Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 0 ISLAMPUR BELDHA DEVIPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹11.3 L
EMD Value
₹22,000
Closing Date
13 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, O and MC-V, BTPS, Anpara
Office of The S.E., O and MC-V, BTPS, Anpara
Round the clock operation and maintenance of dust extraction/ suppression system in CHP, BTPS, Anpara
2020_RVUNL_513243_1
18/CHD-I/BTPS/2020-21
Open Tender
Miscellaneous Works
Fixed-rate
365 days
Anpara Thermal Power Station
As Per Tender Document
3 documents required · 3 mandatory
₹590
Dy. C.A.O., CFA and BO, BTPS, Anpara
₹22,000
23 Oct 2020
19 Sept 2020
15 Oct 2020
19 Sept 2020
13 Oct 2020
19 Sept 2020
19 Sept 2020 - 12 Oct 2020
120 days
Amount
Routine checking, attending of DE & DS system (cyclone units) of CHP including T/H & S/R system round the clock as per the scope of work.
Checking & preventive maintenance of the ventilation system of entire CHP(2X500 MW) including T/H, Emergency Hopper, MSS, SS-1, SS-2, PCH, SCH, Pent House, Battery room, Lift rooms, Bunker bay as per scope of work.
Routine checking, attending & minor maintenance of Sump Pumps of CHP area which includes 18 pumps located at 9 pumping stations e.g. T/H(-level), Emergency Hopper(-level) and other places of different capacities as per scope of work.
Operation of spray water pipe line and routine checking of CF Fans at Track hopper of CHP-2x500 MW, BTPS
Laying of MS/GI pipe line
15 mm to 65 mm
80 mm to 300 mm
Fabrication & erection of MS/GI Bends
15 mm to 65 mm (average 40mm)
80 mm to 300 mm (average 190mm)
Fabrication & erection of MS/GI Bends Tees
15 mm to 65 mm (average 40mm)
80 mm to 300 mm (average 190mm)
Dismantling of pipe lines
15 mm to 65 mm
80 mm to 300 mm
Erection of valves on flanges
15 mm to 65 mm (average 40mm)
80 mm to 300 mm (average 190mm)
Erection of valves with welded joint
15 mm to 65 mm (average 40mm)
80 mm to 300 mm (average190mm)
Dismantling of valves
15 mm to 65 mm (average 40mm)
80 mm to 300 mm (average 190mm)
Fabrication & erection of Flanges 25 mm to 300 mm (average150mm)
Excavation & back filling of earth
Attending leakage in lines by welding/patching
15 mm to 65 mm
80 mm to 300 mm
Servicing of valves (Gate valve, Glove valve, Butterfly valve, Non return valve)
15 mm to 65 mm (average 40mm)
Removal of chocking
Removal of chocking of discharge pipe of Sump pump
Removal of chocking of Drain line of DE Cyclone
Cleaning of Sump pump Pits
Emergency Hopper
Sump pump Pit up to 21 feet deep
Removal of chocking of Cyclones
Cleaning of Cyclones, its entire ducts, Extraction hoods & nozzle headers.
Cleaning of DE/DS Reservoir Tank.
Cleaning of Settlement Tank.
Stage – I
Stage – II
Stage – III
Repairing of Ducts/Extraction Hood by patching etc. (upto 100mm x100 mm)
Multistage vertical pump (4 kw - 16 kw)
Replacement of coupling
Replacement of Bearing/Bush
Replacement of Mech. Seal
Overhauling/re-visioning of pumps
Replacement of Gland packing
Overhauling of Sump pump (submersible type)
1.5 kw Pump
3.7 kw Pump
Ventilation system
Cleaning of Aluminium Viscous air filter of sizes (600x500x25mm, 600x600x25mm, 600x300x25mm) approximately 500 Nos.
Cleaning of Bird screens, wall cowl, silencers, duct work etc of fans
Centrifugal Fans
Replacement of damaged foundation T bolt
Replacement of damaged V belt
Replacement/re-visioning of Bearing/plummer block
Repairing the Shaft of the Fan
Replacement/repair of Canvas flexible.
Repairing of Impeller by welding etc. and Balancing there after
Overhauling of Centrifugal Fan
Servicing of fire spray nozzle.
Attending leakage in underground pipeline by welding/patching up to 300mm dia. and 5ft deep
Overhauling of Sump pump (submersible type) 12KW- 20KW.
Over Hauling/Mechanical Maintenance of Ventilation Fan
Maintenance of water spray/over head water spray system by welding/patching at T/H, around/along with road/lawn etc.
THE UNIVERSAL CONSTRUCTION
M/S UNIVERSAL ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .