Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹56.8 LAccepted-AOC | 1 | Accepted-AOC L1 |
Tender Value
₹55.0 L
EMD Value
₹1.1 L
Closing Date
4 Jul 2022, 12:00 pmClosed
Xen.
Hafed, Sector - 5, Panchkula
E-TENDER FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 1000 KVA TRANSFORMER BY REPLACING OLD 500 KVA TRANSFORMER INCLUDING INSTALLATION OF NEW VACUUM CIRCUIT BREAKER (VCB), POWER CONTROL CENTRE (PCC) PANEL AT GURUGRAM
2022_HBC_227053_1
Supply, Installation of 1000KVA Transformer at Grg
Open Tender
Civil Works
Tender
1 days
Gurugram
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹1.1 L
8 Sept 2022
24 Jun 2022
4 Jul 2022
24 Jun 2022
4 Jul 2022
24 Jun 2022
Amount
NS Items
Supply and installation of Phase Indicating Lamp LED Type, Red - 220Vac,22 mm Round Plastic/High Glow SMD.220 VAC, IP50 Make: Schneider / Siemens / Legrand or equivalent (approved by Engineer-in-charge)
Supply and installation of Phase Indicating Lamp LED Type, Yellow - 220Vac,22 mm Round Plastic/High Glow SMD.220 VAC, IP50 Make: Schneider / Siemens / Legrand or equivalent (approved by Engineer-in-charge)
Supply and installation of Phase Indicating Lamp LED Type, Blue - 220Vac,22 mm Round Plastic/High Glow SMD.220 VAC, IP50 Make: Schneider / Siemens / Legrand or equivalent (approved by Engineer-in-charge)
Supply and installation of ACB/MCCB `On' Status Indicating Lamp LED Type, Red - 220Vac,22 mm Round Plastic/High Glow SMD.220 VAC, IP50 Make: Schneider / Siemens / Legrand or equivalent (approved by Engineer-in-charge)
Supply and installation of ACB/MCCB `Off' Status Indicating Lamp LED Type, Green - 220Vac,22 mm Round Plastic/High Glow SMD.220 VAC, IP50 Make: Schneider / Siemens / Legrand or equivalent (approved by Engineer-in-charge)
Supply and installation of ACB/MCCB `Trip' Status Indicating Lamp LED Type, Amber - 220Vac,22 mm Round Plastic/High Glow SMD.220 VAC, IP50 Make: Schneider / Siemens / Legrand or equivalent (approved by Engineer-in-charge)
Supply and installation of Digital Multifunction Meter with Rs. 485 communication port, 3Ph 4wire System 415Vac, CL-1.0, with V, A, F, PF, KW, KWH with 3Row Display with Analog Bargraph. CTR-/5A, 96x96mm, Aux. Supply -220Vac, Make: Schneider / Siemens / Secure or equivalent (approved by Engineer-in-charge)
Supply and installation of neutral link Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of metering CTs 2000/5A, Class-1 15VA Make: Elmex / Matrix / AE / Nippen or equivalent (approved by Engineer-in-charge)
Supply and installation of metering CT 600/5A Class-1 5VA Make: Elmex / Matrix / AE / Nippen or equivalent (approved by Engineer-in-charge)
Supply and installation of metering CT 400/5A Class-1 5VA Make: Elmex / Matrix / AE / Nippen or equivalent (approved by Engineer-in-charge)
Supply and installation of metering CT 250/5A Class-1 5VA Make: Elmex / Matrix / AE / Nippen or equivalent (approved by Engineer-in-charge)
Supply and installation of metering CT 100/5A Class-1 5VA Make: Elmex / Matrix / AE / Nippen or equivalent (approved by Engineer-in-charge)
Supply and installation of CT shorting links Make: Connectwell / Elmex / Matrix / AE or equivalent (approved by Engineer-in-charge)
Supply and installation of 400 A, 4P Changeover Switch. Make: Havells / Nippen / HPL or equivalent (approved by Engineer-in-charge)
Supply and installation of Spreader links for 800Amp MCCB Make: Schneider / Siemens / L&T / ABB or equivalent (approved by Engineer-in-charge)
Supply and installation of Spreader links for 630Amp MCCB Make: Schneider/ Siemens / L&T / ABB or equivalent (approved by Engineer-in-charge)
Supply and installation of Spreader links for 400Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Spreader links for 250Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Spreader links for 100Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Extended Rotary Handle for 800 Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Extended Rotary Handle for 630 Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Extended Rotary Handle for 400 Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Extended Rotary Handle for 250 Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of Extended Rotary Handle for 100 Amp MCCB. Make: Schneider / Siemens / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of APFC relay 14 step. Make: EPCOS / Nippen / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor 5 KVAR normal duty. Make: Schneider ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor 10 KVAR normal duty. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor 25 KVAR normal duty. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor 50 KVAR normal duty. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor duty contactor 5 KVAR. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor duty contactor 10 KVAR. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor duty contactor 25 KVAR. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply and installation of capacitor duty contactor 50 KVAR. Make: Schneider / ABB / L&T or equivalent (approved by Engineer-in-charge)
Supply, fixing and installation of Push Button for ON / OFF/Momentary action: 5,000,000 operations min. Alternate action: 500,000 operations min./500,000 operations min. (250 VAC, 3 A, with an inductive load having power factor cos θ = 0.4). Ambient operating temperature *1 -25 to 70°C. Make: Schneider / Siemens / ABB or equivalent (approved by Engineer-in-charge)
Supply and installation of Bus Bar of Electrolytic Aluminium of E91 grade of size: Main Busbars:100X12X2 Neutral Busbars: 100X12X1. Earthing Busbar: 50X10X1 Make: Hindalco / Balco / Jindal or equivalent (approved by Engineer-in-charge)
Supply and installation of Bus Bar of Electrolytic Aluminium of E91 grade of size: Main Busbars:80X10X1 Neutral Busbars: 80X6X1. Earthing Busbar: 40X10X1 Make: Hindalco / Balco / Jindal or equivalent (approved by Engineer-in-charge) Make: Hindalco / Balco / Jindal or equivalent (approved by Engineer-in-charge)
Design, supply, fixing and installation of CRCA sheet steel enclosure. Panel will be fabricated with 16SWG CRCA sheet steel for load bearing surfaces and 16SWG for non load bearing surfaces. H X L X D(2075 X 3500 X 1000) Make: Tata / Jindal / Sail or equivalent (approved by Engineer-in-charge)
Design, supply, fixing and installation of CRCA sheet steel enclosure. Panel will be fabricated with 16SWG CRCA sheet steel for load bearing surfaces and 16SWG for non load bearing surfaces. H X L X D(1375 X 2500 X 1000). Make: Tata / Jindal / Sail or equivalent (approved by Engineer-in-charge)
Wiring for all panels (Harness for starter & metering, Thimbles, Ferrules, Sleeves, PVC channel, Gourmets, Braided wire for earthing etc). Note: This work will be executed as per the requirement of site and the entire satisfaction of Engineer-in-Charge.
Hardware for all panels (Fitter, Nuts, Bolts, Spring washers, Door hinges, Door Locks & Key, Lifting hocks, Base channel, C-type Channels, Finger type Insulators & Support etc) Note: This work will be executed as per the requirement of site and the entire satisfaction of Engineer-in-Charge.
Accessories for all panels (Danger plate, Feeder detail Inscription plates, Acrylic/Bakelite/Perforated sheet cover for busbar, Door gasket etc) Make: Metal Craft / Samrita / Click for sign or equivalent (approved by Engineer-in-charge) Note: This work will be executed as per the requirement of site and the entire satisfaction of Engineer-in-Charge.
Manufacturing Cost for all panels (Labour + Overheads) (Fitting of Busbar, Panel enclosure, Circuit breaker / SFU / Feeder, Starter / Metering wiring etc) Note: This work will be executed as per the requirement of site and the entire satisfaction of Engineer-in-Charge.
Supply, installation, testing and commissioning of VCB 1000A with VCB panel & Single incomer and single out going with CT suitable for 1000KVA Transformer. Make: Schneider / ABB / Areva or equivalent (approved by Engineer-in-charge)
Supply, installation and erection of Maintenance free safe earthing electrode G.I. Pipe 3 meter long , 80mm dia (outer) duly galvanized 80-100 micron & CPRI tested 51.69 peak(KA) 21.4 RMS(KA) for 1 sec. complete in all respect. Make: Super / British Stander / Phoenix or equivalent (approved by Engineer-in-charge)
Supply, installation and erection of Maintenance free safe earthing electrode C.U. Pipe 3 meter long , 76mm dia (outer) duly galvanized 80-100 micron & CPRI tested 51.69 peak(KA) 21.4 RMS(KA) for 1 sec. complete in all respect. Make: Super / British Stander / Phoenix or equivalent (approved by Engineer-in-charge)
Supply, installation & laying of hot dipped GI / earthing strip/wire laid in ground/along wall/in trench support including termination.40x6mm CU strip Make: Super / British Stander / Phoenix or equivalent (approved by Engineer-in-charge)
Supply, installation & laying of hot dipped GI / earthing strip/wire laid in ground/along wall/in trench support including termination. 50x6mm CU strip Make: Super / British Stander / Phoenix or equivalent (approved by Engineer-in-charge)
Supply, installation and laying of LT cables in excavated trenches, concrete trenches, along walls, through hume pipes, cable trays etc. with testing and commissioning includes fixing of clamps/saddles hardware for dressing of cable. The job to be done as per directions of Engineer-in-charge. 16 Core 1.5 sq mm copper Control Armoured Cable. Make: Havells / KEI / POLYCAB or equivalent (approved by Engineer-in-charge)
Supply, installation and laying of LT cables in excavated trenches, concrete trenches, along walls, through hume pipes, cable trays etc. with testing and commissioning includes fixing of clamps/saddles hardware for dressing of cable. The job to be done as per directions of Engineer-in-charge. 10sqmm 4 Core unarmourd Copper cable. Make: Havells / KEI / POLYCAB or equivalent (approved by Engineer-in-charge)
Supply, installation and laying of LT cables in excavated trenches, concrete trenches, along walls, through hume pipes, cable trays etc. with testing and commissioning includes fixing of clamps/saddles hardware for dressing of cable. The job to be done as per directions of Engineer-in-charge.3.5 core 240 sq mm AL.Armourd cable. Make: Havells / KEI / POLYCAB or equivalent (approved by Engineer-in-charge)
Supply, installation and laying of LT cables in excavated trenches, concrete trenches, along walls, through hume pipes, cable trays etc. with testing and commissioning includes fixing of clamps/saddles hardware for dressing of cable. The job to be done as per directions of Engineer-in-charge. 3 core 185 sq mm AL.Armourd cable. Make: Havells / KEI / POLYCAB or equivalent (approved by Engineer-in-charge)
Supply and fixing of 185 sq mm outdoor Cable termination Kit Make: Dowell / Comex / comet or equivalent (approved by Engineer-in-charge)
Supply and fixing of 185 sq mm indoor Cable termination Kit Make: Dowell / Comex / comet or equivalent (approved by Engineer-in-charge)
Supply and termination of Single compression Gland with lugs tape nut bolt etc as instruction by Engineer-in-charge Make: Molex / MCI / Generic or equivalent (approved by Engineer-in-charge)
Recovery items : Buy back of old Transformer 500 KVA including all charges like loading, unloading, transportation, labour etc without damaging the old foundation and structure
Recovery items : Buy back of old VCB including all charges like loading, unloading, transportation, labour etc without damaging the old foundation and structure
Recovery items : Buy back of all old panels including all charges like loading, unloading, transportation, labour etc without damaging the old foundation and structure
Bidder Name
Amount
Lambnet Enginering Private Limited(GSTN-07AACCL7559E1ZD)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .