Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.1 L+₹1.2 L (8.63%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹15.4 L+₹1.5 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Nov 2021, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2021_MES_480407_1
GE/NRC/8840/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹40,000
Yes
1 Dec 2021
7 Oct 2021
6 Nov 2021
7 Oct 2021
4 Nov 2021
21 Oct 2021
Amount
Taking down of ceiling fan/exchaust fan of any size /sweep after disconecting the wire from existing ceilling rose and refixing the same after cleaning dust ,oiling ,greasing & hanging camps (if required) complete including providing flexible twin core copper conductor stranded cord from ceilling rose to connection of fan upto 1 mtr length complete all as directed by Engr -in- charge,Notes :- Works will be carried out at the site on routine basis.
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed including taking down.(Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares required shall be measured and paid separately in the relevant items).
Taking down old universable rused ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1200mm sweep size complete all as specified and directed.
Taking down old universable rused ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1400mm sweep size size complete all as specified and directed.
Taking down old universable rused exhaust fan blades and providing new exhaust fan blades with fixing new screw as apporpriate shape /size suitable for exhaust fan of any make and size of sweep complete all as specified and directed.
Painting of ceiling fan/ 1200/1400 mm sweep/exhaut fan 225 to 450 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
Taking out worn out gun metal bush and supply and fix new gun mettal bush for various make of ceilling fan of size 1200 to 1400 mm sweep complete all as specifide and as directed.
Supply and fix bearing for ceiling fan (Bearing No.6201).
Supply and fix bearing for ceiling fan (Bearing No.6202).
Supply and fix bearing for ceiling fan (Bearing No.6203).
Supply and fix bearing for ceiling fan (Bearing No.6204).
Taking out defective capacitor and supply and fix new capocitor of 2.5 MFD 230 volts with conector(capacitor holder with nut) including PVC clamps nuts , as approved make for various make of ceilling fan complete all as specified as directed.
Taking out defective capacitor and supply and fix new capocitor of 4 MFDas approved make for various make of exhaust fan complete all as specified as directed.
Taking out defective capacitor and supply and fix new capocitor of 6 MFDas approved make for various make of exhaust fan complete all as specified as directed.
Taking down and dismantling of 1200MM ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape,Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spareparts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items ( Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No) and including necessary transportion to workshop, for following sweeps of ceiing fan .
- ditto all as per Item No. 15 but 1400MM
Fixing or hanging only ceiling fan after rewinding fan under item No. 15 above and , connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Takning down/Overhauling exhaust/wall mounted fan of any type and size after discunecting the conection from exiting ceilling to connector and transpotation to work shop /cleanig externally dismantlling and examining the rotter /stator /bearing/bushing etc for serviciablity /repairing/replacing/defective part subsequntly oiling /greasing/asembling/testing of propper functoining cheking for sefty/ security and propper locking transporting back to building /site to workshop/hanging /fixing/and connecting /the electrical conection testing of noise free smooth runing etc.all as directed
Taking out defective /burnt winding of exhaust fan of various make of size 225 mm sweep working on 230 to 380 volts single phace /AC supply and Rewinding with supper enamiled new copper wire of apropriate Gauge including warnishing good quality varnish heating and re assembling the fan /testing /transpotation /placment/of connector flexible copper wire size 23/0.0040 , 3 core up to one metre complete all as specifiede and directed.
All as Itam No 19 above but for exhaust fan rewinding of size 250mm sweep
All as Itam No 19 above but for exhaust fan rewinding of size 380mm sweep
All as Itam No 19 above but for exhaust fan rewinding of size 450mm sweep
Fixing only exhaust fan after winding fan any hight under item No. 18 to 21 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
Supply only Split pin
Supply, fixing in repair and connecting up flexible copper cable twin core of 0.75 Sqmm.
Taking out rusted /defective down rod and supply and fix new down Rod of midium grade GI tubing 15mm bore having holl and threading at ends as per site requirement complete specified all as directed.
Removing broken /cracked Canopy of any make and type and supply and fix new canopy of existing make and size all as directed.
S&F in repair Rubber real for fans clamp complete all as per sample
For Geyser Work
Taking down/maintenance for parts of geysers of any capacity /make after disconecting the wire from existing power point and refixing the same after repair/replacement of heating element, thermostate, geyser assembly, PVC pipe & anchor bolts (if required) complete including providing T-3 core copper conductor cord from power point to geyser input upto 1 mtr length complete all as directed by Engr -in- charge, Notes :- 1. Work shall be carried out at the site on routine basis , 2. Spares (heating element, thermostate, ARV, NRV, PVC pipe, gaskit & anchor bolts will be measured separetly)
Taking down and fixing on the site of old & unserviciable geyser after repair to verticle /horizontle tank of any Make ,capacity 25 to50 ltr all as specifide and directed .
S& F in repairs cable PVC insulatd 3 core 2.5 Sqmm with stranderd copper conductor 1100V grade from socket /switch to geyser.
M&L for repair to geyser inner water tank of 25/50 ltrs capacity by gas welding /brazing for water tightness and testing complete
Supply and fix in repair 20A SP/SPN plug and socket inclosure in sheet steel inclosures without SP/SPN MCB complete all as specified and directed.
S&F in repair of Geyser water storage tank vertical/horizental type campicity 25 ltr make of metal copper/stainless steel as specified and directed
S&F in repair of Geyser water storage tank verticle/horizental type campicity 50 ltr make of metal copper/stainless steel as specified and directed
Taking down and refixing on the site after repair of geyser (new generation) of any make and capacity including providing heating element, thermostate, neno lamps, NRV, ARV, gas welding /brazing and any other important part as required on site, to make it serviceable, complete all as specified and directed by Engr-in-Charge.
Taking down and refixing on the site after repair of solar geyser of any make and capacity including providing heating element, thermostate, neno lamps, NRV, ARV, gas welding /brazing and any other important part of solar plate as required on site, to make it serviceable, complete all as specified and directed by Engr-in-Charge.
S&F in repair Glass wool pf any colour complete all as directed by Engineer-in-Charge
S&F in repair heating element tringle type 1500 watt , complete all as specified and directed by Engineer –in-Charge.
S&F in repair heating element cup type1500 watt, complete all as specified and directed by Engineer –in-Charge
S&F in repair heating element thread type 1500 watt , complete all as specified and directed by Engineer –in-Charge
S&F in repair heating element tringle type 2000 watt , complete all as specified and directed by Engineer –in-Charge
S&F in repair heating element cup type 2000 watt, complete all as specified and directed by Engineer –in- Charge
S&F in repair heating element thread type 2000 watt, complete all as specified and directed by Engineer –in-Charge
S&F in repair themostate for geyser, complete all as specified and directed by Engineer –in-Charge
S&F in repair neno lamp for geyser yellow /red/green, complete all as specified and as directed by Engineer –in-Charge
S&F in repair air realese valve for geyser as specified and as directed
S&F in repair Non returned valve 15mm for geyser all specified and as directed
S&F in repair flexi PVC connection armoured type both side brass union type nuts 45/60/90cm length as specified and directed.
S&F in repair anchor bolts 75mm long made out of stain less steel complete all as specified and directed
S&F in repair gasket rubber ring of Heater plate of any size geysers.
NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 80,491.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
UNITED ENTERPRISES
M/S S.N ENTERPRISES
Bidder Name
sapana enterprises
UNITED ENTERPRISES
M/S S.N ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .