Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-Finance | L1 | Accepted-Finance Due to the urgency of the work so as to hand over the vacant building space to PES since this is 2nd call therefore this bid has been accepted |
Tender Value
₹4.9 L
EMD Value
₹10,000
Closing Date
9 Jan 2023, 3:00 pmClosed
EE CIVIL
BSNL CIVIL DIVION II HYDERABAD
Attending annual repairs and maintenance to TE Building and Type V Qtrs for rearrangement of staff, including renovation of toiletsfor Ladies and Gents staff, Tirumulgherry, Secunderabad. 2nd Call
2022_BSNL_139922_1
51/ BCDH I / 2022 23
Open Tender
Civil Works
Item Rate
60 days
TRIMUGHERY
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO PAY O/O PGM-HTD
₹10,000
14 Jan 2023
29 Dec 2022
10 Jan 2023
29 Dec 2022
9 Jan 2023
29 Dec 2022
29 Dec 2022 - 3 Jan 2023
Amount
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a)1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
b) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 )transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
12 mm cement plaster of mix :
1:4 (1 cement: 4 coarse sand)
Neat cement punning
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
One coat
Two coats
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
One or more coats on old work.
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (One or more coat applied @ 0.90 ltr/10 sqm).
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of thickness 4 mm.
Taking out existing wooden/aluminium door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Providing and fixing white vitreous china water closet squatting pan (Indian type) :
Long pattern W.C. pan of size 580 mm
Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete :
White solid plastic seat with lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :
Flat back wash basin of size 550x400 mm.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.
Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia .Pipes.
40 mm nominal outer dia. Pipes.
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT grating of approved quality and colour.
a) Circular type.
i)100 mm nominal dia.
Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms.
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
a)100 mm dia
b) 150mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
100 mm diameter
150 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
i) Rectangular shape 600x450 mm internal dimensions
ii) Square shape 450 mm internal dimensions
Providing & fixing fly proof wire gauze mesh to windows, clerestory windows & doors and to balcony grills with T.W. beading 15x1mm, nails & screws or with binding with GI wires as per site requirement and as directed by E-I-C etc complete.
Stainless steel (grade 304) wire gauze of 0.3 mm dia wire and 1.8mm aperture on both sides.
Providing and fixing M.S Brackets for wash basin/Sink or required size embedded in cement concrete including cutting and making good walls etc., all complete as per the directions of Engineer-in-Charge. Pair of brackets is measured for payment.
Providing and fixing Brass MABT/FABT including cutting and threading the GI pipe Line and connecting to CPVC line wherever required etc. complete
a)20 mm nominal bore
b)25 mm nominal bore
c)40 mm nominal bore
Cleaning of blocked Nahani trap / floor trap for removal of blockages including removing the silt , slush,, waste etc ensuring smooth flow etc., and applying white cement on the flooring around the trap and fixing the grating with white cement and disposal of all unwanted material to the approved muncipal dumping yard and wherever required to arrest the leakage from tile joints all complete etc.,and as per direction of Engineer in charge
Providing and fixing gun metal ball valve with SS ball & MS lever including cutting and threading the GI Line wherever required etc. complete
a)20 mm nominal bore
b)25 mm nominal bore
c)40 mm nominal bore
Providing UPVC SWR soil waste and vent pipes by cutting, removing, replacing with working pressure 6kgf/sq.cm conforming to IS : 13592 Type B including jointing with 'T' shaped seal/rubber ring conforming to IS : 5382 and with solvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant. (i)Single socketed pipe(couplings,other accesories will be paid seperately)
Providing on wall face damaged unplasticised - PVC moulded fittings/ accessories with new fittings/accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A including cutting,replacing,jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
Coupler
Plain bend of required degree
75mm bend
Tee with door
Door bend
Single Y with door of required degree
Providing and fixing unplasticised -PVC pipe clips of approved design for fixing of unplasticised - PVC pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting chases in brick work, fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall with rich cement plaster etc. complete.
Carting out of building rubbish / malba / similar unserviceable, dismantled, excavated or waste materials by mechanical means,through private carrier including lifting, loading, transporting, unloading to municipal dumping ground beyond 50 m initial lead,or in any other compound as decided by the Engineer-in-charge, for all leads including all lifts involved.
Cleaning of existing Type-V staff quarter at all heights by removal of cob web, pigeon droppings, debris, unwanted, un serviceable abandoned material etc from all the rooms, dusting of walls, windows, doors, cubboards etc, washing the flooring of all rooms with detergent, washing the flooring and dado of toilets and bath room with the acid etc.,making them into useable/liveable conditions complete etc for immediate occupation of quarter as directed by Engineer-in-charge.Each quarter cleaning is measured as one job.
a) Type-V Qtr
Cleaning of Under ground water storage tank or sump or over head tank of any capacity by following method: (1) Empty the tank/sump and make it to near dry, (2) Apply bleaching powder uniformly ( tank capacity @ 0.50gms/liter) surface of inside the tank/sump perfectly by removing scales on walls and wait for one hour (3) after one hour clean/rinse at the tank/sump with fresh water ,repeat the above process , (2) and (3) for two to three times , (4) remove the mud/silt/sludge and garbage from the tank with specified sludge pump, (5) spraying anti bacteria agents on walls to kill harmfull bacteria. Rate includes for all above operations including the equipment and material required for cleaning all complete as directed by the Engineer-in-charge.
Cleaning of existing Septic tank by mechanical pumping mechines and necessary labour including providing/spreading atleast 5liters kerosine on top of sludge inside the septic tank to avoid foul smell for the surrounding occupants, the deposited sludge/suspended material/night solin etc., should be removed and transported by mechanical transport beyond municipal limits including dewatering of liquids as directed by the engineer-in-charge.
Cleaning of terrace / canopy/ chajjas by removing leaves grass dust, rubbish and other deposited / accumulated materials etc including removal of blockages/chockages of khurras/spouts of terrace/chajjas etc and disposal of rubbish to the dumping ground out side periphery of the building. (plan area of the terrace/chajja/canopy will be measured for payment)
a) Terrace area connected to blocked khurras and spouts & like.
b) Chajjas area connected to blocked spouts & like
Cleaning of sewer lines, manholes etc.,at all depths. cost includes all labour for removing the sludge, silt, slush, waste etc., from the manholes and rodding the sewer lines by mobile sewer roding equipment from manhole to manhole to clear the blockage, including chokes in gully traps etc.and disposing the waste outside the compound etc., complete.as per directions of Engineer-in-charge) Sewer line upto 150mm dia. (Rate for sewer line between two no.manholes to be measured for payment ) and disposal of all unwanted material to the approved muncipal dumping yard etc all complete and as per direction of Engineer in charge (Nothing extra paid).
Removing and taking away of unserviceable G.I pipe lines complete etc., as directed by Engineer-in-charge. A) 15mm to 40mm nominal bore
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .