Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.4 LAccepted-AOC VILLAGE JALALPUR PO BAHADURGARH DISTRICT PATIALA | 1 | Accepted-AOC L-1 Bidder | |
| 2 | 2₹10.5 L+₹1.1 L (12.2%)Rejected-AOC HOUSE NO 243 STREET NO 9 EKTA VIHAR PATIALA PUNJAB | FAZILKA | PUNJAB | 152020 | 2 | Rejected-AOC L-2 Bidder | |
| 3 | 3₹10.7 L+₹1.4 L (14.7%)Rejected-AOC | 3 | Rejected-AOC L-3 Bidder | |
| 4 | 4₹10.8 L+₹1.4 L (15.5%)Rejected-AOC | 4 | Rejected-AOC L-4 Bidder |
Tender Value
₹10.8 L
EMD Value
₹21,506
Closing Date
4 Oct 2024, 4:00 pmClosed
AND GROUND WATER DIV PTA
AND GROUND WATER DIV PTA
Repairing / Renovation of Kothi No.1 of BML Canal Colony
2024_WR_127735_1
12/24-25
Open Tender
Civil Works - Buildings
Item Rate
90 days
PATIALA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹21,506
Yes
XEN BML CANAL AND GROUND WATER DIV PTA
25 Dec 2024
21 Sept 2024
5 Oct 2024
21 Sept 2024
4 Oct 2024
21 Sept 2024
26 Sept 2024
Amount
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-(ii) Wiring light point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (iv) Wiring 6 Amp. Wall socket point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (i) a Wiring fan point (without fan box)
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
12.5 mm thick plaster 1:4
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. (b)Glazing area above 0.09 sqm :3mm thick or 8.44 Kg/ sqm
PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694 /1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed)
PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694 /1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (Un-sheathed)
scraping:-Cement plaster
Wire Gauge Red meranti wood Sinker (20 to 21 kg per cft. Approx.) door shutter without springs housed in chowkats.(A) 35mm thick Rs. 1910
Red meranti Normal Super (18 to 19 kg per cft. Approx.) doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position Rs 2855+5.35%
Red meranti Normal (15 to 16 kg per cft. Approx.) doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position (ii) 35mm thick Rs.2376.00
Sal wood wrought
scraping:White wash and colour wash
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ) CSR 1048+5.35%
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side.
Providing and fixing 4mm thick hard board of approved quality in partition including fixing to frames with screws complete (Beading and frame work to be paid separately
Providing and fixing helical door spring150mm (superior quality) includingnecessary screws, complete. Iron helical spring
Street light
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade CSR 55 +5.35%=57.94
GARG BUILDERS (BID ID -589000)
VISHAL CONTRACTOR (BID ID -589014)
WAVE CONTRACTORS (BID ID -589195)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .