Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹6.9 L+₹35,825 (5.48%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹7.0 L+₹42,545 (6.51%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹7.3 L+₹78,660 (12.0%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹8.0 L+₹1.5 L (22.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 Jun 2020, 6:00 pmClosed
GE BHOPAL
GE BHOPAL
REPAIRS AND MAINT OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, ETC AND CONNECTED WORKS AT SI LINES UNDER GE BHOPAL
2020_MES_346030_1
8661/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
Class E Category b i
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹20,000
Yes
31 Aug 2020
19 May 2020
17 Jun 2020
19 May 2020
15 Jun 2020
2 Jun 2020
Amount
NOTE: - (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the AGE E/M Bairagarh subdivision in present of concern JE E/M. (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per BOQ serial item No.1.10 above but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.1.10 above but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.1.10 above but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts.
All as per BOQ serial item No.1.10 above but wall / pedestal fan, of any sweep and capacity
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber Bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement flexible copper conductor stranded 1100 Volt PVC insulated cable twin core twisted 23/0.0076 size complete all as specified and directed.
S&F in replacement Fan condenser 2.5 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
S&F in replacement Fan condenser 3.15 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
S&F in replacement Fan condenser 4.0 mfd, 230 volts complete all as specified and directed. [Make: Epcos/Tibcon as approved by GE]
Supply only the following items for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed.
Bearing No 6201'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Bearing No 6202'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Bearing No 6203'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Bearing No 6204'ZZ' [Make : SKF/NBC/FAG as approved by GE]
Taking down ceiling / wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i e. connector/ condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement Exhaust fan blade duly powder coated suitable for 450 mm/380mm sweep as per existing complete all as directed .
S&F in replacement Exhaust fan blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as directed .
S&F in repairs blade assembly of celling fan of 1200 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan of 1400 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under item No. 1 here-in-before.
Ceiling fan upto 1200/1400 mm sweep complete.
Exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint
S&F ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nut and bolt, etc and reassembling, re-fixing and testing the fan complete all as specification and directed.
M&L for rewinding of wall mounting fan of any sweep and any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
Removing unserviceable fan / bearing shaft (of any type & fan) and shaft welding broken area and threading in lathe machine at appropriate size and refixing in ceiling fan, any type complete all as specified and directed.
Fixing only ceiling fan any type, marking MES NO. and connecting flexible wire from ceiling rose to fan complete with all acessories and down rod complete all as specified and directed. Note:Ceiling fan shall be issued under schedule B free for fixing only
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.33.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.33.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No.33.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 3 pin, 5 Amp and 2 pin, 5 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch socket combination, multipurpose, 6 pin, 5-15 Amp, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Dismantling geyser of 25 ltrs capacity and of any description, M&L for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position and its testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. NOTE:- (i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of BOQ (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares as required shall be measured and paid seperately.
All as per BOQ Sl No. 40.00 above but geyser of capacity 50 Ltrs .complete all as specified and directed.
S&F 1.5 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as specified and directed. [Make: Bajaj/ Usha /Theta or as recommanded by manufacturer or equivalent as approved by GE.]
S&F 2.0 KW capacity Heating Element, Push/ Screw type with ‘O’ ring including making electrical connection complete all as specified and directed. [Bajaj/ Usha /Theta or as recommanded by manufacturer or equivalent as approved by GE.]
S&F in replacement Geyser assembly suitable for 25 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement Geyser assembly suitable for 50 ltr capacity, ISI marked complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr Geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed. [Make : Danfoss / Ranco / Indfoss or as recommanded by manufacturer or equivalent as approved by GE.]
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement Indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos complete all as specified and directed.
Geyser 25 ltr capacity
Geyser 50 ltr capacity
S&F in replacement single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V,complete with and including one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top complete all as specified and as directed. [Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T as approved by GE.]
S&F in replacemnt PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. [MAKE:-PRAYAG/ POLYTUFF as approved by GE]
S&F in replacemnt PVC connection Nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified & directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
S&F in replacement Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH as approved by GE]
S&F in replacement Steel water tubes, medium grade, ISI marked, galvanised, 20 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH as approved by GE]
S&F in replacement GI socket 15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI union 15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI Elbow 15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI Nipple 15mm dia 100 mm long ISI marked complete all as specified & directed.
S&F in replacement GI Tee equal15x15x15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI Tee 20x20x15mm dia ISI marked complete all as specified & directed.
S&F in replacement GI socket reducer 20 x 15mm ISI marked complete all as specified and directed.
S&F in replacement stop valves ISI marked, 15mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends fancy type, chromium plated for iron pipe or for unions etc complete all as specified and directed. [Make: Prayag / PRIMA / Jainko as approved by GE]
S&F in replacement Bib tap, ISI marked, 15mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends fancy type, chromium plated for iron pipe or for unions etc complete all as specified and directed. [Make: Prayag / PRIMA / Jainko as approved by GE]
S&F in replacement PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified & directed. [Make:-Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE]
Deduct schedule of credit (calculation will be done off line) Rs.39,113.00
M/S SHARADA ASOCIATE
MODI CORPORATION
UMESH ENTERPRISES
HARJEE ENTERPRISES
ELITE WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .