Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.6 LAccepted-AOC | L-1 | Accepted-AOC Approved by Circle Works/ purchase Committee | |
| 2 | L-2₹2.0 L+₹39,984 (25.1%)Rejected-Finance 0177 HUMANYUPUR NATH GORAKHNATH NIKAT JAGESHWARPASI CHOWK GORAKHPUR UTTAR PRADESH 273001 | GORAKHPUR | UTTAR PRADESH | 273001 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹2.0 L+₹40,598.60 (25.4%)Rejected-Finance | L-3 | Rejected-Finance L-3 |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
16 Oct 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle, Baikunthpur, Maharajganj
For the work of against sanction Estimate under Deposit Scheme
2021_PVVNV_626932_1
36/EDC(M)/2021-22
Open Tender
Electrical Works
Lump-sum
60 days
EDD-II, ANANDNAGAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer, Electy. Distn. Circle
₹2,000
19 Dec 2021
2 Oct 2021
18 Oct 2021
2 Oct 2021
16 Oct 2021
2 Oct 2021
120 days
Amount
fo|qr forj.k [k.M&f}rh;] vkuUnuxj ds vUrxZr tek ;kstuk esa Lohd`r izkDdyu la[;k 36@2020&21 ¼lj;w ugj ifj;kstuk ds vUrxZr xzke lksgjofy;k dyka] Cykd Qjsank] egjktxat esa ugj ds Åij ls 11 dsoh0 ykbZu dh f'k¶Vax dk dk;Z½ ds dk;ksZ dks djk;s tkus gsrq fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Maharajganj to work site:- ST Pole 11 Mtr. long- 02 Nos., ACSR Weasel Conductor- 0.185 Km., 11 KV Pin Insulator with Pin- 06 Nos., 11 KV Disc Insulator with disc fitting- 03 Nos., 11 KV "V" Type X-Arm- 02 Nos, Stay complete- 02 Nos., Earthing complere- 02 Nos., Guarding Angle- 02 Nos., 11 KV X-arm holding Clamp- 02 Nos., F-bracket with Nuts & Bolts- 02 Nos., Guarding Angle Clamp with Nuts & Bolts- 02 Nos. GI Wire- 22 Kg.
Erection of Single ST Pole with all fitting
Grouting of Pole
Earthing of Pole
Erection of Stay
Dismentalling of old 11 KV Line
Sagging of 11 KV Line
Stringing and sagging of ACSR Weasel Conductor
Painting of Pole
fo|qr forj.k [k.M&f}rh;] vkuUnuxj ds vUrxZr tek ;kstuk esa Lohd`r izkDdyu la[;k 05@2021&22 ¼lj;w ugj ifj;kstuk ds vUrxZr xzke dEgfj;k [kqnZa] Cykd Qjsank] egjktxat esa ugj ds Åij ls 11 dsoh0 ykbZu dh f'k¶Vax dk dk;Z½ ds dk;ksZ dks djk;s tkus gsrq fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Maharajganj to work site:- ST Pole 11 Mtr. long- 04 Nos., ACSR Weasel Conductor- 0.309 Km., 11 KV Pin Insulator with Pin- 12 Nos., 11 KV Disc Insulator with disc fitting- 06 Nos., 11 KV "V" Type X-Arm- 04 Nos, Stay complete- 04 Nos., Earthing complere- 04 Nos., Guarding Angle- 04 Nos., 11 KV X-arm holding Clamp- 04 Nos., F-bracket with Nuts & Bolts- 04 Nos., Guarding Angle Clamp with Nuts & Bolts- 04 Nos. GI Wire- 44 Kg.
Erection of Single ST Pole with all fitting
Grouting of Pole
Earthing of Pole
Erection of Stay
Dismentalling of old 11 KV Line
Sagging of 11 KV Line
Stringing and sagging of ACSR Weasel Conductor
Painting of Pole
fo|qr forj.k [k.M&f}rh;] vkuUnuxj ds vUrxZr tek ;kstuk esa Lohd`r izkDdyu la[;k 06@2021&22 ¼lj;w ugj ifj;kstuk ds vUrxZr xzke lsejkMkjha] Cykd Qjsank] egjktxat esa ugj ds Åij ls 11 dsoh0 ykbZu dh f'k¶Vax dk dk;Z½ ds dk;ksZ dks djk;s tkus gsrq fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Maharajganj to work site:- ST Pole 11 Mtr. long- 04 Nos., ACSR Weasel Conductor- 0.247 Km., 11 KV Pin Insulator with Pin- 06 Nos., 11 KV Disc Insulator with disc fitting- 03 Nos., 11 KV "V" Type X-Arm- 02 Nos, Stay complete- 04 Nos., Earthing complere- 02 Nos., Guarding Angle- 02 Nos., 11 KV X-arm holding Clamp- 02 Nos., F-bracket with Nuts & Bolts- 02 Nos., Guarding Angle Clamp with Nuts & Bolts- 02 Nos. GI Wire- 22 Kg., LT Clamp with Nuts & Bolts- 02 Nos., LT Shackle Insulator with Nuts & Bolts- 02 Nos., Nuts & Bolts for Shackle Insulator- 01 Kg.,
Erection of Single ST Pole with all fitting
Grouting of Pole
Earthing of Pole
Erection of Stay
Dismentalling of old 11 KV Line
Sagging of 11 KV Line
Stringing and sagging of ACSR Weasel Conductor
Painting of Pole
Cutting of Tree Branches
fo|qr forj.k [k.M&f}rh;] vkuUnuxj ds vUrxZr tek ;kstuk esa Lohd`r izkDdyu la[;k 07@2021&22 ¼lj;w ugj ifj;kstuk ds vUrxZr xzke cM+gjk nsohpju ls ijlk egUFk ds chp] Cykd Qjsank] egjktxat esa ugj ds Åij ls 11 dsoh0 ykbZu dh f'k¶Vax dk dk;Z½ ds dk;ksZ dks djk;s tkus gsrq fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Maharajganj to work site:- ST Pole 11 Mtr. long- 08 Nos., ACSR Dog Conductor- 0.185 Km, ACSR Weasel Conductor- 0.927 Km., 11 KV Pin Insulator with Pin- 15 Nos., 33 KV Pin Insulator with pin- 06 Nos., 11 KV Disc Insulator with disc fitting- 06 Nos., 33 KV Disc Insulator with disc fitting- 12 Nos., 11 KV "V" Type X-Arm- 05 Nos, 33 KV "V" Type X-Arm- 02 Nos, Stay complete- 08 Nos., Earthing complere- 08 Nos., 33 KV Top Channel- 02 Nos., Guarding Angle- 06 Nos., "V" Type X-arm holding Clamp- 07 Nos., 33 KV F-bracket with Nuts & Bolts- 02 Nos., F-bracket with Nuts & Bolts- 05 Nos., Top Channel clamp with Nuts & Bolts- 04 Nos., Guarding Angle Clamp with Nuts & Bolts- 06 Nos. GI Wire- 110 Kg.
Erection of Double ST Pole with all fitting
Erection of Single ST Pole with all fitting
Grouting of Pole
Earthing of Pole
Erection of Stay
Guarding of 11 KV Line
stringing and sagging of ACSR Dog/Weasel Conductor
Dismentalling of old 11 KV Line
Sagging of 11 KV Line
Dismentalling of old 33 KV Line
Sagging of 33 KV Line
Painting of Pole
A Enterprises
M/s Rudra Associate
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .