Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC Accepted for lowest rate quoted | |
| 2 | L2₹31.7 L+₹3.2 L (11.2%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹34.6 L+₹6.1 L (21.6%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
9 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) GURGAON
GE (AF) GURGAON
ADDN ALTN TO OPS BLDG AT AFS RAJOKRI UNDER GE AF GURGAON
2023_MES_608756_1
GE/GUR-/NIT-18/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹86,000
23 Sept 2023
12 Jul 2023
11 Aug 2023
12 Jul 2023
9 Aug 2023
26 Jul 2023
Amount
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified and as directed.
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Slabs supported on walls,beams and columns in floors,roofs, complete all as specified and as directed.
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Beams, cantilevers, bressummers, lintel over 1.5 span complete all as specified and as directed.
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in fins, fascias, louvres, parapets, and railings exc.60cm in height, newels,balustrade, and the like complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports,overhangs,etc. also splays between floors in rough finished flat surfaces and etc complete all as specified and as directed.
M&L for Form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete, complete,all as specified and as directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10 cm but n exc 20cm wide rough finished complete all as specified and as directed.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified.
All as per item No.9 here-in-before but 6 mm dia to 8 mm dia.
All as per item No. 9 above but 5 mm dia & over upto & including 10 mm dia in stirrups,spacers and binders, complete all as specified.
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring/tiles etc complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles etc complete all as specified and as directed.
M&L for Non - skid (joint free) coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for 15 mm thick plastering in two layers (10+5) mm in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer's instruction and complete all as specified and as directed. Note: WPC shall be measured and paid separately.
M&L for rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified and as directed.
Supply only intergral water proofing compound ISI Marked complete all as specified.
M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for Complete removal of existing surfaces of wall by mechanised sander of approved brand having suction vaccum bag or by manual scraping tools where mechanical removal is not possible and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed. NOTE: Stage for preparation of surfaces shall be got approved from Engr-in-charge in stage passing register before applying the primer/finishes.
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
M&L for Complete removal of existing surfaces of ceiling by mechanised sander of approved brand having suction vaccum bag or by manual scraping tools where mechanical removal is not possible and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed. NOTE: Stage for preparation of surfaces shall be got approved from Engr-in-charge in stage passing register before applying the primer/finishes.
M&L for preparation of newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
M&L for Complete removal of existing surfaces of wall by mechanised sander of approved brand having suction vaccum bag or by manual scraping tools where mechanical removal is not possible and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. NOTE: Stage for preparation of surfaces shall be got approved from Engr-in-charge in stage passing register before applying the primer/finishes.
M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform complete all as specified and as directed.
M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed.
Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified and as directed.
S&F solid PVC door frame of size 50 mm X47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified and as directed.
S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed complete all as specified and as directed.
S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium anodized handles suitable size 2 Nos in each door,100 mm long aluminum anodized hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified and as directed.
S&F for 5.50 mm thick sheet glass ordinary quality and glazing each pane fixed with neoprene rubber gasket in aluminium frame work complete all as specified and as directed.
S&F 9 mm thick prelaminated particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified and as directed.
S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed.
S&F as in repair 150 mm double action door spring hinges, brass, with phosphor bronze wire spring, bright polished complete all as specified and as directed.
S&F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified and as directed.
S&F in repair 150 mm (Overall length of cover plate) Floor door stopper of brass body and tongue with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F Collapsible steel gates, top/side hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
S&F Box type (steel) window / ventiliators (Double shutter, gauzed and glass) as per drawing No. CEAF/STD-171/07 sheet No 1/1 to 4/4 dated 05.11.2007, fixed with dash through bolts of standard quality, 100 mm long steel handle in each shutter, 2 Nos steel tower blots 150 mm long & two hinges of each shutter of 100 mm length etc including 4 mm thick sheet glass for window shutter and 4 mm frosted glass for ventilator, 0.36mm stainless steel wire cloth with 1.40mm aperature, mild steel 12 mm square bar for guard bars/ girlls with frame including two coat of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and as directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified and as directed.
M&L for half brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified and as directed.
Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc complete all as specified and as directed.
M&L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified and as directed.
Demolition of Mud in roofs, any thickness including plastering and leeping,(whether full thickness removed etc complete all as specified and as directed.
M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50 mm graded stone aggregate) as in roof padding complete all as specified and as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified and as directed. Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm followed by a tack coat @ 1.2 kg per sqm using 85/25 grade industrial hot blow bitumen over it laid with APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm as per manufacturer's instructions complete all as specified and as directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for laying cement concrete roof tiles complete all as specified and as directed.
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments complete all as specified and as directed.
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
S&F in repair 5 mm thick glass mirror of size (700X500) mm with double coat for protection and longevity grounded edges for safety and silver plating on the back for better reflection complete all as specified and as directed. (Cat No. B3510112) Make : Cera/Equivalent out of makes out of list of makes.
S&F Glass Shelf 600 mm long.(Cat No.ACN-1171N) complete all as specified and as directed. Make: Jaquar/Equivalent out of makes out of list of makes.
S&F in repair Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook complete all as specified and as directed. (Cat No.ALD-573) Make: Jaquar/Equivalent out of makes out of list of makes.
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody for reuse or takeing in schedule of credit and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or takeing in schedule of credit complete all as specified and as directed. (Accessories or components to be provided free for replacement by department)
Taking unserviceable sub main wiring of any type/size including wires, conduits/battens etc complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable / serviciable MCB DB's/AC's box to deposit in store for keeping in safe custody for reuse or takeing in schedule of credit of any size/rating complete all as specified and as directed by Engr-in-charge.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including concealed PVC conduit size of not less than 25mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover /modular white cover plate with frame and modular metal flush box of required module at site for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and making good, disturb surface as it is, all as specified and as directed for The following:- Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green
(a) One light point controlled by one, one way switch.
(b) One Ceiling fan/Exhaust fan point controlled by one, one way switch.
(c) All as per item No 5 above but 3 Pin 5 Amp Socket on the same board, complete all as specified.
(d) All as per item No 5 above but 3 Pin 5 Amp Socket on independent board , complete all as specified and directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and including concealed PVC conduit size of not less than 25mm concealed in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover/modular white cover plate with frame and modular metal flush box of required module at site for mounting switch, socket and fan regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm and for one 6 pin socket outlet two in one 16/6 amps on an indeendent board including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green and making good, disturb surface as it is complete all as specified and as directed.
M&L in replacement for sub main wiring with two single core 6 sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 6 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and as directed by Engr-in-charge.
M&L in replacement for sub main wiring with two single core 4 sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 4 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and as directed by Engr-in-charge.
M&L in replacement for sub main wiring with two single core 10 sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 10 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete all as specified and as directed by Engr-in-charge.
S&F Modular switch 1 way 6A, 01 module complete all as specified and as directed.
S&F Modular switch 1 way 16A, 01 module complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F Modular fan regulator step type 120W 2 module complete all as specified and as directed.
S&F ceiling rose, surface bakelite, size as per relevant IS, three terminals complete all as specified and directed
S&F in replacement sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one double pole MCB SP 20 Amps for geyser complete all as specified and as directed.
S&F in replaceent of MCB DB sheet metal enclosure single pole and neutral 240V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and as directed.
All as per item No 82 above but 8 way, complete all as specified and as directed.
All as per item No 82 above but 4 way, complete all as specified and as directed.
All as per item No 82 above but 2 way, complete all as specified and as directed.
S&F in replaceent of MCCB DB sheet metal enclosure vertical Triple pole and neutral 415V with 200 Amp suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed .
S&F MCB, single pole & neutral, 240 Volts ( 40-63) Amps,10KA, B series complete all as specified and as directed.
S&F MCB, single pole, 240 Volts (05 to 32) Amps,10KA, B series complete all as specified and as directed.
S&F MCCB, Three pole & neutral, 415 Volts 200 Amps,25KA complete all as specified and as directed .
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F LED security light fitting 35/36 Watt, having uniformty ratio 0.25 , high pressure die cast aluminium housing , heat resistant toughened glass frame , IP-65 protection complete with lamp & connected items and connection with suitable cable from celing rose to light fitting and including supply fixing on GI pipe bracket made out of suitable dia gi pipe medium grade 1.2 m long bend to shape and fixed on wall with flat iron clamps nut, bolts washers etc specified and as directed
Taking down and re-fixing of ceiling fans 1200/1400mm sweep after servicing, cleaning, painting, and necessary repairs including replacement of unservicdable parts, hanging assambly, copper winding, bush bearing, ball bearing, capacitor 2.5/3.5 mfd, flexible copper cord three core PVC cable of size 1/1.5 Sqmm of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge. Note :- The rate of unserviceable parts shall be included in the quoted rate.
Taking down and re-fixing of exhaust fans 300/450mm sweep after servicing, cleaning, painting, and necessary repairs including replacement of unservicdable parts, hanging assambly, copper winding, bush bearing, ball bearing, capacitor 2.5/3.5 mfd, flexible copper cord three core PVC cable of size 1/1.5 Sqmm of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge. Note :- The rate of unserviceable parts shall be included in the quoted rate.
M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI wire 6 mm Dia as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI
and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision 20 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed . NOTE: (i) The concrete pit shall be PCC 1:3:6 type C-140 mm thick pre cast cover slab of RCC(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cost iron cover shown in the electrical plate No.3 of MES SSR Part -1 (ii) item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe,bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length Galvised earth strip/wire 6Sq mm.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep complete all as specified and as directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6 Sqmm galvanised iron or steel wire complete all as specified and as directed
Material and labour for laying GI tubing of size 25mm bore ,light grade for protection of under ground cable in trench /Gate light/under road /croosing or fixed to wall /pole all as specified and as directed
akhil enterprises
M/S Rohit Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .