| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹23.8 L+₹16,075 (0.68%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance L2 | |
| 3 | L3₹26.5 L+₹2.9 L (12.1%)Rejected-Finance CHHANI NANAK TEHSIL MANDAL PHALLAIN JAMMU J K 180003 | JAMMU | JAMMU | J K | 180003 | L3 | Rejected-Finance L3 | |
| 4 | L4₹32.0 L+₹8.4 L (35.8%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹89,940
Closing Date
4 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR MAINT OF CERTAIN INTERNAL AND EXTERNAL ELECTRIC SUPPLY EQUIPMENT AND APPLIANCES OF J-1 AND J-2 LOC UNDER GE (EAST) JALANDHAR CANTT
2021_MES_456504_1
GE/JULL/ET-23/2021-22
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹89,940
Yes
19 Aug 2021
7 Jul 2021
6 Aug 2021
7 Jul 2021
4 Aug 2021
23 Jul 2021
60 days
Amount
Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fitting Supply and fixing fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawl plug, screw etc including removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed
Material and labour for point wiring with 1.5 sqmm (nominal area), 1100 volt grade PVC insulated FRLS type multi stranded copper conductor cable drawn in and including concealed rigid PVC conduit fire proof ISI marked with accessories including cutting chases for laying of conduit/ fixing of boxes in walls/ floors etc including making good to disturbed surfaces as per adjoining specification and terminated in concealed terminal boxes including MS concealed terminal boxes with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with washers and earth continuity PVC insulated FRLS type cable with stranded copper conductor of size 1.5 sqmm (nominal area) green colour as earth wire connected with earth dolly for one light point controlled one switch complete all as specified and as directed.
All as per Srl Item No. 2.00 but one fan point controlled by one switch through regulator.
All as per Srl Item No. 2.00 but for 3 pin 5 Amp socket point controlled by one switch on independent board.
All as per Srl Item No. 2.00 but one socket point controlled by one the same board 3 pin 5 Amp with other switch
All as per Srl Item No. 2.00 but 3 pin 15 Amp socket outlet with 4 sqmm PVC insulated FRLS copper cable and 2.5 sqmm PVC insulated FRLS copper cable for continuous earth continuity conductor all as specified and directed.
Supply and fixing switch modular type, 5 Amps, 240 volt AC single pole, one way including taking down existing switch complete all as specified.
Supply and fixing switch modular type, 15 Amps, 240 volt AC single pole, one way including taking down existing switch complete all as specified.
Supply and fixing socket outlet 5 Amp, 5 pin modular type including taking down existing socket complete all as specified.
Supply and fixing socket outlet multipurpose 3 in 1, 6 pin, 5 & 15 Amps, modular type including taking down existing socket complete all as specified.
Material and labour in replacement of submain wiring with two single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.00 sqmm 1100 volts grade including and 2.50 sqmm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/ steel rigid conduit complete all as specified. Make: Two run of 4.0 sqmm cable and one run of 2.50 sqmm cable as earth continuity conductor shall be measured & paid as one unit
Supply and fixing in repair aesthetically designed linear mirror light 14 watt with provided with high output PMMA diffuser for glare free light, dimension 600mm including taking down old one with all accessories and making good the existing disturb surface complete all as specified and directed.
Supply and fixing in replacement decorative wall light fixture made up of polycarbonate, suitable for lamp type 1x5/7/9 watt retrofit LED lamp including 5/7/9 watt LED lamp (B-22 base) of same make as fitting including removing old fitting complete all as specified
Supply and fixing square surface mounted ACE LED SURFACE DOWNLIGHTER of 16 watt 6500K of size 155mm x 155mm having surface mounting convertible feature including RING to convert recess into surface complete all as specified and directed
Supply and fixing in replacement surface mounting energy saving LED tube light fitting, T8 (4 ft), 1 x 18 W, 6500 K, 2100 lumen, 230 V, ultra bright, glass shell, glare free, white light, wide angle, double side connection retrofit with G 13 lamp holders with inbuilt driver including pre-coated CRCA covered batten, box type, prewired including removing old fitting complete all as specified and directed.
Fixing only LED bulkhead, with opal diffuser including taking out old fitting complete all as specified and directed Note : Fitting shall be issued by department under Sch 'B' for fixing only
Supply and fixing in replacement of ball bearing 6201 of ceiling fan complete including testing of fans complete all as specified and directed.
Supply and fixing in replacement of ball bearing 6202 of ceiling fan complete including testing of fans complete all as specified and directed.
Supply and fixing in replacement of gun metal bush of suitable size complete all as specified
Material and labour for rewinding of ceiling fan motor 240 volt, 50 Hz, 1400 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed.
Material and labour for rewinding of ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed.
Material and labour for rewinding of exhaust fan motor 240 volt, 50 Hz, 300 mm sweep, any make, with super enameled copper winding wire of existing size, same No. of turns, wound with machine, providing insulation material of E-grading, varnishing, connection with flexible copper wire 0.472mm dia upto connector block complete all as specified and directed.
Taking down ceiling fans, any make and size, removing electrical connection, dismantling blades etc, opening of motor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of defective/ unserviceable ball bearing and other parts, reassembling motor and fan, testing and hanging in position complete all as specified and directed. Make: Spare parts shall be measured & paid separately.
Taking down exhaust fans, any make and size, removing electrical connection, dismantling blades etc, opening of motor, cleaning of fan body and blades using detergent, greasing and oiling of serviceable ball bearing, bushes, replacement of defective/ unserviceable ball bearing and other parts, reassembling motor and fan, testing and hanging in position complete all as specified and directed. Make: Spare parts shall be measured & paid separately.
Supply and fixing apparatus assembly complete with incoming/ outgoing brass pipe complete with gasket, nuts, bolts, washers as required for make of Bajaj Shakti water heater of capacity 15 ltr capacity complete all as specified and directed.
Supply and fixing apparatus assembly complete with incoming/ outgoing brass pipe complete with gasket, nuts, bolts, washers as required for make of Bajaj Shakti water heater of capacity 25/ 35 ltr capacity complete all as specified and directed.
Supply and fixing in repair heating element 1500 watt complete all as specified and directed.
Supply and fixing in replacement thermostat for geyser of capacity 35 Ltr/ 25 Ltr/ 15 Ltr complete all as specified and directed.
Supply and fixing in replacement PVC connection hot and cold water pipe 18" long, 15mm outer dia with brass nut and washer, both side complete all as specified and directed.
Supply and fixing in replacement GI pipe light grade ISI marked of size 100mm bore for cable protection including provision of PVC heavy duty bends complete for fixing along road/ floor along the pole including fittings complete all as specified.
All as per Srl Item No. 30.00 but 80mm dia bore
All as per Srl Item No. 30.00 but 50mm dia bore
Supplying, laying, jointing and testing in replacement underground XLPE insulated, armoured heavy duty electric cable insulated and PVC sheathed LT 1100 volt grade (heavy duty) with standard aluminum conductor of size 6 Sqmm 2 core laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed.
All as per Srl Item No. 33.00 but size 16 sqmm 4 core
All as per Srl Item No. 33.00 but size 25 sqmm 3½ core
All as per Srl Item No. 33.00 but size 70 sqmm 3½ core
All as per Srl Item No. 33.00 but size 95 sqmm 3½ core
All as per Srl Item No. 33.00 but size 185 sqmm 3½ core
Excavation in trenches in soft/ loose soil n. exc. 1.50 mtr wide and n. exc. 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick each layer complete all as specified and directed.
Removal of surplus spoil to a distance n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with 8cm thick layer before laying of cable and 15cm thick layer after laying of cable in trenches complete all as specified and directed.
Supply only old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, abutting each other complete all as specified and directed.
Laying only bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Re-laying retrieved bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed.
Supply and fixing in replacement earthing complete for transformer/ VCB panels/ LT panels with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of the plate at a depth not less than 1.50 metre below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 50mm bore medium grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 Nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. Note: If result is not achieved satisfactory, contractor will have to do re-earthing at his own cost. Nothing shall be paid extra on this account
All as per Srl Item No. 46.00 above but GI wire 4mm dia
Material and labour for scraping old paint from LT panels/ feeder pillars inner & outside off size with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey/ blue from top of PCC coping and marking number/ name of panel and feeders in alphabets not less than 50mm in size complete all as specified and directed
Material and labour preparation of old painted surface of steel tubular poles straight/ swan neck and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and two coats of aluminium paint to remaining part of poles above strips including painting of street light brackets, clamps and numbering the pole of height 7/9 mtrs complete all as specified and directed. Note : Colour for base of board and alphabets shall be decided by Engineer-in-Charge
Supply and fixing in replacement oval shaped post top lantern in prismatic finish made up of polycarbonate material suitable and including 10 W retrofit LED lamp (B-22 Base) all as specified and directed.
Material and labour for replacing MCCB 400 Amps, 4 pole with adjustable thermal magnetic release, 25 KA, ICS=ICS=100% complete all as specified and directed.
Material and labour for replacing MCCB 250 Amps, 4 pole with adjustable thermal magnetic release, 25 KA, ICS=ICS=100% complete all as specified.
Material and labour for replacing MCCB 200 Amps, 4 pole with adjustable thermal magnetic release, 16 KA, ICS=ICS=100% complete all as specified
Material and labour for replacing MCCB 100 Amps, 4 pole with adjustable thermal magnetic release, 16 KA, ICS=ICS=100% complete all as specified
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, power factor 0.90 suitable for LED street light of capacity 45W complete all as specified and directed.
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, power factor 0.95 suitable for LED street light of capacity 60W complete all as specified and directed.
Material and labour for replacing TP MCB, 25 Amp having rupturing capacity 10 KA complete all as specified. Make: Legrand/ Schneider Acti 9/ Siemens Betagard.
Material and labour for replacing TP MCB, 40 Amp having rupturing capacity 10 KA complete all as specified. Make: Legrand/ Schneider Acti 9/ Siemens Betagard.
Dehydration and filtration of existing transformer oil using transformer oil filtration cum dehydration plant to eliminate foreign particles and to improve di-electric strength upto 45 KV (min) in 2.5mm electrode gap and to bring the acidity within the permissible limit below 0.5 mg KOH/ Cm complete all as specified and directed. Record of di-electric strength of insulating oil achieved after dehydration shall be given in writing by the contractor to the dept.
Supply & filling transformer insulation oil conforming to IS-335 for topping up the level of oil having di-electric strength 45-60 KV (minimum) at a electrode gap of 2.5mm upto the required level of transformer and testing of di-electric strength of oil in transformer before and after filling. Make: POWER/ SERVO/ INSOLE/ UNIVERSAL/ SAVITA/ CASTROL. Note:- Transformer oil be supplied in sealed containers.
Supply and fixing filling of fresh and dry Silica gel inside the breather pocket and fixing properly with transformer including painting the outer surface of the breather assembly including taking out silica gel complete all as specified.
Material and labour for scraping and removing of old worn out transformer oil tank gasket and supply, fixing of new rubberized cork gasket sheet 6 mm thick in the tank top cover and to be pasted using gasket cement for the transformers of capacity 400 to 630 KVA including fixing the top cover with conservator complete all as specified.
Material and labour for replacement of copper cable for connection in LT panels for metering and CTs of size 4 sqmm FRLS single core duly crimped with copper thimbles and crimping complete all as specified and directed. Note : Cost of copper thimbles and crimping included
Fixing only LED FLOOD LIGHT of 120 watt and dismantled old unserviceable fitting complete all as specified and directed Note : Fitting shall be issued by department under Sch 'B' for fixing only
Fixing only street light of 25 watt and dismantled old unserviceable fitting complete all as specified and directed Note : Fitting shall be issued by department under Sch 'B' for fixing only
Material and labour painting of water treatment plant pipe line and induction motor of following sizes including scraping of old paint from GI pipe and induction motor with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey by using spray gun complete all as specified and directed :- (a) 50mm dia - 35 RM. (b) 80mm dia - 30 RM. (c) 100mm dia - 45 RM. (d) 200mm dia - 40 RM. (e) Induction motor-07 Nos
Material and labour scraping old paint from water filter at water treatment plant size 1600mm dia with emery paper, preparing old surface for painting and apply two coats of synthetic enamel paint in steel grey shade by using spray gun complete all as specified and directed.
Material and labour painting of sewage treatment plant pipe line and induction motor of following sizes including scraping of old paint from GI pipe and induction motor with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey by using spray gun complete all as specified and directed :- (a) 50mm dia - 55 RM. (b) 80mm dia - 50 RM. (c) Air blower motor-02 Nos (d) Raw sewage trust pump-02 Nos (e) Sludge pump-02 Nos (f) Filter pump-02 Nos (g) Press filter-01 No (h) Irrigation pump-02 Nos
Material and labour scraping old paint from water filter at STP size 1200mm dia with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey shade by using spray gun complete all as specified and directed.
Material and labour scraping old paint from fire hydrant of height 2 mtr and GI pipe at fire fighting plant with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey shade by using spray gun complete all as specified and directed. (a) 200mm dia-25 RM (b) 150mm dia-20 RM (c) Fire hydrant of height 2 mtr and 80mm dia-09 Nos
Supply and fixing in replacement sluice valve, flanged of class 1.6 PN of size 100mm dia complete all as specified and directed. Make: NVR/ BIR/ KARTAR/ BVI
Supply and fixing in replacement sluice valve, flanged of class 1.6 PN of size 150mm dia complete all as specified and directed Make: NVR/ BIR/ KARTAR/ BVI
Supply and fixing in replacement butterfly valve of size 80mm dia complete all as specified and directed Make: Advance/ Castle/ NVR/ Minar
Supply and fixing in replacement pressure gauge 4" dia 0 to 14 Kg/cm2 complete all as specified and directed Make: Advance/ Castle/ NVR/ Minar/ G Luck India
Supply and fixing in replacement 40mm gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified
All as per Srl Item No. 76.00 but 15mm
Supply and fixing GI tubing medium grade 50mm bore (in any length) with required fitting duly laid in trenches and connecting up with water supply mains including removing unserviceable tubing complete all as specified
All as per Srl Item No. 78.00 but size 40mm dia
All as per Srl Item No. 78.00 but size 25mm dia
All as per Srl Item No. 78.00 but size 15mm dia
Material and labour for disconnecting electric connection, pipe connection and taking out submersible pump & motor of capacity 7.5 HP from bore well/ sump and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same gauge and weight to existing including replacement of motor bush, thrust plate coupling complete with key and reassembling the motor and lowering it into bore well making it functional and testing complete all as specified
Material and labour disconnecting submersible pump from electric motor of capacity 7.5 HP and taking to workshop for repair and replacement of unserviceable part such as gun metal, bush impeller, assembly shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional condition testing the pump to the entire satisfaction of Engineer-in-Charge.
Supply and fixing lowering PVC insulated & PVC sheathed industrial 4 Sqmm 3 core flat submersible cables with bare bunched copper conductor for submersible pump motors with voltage grade 1100 volts generally conforming to IS 694/1990 complete all as specified and directed.
Dismantling of unserviceable induction electric motor for rewinding with same gauge of the original specification and re-fixing, re-aligning in original position the same after winding for smooth operation of motor of capacity 1 HP to 7.5 HP complete all as specified and directed .
Dismantling of unserviceable induction electric motor for rewinding with same gauge of the original specification and re-fixing, re-aligning in original position the same after winding for smooth operation of motor of capacity 10 HP to 20 HP complete all as specified and directed .
Material and labour for replacing MCB TP, 63 Amp having rupturing capacity 10 KA, complete all as specified Make: L&T/ Crompton Greaves/ Havells
Material and labour in replacement ball valve brass high pressure with polythene float and fly nut complete screwed for 15mm bore dia of iron pipe or brass ferrule and fixed complete all as specified
Taking off rainwater harvesting pit cover, cleaning of any size and depth upto 3m of pit in use by taking out complete water, solid polythene, silt etc from pit complete either manually or by pumping cleaning through by using brushing with wire brush including placing the rain water harvesting pit cover properly after cleaning fully functional to the entire satisfaction by Engineer-in-Charge.
Supply and fixing PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and directed.
Material and labour for servicing and maintenance of inner & outer unit of split type AC of capacity 1.5/ 2 TR of any make by cleaning for of condenser coil & evaporator coil with acid and washing of air filter, oiling and tightening of all nut, bolts etc. complete all as directed.
Servicing and overhauling of duct AC of (2 x 8.5 TR) by washing of coils with C-shine chemical indoor and outdoor unit checking up of electrical connections/ controls etc complete all as specified and directed.
Material and labour for detection of leakage in the system of AC plant package type of capacity 2 x 17 TR working capacity + 1 x 17 TR standby by charging CO2 gas maintaining pressure 350 PSI including checking of gas leakage points with halide torch/ soap foam solution in system including rectification of leakages by gas welding, tightening of all flare nuts, valves etc and after pressure test, flushing the system complete all as specified and directed.
Supply & charging refrigerant gas R-22 for 1.5/2.0 TR split/ window AC upto the required pressure and testing of plant complete all as specified and directed.
Material and labour for charging refrigerant gas in split type AC 1.5 TR capacity including vaccumizing, leakage test and rectification of leakages etc complete all as specified and directed. Note : Gas charges will be paid to contractor under other Sch item
All as per Srl Item No. 95.00 here-in-before but 2.0 TR
Material and labour for replacement of compressor sealed unit of capacity 1.5 TR unit suitable for Air conditioners split type including taking out to old unserviceable compressor and cleaning, flushing, vaccumizing the system, Re charging of gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and directed.
All as per Srl Item No. 97.00 here-in-before but 2.0 TR
Supply and fixing in replacement of copper pipe of size (1/2", 3/8", 1/4" & 5/8" dia heavy duty suitable for AC split type/ window type of capacity 1.5/2TR including cutting and soldering and testing and pressure etc complete all as specified
Supply and fixing in replacement insulation sheet suitable for copper piping of size 1/2" and 5/8'' complete all as specified.
Supply, installation, commissioning and testing in replacement of voltage stabilizer copper wound for automatic operation, wall mounted type having connecting lead 3 core PVC insulated stranded copper conductor and connection plate for output correction, single phase naturally air cooled indoor type & designed for input variation between 150 Volts to 290 Volts with output voltage stabilized at 230 V with accuracy of ± 2.5% having voltmeter, indicator for normal running and low & high cut out of capacity 5 KVA complete all as specified.
Fixing only AC box single pole & neutral sheet metal enclosure with 2 pin plus earth, 230 volts AC plug and socket suitable for MCB SPN,20 Amp complete all as specified. Note : AC Box with material shall be issued by department under Sch 'B' for fixing only
Supply and fixing in replacement capillary copper (heavy duty) of size 1/64" suitable for split type AC of capacity 1.5/2 TR complete all as specified.
Supply and fixing for PCB remote plate of AC split type 1.5/2 Ton complete with remote, all as directed. Make of AC’s: LG/ Voltas/ Sidwal/ Carrier/ Videocon/ Blue Star
Supply and fixing in replacement condenser coil made out of copper pipe and fins suitable for split type AC 1.5 TR as per existing size and type including cutting, soldering, brazing and testing and charging of gas as required for air conditioner functional complete all as specified.
All as per Srl Item No. 105.00 here-in-before but 2.0 TR
Supply, replacement, connecting and testing of condensor blower motor as per existing type and size suitable for 1.5/2 TR split AC 240 volts single phase, all as directed. Make: Khaitan/ Universal/ CG/ Carriar/ Voltas
Supply and fixing in repair drain out pipe of split type AC complete all as specified and directed.
Supply and fixing in replacement evaporative coil made out of copper pipe and fins suitable for split type AC 1.5 TR as per existing size and type including cutting, soldering, brazing and testing and charging of gas as required for air conditioner functional complete all as specified.
All as per Srl Item No. 109.00 here-in-before but 2.0 TR
Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for water cooler of capacity 40 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed.
All as per Srl Item No. 111.00 here-in-before but 80 Ltrs
Material and labour for charging of refrigerant gas in water cooler of capacity 40 ltr including vaccumizing, leakage test and rectification of leakages etc complete all as specified and directed. Note : Gas charges will be paid to contractor under other Sch item
All as per Srl Item No. 113.00 here-in-before but 80 Ltrs
Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for deep freezer of capacity 405 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed. Make: Kirloskar/ Usha/ Carrier.
Rewinding of condenser motor of water cooler of any capacity any make with super enameled copper wire including replacement worn out bushes etc and testing complete all as specified and directed.
Taking down old and unserviceable compressor and Supply and fixing new sealed compressor unit for refrigerator of capacity 415 to 551 Ltrs including cleaning, vaccumizing, gas charging and testing on load complete all as specified and directed.
Supply and fixing in replacement evaporative coil (cooling coil) of refrigerators of capacity 415 to 551 Ltrs including cutting, taking out to old coil, brazing/ soldering complete all as specified and directed.
Supply and fixing in replacement reversing valve 4 way complete with plunger, AC 220/240 Volts, 50-60 Hz all as specified and directed. Make Suswani cat part No. DHF-9 or equivalent.
Supply and fixing in replacement condenser fan, suitable to operate on AC, 220/ 240 V, 50 C/s for deep freezer/ water cooler complete all as specified and directed.
GULSHAN SINGH GHAI AND SON
KULDEEP SINGH
CHOUDHARY AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .