Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-AOC HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | ₹48.8 L Quoted ₹49.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹54.6 L+₹4.6 L (9.25%)Rejected-Finance CHOTHRAPUR BRICHGUNJ POST PORT BLAIR SOUTH ANDAMAN 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹54.6 L+₹4.6 L (9.25%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹55.3 L+₹5.4 L (10.8%)Rejected-Finance | ₹55.3 L+₹5.4 L (10.8%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹55.5 L+₹5.6 L (11.2%)Rejected-Finance | ₹55.5 L+₹5.6 L (11.2%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹55.7 L+₹5.7 L (11.4%)Rejected-Finance NEAR PLAY GROUND BIRDLINE CALICUT POST PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹55.7 L+₹5.7 L (11.4%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
28 Mar 2024, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
SPECIAL REPAIRS TO BUILDING NO.P-21 AT HQ 34 WEU UNDER GE MINNIEBAY, PORT BLAIR
2024_MES_645610_1
8380/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹96,000
Yes
7 Jun 2024
8 Mar 2024
30 Mar 2024
8 Mar 2024
28 Mar 2024
22 Mar 2024
Amount
Demoliton of cement concrete including tiles and mortar of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer in charge
Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbished off the premises complete all as specified and as directed by Engineer in charge
M&L for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) with roughned face to receive top finishing layer complete all as specified and as directed by Engineer in charge
M&L for non skid joint free coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cenment slurry over & including 15mm thick screed bed in CM 1:4 and pointed in white or coloured cement to match complete all as specified and as directed by Engineer in charge
M&L for ceramic tiles edge to edge joint 7 to 8 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match tiles including 10 mm thick backing plaster in CM (1:4) complete all as specified and as directed by Engineer in charge
M&L for non skid joint free coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over & including 15mm thick screed bed in CM 1:4 and pointed in white or coloured cement to match complete all as specified and as directed by Engineer in charge
M&L for glazed ceramic coloured tiles 450x300x7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing in cement mortar (1:3) complete all as specified and as directed by Engineer in charge
Dismantling stone slab of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and as directed by Engineer in charge
M&L for granite (of any type) 16 to 20 mm thick machine cut fixed on steps/riser, slab,window cill etc , bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting, moulding & polishing over and including 20 mm thick screed in CM (1:4) complete all as specified and as directed by Engineer in charge
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer in charge
S & F in repair Solid PVC Door frame of size 50mm x 47mm made out of 5mm rudraksh colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer in charge
S&F in repair factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of rudraksh colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer in charge
Taking down chowkats or frames not exceeding 1.5 Sqm (with shutters & grill (if fixed) without taking off shutters from the frame) complete all as specified and as directed by Engineer in charge
Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm (with shutters and grill (if fixed) without taking off shutters from the frame)
M&L for powder coated anodised aluminium frame for doors, windows, ventilators and partition with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer in charge
S&F Powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc including fixing of plain sheet glass & particle board complete all as specified and as directed by Engineer in charge Note: Plain sheet glass and Particle board shall be measured and paid separately as "Supply only"
S & F Powder coated anodised aluminium window and ventilator shutters, side hung type with or without sash bars, aluminium sections weighing 0.55 kg/m and thickness of section not less than 1.6 mm including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) including fixing of plain sheet glass and aluminium alloy wire cloth complete all as specified and as directed by Engineer in charge Note: Plain sheet glass and aluminium alloy wire cloth shall be measured and paid separately as "Supply only"
Supply only 4 mm Plain sheet glass ordinary quality ,in square exc 0.5 sqm each complete all as specified and as directed by Engineer in charge
Supply and fix in repairs 4 mm Plain sheet glass ordinary quality ,in square exc 0.5 sqm each complete all as specified and as directed by Engineer in charge
Supply only 5.0 mm thick figured glass, pin head type and glazing with oil putty in squares in n.exc 0.5 sq.m in each pane complete all as specified and as directed by Engineer in charge
Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge
Supply and fix in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge
Supply only Particle board 12mm, medium density, flat pressed, single layer type or three layer type with BWR type adhsive, fixed with aluminim doors/ partition etc complete all as specified and as directed by Engineer in charge
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed by Engineer in charge
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed by Engineer in charge
S&F Aluminium anodised barrel tower bolt of extruded section 150 mm long complete all as specified and as directed by Engineer in charge
S&F Aluminium anodised barrel tower bolt of extruded section 100 mm long complete all as specified and as directed by Engineer in charge
S&F Extruded aluminium alloy handle fabricated type anodised 100mm long complete all as specified and as directed by Engineer in charge
S & F 100mm length Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 including srews complete all as specified and as directed by Engineer in charge
S & F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor complete all as specified and as directed by Engineer in charge
S & F in repair fancy type curtain Rod, stainless steel,chromium plated 25 mm dia with stops, rollers etc complete all as specified and as directed by Engineer in charge
S & F in repair brass brackets chromium plated suitable for curtain Rod 25 mm dia complete all as specified and as directed by Engineer in charge
Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer in charge
M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed by Engineer in charge
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer in charge
M & L for rendering to concrete or block masonry surfaces or surfaces other than fair faces of brick surfaces, 10mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer in charge
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and as directed by Engineer in charge Note: Water proofing compound will be measured and paid separately.
M&L for applying polymer modified cement mortar rendering 15mm average thick in CM 1:3 on concrete surface duly mixing polymer modifier 'Nitobond AR' of make: M/s Fosroc Chemicals India (P) Ltd. @ 10 Ltr per bag of cement or equivalent in M/s Harjas Coatings & Polymers @ 5% by wt of cement / M/s Pidilite Industries complete finished even and smooth without using extra cement all as specified and as per manufacturer's instructions complete all as specified and as directed by Engineer in charge
M & L for rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in charge
Supply only Integral water proofing compound complete all as specified and as directed by Engineer in charge
M & L for providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed by Engineer in charge
M&L for preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
M&L for preparing newly plastered surfaces of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed by Engineer in charge
M&L for newly plastered surfaces , providing necessary scaffolding & safety precautions and cleaning the surfaces free from any loose paint, dust, greases, growth of fungus, algae or moss using wire brush and levelling the surface even smooth using mechanical sander and finally applying water by pressure jet washer of max pressure of 170 bar with automatic pressure relief system. The following process shall be initiated only after the above surface preparations :-
(a) Filling the surface cracks using crack seal compound on required consistency using electric mixer. (b) Filling the dents and holes using wall care putty in appropriate ratio using electric mixer. (c) Applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m. (d) Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives
1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smoothemulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m Note: (1) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR (iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work. (iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats.
(v) Building wise stage passing register shall be maintained & submitted alongwith RAR/FB duly signed by Engr-in-Charge and contractor. (vi) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used. (viii) Proper masking arrangement shall be carried before the application of primer or paint. (ix) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions. (x) Cost of scaffolding shall be included in the quoted rate.
M & L for complete removel of existing treatment on wall & finishing the surface and appliying two coat of oil bound distemper over primer coat complete all as specified and as directed by Engineer in charge
M&L for complete removal of old existing treatment/ finishes providing necessary scaffolding & safety precautions and cleaning the surfaces free from any loose paint, dust, greases, growth of fungus, algae or moss using wire brush and levelling the surface even smooth using mechanical sander and finally applying water by pressure jet washer of max pressure of 170 bar with automatic pressure relief system. The following process shall be initiated only after the above surface preparations :-
(a) Filling the surface cracks using crack seal compound on required consistency using electric mixer. (b) Filling the dents and holes using wall care putty in appropriate ratio using electric mixer. (c) Applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m. (d) Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives
1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smoothemulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m Note: (1) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR (iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work. (iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats.
(v) Building wise stage passing register shall be maintained & submitted alongwith RAR/FB duly signed by Engr-in-Charge and contractor. (vi) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used. (viii) Proper masking arrangement shall be carried before the application of primer or paint. (ix) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions. (x) Cost of scaffolding shall be included in the quoted rate.
Removing loose and broken concrete/ masonary surface by chiseling/ mechanically etc from the roof slab, coloumn, beam and similar structural members cutting edges, cleaning the dismantled portion with wire brush etc to make the reinforcement naked and remove dust, dirt and other foreign particle etc and removig to debries 50 Mtr from site complete all as specified and as directed by Engineer in charge
M/L for applying IPH RB -107 polymer based rust-remover (pH value –12 ) and applying IPH RB -167 Polymer based rust preventive (pH value-9) to all exposed reinforced bars complete all as specified and as directed by Engineer in charge
M/L for applying one coat of epoxy bonding coat as per manufacture's instruction to bind with old concrete / wall surfaces of soffit of slab, coloumn, beam and similar structural members for new cement surface complete all as specified and as directed by Engineer in charge Make : IPH 21 EB of Harjas Coatings & Polymers / Nitobond EP of FOSROC or equivalent make in Dr. Fix it of Pidilite Industries / MC Bauchemie / BASF
Dismantling of ceiling boarding in description fixed in any position with nails complete all as specified and as directed by Engineer in charge
S&F Aluminium anodised snap grid false ceiling of standared aluminium section of size 38mm x 25mm x 24mm , weight 0.363 Kg/RM main/cross tees of size 38.5mm x 25mm x 1.4mm weight 0.24 Kg/RM, Grid size n.Exc 610mm x 610mm suspended false ceiling with 4mm dia Gi wire interval n exc 600mm centre to centre for main & cross tees fixed to roof slab , roof truss fixed with suitable size MS hook and fastening bolts etc incl E board classic 4 mm thick oceanic sheer of size n exc 610mm x 610mm size fixed in ceiling with clips to aluminium snap grid and preparation of new surface and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed by Engineer in Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer in charge
M&L for cutting holes into or through reinforced cement concrete slabs, chajjas, etc reibforced or otherwise exc 500 sqcm but not exc 0.1 Sqm complete all as specified and as directed by Engineer in charge
M & L for providing cement concrete type B1 (1:2:4) using 20 mm graded aggregate as in copings,apex stones,bed plates etc including formwork complete all as specified and as directed by Engineer in charge
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed by Engineer in charge
S&F MS Roof trusses (Framed), trussed, purlins, rafters, crane gantries, rails ,posts and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.including necessary welding confirming to Fe-410-W(Gde-E250 quality-A) complete all as specified and as directed by Engineer in charge
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410 W (Grade E-250) quality A. complete all as specified and as directed by Engineer in charge
S & F Mild steel screw bolts (machine made) of 5 to 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n.exc. 10 cm long complete all as specified and as directed by Engineer in charge
M&L for preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in charge
Dismantling plain or corrugated steel sheeting,any gauge, thickness,including nanital or similar pattern roof coverings complete all as specified and as directed by Engineer in charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction complete all as specified and as directed by Engineer in charge
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed by Engineer in charge
S&F aluminium flat 40 X 6mm size as wind tie fixed with 50mm/75mm aluminium self staging screws complete all as specified and as directed by Engineer in charge
Taking up or down 20 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
Taking up or down 25 mm bore tubing and connections and removing off the site complete all as specified and as directed by Engineer in charge
Supply and laying of CPVC pipes 20 mm dia outer boreSDR 11 &plain CPVC SDR 11with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge
Supply and laying of CPVC pipes 25mm dia outer boreSDR 11 &plain CPVC SDR 11 with all special fittings on walls /ceilings or laying in floors complete all as specified and as directed by Engineer in charge
Supply and fixing 20 mm outer dia CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia CPVC Male Brass Threaded Adaptor complete all as specified and as directed by Engineer in charge
Supply and fixing 20 mm outer dia CPVC pipes brass Elbow complete all as specified and as directed by Engineer in charge
Supply and fixing 20mm outer dia CPVC pipes brass Elbow (3/4 X1/2) complete all as specified and as directed by Engineer in charge
Supply and fixing 20mm outer dia CPVC female brass adaptor complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia CPVC female brass adaptor complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia tank Adaptor complete all as specified and as directed by Engineer in charge
Supply and fixing 20mm outer dia union complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia union complete all as specified and as directed by Engineer in charge
Supply and fixing 20 mm outer dia Brass Tee complete all as specified and as directed by Engineer in charge
Supply and fixing 25 mm outer dia Brass Tee complete all as specified and as directed by Engineer in charge
S&F Rotational moulded polyethylene water storage tanks capacity 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed by Engineer in charge
S&F 25 mm CPVC ball valves fiitings to cpvc pipe complete all as specified and as directed by Engineer in charge
S&F Ball brass valve high pressure of polyethylene float and fly nut complete screwed for iron pipe and fixed, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule etc and fixed of 25mm bore complete all as specified and as directed by Engineer in charge
S&F Wash basins including brackets, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand including 32 mm waste pipe complete all as specified and as directed by Engineer in charge
S & F 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer in charge
S&F PVC in repairs (SWR) floor trap diameter of out let 110 mm ,plain with grating including jointing with solvent cement fixed in cement concrete complete all as specified and as directed by Engineer in charge,(cement concrete shall be measured and paid seperately.
S & F in repair Bib Taps with flange, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge
S&F in repairs stop valves cast copper alloy chromium plated with long shank and cup fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore,including necessary cutting and making good wall or floor tiling to match complete all as specified and as directed by Engineer in charge
S & F in repair Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and as directed by Engineer in charge
S&F in repair brass chromium plated telescopic Hand shower(Health Faucet) (ABS Body) with 1 Meter long Easy Flex Tube in Chrome Finish& wall Hook complete all as specified and as directed by Engineer in charge
S&F in repair brass chromium plated shower rose with 150mm long CP shower arm 125 mm size revolving type suitable for 15 mm bore pipes complete all as specified and as directed by Engineer in charge
S & F in repair Soap Dish,brass chromium plated of approximate size 160 x 160 x 90 mm with screws complete all as specified and as directed by Engineer in charge
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer in charge
S&F in repairs Vitreous China wash down watercloset pan (pedestal pattern), white including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer in charge
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed by Engineer in charge
S&F in repairs PVC flexible connection with PTMT nuts, of 15mm dia and 600mm long with brass unions and rubber washers on either side, for connecting water supply line to WHB, flushtank ,Geyser etc complete all as specified and as directed by Engineer in charge
S&F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and as directed by Engineer in charge
Demolition and breaking up drain pipes of size 75/100 mm dia (Salt glazed ware, AC or Reinforced concrete, PVC (SWR)) set in cement mortar complete all as specified and as directed by Engineer in charge
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by Engineer in charge
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed by Engineer in charge
M &L for Stack clamps for 100 mm dia bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts andsecuring ends of stays to wall or roof complete all as specified and as directed by Engineer in charge
S&F PVC (SWR) bends with access door 110mm dia complete all as specified and as directed by Engineer in charge
S&F 110mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed by Engineer in charge
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed by Engineer in charge
M & L for Chequered cement concrete tiles 30cm x 30cm x 25 mm thick, set, jointed and pointed in near cement slurry in floors With grey cement and pigments and including screed bed 20mm thick CM 1:4 complete all as specified and as directed by Engineer in charge
Demolition of Reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed by Engineer in charge
M&L RCC M-30 for column ,pillars,posts,struts,piers,columns and stanchions etc including necessary fomrwork complete all as specified and as directed by Engineer in charge
M&L RCC M-30 as in beam , lintel , lintel band of any size and shape roof beam etc including necessary formwork complete all as specified and as directed by Engineer in charge
M&L RCC M-30 as in chajjas and similar items etc including necessary fomrwork complete all as specified and as directed by Engineer in charge
M & L for TMT (CRS) Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engineer in charge
M & L for TMT (CRS) Mild steel bars 5mm dia and over up to and including 10 mm dia in stirrups,spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engineer in charge
M&L for Plain cement concrete type C1, 1:3:6 Nominal mix (20 mm graded stone aggregate) in roof kerbs or mud stops ,slightly rounded or chamfered angles including formwork complete all as specified and directed by Engineer in charge.
Taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etccomplete all as specified and directed by Engineer in charge.
Taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and directed by Engineer in charge.
Taking down unserviceable main switches, DBs and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and directed by Engineer in charge.
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit heavy duty/PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting complete all as specified and directed by Engineer in charge. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
One light point controlled by one one way switch complete all as specified and directed by Engineer in charge.
One ceiling fan/exhaust fan point controlled by one switch complete all as specified and directed by Engineer in charge.
One 3 pin socket outlet 5 Amps independent complete all as specified and directed by Engineer in charge.
One 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and directed by Engineer in charge.
All as per item No 122.00 above but cable with 4.0 sqmm for socket outlet 15 amps independent complete all as specified and directed by Engineer in charge.
S&F Submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable four runs of 10 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/ceiling and one run of 10 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and directed by Engineer in charge. Note : (i) Four run of single core cable with one run of earth continuity conductor and PVC conduit and PVC conduit accessories will be measured as one length.
S&F Submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two runs of 6 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/ceiling and one run of 6 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and directed by Engineer in charge. Note : (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and PVC conduit accessories will be measured as one length.
All as per item No 129.00 above but with 1.5 sqmm cable complete all as specified and directed by Engineer in charge.
S&F Switch piano, flush type single pole, one way 5 Amps complete all as specified and directed by Engineer in charge.
S&F Socket outlet 3 pin, 6A, flush type complete all as specified and directed by Engineer in charge.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and as directed.
S&F Ceiling rose, 3 terminal polycarbonate isolated body complete all as specified and as directed.
S&F in repair LED lights fitting 1x 20W, 2000lm, CDL, surge protection of 2 KV, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer in charge.
S&F in repair LED 18W inverter batten type fitting 4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer in charge.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 1000lm, CDL, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in charge.
S&F in repair LED Lamp 230 volts,50 Hz,inverter LED 12 watt ,lumen 1200 lm, Charging time 8 to 10 Hours, backup time 04 Hrs, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specified and directed by Engineer in charge.
S&F in repair Bed side light LED 3 Watt, 75 lm, metal body complete all as specified and directed by Engineer in charge.
S&F in repair LED bldg security light fitting 25 watt not less than 2500lm, 230V AC outdoor type, pressure die cast housing with epoxy powder coated, dark graphite grey colour finish, poly carbonate cover with individual LED lenses with IP 65 protection with 5 KV SPD including complete all as specified and directed by Engineer in charge.
S&F in repair LED flood light 70 W not less than 7700 lm made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP65 protection complete all as specified and as directed. Note for item Nos 135 to 141 : (i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F in repair lamp holder batten type polycarbonate body with back plate for batten fitting complete all as specified and directed by Engineer in charge.
S&F exhaust fan made of steel body complete with louvers, voltage 230V, 50 HZ, RPM 1200, Copper winding of sweep 300mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including taking down old unserviceable exhaust fan and deposited to MES store yard complete all as specified and directed by Engineer in charge.
S&F Ceiling fan 1400mm sweep with blades, suitable BLDC remote electronic regulator as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) of wattage < 28W including provision of cable from ceiling rose/connector to fan including taking down old unserviceable ceiling fan and deposited to MES store yard complete all as specified and directed by Engineer in charge.
S&F in repair wall mounted fan 400mm sweep with blades, mounting accessories kit, blade guard set, guard ring, AC 230V complete all as specified and directed by Engineer in charge.
S&F in repair electric water heater, storage type, copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece including stainless steel hose pipe complete all as specified and directed by Engineer in charge.
S&F in repair GI bracket, light grade 25 mm dia and 50 cm long including two numbers GI clamp fixed on wall with necessary fixing arrangement complete all as specified and directed by Engineer in charge.
S&F in repair Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phos phatised, powder painted with copper bus bar 250A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 63 Amps as incomer and MCB Single Pole as outgoing complete all as specified and directed by Engineer in charge.
Supply & fixing in replacement sheet metal enclosure with TPN MCB DB's 4 way (grouted in walls) double door type IP-54, IK-09 Protection. Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed by Engineer in charge.
Supply & fixing in repair MCB DB's SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 200 amps rated copper busbar including suitable size of copper lugs for fixing of cable complete all as specified and directed by Engineer in charge.
Supply & fixing MCB DB's SPN 4 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 200 amps rated copper busbar including suitable size of copper lugs for fixing of cable complete all as specified and directed by Engineer in charge. Note for item Nos 149 to 152 : (i) The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate. (ii) MCCB and MCB will be measured and paid separately.
Supply and fixing MCCB 4 pole, thermal adjustable type, 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA ICS = 100% ICU, complete all as specified and directed by Engineer in charge.
Supply and fixing MCB TPN 63 Amps ,10 KA, C Curve, 415 Volts ,50 HZ complete all as specified and directed by Engineer in charge.
Supply and fixing MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and directed by Engineer in charge.
Supply and fixing MCB SP 6-32 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and directed by Engineer in charge.
Supply and fixing PVC insulated, sheathed two core aluminium conductor 10 sqmm complete all as specified and directed by Engineer in charge.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx 60cmx 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth strip 32 x 6 mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked) of size 40mm dia for protection of GI earth strip upto test point, 20mm dia GI medium grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6 mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :- Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
MAJUMDAR FURNITURE
Nirman Construction Company
M/s K Moorthi
M/s Saina Enterprises
DEEPAK AGENCIES
M/s Ramesh Lal
ANITA VARMA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .