| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹31.6 L+₹1.7 L (5.54%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹35.6 L+₹5.7 L (19.1%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹37.9 L+₹8.0 L (26.7%)Rejected-Finance | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹39.4 L+₹9.5 L (31.7%)Rejected-Finance 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L5 | Rejected-Finance RATE HIGH |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
3 Oct 2023, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 411040
8474 PREVENTIVE MAINTENANCE REPAIR OF PROTECTIVE SYSTEM SWITCH GEAR CHANGE OVER REPLACEMENT OF CABLE MAINTENANCE OF PANEL LT DISTRIBUTION SYSTEM AND MISC WORK OF ELECT SUPPLY IN CH COMPLEX CHSC CMDC RF LINE MI LINE AGE E/M I OF GE SOUTH PUNE
2023_MES_617429_1
8474 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE South Pune
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹98,000
7 Dec 2023
6 Sept 2023
6 Oct 2023
6 Sept 2023
3 Oct 2023
21 Sept 2023
Amount
Attending emergent complaints in “4 RMC area, Saibab complex, ALC qtrs, RF line, LH road, Gwalior line and other residential ACCN” area i.e “HT/LT fault, security light / MCCB tripping / Cable fault of any size, require it to make functional by replacing fuse, small piece of wire, Copper thimble, glands etc, complete all as directed by Engr-in-charge. Note : (i) The cost of fuse wire, copper thimbles, glands etc shall be deemed to be included in unit quoted rates. (ii). Attending of one number complaint / fault and make it functional complete in all respect will be measured as one Job.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in soft / loose soil complete all as specified and as directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in hard / dense soil complete all as specified and as directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in soft / disintegrated rocks complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed.
M&L for laying reinforced concrete pipes, class NP2 of dia 100 mm, 2 nos half round (for bottom and top) and before laying exacaved area shall be leveling complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 32x6 mm size GI strip up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth strip protected by galvanised iron 40 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing strip shall be encased in and including 50mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) GI strip and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit quoted rate.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6mm galvanized iron strip, complete all as specified and directed.
Supplying, laying, testing and commissioning of size 185 Sqmm 3.5 core underground LT cables 1100 volts grade, XLPE insulated, PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty conforming to IS - 1554 Part-I with and including cable glands, crimping type cable lugs in LT panel / MCCB in bldg etc. to suit the cable, laid in trenches / fixed to poles / drawn through pipes complete all as specified and as directed
All as per Sl. item No. 12.00 above but 150 sq mm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 120 sq mm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 95 sq mm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 70 sqmm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 50 sqmm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 35 sqmm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 25 sqmm 3.5 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 16 sqmm 4 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 10 sqmm 2 core complete all as specified and as directed.
All as per Sl. item No. 12.00 above but 6 sqmm 2 core complete all as specified and as directed.
M&L for providing cable testing van (Fault Finder) for detecting the location of fault in the LT / HT underground cable 1.1 / 11 KV of any size complete all as specified and as directed
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 150 to 240 Sqmm 3.5 core including all accessories required complete all as specified and as directed by Engr-In-Charge.
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 95 to 120 Sqmm 3.5 core including all accessories required complete all as specified and as directed by Engr-In-Charge.
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 25 to 70 Sqmm 3.5 core including all accessories required complete all as specified and as directed by Engr-In-Charge.
S&F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 6 to 16 Sqmm 2/4 core including all accessories required complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of outdoor end termination joint cable jointing kit out door heat shrink type suitable for 11 kv HT cable 95 sq mm 3 core with jointing material including all accessories required complete all as specified and as directed.
S&F in replacement of outdoor end termination joint cable jointing kit out door heat shrink type suitable for 22 kv HT cable 95 to 120 sq mm 3 core with jointing material including all accessories required complete all as specified and as directed.
S&F in replacement of MCCB 63 Amps to 100 Amps,16 KA, 3 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 63 Amps ,16 KA, 4 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 100 Amps,16 KA, 4 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 125 Amps, 16 KA, 3 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 125 Amps, 16 KA, 4 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 200 Amps, 36 KA, 3 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 200 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 250 Amps, 36 KA, 3 Pole,415 V complete all as specified and directed.
S&F in replacement of MCCB 250 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 400 Amps, 36KA, 3 Pole, 415V complete all as specified and directed.
S&F in replacement of MCCB 400 Amps, 36 KA, 4 Pole, 415V complete all as specified and directed.
S&F in replacement on load change over switch disconnector in Sheet metal enclosure 200Amps 415 Volt 4 Pole, Model C&S Cat no MM series 200A E-CSCS200NM4CO or equivalent cat part of the make as mentioned here-in-after, complete all as specified and as directed
S&F in replacement Capacitor duty Contactors sutable for 5 KVAR capacitor complete all as specified and directed by Engr-In-Charge. (Make- C &S CAT NO- TC1D07K02 or equivalent cat part in Siemens / Schneider/LEGRAND makes)
S&F in replacement Capacitor duty Contactors sutable for 10 KVAR capacitor complete all as specified and directed by Engr-In-Charge.
S&F in replacement Capacitor duty Contactors sutable for 20 KVAR capacitor complete all as specified and directed by Engr-In-Charge.
S&F in replacement Capacitor duty Contactors sutable for 25 KVAR capacitor complete all as specified and directed by Engr-In-Charge.
S&F in replacement Capacitor bank of 5 KVAR capacity suitable for existing capacitor panel complete all as specified and directed by Engr-In-Charge. (Make- Legrand CAT NO- 5150 04 or equivalent cat part in Siemens / Schneider/L&T/C&S makes)
S&F in replacement Capacitor bank of 10 KVAR capacity suitable for existing capacitor panel complete all as specified and directed by Engr-In-Charge. (Make- Legrand CAT NO- 5150 06 or equivalent cat part in Siemens / Schneider/L&T/C&S makes)
S&F in replacement Capacitor bank of 20 KVAR capacity suitable for existing capacitor panel complete all as specified and directed by Engr-In-Charge. (Make- Legrand CAT NO- 5150 09 or equivalent cat part in Siemens / Schneider/L&T/C&S makes)
S&F in replacement Capacitor bank of 25 KVAR capacity suitable for existing capacitor panel complete all as specified and directed by Engr-In-Charge. (Make- Legrand CAT NO- 5150 10 or equivalent cat part in Siemens / Schneider/L&T/C&S makes)
S&F in replacement door suitable for out door LT pannel made out of CRCA sheet 3.15 mm thick bend on side of match the existing door duly powder coated with and including new hinges 03 Nos., sutable for any size / shape of pannel complete all as directed by Engr-In-Charge.
S&F in replacement, Post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as diorected.
S&F in replacement Post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as diorected.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) The cost of 7.50 m GI pipe for protection & 4mm dia GI earth wire for each earthing shall be deemed to be included in unit quoted rates.
S&F earth continuity conductor or main earthing GI lead fixed to wall or pole on floor of size 4mm dia steel wire complete all as specified and as directed.
S&F LED Based bollard of 10 Watts with aluminium pipe housing with glare free PMMA diffuiser, IP 65 protection of model Halonix HLOB-02-10-CW or equivalent cat part in Crompton / Bjajaj / HPL / Wipro / Luker / BELNO complete all as specified and as directed.
S&F in replacement timer distribution boards of 32A 3pole / 230 V- with Analog Time Switch (with battery back up) of 3 mod DIN Daily 3P Module, 24 hours program, programmable every 15 min, backup of 100 hrs, current capacity 16A, with 1 change over (1 CO). conforming to Make- Indo Asian Timelite distribution boards conforming to Cat no-TL032ABO or equivalent cat part in HPL / Havells makes including connecting with street light and testing complete all as specified and directed by Engr-In-Charge.
Supplying, installation, testing and commissioning of free standing floor mounted, dust and vermin proof suitable size for outdoor installation factory made both front and rear side double door system panel, fabricated from 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted with epoxy powder paint by means of electro static gun after rigorous pre-treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkable sleeves, with 600 mm depth of the panel.
The panel shall be modular/cubical type with bus chamber cable ally and provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door, front and rear openable with locking arrangement and suitable for 1100 Volts grade, 3 phase 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 50x50x6mm, embedded 200mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate, 600 mm above ground level and comprising the following including taking out of old panels etc, removing of cables and connecting to new panels with all required material such as glands, lugs etc including dismantling of old unserviceable LT Panel with and including the following provisions, complete all as specified and directed by Engr-In-Charge.
INCOMING :- (a) MCCB 4 pole 400 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No. incoming OUTGOING :- (a) MCCB 3 pole100 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos. out going (b) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 03 Nos. Out going (c) LT Danger notice plate -01 No. (d) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
Supply and laying 40mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of underground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt / nuts etc. for fixing on walls, poles etc. including taking down / taking out of old unserviceable pipes complete all as specified and directed.
All as per Sl. item No. 58.00 above but 50 mm bore complete all as specified and as directed.
All as Sl. item No. 58.00 above but 80mm bore complete all as specified and as directed.
S&F in repair Integral LED Street Light Luminaire 25 Watts comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long including with accessories conforming to Make Cat Part No Halonix-HLSLD-09H-25-CWL-R or equivalent cat part in makes as mentioned here-in-after, complete all as specified and as directed.
S&F in repair Integral LED Street Light Luminaire 30 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long including with accessories conforming to Make Cat Part No Halonix-HLSLD-09H-30-CWL-R or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair Integral LED Street Light Luminaire 45 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories conforming to Make Cat Part No Halonix-HLSLD-09H-45-CWL-R or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair Integral LED Street Light Luminaire 60 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories conforming to Make Cat Part No Halonix-HLSLD-01-60-CWL-R or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair Integral LED Street Light Luminaire 70 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories conforming to Make Cat Part No Halonix-HLSLD-01-70-CWL-R-SH or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair Integral LED Street Light Luminaire 90 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories conforming to Make Cat Part No Halonix-HLSLD-06-90-CWL-R-SH or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair Integral LED Street Light Luminaire 120 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories conforming to Make Cat Part No Halonix-HLSLD-06-120-CWL-R-SH or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair Integral LED Street Light Luminaire 150 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories conforming to Make Cat Part No Halonix-HLSLD-06-150-CWL-R or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair LED flood lights fitting 70 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-70-CW-R01 or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair LED flood lights fitting 100 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-100-CW-R01 or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair LED flood lights fitting 150 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-150-CW-R01 or equivalent cat part in the makes as mentioned here-in-after, complete all as specified and as directed
S&F in repair electronic driver suitable for LED street light/flood light fitting of20/ 25 wattage complete for 230 Volt 50HZ AC supply complete all as specified and as directed by Engr-In-Charge. Make: Halonix / crompton / wipro / havells
S&F in repair electronic driver suitable for LED street light / flood light fitting of 60 to 72 wattage complete for 230 Volt 50HZ AC supply complete all as specified and as directed by Engr-In-Charge. Make: Halonix / crompton / wipro / havells
S&F in repair electronic driver suitable for LED street light/flood light fitting of 90 to 120 wattage complete for 230 Volt 50HZ AC supply complete all as specified and as directed by Engr-In-Charge. Make: Halonix / crompton / wipro / havells
S&F in repair electronic driver suitable for LED street light/flood light fitting of 140 to 160 wattage complete for 230 Volt 50HZ AC supply complete all as specified and as directed by Engr-In-Charge. Make: Halonix / crompton / wipro / havells
Material and labour for painting of steel tubular pole 9.0 m height including cross arm, clamp, back plate etc in situ on with one under coat and one finishing coat with aluminium paint after cleaning preparation of surface including making alternate yellow and black strip 30cm wide 5 nos. with two coat synthetic enamel paint complete all as specified and directed by Engr-in-Charge
S & F junction boxes outdoor type weather proof with fixing accessories made out of moulded PVC size 200x200x80 mm to be fixed at height of 1 mtr from bottom of street light pole complete with wiring, arrangement for MS clamp, cable entry / exit, 01 no MCB SP 6A, 4 pole connector for fixing cable etc complete all as specified and directed by Engr-in-Charge
Supply, fixing and errecting in true vertical position of steel tubular swaged pole swan neck type single arm 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth and exposed portion with Aluminium paint two coats over a coat of red oxide primer including taking down of old unserviceable / damaged pole complete all as specified and directed by Engr-in-charge. (Note : Excavation and earth work, PCC for foundation and coping shall be measured and paid seperately under respective item of BOQ)
Leo Enterprises
Rama Electricals
Mahindra Electric Stores
Anand Trading Co
M/S - SUJIT ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .