Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 CrAccepted-AOC 156 INDIRA COMMERCIAL RESIDENTIAL COMPLEX TRANSPORT NAGAR KORBA DIST KORBA CG 495677 | KORBA | CHHATTISGARH | 495677 | ₹40.3 Cr | L1 | Accepted-AOC work awarded to techno commercially eligible L-1 Bidder |
| 2 | L2₹41.6 CrRejected-Finance | ₹41.6 Cr | L2 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER |
| 3 | Rejected-Technical CHENNAI TAMIL NADU 600032 INDIA | CHENNAI | TAMIL NADU | 600032 | - | - | Rejected-Technical REJECTED DUE TO NON COMPLIANCE OF WORKING CAPITAL CRITERIA AS PER NIT |
| 4 | Rejected-Technical INDURE HOUSE NEAR SAVITRI CINEMA GREATER KAILASH II GREATER KAILASH II SOUTH DELHI DELHI 110048 | SOUTH DELHI | DELHI | 110048 | - | - | Rejected-Technical REJECTED DUE TO NON COMPLIANCE OF LEGAL STATUS AS PER NIT |
Tender Value
₹39.5 Cr
EMD Value
₹49.4 L
Closing Date
20 Jun 2024, 5:00 pmClosed
GM(EnM)/HOD CCL
Alakhnanda Building 1 st Floor ,Office of GM(EnM)/HOD, CCL Darbhanga House Ranchi
Planning, Design and Commissioning of ALTERNATE ARRANGEMENT FOR TRANSFERRING COAL FROM MAGADH OCP TO NTPC CONVEYOR 10 MTY,at MAGADH OCP WITH all civil,Electrical and Mech.Works on turnkey basis and Operation AND Maintenance of plant for five years
2024_CCL_308319_1
GM(ENM)/E-TENDER/24/778 DATED 17.05.2024
Open Tender
Miscellaneous Works
2005 days
MAGADH OCP of CCL located at Distt. Chatra (JH)
AS PER NIT
7 documents required · 7 mandatory
₹49.4 L
OFFICE OF GM(EnM)HOD CCL
24 Sept 2024
17 May 2024
21 Jun 2024
18 May 2024
20 Jun 2024
22 May 2024
22 May 2024 - 13 Jun 2024
21 May 2024
Amount
A. WORK & SERVICES
Detailed survey of the area, within the battery limits & submission of reports (Complete work as per Tender document)
Sub soil exploration, field and laboratory testing of samples & submission of reports (Complete work as per Tender document)
Design Engineering Cost
Preparation and submission of system engineering drawings as per system requirements.
GA & detail engineering designs and drawings of all civil and structurals included in the system and scope of works (Complete details of the system)
G.A. & detailed engineering designs and drawings including working and maintenance manuals of (Complete details of the system) : i) all individual equipment ( Mechanical & Electricals) ii) Dust Control & Pressurisation system. iii) Fire-fighting and plant cleaning system. iv) Chutes & Liners v) Communication system vi) Power Supply System vii) Illumination system. viii) Plant control system ix) Any other system/unit to match the scope of work & requirement
Documentation as per tender specification, complete as per scope of works
B. CIVIL, STRUCTURAL, INFRASTRUCTURAL AND DEVELOPMENT WORK
Receiving Pit Complex including receiving hoppers, platform, ramp and retaining walls
Conveyor Gantry/Gallery with supporting structures
Transfer Houses, Drive Houses
Switching room
Internal approach roads, drains and culverts
Water supply arrangement: Ground water reservoir, water supply pipeline, pump houses.
Sewerage system & ETP
Lighting Mast
Site Development, Arboriculture & Miscellaneous Items required to complete the work as per NIT
C. PLANT & MACHINERY ( SUPPLY)
C.(a) SUPPLY : MECHANICAL
CONVEYORS
BELTING
EQUIPMEMT
Mechanical Equipment Receiving Pit & Bunker
Mechanical Equipment at Transfer houses
Other mechanical equipment
Dust suppression system with piping & other accessories. Condition monitoring system, Safety & firefighting system, Plant cleaning, drinkng water , and other misc. equipment/utility for any more item required to complete the project
C.(b) SUPPLY : ELECTRICAL
Major Electrical Equipment in Switchroom (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
i) 415 V sectionalized Motor Control Centre (MCC) at substation A comprising of 2 nos. of Incomer ACBs, 1 no. of Bus-Coupler ACB and required nos. of SFUs, MCCBs, MCBs for supply of power to LT equipment like Vibro feeder, Electrical Hoist, Metal detector & Magnetic separator, Dust Suppression/ Extraction, Fire fighting system, Conveyor Brake, Flap gates etc. complete with metering and protection system- 1 No. ii)Lighting Transformer 63 kVA, 415 V/230 V (L-L)- 1 No..
PLC-SCADA (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
PLC-SCADA system, Condition Monitoring System, Local Control Station, Fault Annunciation System, hard wiring, integration of the PLC-SCADA system of Alternate Arrangement with the PLC-SCADA system of the NTPC Conveyor System. Other parameters as defined in Scope.
Cables (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
A.Power cables: i)3.3 kV grade, XLPE, three core, armoured Copper conductor, FRLS cables of different sizes for supply of power to Conveyor Drive C1 from 3.3 kV VCP at “NTPC Conveyor System” substation as per technical specification. ii)1.1kV grade, PVC insulated, PVC sheathed single wire armoured copper conductor FRLS cables of different sizes for power supply to 415 V Switchboard panel to be stationed at Switch-room from 415 V Switchboard at “NTPC Conveyor System” substation and from 415 V Switchboard panel to be stationed at Switch-room to other LT equipment as per technical specification. B.Lighting cables: i)1100/660 V grade, PVC insulated, PVC sheathed, single wire armoured, Copper conductor, FRLS cables of different sizes as per technical specification. C.Control and Signalling cables: 1100/660 V grade, single/multi core PVC insulated and sheathed, Copper conductor, FRLS, control and signalling cables of 2.5 sq. mm cross-section having different no. of cores as per technical specification. D.Cable trays/cable racks Cable trays/cable racks (separate trays shall be used for power and control cables), cable trenches & cable vaults etc as per technical specification
Illumination system(Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
A.230 V (L-L) Main Lighting Distribution Board with incoming MCCB and outgoings MCCBs/MCBs as per technical specification B.Lighting Distribution Boards with incoming and outgoing MCCBs / MCBs as per technical specification C.Luminaires: i) Supply of distribution boards, luminaries, ceiling fans, exhaust fans etc. including junction boxes, conduits, switches sockets etc. for indoor illumination as follows: a) For Switch room 1) The illumination system must be designed to ensure minimum illumination lux level of 100 Horizontal and 50 Vertical inside the substation building (Control room). 2) Ceiling fan, 48" sweep-Required Nos. b) Exhaust Fan Battery room - 2 no 12" sweep Toilet - 1 no 9" sweep ii)11 m high steel tubular poles along with LED street light luminaries of required wattage with min. 100 lumen/watt along with control gear, brackets etc for service road lighting and general area lighting. iii)8 Nos. of LED flood light luminaries of required wattage with min. 100 lumen/watt along with control gears, brackets etc. with 18 m high tower iv)Inverter cum battery charger along with battery for emergency lighting suitable for operation at 230V AC inside substation building v)Miscellaneous items like junction boxes complete with fuse, terminal block and other necessary accessories, cable glands, lugs, conduits, receptacles etc
Welding System (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
i)Transformer welding set 400 A complete with cables and accessories-2 Nos. ii)1.1kV grade, PVC insulated and sheathed single layer armoured, FRLS, Aluminium conductor cables for power supply to welding sockets. iii)Dust proof plug sockets complete with switches, holder set etc throughout the plant-Lot
Earthing System & Lightning Protection System (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
i. Earthing system (Safe Earth Electrode type) including earth pits, required galvanised strips/flats for inter connection etc.- Lot. ii. Lightning protection system consisting of spikes, earth pits, galvanised strips /flats etc.-Lot
Communication system (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
i. Project administrative communication system complete with automatic pushbutton type telephone sets at various strategic locations such as Receiving Pit- Traffic Control Room-1 No.,Vibro Feeder Floor. - 1 No.,Receiving Pit Switch room- 1No. , Transfer House- 1 No., Conveyor Gantary- 1 No. etc. including wiring of all sets up to a common junction box and connected to main auto exchange for external connection - lot ii. Visual communication system with industrial type CCTV- lot
Miscellaneous Equipment comprising of the follwing (Refer Section 4.4, Part-II of Vol-II/Sec-7.3 & Annexure-III.2 of Vol-II/Sec-7.3 & Tender Drawings)
i. Water cooler with water purifier- 2 Nos.(min.) at suitable Locations. ii. Miscellaneous items such as Local control, stations, testing equipment, electrical portable fire fighting equipment for Switch-room and other safety equipment as per relevant Indian Standard & CEA Guidelines. Furniture for Switchroom building.-Lot iii. Exhaust and ceiling fans - lot iv. Insulating mats per IS for sub-stations, MCC rooms and control rooms - lot v. Air conditioners 1.5/2 Ton Capacity - lot vi. Mandatory Spares electrical installation-Lot vii. Testing equipment electrical system-Lot
Any other equipment specifically not mentioned but necessary for efficient operation of plant under this package- lot
C1. ERECTION, INSTALLATION & COMMISSIONING
Erection of mechanical equipment
Erection of electrical equipment
Trial run, and commissioning of the plant
C2 . OTHERS ITEM
Any other item left out for completion of the project
C3 . MAINTENANCE AND TRAINING
Operation of the plant for five year after commissiong
Maintenance of the plant for five year after commissiong
Training of the employer personnel as per tender document
Total impact of GST for the purpose of CTC
ARDEE ENGINEERING PRIVATE LIMITED
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid