Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
24 Mar 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TELECOM
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- 1.Work of LED type Display Boards supplied & installed and operation through microprocessor/PC based system. OR 2. Work of Coach Guidance system in which LEDs used to display coach number/Coach Position or related information and operation through Microprocessor/PC based system. OR 3. Supply, installation, testing and commissioning of display of train information on LED based Display Boards i.e. Single or Multiline at a glance or PC based announcement system for train information to passengers. O R 4. AMC of Microprocessor/PC controlled LED based train display board/Coach Guidance System/Single or Multiline Display Boards/PC based Announcement system. NOTE A1: For the following equipment's a. SDH/STM/PDMUX/IPMPLS/VOIP b. Control equipment c. ISDN/IP based exchange d. CCTV/Video surveillance system e. Integrated security s y s t e m f. Networking equipment g. Train information display board/Coach guidance system/IPIS/GPS CLOCKS h. Secured communication system at level crossing gates i. VSAT j. MTRC 1. The equipment shall be procured from: a) If there is any RDSO approved source, then the equipment to be procured from the RDSO approved source or its authorized dealer/distributor. b) If there is no RDSO approved source but there is TEC approved source, then the equipment to be procured from the TEC approved source or its authorized dealer/ distributor. c) If there is no RDSO or TEC approved source then the equipment to be procured from the OEM or its authorized dealer/ distributor. 2. Make, Model Specification of the offered equipment along with OEM authorization if the tenderer is other than OEM shall be submitted along with the tender. 3. MOU with RDSO approved Source or TEC approved source or the OEM, covering Supply, installation, testing, commissioning of system including after sales support required during warranty period shall be submitted along with the tender.
26 conditions · 15 needing a document upload
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Augmentation of IPIS (CGDB, TIB along with GPS clocks) at Shahganj & Restoration of IPIS (CGDB, TIB along with GPS clocks) at Shahganj & Akbarpur Railway station of Lucknow Division, Northern Railway.
106-Tele_Tender_30_25-26
106-Tele_Tender_30_25-26
Open
Works - General
270 Days
Lucknow, Uttar Pradesh
₹0
₹2.1 L
24 Mar 2026
3 Mar 2026
10 Mar 2026
102 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,27,63,269.69 | ||
| — | 1.00 | — | — | ||
| "Supply of Central Data Controller Unit conforming to system requrement as per RDSO Spec.. RDSO/SPN/TC/108/2019 Rev. 1.0 or latest. The control cosole shall have main and standby CP to work in standby mode, one Nos. of 1 KVA UPS with two independent batteries, two LCD monitor (19 inch), CCU Rack, KVM Switch, CDS (Layer-3 Swtich of make CISCO, HP, Juniper, Brocade, Avaya, Extreme, Netgear, D-link or similar) and other accessories, housed in a standard size cabinet along with driving Software for integrated passenger information system as per RDSO Specification No. RDSO/SPN/TC/108/2019 REV.1.0 or latest. This includes supply and isntallation of SW for Announcement system with necessary interface and announcement recording (Hindi/English/ fresh studio copy of voice files.) as per RDSO Specification No. RDSO/SPN/TC/108/2019 REV.1.0 or latest ( the same to be interfaced with existing audio and video system insatalled at the station.). The software should support all types of display/announcement by merely adding necessary hardware in future ( single/multiline arrival/departure train information display boards. (single sided/double sided), CGDB, AGDB, LCD/LED/Plasma TVs etc. INSPECTION: RDSO" | — | — | — | 4,83,919.98 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of CDC set as per RDSO Specification No. RDSO/SPN/TC/108/2019 Rev.1.0 or latest as supplied above. | — | — | — | 13,929.45 | |
| — | 1.00 | — | — | ||
| "Supply of RMS server as perRDSO/SPN/TC/108/2019(Ver.0.0 ) or latest. INSPECTION: RDSO" | — | — | — | 1,43,850 | |
| — | 1.00 | — | — | ||
| Complete wiring, testing, integration and commissioning of IPIS system as per scope of work. This shall includes all connecting cables, connectors etc. | — | — | — | 5,217.47 | |
| — | 3.00 | — | — | ||
| "Supply of Platform Data Controller (PDC) conforming to System requirement of RDSO Spec.. RDSO/SPN/TC/108/2019 Rev1.0. or latest. It consists of 8 Ethernet port and 8 serial port for field device and 2 SFP optical port to connectivity with CDC. Optical ports are used whether the distance between PDC & CDC is more than 80 meter as per Set as per RDSO Spec.. RDSO/SPN/TC/61/2015 Rev 4.0.Amd.1 or latest. INSPECTION: RDSO" | — | — | — | 2,07,449.88 | |
| — | 3.00 | — | — | ||
| Installation, testing and commissioning of PDC as per RDSO Specification No. RDSO/SPN/TC/108/2019 Rev.1.0 or latest or latest as supplied above. | — | — | — | 10,522.83 | |
| — | 2.00 | — | — | ||
| "Supply, Installation , testing &commissioning of double face Four Line Coach Position Train formation At a Glance Display Board(AGDB) as per RDSO spec no:-RDSO/SPN/TC/108/ 2019(Rev-0.0) orlatest INSPECTION: RDSO FOR SUPPLY PORTION" | — | — | — | 5,31,562.98 | |
| — | 1.00 | — | — | ||
| "Supply of LED based Mono color Multi lineDisplay Board (MLDB) of 5 Lines TrainArrival/Departure Display Board singleface with all necessary accessories as perRDSO/SPN/TC/108/2019 Ver 0.0 Amdt. 1. INSPECTION: RDSO" | — | — | — | 7,97,173.18 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning ofLED based Mono color Multi line DisplayBoard (MLDB) of 5 Lines TrainArrival/Departure Display Board singleface with all necessary accessories | — | — | — | 38,122.65 | |
| — | 2.00 | — | — | ||
| "Supply, installation, testing and commissioning of Media Converter fiber to Ethernet 100 base T Signal mode fiber with all required accessories including AC 230 V to DC Power adapter, as per Clause No. 16 of RDSO Spec. RDSO/SPN/TC/65/2016 (Rev.4.0) or latEST INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 11,481.64 | |
| — | 78.00 | — | — | ||
| "Supply, Installation,Testing and Commissioning of Double Faced Coach Guidance Display Boards as per RDSO Specification No. RDSO/SPN/TC/108/2019 or latest as per specification. It includes supply of GI pipes required for installation of CGDB system. INSPECTION: RDSO FOR SUPPLY PORTION" | — | — | — | 31,97,220 | |
| — | 58.00 | — | — | ||
| Installation & Commissioning of double face coach guidance display boards as inopen area. It includes Supply, hanging & Fixing arrangement of coach indication board along with hood (Cover shed) in open space, (without shed area) 100 mm dia (OD) & 15 feet'slong G.I. to be erected with concrete foundation (1:3:6) of 3 Feet deep from platform level and on the pipe, an angle to be fixed on G.I. pipe as per site condition.Contractor to supply all required materials with G.I. pipe& G.I. sheet of 2'x3' which should be placed on the top of the board in open space as per approval of site engineer with angle fastening and crow guard. (supply of G.I. pipe included in this) | — | — | — | 3,49,276.58 | |
| — | 22.00 | — | — | ||
| Installation & commissioning ofDouble Faced Coach GuidanceDisplay Boardsin shade areaThis includes all requiredaccessories required includinghanging structure for fixingarrangements tocommissioning the item. as perRDSO/SPN/TC/108/2019 Ver1.0 or latest with latestAmendment | — | — | — | 66,740.74 | |
| — | 124.00 | — | — | ||
| Repairing and testing of defective Coach Indication Boards (double faced) CIB. All required materials to be supplied by Contractor. | — | — | — | 4,56,517.16 | |
| — | 10.00 | — | — | ||
| Repairing and testing of Double faced/ Single Faced GPS Platform Clocks. All required materials to be supplied by Contractor. | — | — | — | 86,737.8 | |
| — | 2.00 | — | — | ||
| Repairing and testing of defective PDCH. All required materials to be supplied by Contractor. | — | — | — | 30,680 | |
| — | 5000.00 | — | — | ||
| "Supply of screened 5 pair (10 core) color coded & twistedData Communication Cable, each core made of CopperConductor of 0.50mm diameter(7/0.20mm) ABC(Annealed Bare Copper) & Polyethylene Insulated havingcore outer diameter 1.3mm (wall thickness 0.25mm),such 2 core twisted in a pair and such 5 pair laid up &polyester taped, 0.6 mm ATC (Annealed Tinned Copper)Drain Wire, overlapped with Aluminium Foil forscreening/shielded, polyester tape, grey color PVC outersheath of wall thickness 1.3mm should be provided forthe data communication wherever required. Tolerance indimensions should be within ± 10. INSPECTION: CONSIGNEE" | — | — | — | 2,27,550 | |
| — | 5830.00 | — | — | ||
| "Supply of STP (Shielded Twisted Pair)CAT 6 Cable as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. INSPECTION: CONSIGNEE" | — | — | — | 1,97,811.9 | |
| — | 9500.00 | — | — | ||
| "Supply of 3 Core x 2.5 Sq mm multi strand copper conductor, PVC insulated, armoured power cable confirming to IS:1554 partI as per RDSO specification No. RDSO/SPN/TC/65/2021 rev 6.0 or latest). Finolex/polycab/orbit/ havell or any other reputed make. INSPECTION: RITES" | — | — | — | 10,15,835 | |
| — | 3800.00 | — | — | ||
| "Supply OFC single mode 6 fiber armouredcable Specification No. IRS:TC55-2006 Rev.1 or latest of make finolex/Polycab/Paramount. INSPECTION: CONSIGNEE" | — | — | — | 1,22,436 | |
| — | 6000.00 | — | — | ||
| "Supply of PVC conduit pipe (minimum 25 mm dia./1.55 mm thick, 3 metre long and ISI brand) with flexible pipes fixing /laying materials and all other accessories as per requirement. INSPECTION: CONSIGNEE" | — | — | — | 1,48,980 | |
| Laying of OFC/Power cable/CAT-6 cable PA Cable/Data cable and all the other types of telecom cable and all the other types of telecom cable through HDPE pipe/casing capping/fall ceiling with laying/fixing of HDPE pipe/casing capping/uPVC pipe for connecting/interfacing variouys cpmponents and system integration. All materials for jointing and termnaition of power cable/CAT-6 cable as per site requirement are to be supplied by contractor. This item also includes supply of RJ- 45 connector with cap for terminating CAT-6 cable and supply and installation of power board with 4 points (3 nos 5 amp sockets and 1 nos 15 Amps socket) as per site requirement. | — | — | — | 6,35,101.6 | |
| — | 4.00 | — | — | ||
| "Supply of 12 port loaded LIU rack mountable, LIU shouldbe provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a splice cover for Pigtail Splicing. Cable glands shall be provided for secure anchoring of incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. INSPECTION: CONSIGNEE" | — | — | — | 14,800.32 | |
| — | 28.00 | — | — | ||
| Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. | — | — | — | 19,135.48 | |
| — | 4.00 | — | — | ||
| "Supply and installation of 9U, 19 inch rack for pole mount/ wall mount with Fan 230VAC 90CFM-02 Nos., AC distribution box (5 socket of 5A, Power On LED indicator, MCB)- 01 No., Shelf Cantilever 1U: 01 No. Cable Manager 1U:01 No. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 48,377.24 | |
| — | 5050.00 | — | — | ||
| Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. | — | — | — | 7,49,874.5 | |
| "Supply of 40 mm outer dia. PLB HDPE duct as per RDSO Spec. No. RDSO/SPN/TC/45/2013, Rev 2.0 or latest with all accessories (like couplers, bends etc). INSPECTION: RITES" | — | — | — | 9,09,120 | |
| Laying of PLB HDPE pipe in trench/open space, fixing and clamping of HDPE pipe on wall or structure and sealing of the duct after laying with proper fixing material. All the accessories like couplers, end caps/plugs to be provided by the contractor within the same cost and its protective work as per direction of site engineer. | — | — | — | 1,53,440 | |
| — | 2.00 | — | — | ||
| "Supply, installation, testing, wiring & commissioning of Layer-2 managed Switch (24 ports 10/100/1000 BASE-Tports, 4x 1G SFP+ ports) as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 orlatest make HP/Cisco/Juniper or other reputed make with similar or better specs. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 52,520.3 | |
| — | 3.00 | — | — | ||
| "Supply & installation of PA amplifier (Dual Zone model TZA - 4000EM Ahuja make or similar) . This includes all required fittings and wiring material supplied by contractor at his own cost as per instruction of site engineer. INSPECTION: CONSIGNEE FOR SUUPLY PORTION" | — | — | — | 78,038.73 | |
| — | 4.00 | — | — | ||
| "Supply of PA Amplifier, 250Watt, Model SSA-250M,Make Ahuja or similar INSPECTION: CONSIGNEE" | — | — | — | 57,590.52 | |
| — | 4.00 | — | — | ||
| "Supply of 25 watts Industrial Hornspeaker with 5,10,15,20 watt tappings,matching transformer and driver unit,make reputed as LBD 8347, 8308 ofPhilips make, UHC30XT of Ahuja makeor similar. InspectionByConsigneeSupply of 25 wattsIndustrial Horn speaker with5,10,15,20 watt tappings, matchingtransformer and driver unit, makereputed as LBD 8347, 8308 of Philipsmake, UHC30XT of Ahuja make orsimilar. INSPECTION: CONSIGNEE" | — | — | — | 7,748 | |
| — | 64.00 | — | — | ||
| "Supply of 15 watts Column speaker, matching transformer and driver unit, make reputed as SCM- 15T of Ahuja make or similar. as per RDSO specification no. RDSO/SPN/TC/63/2006 Make Ahuja, Philips, Sony, AKG or similar. INSPECTION: CONSIGNEE" | — | — | — | 1,30,227.84 | |
| — | 24.00 | — | — | ||
| "Supply,Installation,Testingand Commissioning of 30Watt Horn Type Speaker with 100VLMT Taps 15, 10 and 5W complete withfixture of make Philips/Ahuja/AKG. asper technical specificationsgiven in para no.1.1.3 ofchapter-III of tenderdocument including allnecessary accessories forinstallation . INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 43,105.2 | |
| — | 2.00 | — | — | ||
| "Supply of Mike AHUJA ACM-66CH or superior mak. as per RDSO specification no. RDSO/SPN/TC/63/2006 make Ahuja, Philips, Sony, AKG or similar. INSPECTION: CONSIGNEE" | — | — | — | 2,870.84 | |
| — | 2.00 | — | — | ||
| "Supply of Gooseneck PAMicrophones model StudioMaster Flex 4 set21''Gooseneck mic with standor similar INSPECTION: CONSIGNEE" | — | — | — | 17,021.24 | |
| — | 9000.00 | — | — | ||
| "Supply, Laying, testing and Commissioning of twin core screened cable 0.9 sq. mm annealed tinned copper conductor confirming to IS-694/90.(material required for wiring is supplied by the contractor) INSPECTION: RITES FOR SUPPLY PORTION" | — | — | — | 5,04,900 | |
| — | 6.00 | — | — | ||
| "Supply, Installation,Testing & Commissioning of Platform Dual face, 4 digit, GPS synchronised digital double faced Digital platform clock as per RDSO Specification no. RDSO/SPN/TC/65/2008 Rev.3.0. Amdt1 & Amd 2 or latetst, with LED of Blue/Red/White color and size approximately 762 x 381 x 228 mm. It also includes all fitting arrangements. (color to be decided by Railways). INSPECTION: RDSO FOR SUPPLY PORTION" | — | — | — | 3,12,129.84 | |
| — | 10.00 | — | — | ||
| Installation & commissioning ofDouble side Digital Clocksuitable for platform area withGPS Synchronization instandalone mode as perinstruction of site incharge withall required accessories andfixing arrangements tocommissioning the item. | — | — | — | 47,785.9 | |
| — | 2.00 | — | — | ||
| Installation, testing and commissioning ofLED based Mono color Multi line DisplayBoard (MLDB) of 5 Lines TrainArrival/Departure Display Board singleface with all necessary accessories | — | — | — | 77,380.74 | |
| — | 1.00 | — | — | ||
| "Supply, Installation, Testing &Commissioning of 5 KVA On Line UPS with isolation transformer as per RDSO spec no. RDSO/PE/SPEC/0023-2001(rev 0.0) amnd 2.0 or latest suitable for single phase AC input & single phase AC output, floor mounted type, of make APC/Luminious/microte/liebert/Numeric idicative backup time 120 minutes. This also includes supply of one battery rack and one set (for input and output) compatible MCBs complete with cover & fixing materials. Make: Havells, Anchor or similar. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 1,53,298.57 | |
| — | 3.00 | — | — | ||
| "Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 or latest with latest amendments. Earthing kit consisting of 1. Earthing electrode of 17 mm dia 3m long - 01 No. 2. MEEB (300mm X 25mm X 6mm) - 01 No. 3. SEEB (200mm X 25mm X 6mm) - 01no. 4. Earth Enhancing compound-30-35 Kg (minimum). 5. Multistand Single core PVC insulated copper cable 35 sq mm as per IS:694 (Duplicated) used to connect MEEB to main earth electrode Min. 10 mtrs or as per site requirement. This includes:- provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data logger etc. with PVC earth wire of Size 16/25 Sq mm. through copper lugs of suitable size. PVC earth wire shall be supplied by Contractor. Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/ pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done for interconnection of two earth pits copper tape of size 25 X 2 Sq. mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Supply by RDSO approved Firm. INSPECTION: RDSO FOR SUPPLY PORTION" | — | — | — | 71,828.31 | |
| — | 50.00 | — | — | ||
| "Supply of OFC patch cord cable (10m long with APC/FC/LC-LC/FC/APC connector Patchcord). INSPECTION: CONSIGNEE" | — | — | — | 31,839.5 | |
| — | 40.00 | — | — | ||
| "Supply of SC-APC/SC-APC patch cord (1 meter) (3M, TE connectivity, R&M make or superior) INSPECTION: CONSIGNEE" | — | — | — | 3,506 | |
| — | 40.00 | — | — | ||
| "Supply of LC/PC-LC/PC patch cord (5 meter) (3M, TE connectivity, R&M make or superior) INSPECTION: CONSIGNEE" | — | — | — | 4,968 | |
| — | 40.00 | — | — | ||
| "Supply of Single Mode Patch Cord length 3 meters (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement. INSPECTION: CONSIGNEE" | — | — | — | 7,476.8 | |
| — | 1000.00 | — | — | ||
| "Supply & connecting of STP/UTP RJ 45 Connectors. Make D-Link, AMP, DAX, Legrand, Molex or Digilink or better. INSPECTION: CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 11,140 | |
| — | 36.00 | — | — | ||
| "Supply of sealed maintenance free(SMF)battery 12VDC/65AH INSPECTION: RITES" | — | — | — | 3,45,744.72 | |
| — | 2.00 | — | — | ||
| "Tools Kit for maintenance with small sizecanvas bag with following items :- 1)Combination Plier 8"", 2) Long Nose Plier(Round Nose ) 6"" , 3) Wire Striper Plier6"" , 4) Screw Driver set ( 5 Piece) , 5)Hexa with frame 12"" 6) Double Open endD spanner set (6 to 32 mm) 7)Adjustable Spanner set 8"" 8) Ball pinHammer (200 gm) , 9) Side Cutting Plier6"" 10) Soldring iron (Soldron make orsimilar) 11) Torch cell LED (3 cell)(Eveready/ Geep or similar ), 12) KroneTool (Krone make or similar) , All ToolItem 1 to 9 of Taparia/Gedor/ Jhalanimake or similar. INSPECTION: CONSIGNEE" | — | — | — | 14,532.14 | |
| — | 2.00 | — | — | ||
| "Tool Kit consisting of Optical power meter (Fiber shot 9990V),Multimeter (Fluke101), Ethernet Crimping Tool (Standard Make) Console cable (Cisco= RJ 45-DB9), Wrist ripper (Standard Make), Universal Spanner Set (Taparia),Screw Driver Set (Taparia-7Pieces set),Cutting plier(Taparia), Wire Stripper,Industrial grade USB to Serial cable, Round Cutter, Cleaver, with all accessories or Similar.. INSPECTION: CONSIGNEE" | — | — | — | 43,474.94 | |
| — | 2.00 | — | — | ||
| "Supply of Self supported aluminium step ladder (conforming of ISI) 10 ft. Height (Telescopic) INSPECTION: CONSIGNEE" | — | — | — | 15,081.92 | |
| — | 2.00 | — | — | ||
| "Supply of Transmission measuring set as per IRS TC 43/87 Make aplab or better INSPECTION: CONSIGNEE" | — | — | — | 56,195.26 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACSGCC22-231to6.pdf
ATTACHMENT
GCC Correction slip 7 to 10
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
T-30TenderDocument_1.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .