Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | ₹35.2 L Quoted ₹36.9 L | L1 | Accepted-AOC Lowest and Reasonable |
| 2 | L2₹41.7 L+₹4.8 L (13.0%)Rejected-AOC 12 MANAULI HOUSE AMBALA CITY 134003 HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹41.7 L+₹4.8 L (13.0%) | L2 | Rejected-AOC Other than Lowest |
| 3 | Rejected-Technical R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | - | - | Rejected-Technical Not Enlisted in b(iii) Category |
Tender Value
Refer Docs
EMD Value
₹93,000
Closing Date
14 Nov 2020, 6:00 pmClosed
CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
AUGMENTATION / MODIFICATION OF EXISTING 33 KV MRS BY REPLACEMENT OF SAFETY AND AUTOMATION SYSTEM TO AVOID FREQUENT BREAKDOWN IN THE SYSTEM AT AF UDHAMPUR
2020_MES_381588_1
CWEAFJ-21/2020-21
Open Tender
Civil Works
Item Rate
180 days
Udhampur
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Udhampur
₹93,000
Yes
4 Mar 2021
28 Sept 2020
19 Nov 2020
28 Sept 2020
14 Nov 2020
31 Oct 2020
Amount
Maintenance & complete overhauling of 33 KV SF6 Breaker & Remote Control Panel including dismantling of operating mechanism parts, well cleaning with petrol and replacing minor parts, reassembling of parts including well cleaning and complete panel board main bus bar, de- carbonizing all joints bus bar CT, PT, spouts metal parts and making breaker perfect operation in manual and electric mode including all routine and preventive maintenance complete all as specified and directed. Note : The Spare parts required will be measured and paid separately.
Dismantling of old unserviceable Power Back Up System & Supply, Testing, Commissioning Ripple Free Power Supply Unit with First Stage conversion : Power Factor Correction along with H.F. filter and input AC Voltage Rectification and conversion in high voltage DC. ii) Second Stage Conversion: Rectified high voltage DC is stored in capacitors. High voltage DC is then converted in to a very high frequency AC (20 KHz and higher). Conversion of high voltage DC to high frequency AC is achieved by means of very powerful and ultra-fast semi-conductor switching devices. High frequency AC is stepped down to the required level by means of a small high frequency transformer with following specifications OUTPUT POWER FACTOR –O.8 LAG. OUTPUT FREQUENCY – 50 HZ+/-0.5% . WAVE FORM – 20 MILLI SEC PURE SINE WAVE . RESPONSE TRANSIENT - <8% ON 90% LOAD CREST FACTOR – 3:1 . DISPLAY – SUPPLY ON, BATTERY HIGH / LOW, OVERLOAD, OUTPUT HIGH / LOW, CHARGING ON, MAINS LOW / HIGH, BYE-PASS, FAULT, OVERHEAT PROTECTION - OUTPUT OVER-VOLTAGE, OUTPUT UNDER VOLTAGE, OVERLOAD, SHORT CIRCUIT OVERLOAD CAPACITY- 110% - 08 MIN, 125%- 90 SEC, 150%- 45 SEC LIQUID CRYSTAL DISPLAY - INPUT VOLTAGE / FREQUENCY. OUTPUT VOLTAGE / FREQUENCY, LOAD %, CHARGING CURRENT, TRANSFER TIME / SWITCHING TIME - 0 MILLI SEC SWITCHING MODE – WITHOUT ANY SWITCH GEAR HUMIDITY – 5% T0 95% NON CONDENSED. Stepped down AC is rectified by ultra-high-speed diodes to DC of desired voltage and filtered by means of high frequency filters and pure DC voltage is stored in capacitors complete all as specified and as directed. Make : ABB / Schneider / Siemens as approved by GE minimum ISO 9001:2015 Certified. Note : The Entire work at site is to be executed only by OEM approved by GE.
Dismantling of old AC to DC Converter with multiple output ports on line and replacing with new Digital Converter Power Supply Unit Switch Mode Power Supply Unit Voltage influence ≤0.5% / V Temperature influence: ≤0.01% / °C Ambient conditions Ambient temperature : -25 to +55°C Storage Temperature : -25° to +70°C Transport Temperature : -25° to +70°C Relative Humidity : 15% to 85% Double Conversion On Line. • Continuous Voltage & Frequency Regulation • High Power Density • Wide Input Voltage Range • Input Supply voltage 360- 450 volts Three Phase Input Frequency Regulation Range, AC Input 47-55 Hz Supply Voltage Fail. Bridging Time at 100 % Load 10 ms min. Max. Deviation of Output with Static Load Change ± 2.5 % Max. deviation of Output with dyn. Load change 5 % (Load Change 10-90 %) Short-Circuit Protection Over-Current Switch-Off with Automatic Restart Overload Protection Over-Temperature and Overcurrent Switch-Off Reset after Thermal Overload Switch-Off disconnection of AC Input voltage 30 s min. Standards Isolation testing 2.5 kV AC Routine Test, Overvoltage Category, Degree of Pollution Electromagnetic Compatibility Input Current Harmonics No Limitation Efficiency at nom. Load Approx. 79-84 % Indication of Operational States Green LED, Output Voltage OK Operating Temperature 0°C ... +55 °C Storage Temperature -25 °C ... +75 °C
Disconnecting of existing old Battery Bank Set with User Replaceable, Batteries type SMF Back Up not Less than 01 Hour at full Load considering KW Output Power (a) Open Circuit Voltage (b) Full Load Voltage (c) Full Load Current (d) Current Resolution (e) Mode of Operation 360V DC 15 A (Current should be adjustable from 0.1A to 15A with resolution of 1A) 1 A Constant Current (Independent of the Load Voltage) mode Cooling Water Temperature, Water Flow (if water cooling is used) (b) Stack Temperature (c) Over Voltage (d) Over Current (e) Single Phasing (f) Emergency Off (g) Panel Door All Sensors NO/NC input will be provided by IPR for Interlock purpose except Over-Voltage, Over Current, Single Phasing, Emergency Off and Panel Door Interlocks. All functioning of these Interlocks using Dummy Inputs of 0 to 5 V /NO /NC as applicable. The interlocks operation should be implemented using PLC (Programmable Logic Control) and HMI (Human Machine Interface). Calibration certificate of all sensors and meters in the power supply unit will have to be submitted along with the delivery of the power supply.
Dismantling of old Battery Bank and Supply and Fixing of in Replacement of Battery Backup 360 Volts 26 AH system with relays AC & DC operatable with extra relaying schemes attached to the equipment including part of the network with their own relaying system. Equipped with Backup relay’s to operate in any failure of Tripping of Circuit Breaker due to main relays capable to sustain Mechanical defect of moving parts of the main relay, Failure of DC Power Supply to the relay, Failure of Tripping pulse to the contactor / MCCB from Relay, Failure of Current or Voltage to the Relay from CT or PT circuits etc. Equipeed with another line of protection as back up relaying. essentially have everything separate from main relaying scheme. just because backup relay must not fail to operate in the event of failure of main relays. in spite disconnect main relays from the system for preventive maintenance or trouble shootings. Because of presence of backup relays, no interruption has to take place for 11 KV equipment or circuit. During this time back up protection scheme takes care of the protection of the system. As the back relaying is second line of protection it must be slow in action than main relay so that it can only be operated when the main relaying scheme of the system/equipment fails. Make : Seimens / ABB or Minimum ISO 9001:2015 certified approved by GE
Dismantling of old damaged fuse kit kat and replacement with new MFM Ethernet / RS-485 Modbus Gateways for communication with MODBUS compatible devices via Internet (WAN) and Intranet (LAN). Used for computer communication between devices and RS-485 / USB Converter. GPRS/Modbus Gateways (modems) enable access to devices that communicates with Modbus protocol over GPRS or Ethernet network. • Set the parameters, save a copy in a file and retrieve it in case of need (the file can be sent via email as well) • See active user alarms. Operational characteristics – Auxiliary supply voltage range: 100-440 / VAC 120-250VDC – Voltage measurement range: 50-720VAC – Usage in medium and high-voltage systems with voltage transformers – Rated input current: 1A or 5A – Frequency measurement range: 45-66Hz – True measurements: for voltage and RMS current – Measurement accuracy: • Voltage: ±0.5% (50-720 ) VAC • Current: ±0.5% (0.1-1.1In) • Power: ±1% F.S. • Frequency: ±0.05% • Active energy: Classe 1 ( / 62053-22) IEC EN • Reactive energy: Class 2 ( / 62053-23) distribution system capable distribution system with following specification :- (a) Wireless Modem Specifications • GPRS/Edge modem o Max Power Input : < 1 W o RF Output Power Levels o Max : 33dbm (+/-) 2db o Receiver Sensitivity : < -106 dbm o Avg power consumption(sending data every 1 minute) : < 1 W o Voltage range : 70V to 300V o Normal operation temperature: -20 °C to +55 °C o bands : Quad Band o Ports : RS485, RS232 (b) CE Certified GPRS/ Edge Modem o Dual-Band GSM/GPRS 900/ 1800 MHz o 3V3 & 5V interface for direct communication with MCU kit o Configurable Baud Rate o SMA connector with GSMAntenna. o SIMCard holder. o Built in Network Status LED o Inbuilt Powerful TCP/IP protocol stack for internet data transfer over GPRS. o GPRS mobile station class B o Compliant to GSM phase 2/2+ – Class 4 (2W@ 900 MHz) – Class 1 (1W@ 1800MHz) o Control via AT commands (GSM07.07 ,07.05 and SIMCOMenhanced AT Commands) (c) Micro-Controller o Type - MSP430 5F4194 o Hardware Multiplier Supporting 32-Bit Operations o Serial Onboard Programming, No External Programming Voltage Needed o Three-Channel Internal DMA o Basic TimerWith Real-Time Clock Feature o 12-Bit Analog-to-Digital Converter (ADC ) o Up to Four Universal Serial Communication Interfaces
There should be provision to generate reports based on current day, for a particular day and for a period where he should be able to choose the start date and end date. Reports should also present graphs where applicable and provide export in form of Excel or Word to the Engineer - in - Charge by the contractor. (l) Location report The User should be able to view the report of a single location as well as a group of sub-location over the specified period. He should be able to view the report in form of a Graph, and tabular form. • Sub-Location Report : The User should be able to view the report of a single sub-location as well as for a number of devices in the same, over the specified period. He should be able to view the report in form of a Graph, and tabular form. • Export Reports in Excel / CSV format. • Online display of Graphical Charts for various electrical parameters. • Define group of IEMUs meters based on locations • Define the reports on Cumulative kWh, and Running Hours, etc. • Define Reports on the basis of Quality of Power supply like Voltage Imbalance, Current Imbalance, Voltage Fluctuations etc. The Web Based Application Software and Services should generate Alarms and send Alerts over SMS messages to mobile users and emails for the conditions, such as: • Voltage in any Phase goes above 11800 V with value of voltage • Voltage in any Phase goes below 9000V with value of voltage • Power factor of any Phase is less than 0.85 with Value of Power Factor • Any Deviation from Benchmark Value of Active Power, apparent power and reactive power. • Incoming power supply not available. • Ability to suppress the alerts during specified time period in a day. Note: SMS to User should be strictly through Central Server (CS) and No User shall be able to receive SMS directly from the Intelligent Field Device due to security concerns. SMS must be delivered to client up to 05 Years from date of installation Key Technology Criteria: • The System should be accessible anywhere through web but with a secured password protection and no software or hardware required to be installed for viewing the data on web
• The software and server should be maintained by the contractor, without cost implication, and there should not be any requirement of deploying IT hardware and software. • The web application shall be hosted on Tier-III certified data center MAKE : SIEMENS / SCHNIDER / ABB approved by GE minimum ISO 9001:2015 Certified . Note : The Entire work at site is to be executed only by OEM approved by GE
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
PARAMOUNT INDUSTRIES
Bidder Name
proach associates
PARAMOUNT INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .