| 1 | L1₹13.8 LAccepted-AOC FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹14.4 L+₹62,812.20 (4.57%)Rejected-Finance JAI DURGA CONSTRUCTION COMPANY SAILI BYEPASS ROAD PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹15.1 L+₹1.4 L (10.1%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹17.1 L+₹3.3 L (24.0%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being not a lowest | |
| 5 | L5₹18.6 L+₹4.9 L (35.6%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Being not a lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR REPLACEMENT MAINTENANCE OF SECURITY LIGHTS, POLE JUNCTION BOX AND ALLIED WORKS AT AOR OF AGE EM UNDER GE (WEST) PATHANKOT
2022_MES_504312_1
GE/PKT-65/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹70,000
Yes
25 Mar 2022
28 Jan 2022
28 Feb 2022
28 Jan 2022
26 Feb 2022
12 Feb 2022
29 Jan 2022 - 10 Feb 2022
60 days
Amount
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and directed by Engr-in-Charge. Make:- HPL cat part no- HPLLEDSL6060E or equivalent in any of the make mentioned in list of products.
All as per srl item No.1.00 here-in before but 72 watt. Make:- HPL cat part no- HPLLEDSL7260A or equivalent in any of the make mentioned in list of products.
All as per srl item No.1.00 here-in before but 90 watt. Make:- HPL cat part no- HPLLEDSL9060E or equivalent in any of the make mentioned in list of products.
All as per srl item No.1 here-in before but 100 watt. Make:- HPL cat part no- HPLLEDSL10060E or equivalent in any of the make mentioned in list of products.
All as per srl item No.1 here-in before but 120 watt. Make:- HPL cat part no- HPLLEDSL12060E or equivalent in any of the make mentioned in list of products.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with Thermal management in multiple optics and equipped with IP66 protection, with pact and corrosion resistant complete with driver and lamp. Make:- HPL Cat Part no- HPLLEDFL10060F or equivalent in any of the make mentioned in list of products.
All as per srl item No.6.00 here-in-before but 120 watt Make:- HPL Cat part no- HPLLEDFL12060F or equivalent in any of the make mentioned in list of products.
Note for ser no 1 to 7 of BOQ :- The LEDs used in the product shall be of reputed make like Citizen Japan / Nichia Japan with minimum LED efficacy of 130lm/W. The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs @ L70. The LEDs used in Street Light shall have CCT of ANSI Bin Warm White (between 5000-6500 K ) with CRI of 70. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V. The LED Street Light luminaire shall have secondary lens optics for optimum light distribution. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED luminaire shall have minimum 3.2KV surge protection. The LED Street Light shall have power factor more than 0.95 with THD less than 10%. LED Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. The driver should be fully designed and manufactured in India .The letter of Association with LED manufacturer for LEDs used in the fixture should be submitted to ensure high quality led chips are used in the fixture. LM79, LM80 and phtobiological reports should be submitted.
Supply and fixing in replacement of Drive suitable for LED street light /flood light/high bay light of 45,60,72/70 Watt as per sample all as specified and directed by Engr-In-Charge
Supply and fixing in replacement of Drive suitable for LED street light /flood light/high bay light of 90,120,150 Watt as per sample all as specified and directed by Engr-In-Charge
M&L for of bracket in replacement for fixing of street light fittings bend to shape, made out of 32 mm dia GI pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
S&F of two core Aluminium conductor PVC insulated cable of size 6 sqmm FR multistranded 1100 volts grade complete all as directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
All as per item No. 13.00 here-in-before but depth exceeding 1.5 mtr and not exceeding 3 mtr.
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified. Note :- Punned thickness 18 cm will be measured for payment.
Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade of cross-sectional area 16 Sqmm, 2 core including taking down of old UNSV cable complete all as specified and directed.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade of cross-sectional area 10 Sqmm, 2 core including taking down of old UNSV cable complete all as specified and directed.
M&L for GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and directed.
M&L for Prestressed concrete pole, 9.0 metres long 102mm x 152mm at top and 102 mm x 289 mm at bottom, class 10 in replacement including dismantling of old UNSV pole , numbering new pole and applying two coats of synethic enamel paint upto 1.5 mtr from top of coping for black and white strip alternately each 30 cm wide complete all as specified and directed. Note: Earth work including excavation, Returning filing, PCC work, removing excated material will be measured and paid separetly under respective items of schedule.
M&L for PCC 1:4:8, type D-2 ( Using 40mm graded stone aggregate) as in foundation filling and mass concrete of pole complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 ( using20mm graded stone aggregate) as in foundation of poles/coping, stay etc complete all as specified and directed.
M&L for sheet metal enclosure of (out door pole mounted double door boxes IP 54 with metric knock outs for cable entry) for single row 4 WAY MCB mountable out door pole mounting type having entry from lower side with cable gland for cable of size 10/16 Sq mm 2 core including locking arrangement complete and enclosure to be fitted on pole with clamps nuts, bolts and washers including making connection from Junction box to S/L fitting with 6 sqmm PVC insulated FR cable for phase & neutral complete or all as specified and directed by Engr-in-Charge. MAKE:- Indoasian cat part no 811805 or equivalent in any of the make mentioned in list of products.
Supply and Fixing Automatic street light timer switch single phase 3kW, 230 V as a pole mountable SMC enclosure consisting of Nature Switch-02 as the controlling unit, Power Contactor(s) & MCBs 16 Amps (both Input-Output) of suitable power rating and Copper wiring (min.10 sq.mm.) with proper lugs & terminal blocks. The SMC enclosure comes complete with open able door and mounting clamps. Outdoor mountable conforming to IP56 complete all as specified and directed. Make : Indoasian cat part no TL016ABD or equivalent in any of the make mentioned in list of products.
Supply and Fixing Automatic street light timer switch single phase 3kW, 230 V as a pole mountable SMC enclosure consisting of Nature Switch-02 as the controlling unit, Power Contactor(s) & MCBs 32 Amps (both Input-Output) of suitable power rating and Copper wiring (min.10 sq.mm.) with proper lugs & terminal blocks. The SMC enclosure comes complete with open able door and mounting clamps. The SINTEX make enclosure is made of UV stabilized, FR grade special moulding compound and it is Rust proof, Electric Shock proof,f, Outdoor mountable conforming to IP54 complete all as specified and directed. Make:- Indoasian cat part no TA916422 or equivalent in any of the make mentioned in list of products.
S&F of MCB SPN 240V, 50Hz, 10 KA, 'C' curve of rating 6-32 Amp complete all as specified and directed
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (50,580.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
JAI DURGA CONSTRUCTION CO
M/S SHAKTI ELECTRIC WORKS
M/S SATPAL AND BROTHERS
malghotra construction co
M/s. Aggarwal Engineers
dinesh enterprises
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .