Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹35.0 L+₹61,740 (1.80%)Rejected-Finance 6TH CROSS STREET KAMARAJ NAGAR PALAYAMKOTTAI | PALAYAMKOTTAI | TIRUNELVELI | TAMIL NADU | 627002 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹36.5 L+₹2.1 L (6.18%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹36.9 L+₹2.5 L (7.34%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹38.1 L+₹3.7 L (10.7%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38.8 L
EMD Value
₹77,500
Closing Date
7 Mar 2020, 6:00 pmClosed
CWE Army
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
Special Repair to Building No. P-01 (OR, OTM- Cum Tradesmen Shop) at certain unit Under GE (South) Bangalore.
2020_MES_316195_1
85954 / E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE south Bangalore
₹77,500
Yes
CWE ARMY BANGALORE
13 May 2020
24 Jan 2020
12 Mar 2020
24 Jan 2020
7 Mar 2020
15 Feb 2020
24 Jan 2020 - 31 Jan 2020
31 Jan 2020
Amount
Removing existing water proofing treatment including bedding concrete etc. complete cleaning the surface with wire brushes, removing dust, foreign material, scrubbing down with water and rubbish and disposing off out side MD land complete all as directed.
Demolition of cement concrete in of any description and in any position not otherwise specifically provided for complete all as directed.
PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) for filleting and benching, slightly rounded or chamfered on edges complete all as directed.
APP modified prefabricated water proofing membrane mineral finish, 3 mm thick and weighing not less than 3.60 kg / sqm reinforced with non woven polyester matt black finished over compatible primer at 0.40 Kg / Sqm and torch applications of membrane with 100 mm overlap after necessary preparation of surface top of the membrane surface shall than be finished with solar reflective aluminium paint @ 0.10 Kg / Sqm complete as per manufacturers instructions complete all as directed.
Cleaning of old concrete surface by roughening, sweeping, washing down and applying cement slurry @ 3 kgs / sqm complete all as directed
PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in 75 mm thick plinth protection / path / paving finished even and smooth without using extra cement including forming groove 10 mm wide, 30 mm deep, filled with mastic filler complete all as directed.
PCC, 40 mm thick, 1:2:4 type B0 using 12.5 mm graded stone aggregate as in floor finished even and smooth without using extra cement complete all as directed.
Glass dividing strips, 22 mm wide, 3 mm thick, inserted in position complete all as directed.
Taking down, easing and adjustment and refixing the door shutter in same or different location exc 1.5 Sqm but n. exc 2 sqm each complete all as directed.
Taking down chowkats (without taking of shutters from the frame) exc 1.5 Sqm but n. exc 4 sqm each complete all as directed.
Second class hard wood plain, solid, straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as directed.
35 mm thick glazed and skelton shutter, Second class hard wood for window, divided in squares open rebated and prepared to receive wire gauge (with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing gauge etc, sizes of members of shutters as specified in SSR Pt-I, section 8, clause 8.24 (a) complete all as directed.
35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail & panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail & stile as per IS 1003 (Pt-I), kiln seasoned & chemically pressure treated ccomplete all as directed.
30 mm flush door shutters, solid core construction with block board core and plywood face panels, commercial type on both sides including liping beading all round as in door shutter, cupboard shutter and kitchen rack complete all as specified in SSR Part-I section 8, Clause 8.20 (c) and as directed.
Butt hinges, medium weight, cold rolled, mild steel, 100 mm long complete all as directed
250 mm long aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed.
Barrel Tower Bolts, 200 mm long, Aluminium Anodised complete all as directed.
Handles, 125 mm, "D" type, Aluminium Anodised complete all as directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty in square / rectangular pane n.exc 0.50 sqm in each complete all as directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as directed.
Hacking out old broken glass (any thickness size quality or description) from wooden / steel frames or stone concrete or brick surrounds glazed with putty or fixed with beads complete all as directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty in square / rectangular pane n.exc 0.50 sqm in each, fixed in repair complete all as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including Racking out Joints, hacking for Key, scrubbing down with Water, etc. including removal of debris outside MD land complete all as directed.
Rendering 10 mm thick in CM 1:6 on stone massonary or concrete block walling surfaces finished even and smooth without using extra cement, complete all as directed.
Rendering 15 mm thick (in two layers) setting coat, 5 mm thick in CM 1:4, mixed with WPC as per manufacturer instruction over 10 mm thick backing coat in CM 1:6 on other than fair faces of brick work or concrete block masonary surfaces, finished even and smooth without using extra cement, complete all as directed. Note:- WPC will be measured and paid seperately.
Supply only Water Proofing Compound complete all as directed
Preparing newly plastered surfaces and applying two coats distemper Oil Emulsion white or tinted on walls over a coat of primer complete all as directed.
Preparing newly plastered surfaces and applying two coats of cement based paint on walls over a coat of primer complete all as directed.
Complete removal of existing treatment and preparing the old decorated wall surfaces with chalk whiting and applying two coat of OBD complete all as directed.
Complete removal of existing treatment and preparing the old decorated wall surfaces and applying two coat of cement base paint over a coat of white wash complete all as directed.
Preparing old wooden surface of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as directed.
Preparing new wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as directed.
Preparing old surface of steel material of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as directed.
Demolition of brick / block work or stone / boulder masonry, built in cement mortar complete all as directed.
Precast cement concrete block masonry with solid blocks grade C-5, exc 10 Cm in width and setting in cement mortar 1:6 complete all as directed.
Demolition of cement concrete in ground floors and pavings N. exc 150 mm thick (below or above ground level) complete all as directed.
Hardcore of broken stone or boulders of gauge N. exc 63 mm deposited spread and leveled in layer N. exc 150 mm thick, watered and rammed to a true surface complete all as directed.
Dismantling boarding of any description, fixed in position with nails etc. complete all as directed.
Supporting hanger comprising rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20 mm of the length) conforming to Fe 410-W- (Gde-E-250) quality-A complete all as directed.
False ceiling with GI snap frame work of size 600 x 600 mm in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 170 gsm / Sqm and bottom exposed width prefinished with baked polyester paint) consisting of main `T’ runners of size 38 x 24 x 0.3 mm with suitably spaced joints to get required length spaced at 1200 mm C/C and cross T of size 24 x 25 x 0.3 mm, 1200 mm long spaced between main T at 600 mm C/C to form a grid of 1200 x 600 mm and secondary cross `T’ of length 600 mm and size 24 x 25 x 0.3 mm to be interlocked at middle of the 1200 x 600 mm panel to form grids of 600 x 600 mm and wall angle of size 21 x 21 x 0.3 mm and laying flase ceiling tiles of 4 mm thick fibre, cement building board, non asbestos (minimum weight 4.8 kg / m2) fixed or laid / inserted to GI frame work with screws / clips for false ceiling work including, wherever required, cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main T runners shall be suspended from ceiling using GI slotted cleats of size 25 x 35 x 1.6 mm fixed to ceiling with 6 mm dia and 50 mm long metal dash fastener, 4 mm GI rods with galvanized steel leveling clips spaced at 1200 mm C/C along main `T’ section (False ceiling system shall be capable to bear distributed load of minimum 15 Kg / Sqm) complete all as directed
Cutting holes in stone / brick walls built in cement mortar and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1, N Exc. 150 Sq. Cm each complete all as directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc. complete all as directed.
Wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conforming to IS 694 drawn through and including non metalic rigid PVC casing caping for modular type steel sheet pressed terminal box (recessed) with modular frame and to cover including accessories, on wall, for housing the switches, switch sockets outlets, fan regulators etc. including provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for one light or fan point controlled by one way switch complete all as directed. Note : MS sunken boxes, cover plates with frame switches, sockets shall be measured and paid seperately in an appropriate item of Sch 'A' and laying / fixing of sunken box and cover with frame is included in quoted rate.
All as per Item No. 43 above but for One 3 pin socket outlet, 5 amps, on independent board.
All as per Item No. 43 above but One 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 43 but wire size 2.5 sqmm for 6 pin 15 Amps switch socket combination outlet on independent board.
Switch Modular type 5A one way complete all as directed.
One way modular switch 16A one Module complete all as directed.
Socket outlet 2 in 1, 3 pin, 5 Amps Modular type complete all as directed.
Socket outlet 6 / 16 Amps modular type complete all as directed.
Fan regulator electronic socket step modular type complete all as directed.
Ceiling rose surface bakelite 65 x 50 mm 3 terminals complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 2 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 3 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 4 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 5 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 6 module complete all as directed.
Taking down ceiling fan, dismantling blades and etc. for Painting of celing fans complete, in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc. and hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed.
Sub main wring concealed type with Four runs of single core, PVC insulated unsheathed multi-stranded copper conductor cable of size 10 sqmm, 1100 volts grade (FRLS) and one run of 10 sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as directed. Note : Four runs of 10 sqmm cable, one run of 10 sqmm continuity earth wire and one run of PVC non metallic conduit with all necessary accessories will be measured as one length.
Sub main wring concealed type with Two runs of single core, PVC insulated unsheathed multi-stranded copper conductor cable of size 10 sqmm, 1100 volts grade (FRLS) and one run of 10 sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as directed. Note : Two runs of 10 sqmm cable, one run of 10 sqmm continuity earth wire and one run of PVC non metallic conduit with all necessary accessories will be measured as one length.
TPN DB -VTPN DB with provision for FP MCB / Isolator as incomer and SP / TP MCBs as outgoing IP 43-IK 09 with acrylic door 4 way capacity (Make Legrand / Schneider / L&T )
Sheet metal enclosure (ISI marked) distribution board SPN, 415 volts, 8 way horizontal type, double door with 200 Amps rated copper bus bar for housing MCBs, fixed flush in wall surface, and tested in replacement complete all as directed.
Sheet metal enclosure (ISI marked) distribution board SPN, 415 volts, 12 way horizontal type, double door with 200 Amps rated copper bus bar for housing MCBs, fixed flush in wall surface, and tested in replacement complete all as directed.
MCB TPN 63 Amps, 415 Volts providing in DB complete all as directed.
MCB single pole and neutral (DP) 32 Amps 240 volts 10 KA rupturing capacity (curve-c) providing in DB complete all as directed.
MCB single pole 6 to 20 Amps 240 volts 10 KA rupturing capacity (curve-c) providing in DB complete all as directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth strip 25 x 4 mm by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20 mm graded stone aggregate and frame cover of angle iron 25 x 25 x 6 mm, MS sheet 3 mm thick and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering common salt chorcoal funnel wiremesh earth work in any type of soil returning filling in and removal of soft/loose soil to a distance n.exc 5 mtr including earth test point and making connections testing on completion all as per electric plate No 3 of SSR Part-I, complete all as directed.
Highly durable surface mounted LED battern 18W constructed of fire retardant engineering grade extruded plastic and decorative end caps including dismantling old one complete all as directed. Make Crompton Cat Part No LCTL-18-CDL or Polycab Cat Part No LD00103058 or Jaquar Cat Part No LT BL01X018XW.
Less Schedule "A" Credit (For Detail description, and rate of particular item, Please refer Schedule "A" Credit Page as attached in Tender Doccuments)
M/S POTHIRAJ AND CO
Elite Constructions
OM CONSTRUCTIONS
K. VENKATESH NAIDU
Sangam Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .