Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.3 LAdmitted-Finance WZ 553 3 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Admitted-Finance | ||
| 2 | L2₹4.4 L+₹2,634.79 (0.61%)Admitted-Finance | L2 | Admitted-Finance |
Tender Value
₹4.4 L
EMD Value
₹8,783
Closing Date
12 Aug 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Comprehensive maintenance of RO and Water Cooler
2026_PWD_296547_1
58/EE (E)/PWD EMD South West/2026-27
Open Tender
Electrical Works
Percentage
365 days
works
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹8,783
21 Aug 2026
5 Aug 2026
12 Aug 2026
5 Aug 2026
12 Aug 2026
5 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Annual Comprehensive Maintenance of 9 Nos. Eureka Forbes RO System 50 LPH capacity connected with water coolers i/c three mandatory services in a month (cleaning of All Filters), repair/ replacement of all electrical and electronic spare parts and one time replacement of consumables once in a year like Particulate Filter 20”(2 x 10”), Sediment Filter 20” (2 x 10”), Pre Carbon Filter 20” and Post Carbon Filter 20” (Except TFC Membranes), attending complaints within 24 working hours with complete overhauling and servicing etc. as required. Dismantle shall retained by the contractor. Total Machines at various Locations: (9 Nos. for 12 Months) | 12 | Per Month | 12,780 | ₹1,53,360 |
| 2 | Supply & Replacement of TFC RO Membrane 75 GPD i/c testing, commissioning etc. as required (Dismantle shall be retained by the contractor. | 70 | Each | 3,231 | ₹2,26,170 |
| 3 | Supplying and Charging of Refrigerant Gas in the Water Coolers after pressure testing leak detection and rectifying the brakage (if any) testing and commissioning complete as reqd. | 3 | Each | 3,035 | ₹9,105 |
| 4 | Supply and replacement of 10" Particulate/Sediment Filter Eureka Forbes make i/c Leak testing, commissioning etc complete as reqd. at site. Dismantle shall be retained by the contractor. | 7 | Each | 465 | ₹3,255 |
| 5 | Supply and replacement of 20" or 2 x 10" Particulate/Sediment Filter Eureka Forbes make i/c Leak testing, commissioning etc complete as reqd. at site. Dismantle shall be retained by the contractor. | 6 | Each | 861 | ₹5,166 |
| 6 | Supply and replacement of separately installed 20" Bowl for Pre filter Eureka Forbes make Leak testing, commissioning etc complete as reqd at site.dismantle shall retained by the contractor. | 1 | Each | 1,008 | ₹1,008 |
| 7 | Supply & replacement of defective tap of water cooler with new pvc coated metal Tap i/c leakage testing & rectifying the same as reqd.dismantle shall retained by the contractor. | 4 | Each | 587 | ₹2,348 |
| 8 | Supply and replacement of Pressure Generating Pump with Automated switching Device. | 1 | Each | 4,332 | ₹4,332 |
| 9 | Supplying and replacement of Chases of AG Revia RO 50 LPH. | 1 | Each | 3,280 | ₹3,280 |
| 10 | Supply and replacement of Automated switching on/off device for Water level monitoring of storage Water Cooler. | 6 | Each | 3,521 | ₹21,126 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.62 MB
BOQ_394766.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .