existing location or any other new location after servicing all as specified and directed by Engr- in- Charge .
M&L for taking out burnt winding of 1 HP blower motor outdoor/indoor and rewinding with new winding as per existing specificatation complete all as specified and directed by Engg- in - charge .
M&L for taking out burnt winding of 2 HP blower motor outdoor / indoor and rewinding with new winding as per existing specificatation complete all as specified and directed by Engg- in - charge .
Supply fixing in replacement of V Belt of size A-28 suitable for 5.5 TR Capacity package Unit AC all as specified and directed by Engg- in - charge .
M&L micro filter for AC Plant of capacity 5.5 TR complete all as specified and directed by Engg- in - charge .
M&L Air filter for AC Plant of capacity 5.5 TR complete all as specified and directed by Engg- in - charge .
Supply fixing in repair canvas cloth in between AHU and cold air duct of AC plant after removing the unserviceable cloth complete all as specified and directed by Engg- in - charge .
Supply fixing in repair AC duct made up GI Sheet in existing location as per existing (900x450) mm size including proper insulation by glass wool & alluminium foil all as specified and directed by Engg- in - charge .
Supply fixing in repair Microprocessor with and including display ckt , sensors and display cable for 16.5 TR package type AC complete all as specified and directed by Engg- in - charge .
Taking out blower motor shaft from AC plant of capacity 5.5 TR , welding and grinding on lathe machine to make suitable allignment with bearing then refixed complete all as specified and directed by Engg- in - charge
S&F in repair runner of fan motor drum for package AC plant of capacity 5.5 TR complete all as specified and directed by Engg- in - charge
S&F in repair fan blade of outdoor unit of AC plant of capacity 5.5 TR complete all as specified and directed by Engg- in - charge
S&F connector for 30-40 AMPS , 440 volts complete all as specified and directed by Engg- in - charge
S&F MCCB 160 AMPS adjustable type , 4 pole , 25 KA complete all as specified and directed by Engg- in - charge
S&F Auto change over switch for package type AC plant 11 TR complete all as specified and directed by Engg- in - charge
Supply and charging R-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling applinces (charging cost including in this item) complete all as specified and directed by Engr- in- Charge .
Supply and charging R-407C Gas to maintain the required cooling effect as and when required in the Package type AC plant including (charging cost including in this item) complete all as specified and directed by Engr- in- Charge .
Taking down old Alluminium/Copper Sub main wiring and M&L for new Sub main wiring of cassing and capping using Two single core PVC insulated cable(FRLS) 4 sqmm copper conductor multi stranded and One 4 sqmm copper conductor insulated cable (FRLS)using as earth wire and drawing into and including PVC cassing capping Complete all as specified and directed. Note:- One run of PVC cassing capping & three run of 4 sqmm copper wire measured as one Unit .
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15mm thick buried directly in ground in earth pit diggiged in any type of soil/ strata (Earth plate not less than 3.0 M in deep below ground level) with top edge of the plate not less than 2.4m below normal ground level connected to copper earth strip 20x3 mm by means of brass bolts, nuts, check nuts and washers of brasss -03 Nos including brazing of copper strip , filling of remaining portion of pit with low resistivity agriculture soil bring from out side defence land, connecting strip to earthing test point including necessary earth work in any type of strata and PCC 1:3:6 type B1 for chamber and RCC chamber cover 50mm thick in lieu of CI cover, copper strip to be protected by providing 40mm GI pipe light grade and water pipe of 32 mm medium grade with funel and wire mess complete all as directed by Engineer-in-charge. Note :- (a). The quoted rate includes the rate of Magnesium Sulphate of 40Kg per earth pit poured with salt and charcoal layed in layer in pit to obtain low earth resistance value. (ii) Contractor shall test the earth pit in presence of MES rep and prepare test sheet of newly constructed earth pit . (iii). If the desired earth resistance not obtained the earthing shall be re-done by contractor without any extra cost to Govt . (iv) 40 mm dia light grade GI pipe for earth lead strip protection and 32 mm medium grade pipe for watering and earth strip up to 7.5 Mtr incl in quoted rates beyond that both are measured and paid separetely. (v) Filling of agriculture sand brought from out side defence land shall be included in the unit rate . No extra payment shall be paid for this by the department. (vi) Display plate made of MS sheet of size 300 mm x 200 mm x 3 mm welded to MS square bar to be fixed by contractor on each earthing without any extra cost.
S&F in replacement of insulation Nnytriyle rubber 1/6 size including fixing all as specified and directed by Engineer-in-charge.
All as per item No 24 here-in-before but 1/8 size including fixing complete all as specified and directed by Engineer-in-charge.
All as per item No 24 here-in-before but 5/8 size including fixing complete all as specified and directed by Engineer-in-charge.
S&F in replacement of Copper pipe of size 1/4 size including fixing by brazing and jointing all as specified and directed by Engineer in charge.
All as per item No 27 here-in-before but size 1/2 size including fixing by brazing and jointing all as specified and directed by Engineer in charge.
All as per item No 27 here-in-before but size 5/8 size including fixing by brazing and jointing all as specified and directed by Engineer in charge.
S&F in replacement of overload relay for 1.5 TR AC as per existing and making all electrical connections all as specified and directed by Engineer in charge.
S&F in replacement of overload relay for 2.0 TR AC as per existing and making all electrical connections all as specified and directed by Engineer in charge.
Supply and Charging R-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling appliance complete all as specified and directed.
Supply and charging Nitrogen gas Gas for finding out leakage as and when required as specified and directed by Engr in charge.
S&F in replacement of Auto transfer switch suitable for Voltas Make 16.5 TR capacity package type Air conditioner for alternate running of AC at regular interval all as specified and directed by Engr- in- Charge .
S&F in replacement of Printed Circuit Board with CT coil complete suitable for 16.5 TR capacity Package type AC Plant.
Supply & fixing in replacement of Capacitor 36 MFD complete all as specified by Engr- in- Charge .
Supply & fixing in replacement of Capacitor 45 MFD complete all as specified by Engr- in- Charge .
Supply & fixing in replacement of Capacitor 50+6 MFD complete all as specified by Engr- in- Charge .
Supply fixing in replacement of Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, etc.
Supply fixing in replacement of Printed Circuit Board suitable for 1.5 TR Capacity Split Unit Air Conditioners including remote, etc.
Supply and fixing in repair Capillary tube of size 50 / 60 Suitable for split/ window type AC of capacity 1.5/2.0 Ton Make-Kirloskar/ Carrier /LG/ Godrej/ Blue Star or equivalent make as approved by GE
Supply and fixing in repair Bracket stand suitable for 2 TR Capacity Split type AC including Fastners, etc or equivalent make as approved by GE
M&L for Copper codensing coil for 2 TR split type AC as per existing size all as directed by the Engineer - in-charge.
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor gas as specified by Engr-in-charge.
All as per srl item No. 44 here-in-before but Cap 1.5 TR Single phase 230 volts AC 50 Hz supply complete all as specified and directed by Engr-in-charge.
M&L for Shifting of split type AC from MES yard / existing location to the new location by taking it out after filling the opening of old location with cement mortor, applying white wash on wall with matching with existing colour of the site and making opening holes on brick wall at new location and gap well finished with cement mortor, applying white wash, colour wash, distemper etc on wall to match with existing colour of the adjacent surface , installation and commissioning with replacement of insulation of suction & discharge line complete all as specified and directed by Engr-in-charge.
M&L for Shifting of window type AC from MES yard / existing location to the site/ new location where directed & installation by making necessary opening of brick wall/ window and preparing gap well finished by cement mortor applying white washing in matching with the existing colour, disposal of waste material/ filling gap with ply wood on front side of AC and outer corner of ply wood applying two coats of enamelled paint over a coat of primer on plywood surface to match the existing location all as directed by the Engr-in-Charge.
Supply & fix switch fuse metal clad single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engr-in-charge.
MS R.K.ENTERPRISE
SENCO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .