| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹41.0 L+₹7,014 (0.17%)Rejected-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L2 | Rejected-AOC 2ND LOWEST BIDDER | |
| 3 | L3₹42.4 L+₹1.5 L (3.69%)Rejected-AOC VILLAGE CHANNI POST OFFICE SATTANI DISTT UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC 3RD LOWEST BIDDER | |
| 4 | L4₹42.6 L+₹1.7 L (4.14%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L4 | Rejected-AOC 4TH LOWEST BIDDER |
Tender Value
₹47.6 L
EMD Value
₹95,200
Closing Date
3 Nov 2022, 6:00 pmClosed
GE (ARMY) DHAR ROAD
GE (ARMY) DHAR ROAD Udhampur PIN 182101
SPL REPAIR TO BLDG NO P-69 (COOK HOUSE) OF 326 LT AD REGT(COMP) AND PROVISION OF SHED NEAR ENTRANCE GATE MAIN GATE OF 16 CORPS ZONE WKSP AND PROVN OF SENTRY POST WITH ALLIED INFRA AT 960 LT AD REGT WKSP AND PROVN OF LIGHTENING PROTECTOR WITH COPPER E
2022_MES_541307_3
8068/NIT-32/2022-23
Open Tender
Civil Works
Item Rate
240 days
DHAR ROAD UDHAMPUR
As per tender Documents
6 documents required · 6 mandatory
₹500
GE (ARMY) DHAR ROAD
₹95,200
Yes
15 Feb 2023
13 Oct 2022
5 Nov 2022
13 Oct 2022
3 Nov 2022
20 Oct 2022
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each complete.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing and as directed by Engineer-in-Charge .
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frames shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom raid on either side and as gap insert for top rail on either side andas gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rials with suitable PVC sheet beading, and joined together with solvent cewment, suppling and fixing in the frame at site as per specification and drawing as directed by Engineer-inCharge.
Pressed steel frames of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified.
Pressed steel frames of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs hinges, locks strike plate etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified.
PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) for filling in back of pressed steel door frame/chowkhat and fixing of bed block of hold fast etc complete all as specified and as directed.
35 mm thick 2nd class hard wood factory Made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat all as specified and directed
2nd class HW 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels commercial type on both side complete all as specified and as directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and fixed complete all as specified.
Aluminium anodised 100 mm long Butt hinges type B-21 with galvanised mild steel screws complete
125 mm long Aluminium anodised barrel tower bolts, etc.complete all as specified.
125 mm long cast type Aluminium anodised handles etc.complete all as specified.
100mm size butt hinges, medium weight, cold rolled mild steel, and fixed with galvanised mild steel screws complete.
Aluminium anodised barrel tower bolts, 150 mm long of extruded section complete all as specified and directed.
Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed.
300 mm long aluminuim alloy, anodised , sliding bolt with hasp staole (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
100mm long door stopper of aluminium alloy body and tongue,anodised fixed to door complete all as specified.
300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate fixing wooden chowkhat/steel door frame complete all as specified
18 mm thick water proof solid Medium Density Fibre (MDF) board prelaminated both side(Approved colour) for Door/ Cupboard shutters/ shelves and partition of required size fabricated by jointing and fitted with necessary arrangement as in cupboard shutter/ backside/partition/shelves etc fixed with each other using solvent cement adhesive and stainless steel screws. the visible edge of board/ shutter shall be lipped with 18mm wide and 1mm thick edges leaping tapes as per manufacturer instructions, complete all as specified and directed.
100 mm long aluminium anodised hasp and staple safety tape including bolts to hinge plate and fixed with screws complete all as specified and as directed.
Continuous (piano) hinges 30mm width of flap, mild steel bright finish or electrogalvanised of complete all as specified.
Aluminium anodised handles, cast type anodised 100 mm long complete all as specified and directed.
Steel windows made up of box steel section of 16 gauge ms sheet ub outer frame, shutter farame and centre frame with outer side glazed shutter and inner side wire gauged shutter fixed as shwon in drg consisting with two nos pintol hinges 75mm long, two Nos stove enemaled tower bolts 150 mm long and one No steel handle, deovitailed or welded each panels complete with necessary cleats and stopers all as specified as directed.
Steel ventilator made up of box steel section of 16 gauge MS Sheet frame, fixed type suitable to fix half portion wire cloth and half portion glass with suitable MS beading or flat or oil putty complete.
Sheet glass ordinary quality 3.00 mm thick n.exc 0.50 sqm each for fixing with all necessary fixing arrangement all as specifieid and as directed.
Mild steel framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified.
Two coat of synthetic enamel paint over a coat of pink primer on new wooden surfaces incl preparation.
Preparation of new steel surfaces of any description over 10cm width or girth and applying two coasts of synthetic enamel paint over a coat of red oxide (for steel surfaces) complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing removing serviceable tiles to store and rubbish off thepremises etc complete all as specified.
Glazed ceramic coloured tiles in vertical surfaces 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade incl screeding 10mm thick in CM 1:3 etc complete all as specified.
Non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm. in floors over 15 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes etc complete all as specified.
Non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm. in floors over 15 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes etc complete all as specified.
Coloured Virified Ceramic tiles 10 mm thick (square/ ectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes etc complete all as specified.
Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed With grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over complete over 20 mm thick screed bed or bedding layer of mortar 1:6 for laying floor finishes etc complete all as specified..
Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 10 mm thick 1:3 cement mortar all as specified
For 50 mm thick in Plain cement concrete type C2 ( 1:3:6)( using 20 mm graded aggregate ) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as directed at site.
Taking down existing roof treatment of any description and any type all as specified and directed by Engr-in-Charge
15 mm thick cement plaster in cement mortar 1:4 on roof surfaces over Brushing neat cement slurry with 3.0kg of cement per sq. metre finished surfaces even and smooth without using extra cement, incl water proofing compound all as specified.
Supply only liquid water proofing compound
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc
Rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement and with using integral water proofing compound
Rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:6 finished even and smooth withot using extra cement complete all as specified.
Applying three coat of white wash including prepration of newly plastered surfaces of wall etc complete all as specified.
Apply two coat of colour wash on newly plastered surface of walls including preparation.
Apply two coat of cement base paint over a coat of alkali resistant primer on new plaster surface of walls including preparation.
Complete removal of existing treatment on wall, by scraping, sand papering or by using mechanical sander and preparing plastered surfaces and applying two coats of oil emulsion distemper of approved tint over one coat of wall care putty 1mm thickprepare the surface even and smooth on walls by using roller/spray complete all as specified and as directed by Engr-in-Charge.
Apply two coat of colour wash on old decorated surface of walls including preparation.
Preparing old decorated wall surfaces applying two coats of white wash on wall complete all as specified.
Complete removal of existing treatment on external wall by scraping, sand papering or by using mechanical sander apply two coat of cement base paint over a coat of alkali resistant priming all as specified and as directed by Engr-in-Charge.
One coat of synthetic enamel paint over old painted steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified.
Applying one coats of synthetic enamel on old painted wood and wood based surfaces of any description, over 10cm width or girth, not other wise described including preparation/scraping of old painted surfaces
Demolition stone slabs and tiles of any description or thickness in floors, apron etc laid bedded and pointed in any mortar
20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. over 15mm thick screed bed etc. also using adhesive for fixing in vertical all as specified
Fix in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe incl sink coupling, 40mm waste fitting, overall size915mmx460mm with bowl size 410 mm x 330mm x 160mm, etc complete all as specified and as directed.
Fix in repair 15 mm dia bore fancy type chromium plated bib taps with wall flange cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.
Fix in repair 15 mm bore chromium plated Angular stop valve of cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or for unions and fixed all as specified and directed
Pillar taps cast copper alloy fency type long neck with capston heads chromium plated screwed down high presure, with or without lettered 'Hot and cold' with long screwe shank and fly nuts, fo iron pipe and fixed for 15mm bore
Fix in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges. complete all as specified.
Fix in repair brass chromium plated shower rose 200 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and as directed.
Fix in repair PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality suitable for hot and cold supply complete all as specified.
Fix in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor.
Fix in repair (Plastic Polymer Cistern) valve less, with top button double action type flushing cistern of capacity 10 ltrs , low level white inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type incl provision of 32mm PVC flush pipe of required length and making connections complete incl taking down old one by dismantling the existing unserviceable cistern of any description.
Fix in repair wash hand basin of size 515 x 410 mm vitrous China white flat back including brackets, waste coupling & PVC waste pipe of 32 mm dia etc. complete all as specified and directed.
Fix in repair PVC (SWR) floor trap with grating including jointing with solvent cement, 75mm diameter of outlet, all as specified.
PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips complete all as specified.
PVC (SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clips complete all as specified.
Dismantling of cast iron or PVC pipes including all fittings and accessories, 100/75 mm dia and in any position all as specified.
PVC (SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, laid in trenches or in floor complete all as specified.
All as per item No 70 here-in- before above but 110mm bore
PVC(SWR) bends suitable for 110 mm external dia complete all as specified
PVC(SWR) bends suitable for 75 mm external dia complete all as specified
PVC (SWR) junction single, (single T) equal or unequal of 110mm dia
Ditto item No 74 provided with excess door 110mm
Add to item No 74 provided with excess door 75mm
PVC (SWR) vent cowl of 110mm bore
Grating doom 125 mm dia with or without waste hole of PTMT. (Minimum weight 40gms)
Dismantling water tank and remove to Store of capacity exc 250 but not exc 500
1000 ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed.
20mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed.
25mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms)
PVC nipple 20mmsuitable for HDPE water tank min wt for 15mm-38gm/20mm-45gm
Tank nipple 25mmsuitable for HDPE water tank min wt for 15mm-38gm/20mm-45gm
Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store.
GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified.
Refixing 15 mm dia ,old steel tubuing and connections in new or old possition (wall,ceiling and floors etc)
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store.
GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified.
Refixing 20 mm dia ,old steel tubuing and connections in new or old possition (wall,ceiling and floors etc)
GI tubing 25 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
25mm dia fancy type PVC coated on MS Pipe coloured curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories complete all as specified and directed. Note : The cost of brackets and knobs is deemed to be including in the quoted rate.
Expanded metal exc 4 Kg cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia all fixing with galvanised steel stapple fixed to steel or wood members laid in any position incl closing after filling.
Welding in repair n.exc 2.5 cm in length to metal of any thickness to be welded all as specified and as directed.
Providing cement concrete type 1:2:4 type B-0(12.5 mm graded agg ) as in roof kerbs or mud stops, filling of hold fasts and door frames, rounded or chamfered on edges complete all as specified.
False ceiling with Gypsum based ceiling tiles and frame work (with aluminum foil on one side) of size 595 x 595 mm of thickness not less than 9 mm including with GI powder coated frame angle /tee grid frame work for ceiling with following specfication (a) S&F Angle of side 25x25x1mm powder coated (b) 25x25x1 mm GI powder coated at Bottom tee as in main member (c) 25x25x1 mm thick GI powder coated at bottom tee as ibn cross members (d) S&F 1.6mm dia GI wire suspenders alongwith adjustable clamps to maintains leveling inculding fixing to ceiling fasteners manufacturers instructions complete.
Fix in repair false ceiling with Gypsum based ceiling tiles (with aluminum foil on one side) of size 595 x 595 mm of thickness not less than 9 mm as per manufacturers instructions incl taking out old tiles replace with new complete. MAKE: VINYL TOUCH of LaGyp (LAFARGE) or equivalent in GYPROC (SAINT GOBBAIN).
Dismantling of plain, corrugated or semi corrugated sheeting, of any description, roof coverings all as specified.
Painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified as directed.
Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified as directed.
Post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron
Post construction ATT Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors
Vitreous china wash basin, counter top oval type white, size 570x450mm including all fittings brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified.
Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:6 complete all as specified.
Magnetic catcher suitable for kitchen cabinet shutter complete all as specified and directed
Demolition of cement concrete ground floor paving or in any position n exc 15 cm thickness (below or above ground level) .
Broken stone Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
100mm thick PCC 1:4:8 type D2 (40mm graded aggregate) for floor sub base layed in alternate bays.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade made in rubber moulds/rubrised type with scratch proof lacquer coating on top surface with gray cement and pigment.
Sand filling under floors or in foundations including watering and consolidation
Pre polished chemically treated rubber moulded Chequered cement concrete coloured tiles of size 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors With white cement & pigment incl 20mm thick cement screed CM 1:6.
Pre cast cement concrete blocks factory made type C1, 1:3:6 (20mm graded aggregate) with solid blocks and setting with cm 1:6 as in kerb stones, or mud stops rounded or chamfered on edges complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150mm dia
150mm internal dia of salt glazed stoneware pipes grade 'A' incl testing and laid in trenches to a level on concrete bed complete all as specified.
Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested including demolition of old bed and pipes omplete all as specified and as directed. (thickness of concrete bed 100mm).
Brick work built in cement and sand mortar 1:6 with sub class 'B' old size bricks straight or curved on plan exceeding 6m means radius including wall for crumple joint complete all as specified and directed by Engr -in-Charge.
Rendering 15mmthick in CM 1:4 on block masonry surfaces finished even and smooth without using extra cement complete all as specified.
Cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes omplete all as specified and as directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation of manholes omplete all as specified and as directed.
PCC 1:2:4 type B1 using 20mm graded aggregates as in surfaces channels and drains complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc omplete all as specified and as directed.
Precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr -in-Charge..
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr -in-Charge..
All as per item No 129 here -in- before but 5mm dia and over upto and including 10mm dia in in stirrups, spacers and binders .
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes omplete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in any type of soil omplete all as specified and as directed.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil omplete all as specified and as directed.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as specified and as directed.
Salt glazed stoneware gully traps of size 150 x 150 mm, square or rounded mouthed, type `P' fixed in CM 1:6 and cover with RCC cover slab of size 200 X 200 X 50mm incl necessary exc, pcc etc.
Surface dressing n exc 15 cm deep in soft/loose soil
Reinforced cement concrete M-25 using 20mm graded aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
All as per item No 137 above but in columns
All as per item No 137 above but in beams, cantilevers, bressummers, lintels over 1.5m span
All as per item No 137 above but in Slabs supported on walls ,beams and coiumns in floors,roofs, landings ,balxonies,conopies, deck slabs and in shelves & the like
Form work to sides of rough finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Form work to sides of rough finished square, rectaungular or polygonal surfaces of of pillars, posts, struts, piers, columns and stanchions.
Formwork to sides and soffit of rough finished flat surfaces of soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
Form work to rough finished flat surfaces of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Supply only integral water proofing compound,
Rendering 10mm thick in CM 1:3 in Ceilings finished even and smooth without using extra cement.
75mm thick Cement conrete type C2, 1:3:6 using 40mm graded stone aggregates for plinth protection laid in alternate panels and finish even and smooth without using extra cement all as specified and directed.
Filling under floors or in foundations with approved soil including spreading, levellig in layers n exc 25cm thick and well ramming, watering as reqd complete all as specified and directed.
75mm thick Cement conrete type D2, 1:4:8 using 40mm graded stone aggregates as in sub-base, sub-floors, floors etc complete all as specified and directed..
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) land on primed surface by torch application with end lap 100mm and mid 75mm complete all as specified and directed.
Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces
Annodised aluminium partition wall with aluminium frame size 100x44x1.48mm thick partition duly fitted with peosprane rubber beading , glass panes 5.5 mm nominal thickness or 12mm thick prelaminated melamine faced both side decorative exterior grade type II particle board panels complete all as specified and directed all as specified.
Mild steel Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections including all lattice bars, gusset plates, nuts & bolt incl necessary fittings etc of Fe 290 grade E-165 complete all as specified and directed.
Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 290 grade E-165 complete all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 290 grade E-165 complete all as specified and directed.
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work onforming to Fe-290 Gde E-165 complete all as specified and directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power ) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc, removing materials to store, or keeping in safe custody for offering credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Material and labour for Point wiring complete (for simple and modular type ) with 2 run of 1.5 sqmm single core PVC insulated heavy duty ISI Marked,FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC non metalic PVC conduit heavy duty medium grade ISI marked not less than 20mm dia with all accessories like tee, straight joint, L Bend etc.,concealed on walls, sufrace on ceiling/ floors etc., and including provision of PVC heavy duty Insulated FRLS copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal sunken box flushed inside the walls, with 3mm thick laminated sheet cover for housing the switches, socket outlets, fan regulators etc., for the following:-
(a) One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
(b) One switch socket outlet point 3 pin 5 Amps on Independent board.
Material and labour for Point wiring complete with 2 run of 2.5 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including suitable size of PVC non metalic conduit with all accessories like tee, straight joint, L Bend etc., concealed on wall surface on ceiling / roofs etc., and including provision of PVC insulated heavy duty medium grade ISI Marked unsheathed copper conductor 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches/socket outlets 15 Amps.
Material and labour as in repair for sub main wiring with two single core PVC insulated unsheathed copper conductor cable 6 sqmm FRLS drawing in and including rigid non metalic PVC conduit medium grade ISI marked heavy duty 25 mm dia conduit concealed on wall/surface on ceiling with one additional PVC wire of copper conductor of 4 sqmm for earth continuity conductor FRLS incl taking down old Unsv submain any type and size and making good the disturbed surface complete all as specified and directed by EIC.
Material and labour for sub main wiring with two single core PVC insulated unsheathed copper conductor cable 4 sqmm drawing in and including rigid non metalic PVC conduit medium gradeISI marked concealed on wall/surface on ceiling with one additional PVC wire of copper conductor of 4 sqmm for earth continuity conductor FRLS including taking down old UNSV and making good the disturbed surface complete all as specified and directed by EIC.
S&F as in bracket holder/ Angle lamp holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge.
S&F as in bulk head light fittings 10 Watt for wall all as approved and directed by Engineer-in-charge.
Supply only LED 9 Watt lamp , 240 Volt, 50 Hz lamp
S/F Bell Push flush type 6 Amp 240 Volt AC all as specified and directed..
S/F Call Bell AC 230 V Single Pole along with necessary electric connection all as spd and directed.
Supply and Fixing LED 20 Watt light fitting Batten integrated LED channel, integral sleek extruded polycarbonate LED Channel with white acrylic cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with all accessories including taking down old UNSV all as specified and directed by Engr-in-Charge.
Supply and fix LED mirror wall light/Mirror light fitting 10 watt , 230 volt, 50 Hz complete with LED light all as spd and dir by EIC.
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down old UNSV complete.
Supply and fixing Exhaust fan AC single phase 230 volts for size 300 mm sweep, including making hole and fixing arrangement including nut, bolts, washer etc, making good the disturbed surfaces matched with existing finishes comprising with necessary eletric connection with suitable copper wire from ceiling rose complete incl spd incl taking down old Ex fan any size any type complete by removing its electrical connection and deposit it to E/M MES store or as directed by EIC.
S&F Exhaust fan AC single phase 230 volts for size 450 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC.
Supply & fix Electric Storage water heater of capacity 25 Ltr , 230 V energy efficient and connected with PVC brass ended connection pipe 02 Nos complete all as specified and directed by Engineer-in-charge. Including fast nut, bolt, washe complete and removing and dismentaling of old UNSV electric storage water heater any type and size and deposited it in MES Store yard or as directed by EIC.
Supply & fix Electric Storage water heater of capacity 50 Ltr , 230 V energy efficient and connected with PVC brass ended connection pipe 02 Nos complete all as specified and directed by Engineer-in-charge. Inluding fast nut, bolt, washe complete and removing and dismentaling of old UNSV electric storage water heater any type and size and deposited it in MES Store yard or as directed by EIC.
Supply and fixing Ceiling fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement such as nut, bolts, washer etc, making good the disturbed surfaces matched with existing finishes comprising with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd incl taking down old ceiling fan any size 1200/1400 mm any type complete by removing its electrical connection, dismantling its rod and wings complete and deposit to E/M MES store or as directed by EIC.
Supply and fixing of building security LED fitting upto 40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection incl taking down complete all as directed by EIC
S&F 1.5m long 40mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including suitable 2 Nos. FI clamps as required to fix on concrete / steel poles incl taking old unsve GI bracket any type and size complete all as specified and as directed
S & F ceiling rose Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and directed.
Supply and fix fan speed regulator, electronic step type,120 watt suitable for single phase AC, 240 volts, 50 Hz, all as specified and as directed.
Supply and fixing socket outlet 5 Amp 230 volt ISI Mark complete all as specified and directed
Supply and fixing Switch , single pole, one way 5 Amp 230 Volt ISI Mark complete all as specified and directed
Supply and fixing socket outlet 16 Amp 230 volt ISI Mark complete all as specified and directed
Supply and fixing switch , single pole, one way 16 Amp 230 volt ISI Mark complete all as specified and directed
Supply & Fixing TPN DB 4 Way distribution Box, double door of protection grade IP 42 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar complete confirming to IS 13032 & 8623 incl taking down old UNSV TPN DB any type and size complete all as specified and directed.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 incl taking down old UNSV SPN DB any type and size complete all as specified and directed.
Supply and fixing as in repair Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by EIC.
Supply & Fixing MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB TPN DP 63 Amps 440 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with RCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Supplying ,Laying and testing complete GI tube medium grade 50 mm bore with all fittings laid in trenches complete all as specified and directed.
Supplying ,Laying and testing complete GI tube medium grade 20 mm bore with all fittings laid in trenches complete all as specified and directed.
Supply and Fixing of Gate valve 20 mm bore complete all as specified.
Cutting/making hole into CI/DI/MS pipes of 100 mm carefully and insertion of new tee incl clamping with suitable size clamp for taking small branch connection upto 25 mm bore complete all as directed by EIC.
Taking down old unserviceable GI pipe 50 mm dia
Taking down old unserviceable GI pipe 20 mm dia
Taking down old unserviceable valve 20 mm dia
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
Dismentaling of cable XLPE Insulated cable of size 16 Sqmm 4 Core complete as spd by EIC.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 Core.
Supply and fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, complete all as specified and directed.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and fixing with clamp nut,bolts etc and connect with ceiling rose all as specified and directed
Supply & Fixing MCB SPN, 5 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, unarmoured tape and overall PVC sheathed 6 Sqmm 2 core with required aluminium cable lugs all as specified and directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement air termination single pointed aluminium rod 12mm dia and 300mm long fitted on existing lightening conductor tube 40mm on building with F clamps nut bolts complete all as specified and directed.
S&F in repairs aluminium strip 25x 3.0mm with saddle and fixing screws, gutties etc on wall and roof top conductors including grouting wooden gutties complete all as specified and directed.
S&F in replacement earth test point terminal block made out of gun metal or phosphorus bronze size 75x75x5mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw grouting on wall with PCC, nut bolts and washers, including making good to disturbed surface complete all as specified and directed.
Earthing complete with copper plate electrodes 600x600x6mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised iron earthing strip 20x3mm thick by means of bolt nut check nut and washer of galvanised iron or steel all as specified and shown in electrical plate No3 of MES SSR Part-I 2009 connected to earth test point as specified and testing on completion including provision of 40mm dia light grade pipe upto 7.5 mtr length as protection and watering pipe shall be 20mm bore medium grade including all excavation and earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel all as directed at site.
S&F galvanised iron strip 32x6 mm for extension of eath and connected to equipement or panel complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 in cement concrete in foundation, filling and mass concrete using 40mm graded stone complete all as specified and directed.
S&F tubing light grade 40mm bore fixing in bricks/ stone wall with 2 Nos supporting clamp made of flat iron of size 25x 4 mm including nut bolt and grouting bolt complete all as specified and directed for fixing lightening arrestor on roof top.
MAHADEV ENTERPRISES
PARAS RAM ASGOTRA AND SONS
R K BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .