Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-Finance | ₹1.2 Cr | L1 | Accepted-Finance Lowest |
| 2 | L2₹1.4 Cr+₹14.3 L (11.6%)Rejected-Finance | ₹1.4 Cr+₹14.3 L (11.6%) | L2 | Rejected-Finance Second Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
31 Mar 2022, 5:15 pmClosed
Ex. Engineer (E and M)-I, SDMC
SOUTH DELHI MUNICIPAL CORPORATION OFFICE OF THE EXECUTIVE ENGINEER (Eand M)-I ROOM NO.2, NEAR GATE NO. 09, Dr AMBEDKAR STADIUM DELHI GATE, NEW DELHI-110002
SITC of electrical Pump along with E and M allied works at strom water pum house at pocket - 03 Bindapur Dwarka with operation and maintenance under SDMC
2022_SDMC_108898_1
EE (E and M)-I/SDMC/2021-22/07
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
90 days
Ambedark Stadioum SDMC
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹2.5 L
OFFICE OF THE SE(E and M), 02 ND FLO
9 May 2022
8 Mar 2022
31 Mar 2022
8 Mar 2022
31 Mar 2022
8 Mar 2022
14 Mar 2022
Amount
P&F M.S.Black pipe heavy C-Class confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of- Dia 80 mm
P&F M.S.Black pipe heavy C-Class confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of Dia 150 mm
P & F M.S.Black pipe confirming to IS: 3589 with required nut bolts & packing sheet etc complete as required of- Dia 350 mm, 8 mm Thick
P & F M.S.Black pipe confirming to IS: 3589 with required nut bolts & packing sheet etc complete as required of- Dia Dia 800 mm, 8 mm Thick
P&F of M.S. Flange with required nut bolts & packing sheet etc complete as required of Dia 80 mm (8 mm thickness)
P&F of M.S. Flange with required nut bolts & packing sheet etc complete as required of Dia 150 mm (16 mm thickness)
P& F of M.S. Flange with required nut bolts & packing sheet etc complete as required of Dia 350 mm, (16 mm thickness)
P& F of M.S. Flange with required nut bolts & packing sheet etc complete as required of Dia 800 mm (25 mm thickness)
P& F of M.S. Blank Flange with required nut bolts & packing sheet etc complete as required of Dia 800 mm (25 mm thickness)
P& F of M.S. Bend with required nut bolts & packing sheet etc complete as required of Dia 80 mm, 4.8 mm thick, 0.3 m
P& F of M.S. Bend with required nut bolts & packing sheet etc complete as required of Dia 150 mm 5.4 mm thick, length 0.5 m
P& F of M.S. Bend with required nut bolts & packing sheet etc complete as required of Dia 350mm, 8 mm thick
P& F of M.S. Bend with required nut bolts & packing sheet etc complete as required of Dia 800 mm, 8 mm thick, length 0.5 m
Supply of corrugated & chequered rubber mat having thickness 12 mm and size in 1M X 2M
P&F of CI Swing Type Non Return Valve Flanged end as per IS 5312 Body cover -CI IS -210 ,GR FG 260 Door -CI IS -210 ,GR FG 260 body Ring - Bronze IS -318 Gr LTB2 door face Natural rubber Hinge Pin -SS ASTM A276 & type 410 Fasteners-CS IS 1367 CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) NRV 80 MM
P&F of CI Swing Type Non Return Valve Flanged end as per IS 5312 Body cover -CI IS -210 ,GR FG 260 Door -CI IS -210 ,GR FG 260 body Ring - Bronze IS -318 Gr LTB2 door face Natural rubber Hinge Pin -SS ASTM A276 & type 410 Fasteners-CS IS 1367 CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) NRV 150 MM
P&F of CI Swing Type Non Return Valve Flanged end as per IS 5312 Body cover -CI IS -210 ,GR FG 260 Door -CI IS -210 ,GR FG 260 body Ring - Bronze IS -318 Gr LTB2 door face Natural rubber Hinge Pin -SS ASTM A276 & type 410 Fasteners-CS IS 1367 CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) NRV 350 MM
P&F of Cast Iron Non rising sluice valve Flanged end as per IS Body cover IS -14846 , body dome - wedge-CI IS 210 ,GR FG260 Body & Wedge Rings -Bronze IS 318 GR :LTB2 Spindle -SS IS 6603 Gr 12Cr 12 gland Packing -Greasy Jute Packing fasteners - CS IS 1367 , CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) SV 80 MM
P&F of Cast Iron Non rising sluice valve Flanged end as per IS Body cover IS -14846 , body dome - wedge-CI IS 210 ,GR FG260 Body & Wedge Rings -Bronze IS 318 GR :LTB2 Spindle -SS IS 6603 Gr 12Cr 12 gland Packing -Greasy Jute Packing fasteners - CS IS 1367 , CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) SV 150 MM
P&F of Cast Iron Non rising sluice valve Flanged end as per IS Body cover IS -14846 , body dome - wedge-CI IS 210 ,GR FG260 Body & Wedge Rings -Bronze IS 318 GR :LTB2 Spindle -SS IS 6603 Gr 12Cr 12 gland Packing -Greasy Jute Packing fasteners - CS IS 1367 , CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) SV 350 MM
P&F of Ball Valve with Flange Confirming to IS-9890-1981 (Three piece design) of size 80 MM
SITC of fully automatic Star Delta Motor Starter in sheet steel enclosure with SPP feature i/c connections etc. complete as required for 75 hp 3-phase 415V 50 Hz motor
SITC of fully automatic Star Delta Motor Starter in sheet steel enclosure with SPP feature i/c connections etc. complete as required for 40 hp 3-phase 415V 50 Hz motor
P&F 96x96 mm digital Ammeter with Ammeterr seelector switch 4 nos. and 2 CTs.
SITC of DOL Motor Starter in sheet steel enclosure with SPP feature i/c connections etc. complete as required for 5 hp 3-phase 415V 50 Hz motor
SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/ mixed/ sewage water having:- Rating: min. 40 HP Discharge: min. 350 m3/hr at Head- min. 20 Mtrs RPM - 1450 ± 10% Suction and delivery size: 150 mm dia. Casing: CI Impeller: CI/ Brass Shaft: SS Model/Make: As per OEM Along with complete base frame coupled with 40 HP motor suitable with 3-phase, 415 volt, 50 Hz supply complete as required, complete with coupling, coupling guard, AVM pads, foundation bolts, etc.
SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/ mixed/ sewage water having:- Rating: min. 75 HP Discharge: min. 1620 m3/hr at Head- min. 8 Mtrs RPM: 985 ± 10% Suction and delivery size: 350 mm dia. Casing: CI Impeller: CI/ Brass Shaft: SS Model/Make: As per OEM Along with complete base frame coupled with 75 HP motor suitable with 3-phase, 415 volt, 50 Hz supply complete as required, complete with coupling, coupling guard, AVM pads, foundation bolts, etc.
SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/ mixed/ sewage water having:- Rating: min. 5 HP Discharge: min. 40 m3/hr, Head- min. 15 Mtrs RPM: 1450 ± 10% Suction and Delivery size: 80 mm dia. Casing- CI Impeller- CI/ Brass Shaft: SS Model/Make: As per OEM Along with complete base frame coupled with 5 HP motor suitable with 3-phase, 415 volt, 50 Hz supply complete as required, complete with coupling, coupling guard, AVM pads, foundation bolts, etc.
P&F Onload changeover switch four pole in existing cubical panel mounted on MS frame, with advance neutral and operating handle conforming to IS:13947 (Part-3) complete as required 630 A
P&F Onload changeover switch four pole in existing cubical panel mounted on MS frame, with advance neutral and operating handle conforming to IS:13947 (Part-3) complete as required 400 A
P&F Onload changeover switch four pole in existing cubical panel mounted on MS frame, with advance neutral and operating handle conforming to IS:13947 (Part-3) complete as required 250A
P&F Onload changeover switch four pole in existing cubical panel mounted on MS frame, with advance neutral and operating handle conforming to IS:13947 (Part-3) complete as required 100 A
S/F installation of cubical panel board 16 SWG sheet M.S depth 30 cm to 60 cm with A1. bus bar andd interconnection suitable for switch gears i/c and making foundation etc as required.
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of size 3.5 core 300 sqmm
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of size 4 core 95 sqmm
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of size 4 core 35 sqmm
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of size 4 core 6 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Above 185 Sq mm and Up to 400 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Up to 35 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5X400 sq. mm(82 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4X35 Sq. mm(32 mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm ( Clamped with 1 mm thick saddle )
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable confirming to IS 7098 ( Part -I ) / 1988 as required. (a) 2 x 10 sq mm
S.I.T.Cof 150 W LED flood light luminiare fitted with lens made of pressure die cast aluminium housing &toughened glass cover complete with the following specification as required (b)Total system voltage =150 watt +/-5% (c) Luminiare Efficiency =100 Lm/w(d) Power Factor >=0.95 ( e) Protection Class - IP -66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm(NS)complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB &63 A double pole isolator(MCB/Isolator exluded )with neutral link duly shorting on DIN channelwith 2 nos.of clamps with SS back plate of suitable size with danger monogram & SDMC property printed on the cover etc. as required
S.I.T.C LED tube type luminaire 20 watt rating complete with Polycarbonate housing batten integrated electronic driver prewired with high efficiency LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing and fixing of 600 mm sweep Air circulater complete with blades, jaal workable on 220/240 volts AC supply etc as reqd.
Supply of 15'' (380mm)sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
Installation of exhaust fan in the existing opening including making good the damage,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep
Supply,installation,testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtrmtr,suction and delivery 25X25 mm
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. All works upto plinth level (For 06 Nos. main pump sets 1.2*2*1 = 2.4 cum each and for charging pump 1.2*0.8*0.6 = .576 cum)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-50D or more.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double Door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing suitable size GI box with modular plate and cover in font on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA, 4 Pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A,36KA, 4 Pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 A,50KA, 4 Pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 A,50KA, 4 Pole
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required..2x2.5 sq.mm +1x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required.4x2.5 sq.mm +2x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required.2x6 sq.mm +1x6 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. 2x 4 sq. mm + 1 x 4 sq. mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required.4 x 4 sq. mm + 2 x 4 sq. mm earth wire
Operation, watch and ward of pumping station round the clock operation by providing the staff:- Skilled Operator for Electric motor / Diesel pump set - One in each shift on each pumping station (3Nos. per day for 270 days) i.e.810 Nos.
Operation, watch and ward of pumping station round the clock operation by providing the staff:- Un Skilled Operator for Electric motor / Diesel pump set - One in each shift on each pumping station (3 Nos. per day for 270 days) i.e. 810 Nos.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing ABC( Aluminium Phosphate ) Power type fire extinguisher of 6 Kgs capacity complete in all respect with ISI mark i/c fixing arrangement etc as required as per technical specification attached .
Providing and fixing 4.5 kg Co2 type fire extinguisher sqeeze grip type , trolly wheel as well as wall mounting type complete in all respect with ISI mark i/c fixing arrangement etc as required as per technical specification attached .
SITC of EOT crane for operating bar screen, FIXED GOLIATH CRANE Capacity-2 Ton, SPAN-3 m
P&F of bar screen size 1m x 2m fabricated by MS strip of size 50mm x 6mm x 2250mm, frame fabricated by U-Chaneel, floating material collecting arrangement with guiding arrangement through 2 nos. U-channel each 2.5m long along with civil work. (Approximate weight 325 Kg)
Dismantling of existing 03 nos pumpset along with complete fittings, accessories, etc. (Dismantled old material shall be transported to SDMC E&M store)
RAMSH ELECTRIC WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .