Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical TECH QUALIFIED |
| 2 | Accepted-Technical | Accepted-Technical TECH QUALIFIED |
| 3 | Accepted-Technical | Accepted-Technical TECH QUILIFIED |
| 4 | Accepted-Technical | Accepted-Technical TECH QUILIFIED |
Tender Value
₹8.4 L
EMD Value
₹8,500
Closing Date
6 May 2026, 5:00 pmClosed
CMO DATIA
cmo nagar palika datia
Repair and Maintenance Work for Streetlights Smart City on Sitasagar Lake Bypass
2026_UAD_495965_1
STORE/805/31-03-2026
Open Tender
Miscellaneous Works
Item Rate
DATIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Yes
₹8,500
Yes
8 May 2026
31 Mar 2026
7 May 2026
31 Mar 2026
6 May 2026
31 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Laying and Jointing PVC Pipe. Heading | |||||
| 1.01 | Supply of XLPE Insulated power calbe (conforming IS-7098) 1100 Volt grade /Heavy duty power cable conforming to IS 1554- 1100 Volts grade. 2 core / 31/2 core/4 coreISI MARKED with Alu.Stranded / solid conductor Armoured 4 Core - 25 Sq.mm. (XLPE) | - | Mtr | - | - |
| 1.02 | Supply of XLPE Insulated power calbe (conforming IS-7098) 1100 Voit grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade. 2 core / 31/2 core/4 coreISI MARKED with Alu. Stranded / solid conductor Armoured 4 Core - 10 Sq.mm. (XLPE) | - | Mtr | - | - |
| 1.03 | Supply of Double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked ) for cable laid under ground with necessary connecting sockets/ couplings,tees of same material .50.00mm outside dia. | - | Mtr | - | - |
| 1.04 | Supply of Double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked ) for cable laid under ground with necessary connecting sockets/ couplings,tees of same material .77.00mm outside dia. | - | Mtr | - | - |
| 1.05 | Laying of one number PVC insulated and PVC sheathedd power cable of 1:1 kV grade of size not exceeding 25 Sq.mm in the existing RCC Hume/Stone/Ware/G.I. pipe as required. | - | Mtr | - | - |
| 1.06 | Suppying & installing G.I. Pipe for protection of underground cable fixed on wall/support/ in trench/ fixed between two rigid existing support of wall/ beam for erection of ceiling Fan/ down rod for stiff pendent for light luminaries/ fan/ protective for earthing, lightening conductor down strip/ everhead service line/ for submer cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, te, elbow, nuts and bolts etc. complete in an approved manner as required to complete the job excluding cost of excavation/ dismateling & other finished masonary Item complete. A'Class G.I. Pipe ISI Marked (IS-1161- 69) (Road RRossing) 80 mm dia | - | Mtr | - | - |
| 1.07 | Supplying, fixing,testing & commissioning wall / floor mounted LT Panel primer coated with two coat of enamel paint & provided with required gasket for dust/ vermin proof with degree of protection IP42 suitable for 415V 3 phase,50 Hz ,4 wire system fabricated out of CRCA sheet upto 2 mm thick(1.6 mm for doors) with frame work of angle iron/ channel/ bolted type construction duly compartmentalised for incomer,bus section , outgoings,cable alleys & CT,PT Ampere Meter ,Volt Meter , selector switches,Frequency Meter,phase indicating lamps , energy Meter complete including cost of busbar supports,detachable cable gland plates,2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs,panel mounted Changeover switch/SFUs, etc. as required but | - | Each | - | - |
| 1.08 | Supply of ISI marked and approved make of Maulded case circuit Breaker MCCB suitable for 3 phase 3 pole 50 HZ 415 volt AC Supply with respective Interrupiting Capacity (KA ) at 415 Volt cited againest their range standerd confirming to IS -8828 MCCB with breaking capacity 25 kA at 415 V current rating - 25 to 100 amps & 70%-100% adjustable | - | Each | - | - |
| 1.09 | Supply, Installation, testing and Commissioning of 25 A rating four pole contractor, designed specific contrat material AgSnO2 for lamp loads and AC load for high starting current. It shall work at an ambient temperature of( - 20 ) to (+ ) 50 deg C and auto-On- Off selector version. It shall have 3 Kv short circuit protections. The mounting shall be on 35 mm DIN rail (EN 60715 ) | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
Tendernotice_2.pdf
PDF • 0.92 MB
BOQ_594635.xls
BOQ • 0.30 MB
495965.pdf
PDF • 0.30 MB
2026LIGHT.pdf
PDF • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .