Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.4 LAccepted-AOC | 1 | Accepted-AOC Allotted | |
| 2 | 2₹24.8 L+₹1.4 L (5.95%)Rejected-Finance HOUSE NO 254P SECTOR 6 ROHTAK OPPOSITE RAJIV GANDHI STADIUM VPO MAKRUALI KALAN 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | 2 | Rejected-Finance not lowest | |
| 3 | 3₹25.0 L+₹1.6 L (6.95%)Rejected-Finance | 3 | Rejected-Finance not lowest | |
| 4 | 4₹26.3 L+₹2.9 L (12.5%)Rejected-Finance | 4 | Rejected-Finance not lowest |
Tender Value
₹23.9 L
EMD Value
₹48,000
Closing Date
6 Feb 2020, 5:00 pmClosed
Executive Engineer Provn Divin PWD BandR Jind
Executive Engineer Provn Divin PWD BandR Jind
Construction of Extension of Library in Govt College at Jind in Jind Distt
2020_HRY_115519_1
PWD/Jind/Extension of Library in Govt. College
Open Tender
Civil Works
Works
182 days
Jind
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer Provn Divin PWD BandR Jind
₹48,000
Yes
Executive Engineer Provn Divin PWD BandR Jind
20 Mar 2020
17 Jan 2020
7 Feb 2020
17 Jan 2020
6 Feb 2020
17 Jan 2020
21 Jan 2020
Amount
Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing - (b) in cement (HSR 8.5) (b)
Dismantling Concrete - (e) reinforced cement concrete with cleaning and straightening and cutting of bars if required. (HSR 8.6) (e)
Dismantling Roofing - (b) second class mud roofing with brick tiles, precast C.C. tiles or stone slabs (HSR 8.8) (b)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 meters above plinth level (HSR 11.7) Second Storey
Masonary work using flyash-lime based bricks (IS:12894-2002) laid in cement sand mortar 1:6 in super structure. (HSR 11.102). Second Storey Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position complete in all respects. (HSR 10.86 + 10.95 (a)) Second Storey
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects. (HSR 10.82 + 10.95 (a) Second Storey
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in fascias parapets and other thin vertical sections, not covered by item nos. 10.82, 10.86 to 10.88 not exceeding 10 cm thickness excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects. (HSR 10.89+10.95(a)) Second Storey
Third storeyTerrace
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and an other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 Kg per sqm ontop of R.C.C. slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13) Second Storey
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50) Second Storey
Supplying & fixing in position G.I pipe class 'B' spouts in chajjas and cantilevers. (HSR 13.55 (e) 50mm i/d G.I. pipe
Cement concrete 1:2:4 gola 10 cm x 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64) Second Storey
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (a) 100 mm dia PVC pipe 6 kg. pressure (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.89](a). Second Storey Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Providing and fixing PVC Bend ISI Mark. (a) 100 mm dia PVC Bend (Note:- Reputed make PVC Bend such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.90](a). Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Providing and fixing False Ceiling without grooves with 12mm to 15mm thick, 600mm x 600mm best quality mineral fibre titles of approved make fixed on M.S. Steel runners frame i/c cost of screws angles, cleats, rawel plugs, with taping and painting etc. complete in all respects as approved by the Engineer- In-Charge. (HSR 13.92) First storey
Second Storey
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4) First Floor
Kotah stone flooring minimum 25 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62). First floor Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pins etc. (HSR 14.66). First floor Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
Plastering on walls 10 mm thick cement plaster 1:3 (HSR 15.2) Second Storey
Third storey/Terrace
Plastering on walls 12 mm thick cement plaster 1:4 (HSR 15.5) Second Storey
Plastering on wall 12 mm thick cement plaster 1:6 (HSR 15.7) Second Storey
Plastering on walls 15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12) Internal Plaster Second Storey
10 mm thick cement plaster 1:4 under side of ceiling (HSR. 15.52) First floor
Preparation of ply wood surface for painting inlcuding sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2).
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3).
Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9).
Painting two coats excluding priming coat with ready mixed paint for matelic sufraces in all shades on new steel or iron work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.17).
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58).
Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81)
Cost of aluminium fittings complete for doors and windows, such as tower bolts, handles, etc. and screws for these fittings (excluding sliding bolt) For single leaf shutter (HSR 17.72 a)
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ, chikrassy & chaplash etc. (non-coniferous timber other than teak, conforming to I.S specification no. 1003, Kiln-seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screws, chocks/cleats, stops, nails etc. complete, fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) - (b) 35 mm thick. (HSR. 17.90(b)) - Note I under 17.18
Factory manufactured wire gauze door and window shutters of commercial hard wood such as hollock, champ, chikrassy annd chaplash, etc. (non coniferous timber other teak conforming to I.S specification no. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) (i) 30 mm thick (HSR 17.92 (i) - Note I under 17.18
Wrought iron and mild steel (using angles, flats, square bars, tees and channels), ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Fe-500 EQR TMT steel bars for RCC works, where not including in the complete rate of RCC including bending, binding and placing in position complete. (HSR 18.22). Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS:1732.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Supplying and fixing Glass panes including special metal sash putty of approved make. (b) glass panes 4 mm thic, exceeding 40 sq. dm areas. [HSR 18.30 (b)].
Pressed steel sheet frames (chowkhats) consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts) iron hinges, conforming to P.W.D specifications, including bolts for fixing stops, lock notch, provision for receiving tower bolts, and finished with one coat of ready mixed paint red lead non-setting primer of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lungs complete. (HSR 18.34 ) (c ) Door and window frame of size 127 mm x 50 mm with 40 mm wide double rebate. First storey
Recovery Brick @ 4.50/- each
Brick Bats @ 450/- cum
Anil Kumar
Aman Kumar
The Sant Nagar Co-op L&C Society Ltd. Distt. Jind
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .