| # | Company | Amount |
|---|---|---|
| 1 | ₹17.6 Cr M S SEN BROTHERS ENTERPRISES PVT ITD 2 P 36 RECOL PARK CITY CENTRE DURGAPUR 713216 MBL 9800884523 9434010390 | ₹17.6 Cr |
Tender Value
₹24.3 Cr
EMD Value
₹24.3 L
Closing Date
10 Oct 2025, 3:00 pmClosed
Construction of TAMS (Transmission Asset Management System) Building at DVC Substation, Maithon.
NBCC/RBG-WB/DVC/2025/370
NBCC/RBG-WB/DVC/2025/370
Open Tender-Domestic
Civil Works General
Unknown (Unspecified Location)
₹11,800
₹24.3 L
14 Jul 2026
27 Sept 2025
10 Oct 2025
10 Oct 2025
7 Nov 2025
BOQ DVC Maithon
NAME OF WORK:CONSTRUCTION OF TWO STOREYED SWITCH YARD AND CONTRIOL ROOM TAMS BUILDING
AT DVC MAITHON SUBSTATION
TAMS BUILDING (G+2), BOQ - CIVIL WORKS
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
A 2.0 EARTH WORKS
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5
1 2.6 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
i 2.6.1 All kinds of soils Cum 3428.96 177.50 608,640.79
Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
3 2.25 consolidating each deposited layer by ramming and watering, lead Cum 3592.10 196.00 704,051.80
up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including
4 2.27 watering, ramming, consolidating and dressing complete. Cum 495.59 2,123.75 1,052,514.75
Surface dressing of the ground including removing vegetation and
5 2.28 inequalities not exceeding 15 cm deep and disposal of rubbish, lead
up to 50 m and lift up to 1.5 m.
i 2.28.1 All kinds of soil Sqm 2038.25 34.15 69,606.24
Clearing jungle including uprooting of rank vegetation, grass, brush
wood, trees and saplings of girth up to 30 cm measured at a height
6 2.31 of 1 m above ground level and removal of rubbish up to a distance sqm 2038.25 17.60 35,873.20
of 50 m outside the periphery of the area cleared.
Providing and injecting chemical for pre constructional anti - termite
treatment and creating and chemical barrier under and around the
column pits wall trenches basement excavation top surface if plinth
filling junction of wall and floor, along the external permeter of
binding expansion joints surrounding of pipes and condult
7 etc.complete (plinth area of the building at ground floor only shall
be measured as per I.S 6313 (part 2 1981). Aldrine emulsifiable
concentrate or any other approved material such as Hepthachlor of
CHlordane will be used. The rate of application of chemical emultion
shall be as follows :=
i i (1) Treatment for masonry and foundation 5 liters per Sqm
(2) Back fill in immediate contact with foundation 7.5 liters per Sqm
iii iii (3) Treatment of top surface of plinth filling 5 liters per Sqm.
(4) Treatment of soil along external per meter of building 7.50 liters
iv iv per Sqm.
(5) Treatment of soil under apron along external per meter 5 liter
TOTAL (Carried Over to Summary of Civil Works) 3,032,918.05 -
B 4.0 CONCRETE WORKS
Providing and laying in position cement concrete of specified grade
1 4.1 excluding the cost of centering and shuttering - All work up to plinth
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural
a 4.1.6 sources : 6 graded stone aggregate 40 mm nominal size derived Cum 1.00 7,178.75 7,178.75
from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
b 4.1.8 sources : 8 graded stone aggregate 40 mm nominal size derived Cum 244.08 6,812.00 1,662,657.80
from natural sources)
Providing and laying cement concrete in retaining walls, return walls,
walls (any thickness) including attached pilasters, columns, piers,
abutments, pillars, posts, struts, buttresses, string or lacing courses,
2 4.2 parapets, coping, bed blocks, anchor blocks, plain window sills,
fillets, sunken floor etc., up to floor five level, excluding the cost of
centering, shuttering and finishing:
1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural
i 4.2.2 sources : 3 graded stone aggregate 20 mm nominal size derived Cum 5.23 10,357.55 54,221.48
from natural sources).
1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural
ii 4.2.5 sources : 6 graded stone aggregate 20 mm nominal size derived Cum 2.20 9,311.40 20,496.72
from natural sources)
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Centering and shuttering including strutting, propping etc. and
removal of form work for :
i 4.3.1 Foundations, footings, bases for columns. Sqm 247.00 392.15 96,861.05
Providing and laying damp-proof course 50mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from
natural sources : 4 graded stone aggregate 20mm nominal size
derived from natural sources).
Extra for providing and mixing water proofing material in cement
4 4.12 concrete work in doses by weight of cement as per manufacturer's 55.00 18.15 998.25
Providing & applying a coat of residual petroleum bitumen of grade
of VG-10 of approved quality using 1.7kg per square metre on damp
5 4.13 proof course after cleaning the surface with brushes and finally with Sqm 172.00 146.15 25,137.80
a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1
cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm
nominal size) over 75mm thick bed of dry brick ballast 40 mm
6 4.17 nominal size, well rammed and consolidated and grouted with fine Sqm 189.43 749.30 141,941.40
sand, including necessary excavation, levelling & dressing & finishing
the top smooth.
TOTAL (Carried Over to Summary of Civil Works) 2,094,762.25 -
C 5.0 REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and
removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses,plinth
and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
d 5.9.4 Shelves (Cast in situ) Sqm 22.58 927.25 20,936.56
Lintels, beams, plinth beams, girders, bressumers and cantilevers
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 2796.43 961.30 2,688,204.55
g 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 261.49 764.95 200,022.95
h 5.9.8 Spiral staircases (including landing) Sqm 0.00 798.35 -
i 5.9.9 Arches, domes, vaults up to 6 m span Sqm 5.00 2,154.35 10,771.75
Small lintels not exceeding 1.5m clear span, moulding as in cornices,
j 5.9.15 window sills, string courses, bands, copings, bed plates, anchor Sqm 25.97 392.15 10,183.72
blocks and the like.
k 5.9.16 Edges of slabs and breaks in floors and walls
l 5.9.19 Weather shade, Chajjas, corbels etc., including edges. Sqm 10.00 951.10 9,511.00
Extra for additional height in centering, shuttering where ever
required with adequate bracing, propping etc., including cost of de-
2 5.11 shuttering and decentering at all levels, over a height of 3.5 m, for
every additional height of 1 metre or part thereof (Plan area to be
Suspended floors, roofs, landing, beams and balconies
(Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting,
3 5.22 bending, placing in position and binding all complete upto plinth
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting,
4 5.22A bending, placing in position and binding all complete above plinth
Thermo-Mechanically Treated bars of grade Fe-500D or more.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and laying in position ready mixed or site batched design
mix cement concrete for reinforced cement concrete work; using
coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS: 9103 to
accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding
5 5.33.1 the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; for the following grades of
concrete. Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable separately. In case
the cement content in design mix is more than 110% of the specified
minimum cement content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra cement.
a) 5.33.1 All works upto plinth level.
Concrete of M30 grade with minimum cement content of 350 kg
b) 5.33.2 All works above plinth level upto floor V level.
Concrete of M30 grade with minimum cement content of 350 kg
Add for using extra cement in the items of design mix over and
above the specified cement content therein.
Providing and fixing of expansion joint system related with floor
location as per drawings and direction of Engineer-In-Charge. The
joints system will be of extruded aluminum base members, self
aligning / self centering arrangement and support plates etc. as per
ASTM B221-02. The system shall be such that it provides floor to
floor /floor to wall expansion control system for various vertical
localtion in load application areas that accommodates multi
directional seismic movement without stress to it's components.
System shall consist of metal profiles with a universal aluminum
base member designed to accommodate various project conditions
and finish floor treatments. The cover plate shall be designed of
width and thickness required to satisfy projects movement and
5.44 loading requirements and secured to base members by utilizing
manufacturer’s pre-engineered self- centering arrangement that
freely rotates / moves in all directions. The Self - centering
arrangement shall exhibit circular sphere ends that lock and slide
inside the corresponding aluminum extrusion cavity to allow
freedom of movement and flexure in all directions including vertical
displacement. Provision of Moisture Barrier Membrane in the Joint
System to have watertight joint is mandatory requirement all as per
the manufactures design and as approved by Engineer -in- Charge.
(Material shall confirm to ASTM 6063).
Providing and fixing of expansion joint system related with wall joint
(internal/external) location as per drawings and direction of
Engineer-In- Charge. The joints shall be of extruded aluminum base
members, self aligning / centering arrangement and support plates
as per ASTM B221- 02. The material shall be such that it provides an
Expansion Joints System suitable for vertical wall to wall/ wall to
corner application, both new and existing construction in office
Buildings & complexes with no slipping down tendency amongst the
components of the Joint System. The Joint System shall utilize light
weight aluminum profiles exhibiting minimal exposed aluminum
surfaces mechanically snap locking the multicellular to facilitate
movement. (Material shall confirm to ASTM 6063).
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and fixing of expansion joint system of approved make and
manufactures for various roof locations as per approved drawings
and direction of Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self centering
arragement support plates asper ASTM B221-02. The system shall be
such that it provides watertight roof to roof/roof to corner joint
cover expansion control system that is capable of accommodating
multidirectional seismic movement without stress to its
components. System shall consist of metal profile that incorporates
a universal aluminum base member designed to accommodate
various project conditions and roof treatments. The cover plate shall
be designed of width and thickness required to satisfy movement
and loading requirements and secured to base members by utilizing
5.46 manufacturer’s pre-engineered self-centering arrangement that
freely rotates / moves in all directions. The Self centering
arrangement shall exhibit circular sphere ends that lock and slide
inside the corresponding aluminum extrusion cavity to allow
freedom of movement and flexure in all directions including vertical
displacement. The Joint System shall resists damage or deterioration
from the impact of falling ice, exposure to UV, airborne
contaminants and occasional foot traffic from maintenance
personnel. Provision of Moisture Barrier Membrane in the Joint
System to have water tight joint is mandatory requirement.
(Material shall confirm to ASTM 6063).
TOTAL (Carried Over to Summary of Civil Works) 57,771,762.72 -
D 6.0 BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in foundation and plinth in:
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 24.25 7,132.25 172,963.75
Brick work with non modular fly ash bricks conforming to IS:12894,
2 6.34 class designation 10 average compressive strength in super structure
above plinth level up to floor V level in :
i 6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) Cum 691.46 8,752.55 6,052,027.28
Half brick masonry with non modular fly ash bricks of class
3 6.45 designation 10, conformingio IS :12894, in super structure above
plinth and upto floor V level.
i 6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Sqm 730.99 1,105.80 808,324.87
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars
at every third course of half brick masonry.
Brick edging 7cm wide 11.4 cm deep to plinth protection with
common burnt clay F.P.S. (non modular) bricks of class designation
7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine
TOTAL (Carried Over to Summary of Civil Works) 7,121,847.77 -
E 8.0 MARBLE & GRANITE WORK
Providing and fixing 18mm thick gang saw cut ( premoulded and
prepolished) machine cut for kitchen platforms, vanity counters,
window sills , facias and similar locations of required size of
approved shade, colour and texture laid over 20mm thick base
1 8.2 cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated
with white cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to edge to give
high gloss finish etc. complete at all levels.
a) 8.2.2 Granite of any colour and shade
ii 8.2.2.2 Area of slab over 0.50 sqm Sqm 22.58 5,136.30 115,973.54
Extra for fixing marble / granite stone over and above corresponding
basic item, in facia and drops of width upto 150mm with epoxy resin
baesd adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash
basins/ kitchen sink in kitchen platform, vanity counters and similar
3 8.5 location in marble/Granite/Stone work including necessary holes for each 27 978.70 26,424.90
pillar taps etc. including rubbing and polishing of cut edge etc.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and fixing stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal
partitions by cutting a chase of appropriate width with chase cutter
and embedding the stone in the chase with epoxy grout or with
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 6 mm nominal size) as per direction of Engineer-in-charge
and finished smooth. Granite Stone of approved shade
Providing and fixing machine cut, mirror / eggshell polished , Granite
stone work for wall lining (veneer work) including dado, skirting,
risers of steps etc., in required design and pattern wherever
Derived required, stones of different finished surface texture, on 12 mm
Rate DSR- (average) thick cement mortar 1:3 (1 cement : 3 oarse sand) laid and
5 2023 jointed with white cement slurry @ 3.3 kg/Sq.Mt. including pointing Sqm. 189.00 8,625.70 1,630,293.10
(Refer with white cement slurry admixed with pigment of matching shade,
,8.11) including rubbing, curing, polishing etc. all complete as per
Architectural drawings, and as directed by the Engineer-in-Charge. a.
18 mm thick Granite stone slab any colour etc.
Providing and fixing Ist quality ceramic glazed wall tiles conforming
to IS: 15622 (thickness to be specified by the manufacturer), of
approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-Charge, in skirting,
6 8.31 risers of steps and dados, over 12 mm thick bed of cement mortar Sqm 647.35 1,267.95 820,813.01
1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry
@ 3.3kg per sqm, including pointing in white cement mixed with
pigment of matching shade complete.
TOTAL (Carried Over to Summary of Civil Works) 2,869,639.56 -
F 9.0 WOOD & PVC WORK
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction
with frame of 1st class hard wood and well matched commercial 3
ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with
necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm
2 9.23 minimum depth on all edges of flush door shutters (over all area of Sqm 213.98 462.35 98,931.34
door shutter to be measured).
Providing and fixing wooden moulded beading to door and window
frames with iron screws, plugs and priming coat on unexposed
surface etc. complete :2nd class teak wood.50x12 mm.
Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats, square or round bars etc. including
4 9.48.2 priming coat with approved steel primer all complete.Fixed to Kg 3559.68 238.35 848,449.73
openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade, with necessary
screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade, with necessary
screws etc. complete :
Providing & Fixing decorative high pressure laminated sheet of plain
/ wood grain in gloss / matt / suede finish with high density
7 9.127 protective surface layer and reverse side of adhesive bonding quality
conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and fixing factory made uPVC glazed/wire mesh windows/
doors comprising of lead free uPVC multi-chambered frame, sash
and mullion/coupler (wherever required) extruded profiles having
minimum wall thickness of 1.70 mm for Series R1 and R2 profiles
and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608
in any shape, colour and design duly reinforced with galvanized mild
steel section made of required shape & size as per CPWD
Specification, uPVC extruded glazing beads, interlocks and Inline
sash adaptor (where ever required) of appropriate dimension, EPDM
gasket, hardware, SS 304 garde fastteners of minimum 8 mm dia
with countersunk head, comprising of matching polymade PA6 grade
sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14,
8 9.147A plastic packers, plastic caps and necessary stainless steel screws etc.
Profile of frame, sash & mullion (if required) shall be mitred cut and
fusion welded/ mechanically jointed duly sealed at all corners,
including drilling of holes for fixing hardware and drainage of water
etc. After fixing frame the gap between frame and adjacent finished
wall shall be filled with weather proof silicon sealent over backer rod
of approved size and quality, all complete as per approved drawing
conforming to CPWD specification & direction of Engineer-in-charge.
Section of steel reinforcement and cross sections of uPVC profiles to
be as per design approved by Engineer-in-charge.
Wire mesh / Glazing of plain / toughned/ laminated/ double glass
unit with / without high performance coatings as per design
requirments and conforming to IS: 3548 & IS: 16231 shall be paid
Note:- Structural design proof checked from a Government
Engineering Institute, to be provided by the manufaturer for :
(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3
(ii) Sites with structure height more than 20m for all wind speeds
Three track three panels sliding window with two glazed & one wire
9.147.A4 mesh panels with Aluminium channel for roller track, wool pile,
nylon rollers with SS 304 body.
Using R3 series with frame (98 mm & abobe) x (40 mm & above) &
both glazed and fly screen sash (30 mm & above) x (55 mm & above)
i 9.147.A4.2 with zinc alloy (zamak) powder coated handle on every glazed panel Sqm 222.48 10,874.20 2,419,292.02
along with multi-point locking system. (Height upto 1.8m).
Providing and fixing non load bearing fixed frame for fire resistant
glazed partition for 120 minutes Fire Rating, made out to a profile of
dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as
per test evidence suitable for fixing fire rated glass for 120 minutes
of both integrity & radiation control (EW120) & minimum 20
minutes of insulation (EI20).The profile has to be fixed to the
supporting construction by means of anchor fasteners of size M10 x
80, every 150 mm from the edges and every 500 mm (approx) c/c.
Linear measurement of frame shall be measured for payment. The
frame shall be filled with mineral wool insulation of density
minimum 96kg/ cum. and finished with a approved fire resistant
primer or Powder coating of not less than 30 micron in desired
shade as per NBC 2016, IS 16231 (Part 3):2016 and directions of
Engineer - in- Charge.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and fixing glazing in fire resistant door shutters, fixed
panels & partitions etc., with G.I. beading made out of 1.6 mm thick
G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm
screwed with M4 x 38 mm SS screws at distance 75 mm from the
edges and 150 mm c/c , including applying a coat of approved fire
resistant primer/ powder coating of not less than 30 micron on G.I.
beading, & special ceramic tape of 5 x 20 mm size etc complete in all
respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction
of Engineer-in-charge with glass of required thickness having 120
minutes of fire resistance both integrity & radiation control (EW120)
10 9.164 and minimum 20 minutes of insulation (EI20). The manufacturer Sqm 30.24 43,677.65 1,320,812.14
have to give test report/certification of fire glass and the glass
should have the stamp showing the value of E, EW & EI. The glass
shall be tested in approved NABL accredited lab or by any other
accreditation body which operates in accordance with ISO/IEC 17011
and accredits labs as per ISO/IEC 17025 for testing and calibration
scopes shall be eligible. The maximum glazing size shall not be more
than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing approved brand and manufacture of Rack and
pinion door closer TS 68 EN size 2/3/4, with std. arm and with two
independent closing valves and latching speed adjustable by arm.
11 MR-1 Silver finish. As per EN 1154. Each 103 2,910.00 299,730.00
Approved Make : dormakaba / Hafele / GEZE with necessary
accessories and screws etc. complete in all respects as per
manufacture ofrs' specificatios & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture of 4012 wall
mounted door stop dome with 60mm length with fixing accessories
12 MR-2 Approved Make : dormakaba / Hafele / GEZE with necessary Each 117 701.00 82,017.00
accessories and screws etc. complete in all respects as per
manufacture ofrs' specificatios & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture of Pure 8100
Type 3 Package with Pair of Pure 8100 Design Lever Handle on Roses
& escutcheons. Including 271a Sash lock with 72mm CTC, 55mm
Backset 20mm Square forend. EPC 60mm length oneside thumb turn
otherside coin release operation Approved Make : dormakaba /
Hafele / GEZE with necessary accessories and screws etc. complete
in all respects as per manufacture ofrs' specificatios & as directed by
Engineer-in-charge.
Providing and fixing approved brand and manufacture of Stainless
Steel Tower bolt 300 mm long with 10 mm dia ( TR 1210SS) along
14 MR-4 with necessary accessories and screws etc. complete in all respects Each 234 866.00 202,644.00
as per manufacture ofrs' specificatios & as directed by Engineer-in-
Providing and fixing approved brand and manufacture of Stainless
Steel Tower bolt 150 mm long with 10 mm dia ( TS 610SS) along with
15 MR-5 necessary accessories and screws etc. complete in all respects as per Each 10.0 566.00 5,660.00
manufacture ofrs' specificatios & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture of Stainless
Steel Door Buffer wall mounted 22 mm dia,75 mm long (DB (22)
16 MR-6 along with necessary accessories and screws etc. complete in all Each 117.00 523.00 61,191.00
respects as per manufacture ofrs' specificatios & as directed by
Engineer-in-charge.
Providing and fixing approved brand and manufacture of Stainless
Steel Handle 125 mm long with necessary accessories and screws
17 MR-7 etc. complete in all respects as per manufacture ofrs' specificatios & Each 234.00 699.00 163,566.00
as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture of Stainless
Steel Sliding Tower Bolt 300x16 mm long with necessary accessories
18 MR-8 and screws etc. complete in all respects as per manufacture ofrs' Each 256.00 1,004.00 257,024.00
specificatios & as directed by Engineer-in-charge.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to
Derived windows, Doors and clerestory windows using wire gauge with
19 Item average width of aperture 1.4 mm in both directions with wire of Sqm 222.48 2,129.05 473,671.04
(9.135.2) dia. 0.50 mm all complete. With aluminium Snap beading.
Providing and fixing steel (white power coated) crescent lock for
20 9.153 uPVC / aluminium sliding window/ door with necessary screws etc. Each 182.00 198.30 36,090.60
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
TOTAL (Carried Over to Summary of Civil Works) 6,326,619.00 1,796,246.00
G 10.0 STEEL WORK
Providing and fixing pressed steel door frames conforming to IS:
4351, manufactured from commercial mild steel sheet of 1.60 mm
thickness, including hinges, jamb, lock jamb, bead and if required
angle threshold of mild steel angle of section 50x25 mm, or base ties
of 1.60 mm, pressed mild steel welded or rigidly fixed together by
mechanical means,
including M.S. pressed butt hinges 2.5 mm thick with mortar guards,
lock strike-plate and shock absorbers as specified and applying a
coat of approved steel primer after pre-treatment of the surface as
directed by Engineer-in-charge:
10.14.1 Profile B
10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb metre 470.85 583.30 274,646.81
Steel work welded in built up sections/ framed work including
cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required
In stringers, treads, landings etc. of stair cases including use of
chequered plate wherever required, all complete.
In gratings, frames, guard bar, ladder, railings, brackets, gates and
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box
for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid
of 1.5 mm thick M.S. sheet with its top surface hacked for proper
bonding, top lid shall be screwed into the cast iron/ M.S. sheet box
by means of 3.3 mm dia round headed screws, one lock at the
corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape
as per standard drawing.
Providing and fixing carbon steel galvanised ( minimum coating 5
micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield
strength 480 N/mm2), counter sunk head, comprising of 10 m dia
polyamide PA 6 grade sleeve, including drilling of hole in frame ,
concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless
5 10.28 steel dash fasteners , stainless steel bolts etc., of required size, on KG 2124.27 772.40 1,640,786.15
the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-charge, (for payment
purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.)
Fabrication, supply and Installation of New clear line glass railing
system by Ozone made of Heavy duty aluminum U Type Hollow walls
Base channel ( HWBC) (OZRF-NCLSYS- HWBC-AL) AL-6063 grade with
mill finish of size 12.5mm( thick)72( wide)x122 mm( height). Glass
Specs. is 16.89mm thk (8mm CT+ .89SGP+8MM CT) to be GRIPPED
with fixing kit (OZRF-NCL-ACC-KIT-17MM) made of self-pushing
clamps ( SPC) made by hardened aluminum -6063 grade each at
maximum 350mm cc to cc . glass should be lifted from base by Solid
Nylon L Block separates at least 3 nos/ meters. HWBC to be fixed
with M12 GI stud chemically grouted. Glass should be fixed with
completely dry system so that in case of breakage it can be changed
without any silicon cutting and very fast as well.. exposed edges of
HWBC (if any) to be covered with SS 304 grade end caps. The Top
Edge of glass will be covered with SS 304 grade Round slotted tube
of Dia42x1.5 mm thk. fixed on the glass edge with EPDM gasket. The
Vertical joint of glass will be free from silicon. The total height of the
system will be max. 900 mm from ledge top, All top rail joints will be
joined by using argon welding only.
TOTAL (Carried Over to Summary of Civil Works) 1,998,928.65 167,675.25
H 11.0 FLOORING WORK
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Kota stone slab flooring over 20 mm (average) thick base laid over
and jointed with grey cement slurry mixed with pigment to match
1 11.26 the shade of the slab including rubbing and polishing complete with
base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and
pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3
2 11.27 coarse sand) and jointed with grey cement slurry mixed with sqm 5.00 2,354.70 11,773.50
pigment to match the shade of the slabs, including rubbing and
polishing complete.
Extra for pre finished nosing to treads of steps of marble stone.
Extra for marble stone flooring in treads of steps and risers using
single length up to 2.00 metre.
Providing and laying rectified Glazed Ceramic floor tiles of size
300x300 mm or more (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of approved
make, in all colours, shades, except White, Ivory, Grey, Fume Red
Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse
sand), jointing with grey cement slurry @ 3.3 kg/ sqm including
pointing the joints with white cement and matching pigments etc.,
Providing and laying Vitrified tiles in different sizes (thickness to be
specified by manufacturer), with water absorption less than 0.08 %
and conforming to I.S. 15622, of approved make, in all colours &
shade, in skirting, riser of steps, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including grouting the joint with white cement
& matching pigments etc. complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved brand &
manufacturer, in all colours and shade, laid on 20 mm thick cement
mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement
slurry @3.3 kg/sqm including grouting the joints with white cement
and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only . Laying of tiles will be done with the
notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
a) 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
Providing and laying flamed finish Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the
building all complete as per the architectural drawings with 18 mm
thick stone slab over 20 mm (average) thick base of cement mortar
1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry
7 11.55.1 and pointing with white cement slurry admixed with pigment of Sqm 1515.39 3,186.70 4,829,107.54
matching shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge
:Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown,
Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the
building all complete as per the architectural drawings with 18 mm
thick stone slab over 20 mm (average) thick base of cement mortar
1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry
8 11.56.1 and pointing with white cement slurry admixed with pigment of Sqm 189.00 4,481.30 846,984.30
matching shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab colour of Black, Cherry/Ruby Red or
TOTAL (Carried Over to Summary of Civil Works) 8,186,916.51 -
I 12.0 ROOFING
Providing and laying gola 75x75mm in cement concrete M15 grade
1 12.21 including finishing with cement mortar 1:3 (1 cement : 3 fine sand) rmt. 1603.02 305.15 489,161.55
as per standard design in 75x75 mm deep chase.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Making khurras 45x45 cm with average minimum thickness of 5 cm
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400
2 12.22 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse each 6.00 298.25 1,789.50
sand) and a coat of neat cement, rounding the edges and making
and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC RAIN
WATER PIPES conforming to IS : 13592 Type A including jointing with
seal ring conforming to IS : 5382 leaving 10 mm gap for thermal
expansion.(i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
4 12.42 conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
a) 12.42.1 Coupler
c) 12.42.6 Shoe (Plain)
Providing and fixing tiled false ceiling of specified materials of size
595x595 mm in true horizontal level, suspended on inter locking
metal grid of hot dipped galvanized steel sections ( galvanized @ 120
grams/ sqm, both side inclusive) consisting of main "T" runner with
suitably spaced joints to get required length and of size 24x38 mm
made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm
center to center and cross "T" of size 24x25 mm made of 0.30 mm
thick (minimum) sheet, 1200 mm long spaced between main "T" at
600 mm center to center to form a grid of 1200x600 mm and
secondary cross "T" of length 600 mm and size 24x25 mm made of
0.30 mm thick (minimum) sheet to be interlocked at middle of the
1200x600 mm panel to form grids of 600x600 mm and wall angle of
size 24x24x0.3 mm and laying false ceiling tiles of approved texture
in the grid including, required cutting/making, opening for services
like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main
"T" runners to be suspended from ceiling using GI slotted cleats of
size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50
mm long dash fasteners, 4 mm GI adjustable rods with galvanised
butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm
center to center along main T, bottom exposed width of 24 mm of
all T-sections shall be pre-painted with polyester paint, all complete
for all heights as per specifications, drawings and as directed by
Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global
white color tiles of size 595x595 mm and 0.5 mm thick
with 8 mm drop; made of GI sheet having galvanizing of
100 gms/sqm (both sides inclusive) and 20% perforation
a) 12.52.2 area with 1.8 mm dia holes and having NRC (Noise sqm 299.54 2,068.75 619,680.72
Reduction Coefficient ) of 0.5, electro statically polyester
powder coated of thickness 60 microns (minimum),
including factory painted after bending and perforation,
and backed with a black Glass fiber acoustical fleece.
TOTAL (Carried Over to Summary of Civil Works) 1,134,893.14 -
J 13.0 FINISHING WORK
1 13.4 12 mm cement plaster of mix :
18 mm cement plaster in two coats under layer 12 mm thick cement
plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm
thick cement plaster 1:6 (1 cement : 6 fine sand).
Add or deduct for plaster drip course/ groove in or moulding to
R.C.C. projections.plastered surface
4 13.16 6 mm cement plaster of mix :
Extra for providing and mixing water proofing material in cement
plaster work in proportion recommended by the manufacturers.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Distempering with 1st quality acrylic distemper (ready mixed) having
VOC content less than 50 gms/litre, of approved manufacturer, of
6 13.41.1 required shade and colour complete, as per manufacturer's Sqm 9912.08 185.65 1,840,178.09
specification. Two or more coats on new work.
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC
content less than 50 grams/litre
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and
i 13.45.1 including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 2455.31 223.60 549,008.10
Finishing walls with Deluxe Multi surface paint system for interiors
9 13.48 and exteriors using Primer as per manufacturers specifications :
Painting wood work with Deluxe Multi Surface Paint of required
shade. Two or more coat applied @0.90 ltr/10 sqm over an under
coat of primer applied @0.75 ltr/ 10 sqm of approved brand or
Providing and applying plaster of paris putty of 2 mm thickness over
10 13.26 plastered surface to prepare the surface even and smooth complete. Sqm 4608.71 262.70 1,210,709.42
Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :
i 13.61.1 Two or more coats on new work Sqm 385.97 155.90 60,172.41
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
Providing and fixing GI hexagonal chicken wire mesh of size 12mm
x22g at the junction of disimilar surfaces of brick masonry wall and R
C C column by beams and the like including necessary nails for fixing
etc, complete all as per specification and direction of Engineer -in -
charge for all floor at all heights.
TOTAL (Carried Over to Summary of Civil Works) 11,797,442.42 45,423.30
K 21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular
sections/appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and
screws or with fixing clips, or with expansion hold fasteners including
necessary filling up of gaps at junctions, at top, bottom and sides
with required PVC/neoprene felt etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed echanically wherever
required including cleat angle, Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge.
Glazing and paneling to be paid for separately) :
a) 21.1.1 For fixed portion.
Powder coated aluminium (minimum thickness of powder coating 50
For shutters of doors, windows & ventilators including providing and
fixing hinges/ pivots and making provision for fixing of fittings
b) 21.1.2 wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50
Providing and fixing 12 mm thick prelaminated particle board flat
pressed three layer or graded wood particle board conforming to IS:
12823 Grade l Type ll, in panelling fixed in aluminum doors, windows
shutters and partition frames with C.P. brass / stainless steel screws
etc. complete as per architectural drawings and directions of
engineer-in-charge.
Pre-laminated particle board with decorative lamination on both
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket
3 21.3 etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid
in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50
Filling the gap in between aluminium frame and adjacent
RCC/Brickwork/ Stone Work by providing weather silicon sealant
over backer rod of approved quality as per architectural drawings
and direction of Engineer-in-charge
i 21.8.1 Upto 5mm depth and 5mm width metre 878.70 96.75 85,014.23
Providing and fixing HPL sheet in required shape and size or as per
drawing including structural steel in frame work using M.S. square/
rectangular tube in the required pattern as per architectural
TOTAL (Carried Over to Summary of Civil Works) 590,111.42 1,467,123.65
L 22.0 WATER PROOFING
Supplying and Stacking Filling sunken floor with over burnt jhama
brick aggregate 120mm to 40mm including compacting of materials
complete as specified and directed for all levels.
Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be
allowed to air cure for 4 hours. (b) Second layer of slurry of cement
@ 0.242 kg/sqm mixed with water proofing cement compound @
0.126 kg/sqm. This layer will be allowed to air cure for 4 hours SQM 144.03 617.05 88,875.07
followed with water curing for 48 hours. The rate includes
preparation of surface, treatment and sealing of all joints, corners,
junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing
treatment including preparation of surface as required for treatment
of roofs, balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with water proofing compound conforming to IS.
i 2645 and approved by Engineer-in-charge over the RCC slab
including adjoining walls upto 300 mm height including cleaning the
surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25
mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5
coarse sand) admixed with water proofing compound conforming to
IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer
of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed
with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating
similarly the adjoining walls upto 300 mm height including rounding
of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement
slurry using 2.75 kg/ sqm of cement admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-
(d) Finishing the surface with 20 mm thick jointless cement mortar
of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-
charge including laying glass fibre cloth of approved quality in top
layer of plaster and finally finishing the surface with trowel with neat
cement slurry and making pattern of 300x300 mm square 3 mm
(e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test.“All above
operations to be done in order and as directed and specified by the
Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra
TOTAL (Carried Over to Summary of Civil Works) 2,894,835.81
M 25.0 STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Providing and supplying aluminium extruded tubular and other
aluminium sections as per the architectural drawings and approved
shop drawings , the aluminium quality as per grade 6063 T5 or T6 as
per BS 1474, including super durable powder coating of 60-80
microns conforming to AAMA 2604 of required colour and shade as
1 25.1 approved by the Engineer-in-Charge. ( The item includes cost of Kg 1530.65 414.30 634,148.30
material such as cleats, sleeves, fasteners screws etc as desired.
necessary for fabrication of extruded aluminium frame work.
Nothing extra shall be paid on this account). The weight of
aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in
position semi (grid) unitized system of structural/ curtain wall glazing
2 25.2 (with open joints) for linear as well as curvilinear portions of the Sqm 695.75 3,510.50 2,442,430.38
building for all heights and all levels, including :
a) Structural analysis & design and preparation of shop drawings for
the specified design loads conforming to IS 875 part III (the system
must passed the proof test at 1.5 times design wind pressure
without any failure), including functional design of the aluminum
sections for fixing glazing panels of various thicknesses, aluminium
cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts,
bolts, clamps etc., structural and weather silicone sealants, flashings,
fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets
for water tightness, pressure equalization & drainage and protection
against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanized /
Aluminium alloy of 6005 T5 brackets of required sizes, sections and
profiles etc. to accommodate 3 Dimensional movement for
achieving perfect verticality and fixing structural glazing system
rigidly to the RCC/ masonry/structural steel framework of building
structure using stainless steel anchor fasteners/ bolts, nylon
separator to prevent bimetallic contacts with nuts and washers etc.
of stainless steel grade 316, of the required capacity and in required
c) Providing and filling, two part pump filled, structural silicone
sealant and one part weather silicone sealant compatible with the
structural silicone sealant of required bite size in a clean and
controlled factory / work shop environment , including double sided
spacer tape, setting blocks and backer rod, all of approved grade,
brand and manufacture, as per the approved sealant design, within
and all around the perimeter for holding glass
d) Providing and fixing in position flashings of solid aluminium sheet
1 mm thick and of sizes, shapes and profiles, as required as per the
site conditions, to seal the gap between the building structure and
all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the
curtain glazing system to make it watertight, by incorporating
principles of pressure equalization, providing suitable gutter profiles
at bottom (if required), making necessary holes of required sizes and
of required numbers etc. complete. This item includes cost of all
inputs of designing, labour for fabricating and installation of
aluminium grid, installation of glazed units, T&P, scaffolding and
other incidental charges including wastages etc., enabling temporary
structures and services, cranes or cradles etc. as described above
and as specified. The item includes the cost of getting all the
structural and functional design including shop drawings checked by
a structural designer, dully approved by Engineer-in-charge.
The item also includes the cost of all mock ups at site, cost of all
samples of the individual components for testing in an approved
laboratory, field tests on the assembled working structural glazing as
specified, cleaning and protection till the handing over of the
building for occupation. In the end, the Contractor shall provide a
water tight structural glazing having all the performance
characteristics etc. all complete as required, as per the Architectural
drawings, as per item description, as specified, as per the approved
shop drawings and as directed by the Engineer in-Charge.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Note:- 1. The cost of providing extruded aluminium frames, shadow
boxes, extruded aluminium section capping for fixing in the grooves
of the curtain glazing and vermin proof stainless steel wire mesh
shall be paid for separately under relevant items under this subhead.
However, for the purpose of payment, only the actual area of
structural/ curtain wall glazing (including width of grooves ) on the
external face shall be measured in sqm. up to two decimal places.
Providing, assembling and supplying vision glass panels (IGUs)
comprising of hermetically-sealed 6-12- 6 mm insulated glass
(double glazed) vision panel units of size and shape as required and
specified, comprising of an outer heat strengthened (as approved)
glass 6mm thick, of approved colour and shade with reflective soft
coating on surface # 2 of approved colour and shade, an inner heat
strengthened (as approved) clear float glass 6mm thick, spacer tube
12mm wide, desiccants, including primary seal and secondary seal
(structural silicone sealant) etc. all complete for the required
performances, as per the Architectural drawings, as per the
approved shop drawings, as specified and as directed by the
Engineer-in-Charge. The IGUs shall be assembled in the factory/
workshop of the glass processor. (Payment for fixing of IGU Panels
in the curtain glazing is included in cost of item No.1.8.16 above).
For payment, only the actual area of glass on face # 1 of the glass
panels (excluding the areas of the grooves and weather silicone
sealant) provided and fixed in position, shall be measured in sqm.
(To be fixed on extruded aluminium sections. and cost of aluminium
sections to be paid in relevant item)
(i) Coloured tinted float glass 6mm thick Heat Strengthened
substrate with reflective soft coating on face # 2, + 12mm Airgap +
6mm Heat Strengthened clear Glass of approved make having
i i properties as visible Light transmittance (VLT) of 25 to 35 %, Light Sqm 695.75 3,718.70 2,587,285.53
reflection internal 10 to 15%, light reflection external 10 to 20 %,
shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2
Extra for openable side / top hung vision glass panels
(IGUs/laminated glass) including providing and supplying at site all
accessories and hardware for the openable panels as specified and
of the approved make such as heavy duty stainless steel friction
hinges, min 4 -point cremone locking sets with stainless steel plates,
handles, buffers etc. including necessary stainless steel screws/
fasteners, nuts, bolts, washers etc. all complete as per the
Architectural drawings, as per the approved shop drawings, as
specified and as directed by the Engineer in- Charge..
TOTAL (Carried Over to Summary of Civil Works) 5,791,586.50 -
N 26.0 NEW TECHNOLOGIES AND MATERIALS
Providing & fixing in position Phenol bonded Bamboowood flooring
with planks of sizes 14mm thick, minimum 1800mm length and
minimum 100 mm wide, in approved colour, texture and finish,
having Performance Appraisal Certificate (PAC) issued by Building
Materials & Technology Promotion Council (BMTPC). The flooring
shall be fixed with tongue and groove interlocking system, with
underlayment of 4mm thick expanded polyethylene foam sheets
having density 40kg/cum, over prepared surface with necessary
quarter round planks of size 1900mm x 18mm and door reducer of
size 1900mm x 44mm, wherever required. The bamboowood planks
shall have minimum density of 1000 Kg/cum & minimum Hardness
1000 Kgf. with Eco friendly UV coating, all complete as per direction
of the Engineer-in-charge.
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
SITC of Micro Perforated (Perfoaudile™) 16mm thick Wooden
Acoustic Wall Panels of size 600 x 2420mm, perforation diameter
will be 01-1.5 mm at a distance of 03 mm c/c as per acoustic
design/Architects approval, The micro perforated acoustic panels
top sheet will be of 0.5mm thick Mica laminate in desired shade as
per Engineer In charge / Architect’s approval and base made out of
16mm thick high density MDF board of 700-750 kg density with
10mm hole diameter perforation, micro perforated wooden acoustic
panels to be backed with black acoustic fleece. All joints of Micro
Perforated Acoustic Panels should have dowel connection to avoid
any sagging /unevenness. All Micro Perforated Acoustic Panels
should be fixed on GI ‘Z’ clamp made out of 0.7 mm thick GI sheet of
size 30 mm x 30 mm collar and 50 mm high to match with the
2 MR installed GI frame. The 50mm GI channel made out of GI sheet, 0.5 Sqm 633.47 12,282.00 7,780,327.67
mm thick. The GI Channel grid size will be – 600 x 900mm fixed to
wall using all screws of Stainless steel. Cavity of grid shall be filled
with Tissue fiber paper laminated Rockwool density 64 kg/m3
confirming to IS 8183 to achieve the best NRC value and finally
Micro Perforated Acoustic Panels fixed on GI Channel grid as final
finish. Micro Perforated Wall panel having 0.85 NRC value as per test
conducted by Prasar Bharti. The edges of the Micro Perforated
Acoustic Panel shall be Square edge at all four ends as per choice. All
makes and models of all items/samples should be approved by the
engineer-in-charge / consultant prior to the installation.
Technical Parameters Micro Perforated Acoustic Panels
Density - 700-750kg/m3
Fire Retardant – Class (A)
NRC Value – 0.85 with NRC System.
Providing and fixing mineral fibre false ceiling tiles at all heights of
size 595X595mm of approved texture, design and pattern. The tiles
should have Humidity Resistance (RH) of 99%, Light Reflectance >
85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire
Performance as per (BS 476 pt - 6 &7)in true horizontal level
suspended on interlocking T-Grid of hot dipped all round galvanized
iron section of 0.33 mm thick (galvanized @120 gsm) comprising of
main T runners of 15x32 mm of length 3000 mm, cross T of size
15x32mm of length 1200 mm and secondary intermediate cross T of
size 15x32 mm of length 600 mm to form grid module of size
600x600 mm suspended from ceiling using galvanized mild steel
item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6
dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000
mm length and L-shape level adjuster of size 85x25x2 mm, spaced at
1200 mm centre to centre along main ‘T’. The system should rest on
periphery walls /partitions with the help of GI perimeter wall angle
of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to
the wall with help of plastic rawl plug at 450 mm centre to centre &
40 mm long dry wall S.S. screws. The exposed bottom portion of all T-
sections used in false ceiling support system shall be pre-painted
with polyester baked paint, for all heights. The work shall be carried
out as per specifications, drawings and as per directions of the
engineer-incharge.
With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC
DSR-2023 DESCRIPTION UNIT QTY. DSR-2023 Amount NDSR RATE NDSR Amount
Aluminium Rafters
Providing & Fixing 2mm thick hollow alluminium louvers of size
1 NS 100mm x 150mm or 150mm x 200mm with all necessary accessories Sqm 229.93 8,500.00 1,954,362.50
Providing Design/Fabrication of SS Letter cut out on SS Grade 202
Steel.Corrosion Resistance/Hardened/ High Strength/Back lit High
Intensity LED Illuminated.Approved Design (TAMS BUILDING,
MAITHAN in English)Preparation of Letter and Fonts on
AUTOCAD.Plasma Cutting on Stainless Steel with Nitrogen to give
excellent surface finish for edge .Griding and Fabrication of
Letterswelding.Overall Size: 1200mmx20000mm
Providing and fixing of signages, modular curved frame
technology,of various widths and lengths, to form suggested
usages,made of aluminium extruded sections , duly anodised ,all
signages shall be provided with 0.6-0.8mm polycarbonate protecting
film over the prints, of appropriate size,
a ROOM NAME PLATE (80 mm x 300 mm) Each 18.00 1,650.00 29,700.00
BOTH SIDE- WALL PROJECTED LADIES TOILET (200 mm x 200 mm)
BOTH SIDE-WALL PROJECTED GENTS TOILET (200 mm x 200 mm)
d DOOR PLATE LADIES TOILET (80 mm x 300 mm) Each 1.00 1,860.00 1,860.00
e DOOR PLATE GENTS TOILET (80 mm x300 mm) Each 1.00 1,675.00 1,675.00
f ELECTRICAL PANEL (80 mm x 300 mm) Each 1.00 1,720.00 1,720.00
g DRINKING WATER (200 mm x 200 mm) Each 1.00 2,690.00 2,690.00
h AUTHORISED PERSONAL ONLY (80 mm x 300 mm) Each 3.00 1,700.00 5,100.00
Providing and fixing of signages,customised to the architect's
design,the signage to be made of 10 mm casted clear acrylic sheet
duly cut by laser, all text to be of 2 mm thick acrylic duly laser cut,
partially housed and pasted on to engraved surface of the text in the
4 NS clear acrylic base, the 10mm acrylic sheet to be fixed on 25x25mm
section of teak wood with help of crafted SS pins, and further fixed
to the priscribed location with the help of wooden dowels,and
required adhesive,as per drawing.
b FLOOR LEVEL (600 mm x 300 mm) Each 2.00 9,198.00 18,396.00
c CONFERENCE ROOM (400 mm x 400 mm) Each 1.00 8,176.00 8,176.00
TOTAL (Carried Over to Summary of Civil Works) 11,431,974.53 10,666,255.17
ALL SUB-HEAD TOTAL 123,044,238.33 14,142,723.37
GRAND TOTAL 137,186,961.70
GRAND TOTAL 137,186,961.70
PROPOSED CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON
ABSTRACT OF ELECTRICAL WORKS ESTIMATE
SL. NO. DESCRIPTION
1 SUBHEAD :1_WIRING 2,820,367 0
2 SUBHEAD :2_LIGHT FITTINGS AND FANS 1,574,928 121,034
3 SUBHEAD :3_MCB ,DB'S 167,509 0
4 SUBHEAD :4_LT CABLE, LAYING & TERMINATIONS 184,149 1,680,147
5 SUBHEAD :5_CABLE TRAY 125,071 0
6 SUBHEAD :6_11KV COMPACT SUB-STATION 0 9,717,615
7 SUBHEAD :7_HT CABLE, LAYING & TERMINATIONS 171,694 479,597
8 SUBHEAD :8_ELE. MEDIUM VOLTAGE PANELS 320,033 5,235,851
9 SUBHEAD :9_UPS 208,893 0
10 SUBHEAD :10_EARTHING 338,314 0
11 SUBHEAD :11_LIGHTNING PROTECTION SYSTEM 0 855,611
12 SUBHEAD :12_SOLAR PV POWER GENERATION 3,799,600 0
13 SUBHEAD :13_FIRE ALARM SYSTEM 2,233,768 27,209
14 SUBHEAD :14_PUBLIC ADDRESS SYSTEM 972,152 0
15 SUBHEAD :15_DATA & VOICE SYSTEM 5,994,320 0
16 SUBHEAD :16_CCTV SYSTEM 2,310,549 181,827
17 SUBHEAD :17_ACCESS CONTROL SYSTEM 256,451 49,452
18 SUBHEAD :18_SECURITY SYSTEM 0 392,491
19 SUBHEAD :19_DIESEL GENERATOR SET 2,433,003 0
20 SUBHEAD :20_LIFT 3,368,451 0
21 SUBHEAD :21_EXTERNAL LIGHTING 232,158 1,858,313
22 SUBHEAD :22_MISCELLANEOUS ITEMS 110,895 0
GRAND TOTAL 48,221,453
GRAND TOTAL 48,221,453
Digitally signed by SUPARNA
PROPOSED CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON SUBSTATION
ESTIMATE-ELECTRICAL WORKS
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
SUBHEAD :1_WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed
1 1.10 medium class PVC conduit, with modular switch, modular plate, suitable GI box and
earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single
core cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point
( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper
3 1.55 conductor single core cable in surface/ recessed PVC conduit, and earthing the point with
1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as
Wiring for circuit/ submain wiring along with earth wire with the following sizes of
5 1.7 FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel
conduit as required.
6 1.7.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (For UPS) Meter 10 1253 12530
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor,
7 1.17 single core cable in the existing surface/ recessed steel/ PVC conduit as required.
8 1.17.3 3 X 1.5 sq. mm (For circuit wiring) Meter 600 104 62400
9 1.17.12 3 X 2.5 sq. mm (For circuit wiring) Meter 1500 148 222000
10 1.17.21 3 X 4.0 sq. mm (For power point wiring) Meter 2050 222 455100
Supplying and fixing of following sizes of medium class PVC conduit along with
11 1.21 accessories in surface/recess including cutting the wall and making good the same in case
of recessed conduit as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box
excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface
14 1.31 or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A Each 50 545 27250
modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface
15 1.32 or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet Each 49 659 32291
and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface
or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2
nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in
non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface
17 1.57 or in recess including providing and fixing 25 A modular socket outlet and 25 A modular Each 4 807 3228
SP MCB, "C" curve including connections, painting etc. as required.
Supplying & fixing of 20 A, 240 V, SPN Insustrial type socket outlet, with 2 pole and
earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket outlet and
complete with connections, testing and comissioning etc.as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing
19 1.25 modular plate switch box including connections but excluding modular plate etc. as Each 114 402 45828
20 TOTAL OF SUBHEAD :1 2820367 0
21 SUBHEAD :2_LIGHT FITTINGS AND FANS
Brush Less Direct Current (BLDC) Fan without Remote
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct
Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30
cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body
Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM
(tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%,
22 9.2 suitable for operation with regulator for speed control and all remaining accessories
including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply,
Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
23 9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) Each 114 2695 307230
Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required
26 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes Each 20 260 5200
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt)
Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter
(Round /square/Rectangular) SMD type of following body material with PMMA and
prismatic diffuser and construction as per IS : 10322 with driver as per the requirement
with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,
Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short &
Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver &
electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial
Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT
3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation
27 8.3 Color Matching) <3, Maximum power consumption should not more than the specified
rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external
connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core
cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen
efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for
LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium
housing such that LED junction temperature shall not rise above 90°C).
28 Powder coated die cast /Extruded aluminum Body including trim .
LED Batten light (System lumen efficacy ≥120 <135 lm/Watt)
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light
of following body material and construction as per IS : 10322 with driver (Replaceable) as
per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt,
frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5
KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,
Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical
circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till
ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard
33 8.10 Deviation Colour Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.
complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required with Minimum
5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 &
LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.
Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
(Thermal management: heat sink of aluminium housing such that LED junction
temperature shall not rise above 90°C).
Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
LED Flood Light, powder coated pressure die cast aluminum (System lumen
efficacy >135 lm/Watt)
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure
die cast aluminium body with built in or separate driver as per the requirement with
Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60
hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per
IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95,
IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per
CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project
requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of
36 8.17 minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per
LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As
per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power
consumption should not more than the specified rating and Fixture shall be of relevant
BIS standard complete in all respect i/c external connections with 1.5 sq.mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS
shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as
per requirement. (Thermal management: heat sink of aluminium housing such that LED
junction temperature shall not rise above 90°C).
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body
material and construction as per IS : 10322 with driver as per the requirement with Driver
efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp
range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &
Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver &
electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen
maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI
Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption
38 8.8 should not more than the specified rating and Fixture shall be of relevant BIS standard
and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5
sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum
housing such that LED junction temperature shall not rise above 90°C).
Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm)
Supply and installation of Energy saving new generation 10W LED 6500K bulkhead
40 MR luminaire with opal diffuser etc with all fixing accessories as required of Hevells Cate. Each 6 1425 8552
Ref RUGBYGENXFTS10WLED865SSYMBOPC or apporoved equivalent.
Supply and installation of Flexiible LED strips with optimum brightness & uniformity of
41 MR light for perfect cove lighting, with all fixing accessories as required of Cate. Ref. Each 12 1145 13734
FLEXISTRIP5MIP2024V/2ALED865MOD V1or apporoved equivalent.
Supply and installation of Driver for Flexiible LED strips with all fixing accessories as
42 MR required of Cate. Ref. Constant Voltage Driver24V2Aupto 48W V1 or apporoved Each 12 1209 14512
Supply and installation of 450 mm, 230 V A.C. wall mounted Air circulator, heavy duty
43 MR fan including fixing the bracket, making connection, testing, commissioning etc as Each 1 7226 7226
required.of Cate. Ref. HAVELLS : FHWV3TFSLB18 or apporoved equivalent.
Supply of sizes 200 mm, 230 v A.C.Plastic body exhaust fan complete with
44 MR motor,blades,frame, bracket, lover/shutter etc. as required of Cate. Ref. HAVELLS : Each 8 2435 19478
FHVDXHSWHT08 or apporoved equivalent.
Supply of sizes 230 mm, 230 v A.C. heavay duty exhaust fan complete with
45 MR motor,blades,frame, bracket, lover/shutter etc. as required of Cate. Ref. HAVELLS : Each 7 2691 18835
FHVVEMTDBB09 or apporoved equivalent.
Supply of sizes 450 mm, 230 v A.C. heavay duty exhaust fan complete with
46 MR motor,blades,frame, bracket, lover/shutter etc. as required of Cate. Ref. HAVELLS : Each 5 7740 38698
FHEHDSPGRY18 or apporoved equivalent.
47 TOTAL OF SUBHEAD :2 1574928 121034
48 SUBHEAD :3_MCB ,DB'S
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,
MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as
required. (But without MCB/RCCB/Isolator
53 2.3.1 6 way, Double door Each 1 2390 2390
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit
54 2.10 breaker suitable for inductive load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as required
55 2.10.1 Single pole Each 200 285 57000
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB
complete with connections, testing and commissioning etc. as required
Supplying and fixing following rating, double pole, 230 V, isolator in the existing MCB
DB complete with connections, testing and commissioning etc. as required
Supplying and fixing following rating,four pole, (three phase and neutral), 415 volts,
residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole
62 2.24 and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete
with testing and commissioning etc.as required.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
63 2.24.2 For 6 way, Double door TPN MCBDB Each 3 1223 3669
64 2.24.3 For 8 way, Double door TPN MCBDB Each 6 1448 8688
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole
65 2.23 and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete
with testing and commissioning etc.as required.
66 2.23.1 For 6 way, Double door SPN MCBDB Each 1 834 834
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as
68 TOTAL OF SUBHEAD :3 167509 0
69 SUBHEAD :4_LT CABLE, LAYING & TERMINATIONS
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size in the existing RCC/ HUME/ metal pipe as required.
73 10.5.3 Above 95 sq. mm and upto 185 sq. mm Meter 367 97 35599
74 10.5.4 Above 185 sq. mm and upto 400 sq. mm Meter 305 170 51765
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable
of 1.1 KV grade of following size on cable tray as required.
76 10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Meter 391 53 20736
77 10.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Meter 58 109 6295
78 10.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Meter 32 138 4416
79 CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs
80 11.1 for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV grade as required.
86 SUPPLY OF CABLE
Supply of XLPE insulated and PVC sheathed power cable of 1.1 kV grade, 1.1 kV, multi
core, aluminum,armored , underground, Conforming to IS 7098-2
91 MR 4c x 25 sqmm Meter 26 366 9599
93 MR 4c x 6 sqmm Meter 95 190 17958
Supply and termination of XLPE insulated & PVC sheathed Armoured copper cables of
94 1.1 KV grade with copper conductor as per IS 7098 Part-I -1988 including all labour
charges, giving connections etc., complete as required.
95 MR 2 Core, 6 Sq.mm (For Submain) Meter 120 340 40771
96 MR 3 Core, 6 Sq.mm (For Submain) Meter 10 466 4659
97 MR 4 Core, 6 Sq.mm (For Submain) Meter 30 609 18278
98 MR 4 Core, 10 Sq.mm (For Submain) Meter 90 967 87070
99 TOTAL OF SUBHEAD :4 184149 1680147
100 SUBHEAD :5_CABLE TRAY
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable
tray (Galvanisation thickness not less than 50 microns) with perforation not more than
17.5%, in convenient sections, joined with connectors, suspended from the ceiling with
G.I. suspenders including G.I. bolts & nuts, etc. as required.
102 4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness Meter 50 803 40150
103 4.6.7 600 mm width X 50 mm depth X 2.0 mm thickness Meter 35 1925 67375
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable
tray "bends" (galvanisation not less than 50 microns) with perforation not more than
17.5%, in convenient sections, joined with connectors, suspended from the ceiling with
G.I. suspenders including G.I. bolts & nuts, etc. as required.
105 4.7.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 7 1368 9576
106 4.7.7 600 mm width X 50 mm depth X 2.0 mm thickness Each 2 3985 7970
107 TOTAL OF SUBHEAD :5 125071 0
108 SUBHEAD :6_11KV COMPACT SUB-STATION
Design, Supply, Erection, Testing and Commissioning of 11/0.433 KV, Smart Compact
Substation (CSS) on existing foundation along with 11kV 4 Way (3LBS+1VCB) RMU,
Distribution Transformer and LT Switchgears complete set, type tested in line with latest
IEC standards of IEC 62271-202 only.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Outdoor type enclosure having modular construction of 2 mm Galvanised Sheet Steel.
The Enclosure shall have IP54 degree of protection for MV & LT switchgear
compartment & IP34 degree of protection for Transformer compartment. Each
compartment will be provided with the door and pad locking arrangement. The
110 Compartment illumination lamp with door operated switch shall be provided for each
compartment. Interconnection Between MV switchgear & Transformer using XLPE
single core cable & Interconnection between Transformer & LT switchgear using
Busbars. Internal earthing connections. All metallic components shall be earthed to a
common earthing point.
PSS Enclosure should be Internal Arc Tested for IAC A & B both conditions for 21 kA
111 for 1 sec, as per IEC 62271-202.
PSS Enclosure shall be K10 class.
11/0.415kV, 500kVA Compact Substation :11/0.415kV Outdoor type Compact Sub-
Station, equipped with 500KVA 11KV/433V, DYn11 Oil filled hermatically sealed
transformer, 4 Way 11kV Ring Main Unit consisting of 3 nos. 630A at 11kV load
112 breaking switch with 1 nos. tee-off as SF6 insulated 200A Vacuum Circuit Breaker &
800A 415V 50KA 4P Fixed Manual Air Circuit Breaker with numerical overcurrent and
earthfault protection as secondary side control as detailed below. The detail bill of
material for each Compact Substation shall be as under:
PSS shall have bucket type lifting arrangement connected from base of PSS for all PSS
114 HT Switchgear
4way Non - Extensible unit RMU with 3no. 630 A load break switch and 1 no. 200A
Tee off with VCB self powered with O/C + E.F. Relay, with Motorized LBS & VCB.
116 Each Load Break Switch (LBS) consists of :
Manually operated 630A load breaker switch with built-in earth switch having full
making capacity.
118 Mechanical position indicator. Switch ON/OFF/EARTHED.
119 Live Cable Indication.
120 Cable compartment cover interlocked with earth switch.
Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable and must be site
replacable type.
122 Cable termination cover boots (Push on type)
123 Each VCB Feeder consists of following:
Motorized 200A VCB spring charging arrangement and manual close & open push
buttons, ON / OFF indication.
Self powered O/C & E/F relay type CSDPR with single core cast resin type
CT.(Protection Core - 1.2VA & CL-5P10)
126 Motorized 200A load breaker switch with built in earth switch.
127 Mechanical position indicator. Switch ON/OFF/EARTHED.
128 Live Cable Indication and VCB operating sequence must be O-0.3Sec-CO-3MIN-CO
129 Cable compartment cover interlocked with earth switch.
Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable and must be site
replacable type.
131 Cable termination cover boots (Push on type)
132 VCB shall have line side ES having own making capacity independent of breaker.
133 VCB shall have 50 nos. short circuit breaking operations at 21 kA.
134 BUS PT For Metering
Air Insulated enclosure with necessary bus connection via bushing. VT’s from the
135 manufacturer and according to IS 3156 shall be accepted.
11KV/rt3/110V/rt3; 25VA class 0.5. Single phase bus PT for metering - 3 Nos.
136 TRANSFORMER-
500KVA capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per
BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz,
Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer
(Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain
Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications
with On Load Tap Changer OLTC and facility for remote and manual operation of OLTC
HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side
suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking
arrangement on LV side including supplying and laying of copper conductor multicore
control cable from transformer to HT breaker/panel for safety tripping, complete with all
accessories and safety provisions as per relevant IS Code including first filling of filtered
dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories
and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI
Marked and as per CPWD specifications complete in all respects etc as required at site.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Design ambient condition :
a) air temperature 50 deg C,
b) Relative Humidity 90 % Max,
c) Seismic Zone as per location of site,
d) Altitude as per location/site.
Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running
measured as per IEC 551 / NEMA standard.The transformer should have QR code which
should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc.
139 Marking Each transformer shall be provided with rating plate made of anodized
aluminum/ stainless steel material securely fixed on the outer body, easily accessible, as
per IS: 1180. The entries on the rating plate shall be indelibly marked.
The maximum flux density in any part of the core and yoke at rated voltage and frequency
shall be such that the flux density with + 12.5 percent combined voltage and frequency
variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible
temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40
dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted
140 with varnish or liquid resistant paint. For external surfaces one coat of thermo setting
powder paint or one coat of epoxy primer followed by two coats of polyurethane base
paint shallbe used. IS: 1180 shall be referred to for paint thickness for normal to medium
corrosive atmosphere. For highly polluted atmosphere and special application external
paint work shall be as per direction of Engineer-in-Charge.
141 Fitting and Accessories : The following fittings shall be provided:-
142 a) Two earthing terminals with the earthing symbol
b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating
144 c) Air release device (for non-sealed type transformers)
145 d) Rating and terminal marking plates;
146 e) Silica gel breather
f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug
for three phase transformers;
148 g) Thermometer pocket with cap;
h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type
transformers without conservator);
150 i) Lifting lugs for the complete transformer as well as for core and winding assembly;
151 j) Pressure relief device or explosion vent;
152 k) One filter valve on the upper side of the tank;
153 l) Unidirectional flat rollers;
154 m) Inspection hole;
n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to
156 o) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos.
157 p) Bird guard;
q) Oil temperature indicator and winding temperature indicators for transformers with
suitable tripping mechanism above permissible limit
159 r) Additional Neutral separately brought out on bushing for earthing.
160 s) Non return valve (for conducting pressure test);
161 t) Pressure relief device or explosion vent
162 u). Monogram Plate
163 v) Inspection cover
164 w). Detachable type radiators with top and bottom shutoff valve.
165 x) Oil Conservator with Oil level indicator, minimum level marking and drain plug.
y) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all
Transformer manufacturer shall have In-House Dust free Core cutting Vapor Phased
Drying NABL accredited test facility.
168 LT Switchgear
800Amps 415V 50KA 4P Fixed Manual Air Circuit Breaker with numerical overcurrent
and earth fault protection.
11KV OUTDOOR UNITISED SUB-STATION above & as per SLD
PSS enclosure, RMU, Vacum Interrupter, ACB shall be of same make and License
170 MR partner, Authorized system house make PSS are not accepted. PSS Enclosure must Each 1 5398675 5398675
be type tested for 21KA/1sec with IAC-A&B classification.
Approved PSS Manufacturer - Schneider/ABB/Siemens
Design, Supply, Erection, Testing and Commissioning of 11/0.433 KV, Smart Compact
Substation (CSS) on existing foundation along with 11kV 2 Way (1LBS+1VCB) RMU,
Distribution Transformer and LT Switchgears complete set, type tested in line with latest
IEC standards of IEC 62271-202 only.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Outdoor type enclosure having modular construction of 2 mm Galvanised Sheet Steel.
The Enclosure shall have IP54 degree of protection for MV & LT switchgear
compartment & IP34 degree of protection for Transformer compartment. Each
compartment will be provided with the door and pad locking arrangement. The
172 Compartment illumination lamp with door operated switch shall be provided for each
compartment. Interconnection Between MV switchgear & Transformer using XLPE
single core cable & Interconnection between Transformer & LT switchgear using
Busbars. Internal earthing connections. All metallic components shall be earthed to a
common earthing point.
PSS Enclosure should be Internal Arc Tested for IAC A & B both conditions for 21 kA
173 for 1 sec, as per IEC 62271-202.
PSS Enclosure shall be K10 class.
11/0.415kV, 500kVA Compact Substation :11/0.415kV Outdoor type Compact Sub-
Station, equipped with 500KVA 11KV/433V, DYn11 Oil filled hermatically sealed
transformer, 2 Way 11kV Ring Main Unit consisting of 1 nos. 630A at 11kV load
174 breaking switch with 1 nos. tee-off as SF6 insulated 200A Vacuum Circuit Breaker &
800A 415V 50KA 4P Fixed Manual Air Circuit Breaker with numerical overcurrent and
earthfault protection as secondary side control as detailed below. The detail bill of
material for each Compact Substation shall be as under:
PSS shall have bucket type lifting arrangement connected from base of PSS for all PSS
176 HT Switchgear
2way Non - Extensible unit RMU with 1no. 630 A load break switch and 1 no. 200A
Tee off with VCB self powered with O/C + E.F. Relay, with Motorized LBS & VCB.
178 Each Load Break Switch (LBS) consists of :
Manually operated 630A load breaker switch with built-in earth switch having full
making capacity.
180 Mechanical position indicator. Switch ON/OFF/EARTHED.
181 Live Cable Indication.
182 Cable compartment cover interlocked with earth switch.
Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable and must be site
replacable type.
184 Cable termination cover boots (Push on type)
185 Each VCB Feeder consists of following:
Motorized 200A VCB spring charging arrangement and manual close & open push
buttons, ON / OFF indication.
Self powered O/C & E/F relay type CSDPR with single core cast resin type
CT.(Protection Core - 1.2VA & CL-5P10)
188 Motorized 200A load breaker switch with built in earth switch.
189 Mechanical position indicator. Switch ON/OFF/EARTHED.
190 Live Cable Indication and VCB operating sequence must be O-0.3Sec-CO-3MIN-CO
191 Cable compartment cover interlocked with earth switch.
Cable termination bushings suitable for 3 no. 1CX300mm2 XLPE cable and must be site
replacable type.
193 Cable termination cover boots (Push on type)
194 VCB shall have line side ES having own making capacity independent of breaker.
195 VCB shall have 50 nos. short circuit breaking operations at 21 kA.
196 TRANSFORMER-
500KVA capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per
BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz,
Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer
(Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain
Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications
with On Load Tap Changer OLTC and facility for remote and manual operation of OLTC
HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side
suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking
arrangement on LV side including supplying and laying of copper conductor multicore
control cable from transformer to HT breaker/panel for safety tripping, complete with all
accessories and safety provisions as per relevant IS Code including first filling of filtered
dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories
and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and duly ISI
Marked and as per CPWD specifications complete in all respects etc as required at site.
Design ambient condition :
a) air temperature 50 deg C,
b) Relative Humidity 90 % Max,
c) Seismic Zone as per location of site,
d) Altitude as per location/site.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running
measured as per IEC 551 / NEMA standard.The transformer should have QR code which
should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc.
199 Marking Each transformer shall be provided with rating plate made of anodized
aluminum/ stainless steel material securely fixed on the outer body, easily accessible, as
per IS: 1180. The entries on the rating plate shall be indelibly marked.
The maximum flux density in any part of the core and yoke at rated voltage and frequency
shall be such that the flux density with + 12.5 percent combined voltage and frequency
variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible
temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40
dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted
200 with varnish or liquid resistant paint. For external surfaces one coat of thermo setting
powder paint or one coat of epoxy primer followed by two coats of polyurethane base
paint shallbe used. IS: 1180 shall be referred to for paint thickness for normal to medium
corrosive atmosphere. For highly polluted atmosphere and special application external
paint work shall be as per direction of Engineer-in-Charge.
201 Fitting and Accessories : The following fittings shall be provided:-
202 a) Two earthing terminals with the earthing symbol
b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating
204 c) Air release device (for non-sealed type transformers)
205 d) Rating and terminal marking plates;
206 e) Silica gel breather
f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug
for three phase transformers;
208 g) Thermometer pocket with cap;
h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type
transformers without conservator);
210 i) Lifting lugs for the complete transformer as well as for core and winding assembly;
211 j) Pressure relief device or explosion vent;
212 k) One filter valve on the upper side of the tank;
213 l) Unidirectional flat rollers;
214 m) Inspection hole;
n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to
216 o) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos.
217 p) Bird guard;
q) Oil temperature indicator and winding temperature indicators for transformers with
suitable tripping mechanism above permissible limit
219 r) Additional Neutral separately brought out on bushing for earthing.
220 s) Non return valve (for conducting pressure test);
221 t) Pressure relief device or explosion vent
222 u). Monogram Plate
223 v) Inspection cover
224 w). Detachable type radiators with top and bottom shutoff valve.
225 x) Oil Conservator with Oil level indicator, minimum level marking and drain plug.
y) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all
Transformer manufacturer shall have In-House Dust free Core cutting Vapor Phased
Drying NABL accredited test facility.
228 LT Switchgear
800Amps 415V 50KA 4P Fixed Manual Air Circuit Breaker with numerical overcurrent
and earth fault protection.
11KV OUTDOOR UNITISED SUB-STATION above & as per SLD
PSS enclosure, RMU, Vacum Interrupter, ACB shall be of same make and License
230 MR partner, Authorized system house make PSS are not accepted. PSS Enclosure must Each 1 4318940 4318940
be type tested for 21KA/1sec with IAC-A&B classification.
Approved PSS Manufacturer - Schneider/ABB/Siemens
231 TOTAL OF SUBHEAD :6 0 9717615
232 SUBHEAD :7_HT CABLE, LAYING & TERMINATIONS
233 Supply of Cable
Supplying of the following sizes of 11 KV Alum. (E), Armoured XLPE HT power cable
as per IS7098(part-2)-1985 amended uptodate, as per specifications.
235 MR 11 KV (E), 3C x 300 Sq. mm XLPE Aluminium cable Armoured Meter 110 4360 479597
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV
grade of following size in the existing RCC/ HUME/ METAL pipe as required.
238 22.3.2 Above 120 sq. mm and upto 400 sq. mm Meter 110 170 18700
239 End Termination
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying and making indoor cable end termination with heat shrinkable jointing kit
240 23.4 complete with all accessories including lugs suitable for following size of 3 core, XLPE
aluminium conductor cable of 11 KV grade as required:
Supplying and making outdoor cable end termination with heat shrinkable jointing kit
242 23.5 complete with all accessories including lugs suitable for following size of 3 core, XLPE
aluminium conductor cable of 11 KV grade as required:
244 TOTAL OF SUBHEAD :7 171694 479597
245 SUBHEAD :8_ELE. MEDIUM VOLTAGE PANELS
NOTE: Contactor will submit the GA Drawings of Panel for Approvel from
Clint/Consultant before order the panel.
247 MAIN LT PANEL
Design, Fabrication, Shifting, Supply, Erection,Testing and commisioning of 415V, 3
Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor
type floor mounted, free standing extendible type Main LT Panel compartmentalized
design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars,
Electrical interlocks as per the various status of all the equipments indicated on the
drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears,
complete with earth Bus bar throughout the length of the panel, terminal arrangement for
Cables/ busducts, incomings / Outgoings from Top / Bottom as per drawings and as
approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be
accommodated in a modular multi-tier arrangement, detachable gland plates, adequate
size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate, including
PVC insulated copper FRLS wires of minimum 1.5sq.mm & 2.5sq.mm for CT's etc.
complete as required as per specifications and drawing attached.
249 INCOMER FROM PSS-01 (500KVA)
1 Nos. 800Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
251 1 Nos. 800Amps, 415V FP CONTACTOR (AC-1 DUTY).
Digital Multifunction energy meter with RS485 showing V, A, PF, KVAR, KWH etc.
current transformers of 800/5A ratio, 10 VA Class 1.0 metering.
253 One (1) Set of Phase Indication & ON/OFF/TRIP Lamp with 2A SP MCB.
254 Control MCB'S, control terminals & wiring as required.
Under/ Over voltage, Master trip relays along with current transformers of 800/5A ratio,
10 VA class-5P10 protection - 1 set
256 Suitable arrangement to receive incoming armored cables.
257 Ameter with ASS
258 Voltmeter with VSS
259 ON/OFF/TRIP Indication
260 Open/Close Push button
261 Auto/Manual selector switch
262 APFC relay
263 INCOMER FROM PSS-02 (500KVA)
1 Nos. 800Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
265 1 Nos. 800Amps, 415V FP CONTACTOR (AC-1 DUTY).
Digital Multifunction energy meter with RS485 showing V, A, PF, KVAR, KWH etc.
current transformers of 800/5A ratio, 10 VA Class 1.0 metering.
267 One (1) Set of Phase Indication & ON/OFF/TRIP Lamp with 2A SP MCB.
268 Control MCB'S, control terminals & wiring as required.
Under/ Over voltage, Master trip relays along with current transformers of 800/5A ratio,
10 VA class-5P10 protection - 1 set
270 Suitable arrangement to receive incoming armored cables.
271 Ameter with ASS
272 Voltmeter with VSS
273 ON/OFF/TRIP Indication
274 Open/Close Push button
275 Auto/Manual selector switch
276 APFC relay
277 BUS COUPLER
1 Nos. 800Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
279 1 Nos. 800Amps, 415V FP CONTACTOR (AC-1 DUTY).
280 ON/OFF Indication
281 Open/Close Push button
282 Auto/Manual selector switch
283 INCOMER FROM 125 KVA DG PANEL
284 Incomer from DG Set shall be provided with the following:
1 Nos. 200Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
286 1 Nos. 200Amps, 415V FP CONTACTOR (AC-1 DUTY).
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Digital Multifunction energy meter with RS485 showing V, A, PF, KVAR, KWH etc.
current transformers of 200/5A ratio, 10 VA Class 1.0 metering.
288 Control MCB'S, control terminals & wiring as required.
Under/ Over voltage, Master trip relays along with current transformers of 200/5A ratio,
10 VA class-5P10 protection - 1 set
290 Suitable arrangement to receive incoming armored cables.
291 Ameter with ASS
292 Voltmeter with VSS
293 ON/OFF/TRIP Indication
294 Open/Close Push button
295 Auto/Manual selector switch
296 Reverse power Protection Relay.
297 INTERLOCKING.
298 DG Incomer, and AMF logic, interlocking with main incomers & Bus-Couplers.
1000 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP insulators.
2 Nos. 630Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.(MDB-HVAC)
2 Nos. 320Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.(APFC PANEL)
2 Nos. 250Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.(FIRE PANEL)
2 Nos. 160Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.(MDB-01)
2 Nos. 63Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.(PLUMBING)
4 Nos. 40Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.(BOREWELL, LPDB, FEEDER PILLAR)
12 Nos. Three Phase Dual Type Digital Energy Meter with RS-485 Port & necessary
309 14 Set of LED ON/OFF Indication Lamp with 2A Fuse.
310 MR MAIN LT PANEL above & as per SLD Set 1 2443800 2443800
Automatic Power Factor Correction (APFC) System
Supply, Installation, testing and commissioning of Automatic Power Factor
Correction (APFC) panel, indoor type floor mounted free standing totally enclosed,
extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for
Ambient temperature -5°C to +40°C, fabricated in compartmentalized designed made of
CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c
cleaning & finishing complete with 9 tank process for powder coated of approved shade
( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section
(switch gear and control accessories) and rear section capacitor and reactor, front and rear
access, having suitable current carrying capacity, extensible TPN Aluminum alloy bus bar
311 25.1 of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section,
fabrication shall be done in transportable section, entire panel shall have common copper
earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals
provided on the body of capacitor bank shall also be bonded to the main capacitor panel
earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper
conductor cable, forced ventilation for maintaining temperature rise not more than 5°C
from ambient, interconnections, connections with 14% detuned reactor and heavy duty
525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -
1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as
per below details
Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA
breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along
with required Instruments and accessories with extended rotary handle and door
interlocking arrangement. Current rating of the Incomer in ampere shall be APFC
Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.
(B) Instruments & Indications
i) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8
stages for capacity below 100 KVAR and 12 stages 100 KVAR & above) with
Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per
approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi,
Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT's
accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.
ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual
iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR,
THD-V & I, Frequency.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
iv) Suitable rating control transformer shall be provided for control and
indication circuit.
v) All components like control transformer, meter, relay and indicating lamp shall be
protected by using suitable rating individual MCB's.
vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade,
PVC insulated multi stranded copper control wire.
319 1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of
incomer rating as per CPWD specification.
(D) Outgoings (APFC Section)
Selection of the capacitors combinations shall be for continuous rating and each capacitor
bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty
contactor, the capacitor shall be mounted on channel with base of perforated M S Powder
coated sheet, connections inter connections etc. and other features as per CPWD
Specifications and relevant IS Code having following:
(i) Capacitor bank ratings & stages shall be as per the technical specifications sheet of
(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release
(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get
rated output at 415 Volts.
(iv) 14% Detuned Reactor of class H insulation & 150% linearity in series with
(Note: Technical specifications sheet for selection of the capacitors combinations shall be
provided by the NIT Approving Authority with due consideration of number of capacitors
i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR.....for smooth correction).
326 25.1.4 125 KVAR above & as per SLD Set 1 320033 320033
Fabrication, supply, installation, testing and commissionings of cubicle type floor/ wall
mounted Main Distribution Board panel made out of 2.0 mm thick CRCA sheet
328 including connection, inter-connection alongwith 4 strip aluminium bus bar as per CPWD
specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel
mounting switchgears etc. as required.,
329 INCOMER FROM LT PANEL
1 Nos. 160Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
Dual type Digital energy meter with RS485 showing V, A, PF, KVAR, KWH etc.
current transformers of 160/5A ratio, 10 VA Class 1.0 metering.
332 One (1) Set of Phase Indication & ON/OFF/TRIP Lamp with 2A SP MCB.
333 Control MCB'S, control terminals & wiring as required.
Under/ Over voltage, Master trip relays along with current transformers of 160/5A ratio,
10 VA class-5P10 protection - 1 set
335 Suitable arrangement to receive incoming armored cables.
336 Ameter with ASS
337 Voltmeter with VSS
338 ON/OFF/TRIP Indication
339 Open/Close Push button
340 Auto/Manual selector switch
200 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP insulators.
1 nos. 160A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C)
Protection & Rom (For Solar)
2 nos. 100A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C)
Protection & Rom (For Lift)
3 nos. 63A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C) Protection
& Rom (For UPS & Fire Pump at Terrace)
9 nos. 40A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C) Protection
& Rom (For Lighting & Power DB)
348 15 Set of LED ON/OFF Indication Lamp with 2A Fuse.
349 MR MDB-01 above & as per SLD Set 1 948151 948151
Fabrication, supply, installation, testing and commissionings of cubicle type floor/ wall
mounted Main Distribution Board panel made out of 2.0 mm thick CRCA sheet
351 including connection, inter-connection alongwith 4 strip aluminium bus bar as per CPWD
specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel
mounting switchgears etc. as required.,
352 INCOMER FROM LT PANEL
1 Nos. 630Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
354 1 Nos. 630Amps, 415V FP CONTACTOR (AC-1 DUTY).
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Dual type Digital energy meter with RS485 showing V, A, PF, KVAR, KWH etc.
current transformers of 600/5A ratio, 10 VA Class 1.0 metering.
356 One (1) Set of Phase Indication & ON/OFF/TRIP Lamp with 2A SP MCB.
357 Control MCB'S, control terminals & wiring as required.
Under/ Over voltage, Master trip relays along with current transformers of 600/5A ratio,
10 VA class-5P10 protection - 1 set
359 Suitable arrangement to receive incoming armored cables.
360 Ameter with ASS
361 Voltmeter with VSS
362 ON/OFF/TRIP Indication
363 Open/Close Push button
364 Auto/Manual selector switch
365 BUS COUPLER
1 Nos. 630Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
367 1 Nos. 630Amps, 415V FP CONTACTOR (AC-1 DUTY).
368 ON/OFF Indication
369 Open/Close Push button
370 Auto/Manual selector switch
371 INCOMER FROM 200 KVA DG PANEL
372 Incomer from DG Set shall be provided with the following:
1 Nos. 320Amps FP MCCB 50kA With Microprocessor Based release for O/C, S/C &
Earth Fault Protection.
374 1 Nos. 320Amps, 415V FP CONTACTOR (AC-1 DUTY).
Dual type Digital energy meter with RS485 showing V, A, PF, KVAR, KWH etc.
current transformers of 320/5A ratio, 10 VA Class 1.0 metering.
376 Control MCB'S, control terminals & wiring as required.
Under/ Over voltage, Master trip relays along with current transformers of 320/5A ratio,
10 VA class-5P10 protection - 1 set
378 Suitable arrangement to receive incoming armored cables.
379 Ameter with ASS
380 Voltmeter with VSS
381 ON/OFF/TRIP Indication
382 Open/Close Push button
383 Auto/Manual selector switch
384 Reverse power Protection Relay.
385 INTERLOCKING.
386 DG Incomer, Bus coupler and AMF logic, interlocking with main incomer.
800 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP insulators.
2 nos. 400A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C)
Protection & Rom
3 nos. 125A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C)
Protection & Rom
3 nos. 40A FP MCCB 35kA With Thermal Magnetic Based Release (O/C,S/C) Protection
393 8 Set of LED ON/OFF Indication Lamp with 2A Fuse.
394 MR MDB_HVAC above & as per SLD Set 1 1485140 1485140
395 MCCB BOX (UPS I/O PANEL)
Fabrication, supply, installation, testing and commissionings of FP MCCB Box made
out of 1.6mm thick CRCA sheet including connection, inter-connection as per CP WD
specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel
mounting switchgears etc. as required.,
397 63 Amps FP MCCB 25KA
398 MR MCCB BOX (UPS I/O PANEL) above & as per SLD Set 1 20299 20299
Fabrication, supply, installation, testing and commissionings of cubicle type floor/ wall
mounted Main Distribution Board panel made out of 2.0 mm thick CRCA sheet
400 including connection, inter-connection alongwith 4 strip aluminium bus bar as per CPWD
specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel
mounting switchgears etc. as required.,
1 Nos. 63 Amps TP MCCB With Double Neutral 25KA With thermal magenetic release
for O/C,& S/C Protection.
403 One (1) Nos. Three Phase Dual Type Digital Energy Meter with necessary CTs.
404 Protection Istrument
One (1) Nos. (0-500V) 96 x 96 Sq.mm voltmeter with control Fuse & selector switch.
1 Set of (0-60 Amps) 96 x 96mm CT operated Ammeter with 3 way selector switch and
407 One (1) Set of Phase Indication & ON/OFF Lamp with 2A Fuse.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
200 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP insulators.
5 nos. 40A FP MCCB 16kA With Thermal Magnetic Based Release (O/C,S/C) Protection
412 5 Set of LED ON/OFF Indication Lamp with 2A Fuse.
413 MR UMDB above & as per SLD Set 1 176933 176933
414 LIFT PANEL
Fabrication, supply, installation, testing and commissionings of cubicle type floor/ wall
mounted Main Distribution Board panel made out of 2.0 mm thick CRCA sheet
415 including connection, inter-connection alongwith 4 strip aluminium bus bar as per CPWD
specifications, ( Part IV - Sub-station) and IS: 8623 comprising of followings panel
mounting switchgears etc. as required.,
1 Nos. 100 Amps FP MCCB 25KA With thermal magenetic release for O/C,& S/C
418 One (1) Nos. Three Phase Dual Type Digital Energy Meter with necessary CTs.
419 Protection Istrument
One (1) Nos. (0-500V) 96 x 96 Sq.mm voltmeter with control Fuse & selector switch.
1 Set of (0-100 Amps) 96 x 96mm CT operated Ammeter with 3 way selector switch and
422 One (1) Set of Phase Indication & ON/OFF Lamp with 2A Fuse.
200 Amps TP&N aluminum conductor bus bar (BPTM type Heat-shrinkable
busbar insulation) supported by DMC / FRP insulators.
426 3 nos. 63A FP MCCB 16kA With TM Based Release (O/C,S/C) Protection & Rom
427 2 nos. 40A DP MCCB 16kA With TM Based Release (O/C,S/C) Protection & Rom
428 MR LIFT PANEL above & as per SLD Set 1 161528 161528
429 TOTAL OF SUBHEAD :8 320033 5235851
430 SUBHEAD :9_UPS
431 NOTE: Tentative Battery Rating for 10 kVA UPS in Ah=42
Online UPS- Input supply: Three Phase, Output supply: Three Phase
Supplying, installation, Testing & Commissioning of of following capacity at full
load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0
to 95%, Online double conversion true sine wave Uninterrupted hot swappable (allow for
the replacement or addition of battery modules without shutting down the entire system)
modular Power Supply (UPS) system with N+1 modules (N denotes total number of
432 26.2 moduels requird for rated capacity). The UPS shall include a Rectifier, inverter, battery
bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600
VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA,
SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass,
suitable isolation transformer for additional protection against neutral faults etc. UPS shall
have inbuilt phase sequence correction.
The UPS systems offered are to be of the latest technology with Digital Control
Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor
(IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation).
The quality of design,manufacturing and inspection process should confirm to the
relevant International standards such as IEC/EN/VDE. The operating efficiency of the
UPS systems shall be >96% while operating on battery mode and delivering quality power
to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall
be < 5% at 50 %load. (The required LC (inductor (L) and a capacitor (C)) filters shall be
433 included in UPS cost), extreme power factor kit to be included to limit the input power
factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall
be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading
power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%,
50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity
of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1
meter distance, protections: Input Under voltage over voltage, abnormal out voltage,
battery over charging, output over current, short circuit protection,
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
battery deep discharge protection, 10KV surge. UPS must comply with low voltage
electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part
2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication
RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software
for iOT Communication as per approved by Engineering in charge. Required battery
racks and interconnecting copper conductor cables of suitable size and connectors and all
required accoseries are inclusive of the cost). This system must provide a means for
logging and alarming of all monitored points plus email notification. Forced air-cooling
with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at
least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in
compliance IEC 62040- 1,2 & 3, IS:16242 and CPWD Specification.
Display Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display :
a) Input: Voltage, current, Frequency.
b) Bypass: Voltage, Frequency.
c) Output: Voltage, frequency, Current.
d) Battery: Voltage, Capacity.
e) Load: KVA, KW, Percentage.
f)Temperature: STS, Inverter, PFC.
g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up
to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload /
Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical
Data: No. of power failures / Transfers to Bypass / Total Running time, etc.
i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load /UPS
Fault /Battery charging and discharging, overload, battery voltage and battery capacity.
j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown,
Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage,
Over Load and short circuit, Over Temperature. The UPS should have QR code which
should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc.
436 26.2.1 10KVA (Each Power module shall be < 10 KVA) Each 1 208893 208893
437 TOTAL OF SUBHEAD :9 208893 0
438 SUBHEAD :10_EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,
439 5.4 and providing masonry enclosure with cover plate having locking arrangement and Each 10 8351 83510
watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories,
and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections
etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip
earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as
required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring
washer spaced at 50mm
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as
443 5.9 required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring Meter 60 160 9600
washer spaced at 50mm
444 TOTAL OF SUBHEAD :10 338314 0
445 SUBHEAD :11_LIGHTNING PROTECTION SYSTEM
446 Air Termination Network
Supply, Installation, testing and commissioning of single spike air terminals of 16/10 mm
dia. & 2000 mm length as required and as per site conditions. The air terminal shall be
manufactured with aluminium & shall be as per IEC 62561-2. The air terminal shall be
fixed with base plate arrangement.
Supply, Installation, testing and commissioning of 8 mm dia aluminium round conductor
448 MR for air termination network at parapet terrace level and shall meet the requirement of IEC Meter 312 158 49409
Supply, Installation, testing and commissioning of Parapet Conductor holder for holding
of 8 mm dia. round conductor (for RCC roof). The conductor holder shall meet the
requirements of IEC 62561-4.It should be installed at every 1 mtr.
Supply, Installation, testing and commissioning of 16sq.mm. copper cable along with lugs,
having 500mm length & as per IEC 62561-1 so as to connect air termination rod with any
metallic structure on the roof.
Supply, Installation, testing and commissioning of Universal Connector for making
451 MR straight, Tee & Cross joint of 8-10 mm Round Conductor to 8-10 mm dia Round Nos. 57 403 22977
conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supply, Installation, testing and commissioning of Expansion piece made aluminium & as
per IEC 62561-2 along with suitable connecting accessory. It shall be installed at every 20
mtr to maintain the flexibility to the conductor due to heat.
453 Down Conductor
Supply, Installation, testing and commissioning of 10 mm dia CBS round conductor for
454 MR Down conductors (100 Microns Copper Coating) to be installed in column. It shall meet Meter 216 533 115057
the requirements of IEC 62561-2.
Supply, Installation, testing and commissioning of Rebar Clamps for holding Down
455 MR Conductor of 10 mm diameter Copper bonded steel round conductor with Rebar Nos. 144 792 114020
complying as per IEC 62561-1. It shall be installed at every 1.5 mtrs.
Supply, Installation, testing and commissioning of Earthing stud/ Façade Stud of stainless
456 MR steel with clamp to connect down conductor with parapet conductor at terrace & meet the Nos. 10 1728 17276
requirement of IEC-62561-1.
Supply, Installation, testing and commissioning of Test link to disconnect the Round
down conductor from the earth termination network 10mm copper bonded steel for
regular checks of the earth termination resistance value. (with MS Enclosure concealed in
RCC column). It shall meet the requirements of IEC 62561-2.
Supply, Installation, testing and commissioning of Straight - Connector (for Down
conductors) for making straight joint of 10 mm CBS Round Conductor to 10 mm dia CBS
Round conductor in column. (Provided at every 3.5mtr)
Supply, Installation, testing and commissioning of Lightning Strike counter Model: JMV
7D for counting the number of lightning strikes without any power supply. The Counter
459 MR should be mounted on the Down Conductor. The Lightning Counter should be IP 68 rated Nos. 1 17276 17276
enclosure suitable for external application.
460 Earth Termination Network
Supply, Installation, testing and commissioning of Earthing termination made of copper-
bonded rod of 3mtr length,14.2 mm dia. (Minimum copper bonding shall be 0.25mm) as
per IS 3043, IEEE-80, NBC 2016 along with 25 kg/pit Earth enhancement material of
461 MR resistivity less than 0.12 ohm-mtr, and complying IEC 62561-7, SS clamp for terminating Nos. 10 8638 86379
the earth rod and Eco Guard Compact pit cover complying IEC 62561-5 and as per
specification and other applicable codes.
Supply, Installation, testing and commissioning of 10 mm CBS Conductor (250 Microns
Copper Coating) laid below the ground, as Required and as per specification and code of
463 Surge Protection Device
Supply, Installation, testing and commissioning of Class B/Type I Single-Phase Surge
Protection Devices The devices shall comply with IEC 62305-4 standards and be tested as
per IEC 61643-11. They should be DIN rail mountable and enclosed in a polycarbonate
464 MR enclosure with an IP 65 rating. These SPDs are required for installation at the main Nos. 1 17276 17276
distribution board or the entry point of the electrical installation to protect against high-
energy surges caused by direct lightning strikes or high-energy disturbances.
465 TOTAL OF SUBHEAD :11 0 855611
466 SUBHEAD :12_SOLAR PV POWER GENERATION
Solar Photovoltaic Power Plant
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power
Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central
Electricity Authority Regulations and CPWD Specifications as amended up
to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering
467 17.1 facility, necessary control, protections, earthing, cabling, mounting structure, junction
boxes, power conditioning units, Real time online web interfaced Data Monitoring
System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and
other accessories etc. as required.
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above,
manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-
Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be
less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C.
PV modules used in solar power plants/ systems must be warranted for their output peak
watt capacity, which should not be less than 90% at the end of 10 years and 80% at the
468 end of 25 years. Solar Modules shall be designed to operate in relative humidity upto
100% with temperature between -10 0C and +85 0C. Further, each PV module used in
any solar power project must have Radio frequency identification tag with information
such as name of manufacturer, month and year of manufacturing, country of origin
(separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the
module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC,
three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a
variation of 10% at nominal voltage. Power with efficiency not less than 97%, total
harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C,
Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data
logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP.
PCU/inverter shall be capable of complete automatic operation including wake-up,
synchronization & shutdown. The PCU shall be able to withstand unbalanced load
conforming to IEC standard with shutdown/standby mode. It must be provided with grid
islanding along with manual disconnect pole isolation switch besides automatic
469 disconnection. Minimum protections: Mains Under / Over Voltage, Over current,
Over/Under grid frequency, Over temperature, Surge voltage induced at output due to
external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other
protections as per applicable standards. LCD/LED display of minimum parameters:
DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase),
Instantaneous & cumulative AC output power, Daily DC energy produced and other
parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed
by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as
per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level /
ground level. The mounting structure would be designed to sustain wind load and seismic
parameter of the site of installation. All the structure shall be design as per applicable BIS
code and the material shall also confirm the applicable BIS Code. Structural material shall
be corrosion resistant and electrolytically compatible with the materials used in the
module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance
and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for
various parameters such as Solar Irradiance, temperature, AC Output Voltage and current,
471 Output Power, Power factor, DC Input Voltage and Current, Time Active,
Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination
arrangement for incoming and outgoing cable along with glands, lugs and other
accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated
Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with
High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with
resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation
switches isolate the DC input to Inverter, copper bus bar etc.
473 f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE
insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked)
along with supplying & fixing of necessary channel/conduit, GI cable trays, supports,
lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal
475 cladded, having copper bus bar, having required protection and control gears, connection-
interconnection, etc. as required.
476 SOLAR PHOTOVOLTAIC as described above kWp 70 54280 3799600
477 TOTAL OF SUBHEAD :12 3799600 0
478 SUBHEAD :13_FIRE ALARM SYSTEM
479 28.2 INTELLIGENT FIRE ALARM SYSTEM
Supplying, installation, testing and commissioning of micro processor based intelligent
addressable main fire alarm panel, central processing unit with the following loop
modules and capable of supporting not less than 240 devices (including detectors) and
minimum 120 detectors per loop and loop length up to 2 km, network communication
card, minimum 320 character graphics/ LCD display with touch screen or other keypad
and minimum 4000 events history log in the non volatile memory (EPROM), power
supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have facility to connect printer to
printout log and facility to have seamless integration with analog/digital voice evacuation
system (which is part of the schedule of work under SH: PA System) and shall be
complete with all accessories . The panel shall be compatible for IBMS system with open
protocol BACnet/ Modbus over IP complete as per specifications.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/
482 28.2.3 Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete Each 1 113734 113734
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying, installation, testing & commissioning of central graphical fire alarm
management system to centrally monitor and operate the fire alarm system as required.
Supplying, installation, testing & commissioning of intelligent analog addressable
photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on
485 28.2.5 surface/recessed MS Box having two LED, metallic cover complete with all connections Each 101 306 30906
etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as
Supplying, installation, testing & commissioning of intelligent addressable thermal
487 28.2.9 detector with rate of rise cum fixed tempreature thermistor complete with base as Each 2 2866 5732
Supplying, installation, testing & commissioning of addressable manual call point
complete as required.
Supplying, installation, testing & commissioning of addressable fire control module
complete as required
Supplying, installation, testing & commissioning of addressable horn cum strobe complete
Supplying, installation, testing & commissioning fire fighter telephone handset complete
Supplying, installation, testing & commissioning fire fighter phone jack complete as
Supplying, installing, testing & commissioning of approved make Addressable Monitor
Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall
monitor potential free contacts. The device shall have an LED which shall blink in normal
state & get steady on activation to monitor the heath status of the device. Addressing shall
be with user friendly rotary decimal switches. Module shall be supplied with mounting
plate from OEM for ease of installation & maintenance.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with
494 28.5.2 annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR Meter 450 192 86400
outer sheath complete as required.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor,
single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and Fixing of following sizes of steel conduit along with accessories in surface/
497 1.20 recess including cutting the wall and making good the same in case of recessed conduit as
499 TOTAL OF SUBHEAD :13 2233768 27209
500 SUBHEAD :14_PUBLIC ADDRESS SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with
501 28.3.1 USB, MP3 player (including 6 zone button paging station) with seamless integration Each 1 132115 132115
facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall
speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V
rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with
microphone assembly complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in
505 28.5.3 the existing surface / recessed steel conduit of following pairs, cores and size including
connections and interconnections etc. as required.
506 28.5.3.1 speaker cable Single pair, 2-core, 1.5 sqmm Meter 1500 61 91500
Supplying and Fixing of following sizes of steel conduit along with accessories in surface/
507 1.20 recess including cutting the wall and making good the same in case of recessed conduit as
Supplying and Fixing 25 mm dia MS flexible pipe with PVC coating along with all
ancillaries and accessories like coupler etc. as required.
510 TOTAL OF SUBHEAD :14 972152 0
511 SUBHEAD :15_DATA & VOICE SYSTEM
512 SECTION - I- STRUCTURED CABLING SYSTEM PASSIVE
Supplying and drawing following core Fiber Optic Cable having corrugated steel
armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly,
duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and
513 39.19 Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape
(ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C
and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at
Operational Wavelength 1310 nm and ± 0.22
514 39.19.1 Single Mode 6 Core Optical fiber cable Meter 100 64 6400
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted
cable saddles for jumper management, suitable to manage both splices and terminations,
Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in,
metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered
fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter,
Removable front and rear covers for better access to interior of LIU, Should be Single /
Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear
screws, and spiral wrap tube etc complete as required.
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC
Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber
corning single mode G652D, Cable Type 2mm with Mechanical specification Apex
Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm,
Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage
Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded.
Must be of 1U height with clear label holders and white label with the panel.24 Ports Cat-
6 Patch Panel should have ETL/UL verification program certificate for compliance with
ANSI/TIA-568.2-D etc. complete as required.
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord
519 39.13 should have ETL/UL verification program certificate for compliance with ANSI/TIA-
568.2-D etc. complete as required.
520 39.13.1 Copper Patch Cords of length 1m (3ft) Each 113 173 19549
521 39.13.2 Copper Patch Cords of length 3m (10ft) Meter 113 405 45765
Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet
(IO) with face plate of color as per site requirement, should have ETL/UL verification
522 39.15 program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Each 113 302 34126
Components should be from same OEM to maintain compatibility and interoperability etc.
complete as required.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid
copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal
(solid) Cable suitable for high speed data networking application supporting upto
10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with
523 39.18 color coded insulation for easy indentification should have FLAME PROPERTIES i.e.
Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards
compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew
should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have
been tested and verified by UL/ ETL etc. complete as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover
plate for modular switches in recess etc. as required.
Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing
Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L-
Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-
down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line
cable entry/exit provision at top and bottom with rubber protection, Front door 5mm
Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or
perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS,
2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware
mounting screws packet of 20 x 1 number, etc. complete as required.
528 SECTION - II- IP-PBX SYSTEM
Supplying, installation, testing and Commissioning of IP based voice communication
system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30
Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further
additions, 100 analog users, 01 Number IP based Operator Console, 100 Party
529 38.1 Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring, Each 1 1578920 1578920
Call Pickup, Redundant server in active -Active mode and as per technical specification
including supporting accessories etc complete as required. The system should have valid
TEC GR approval from DoT.
Supplying, Installation, Testing & Commissioning of Analog phones having standard
530 38.4 feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility Each 34 1544 52496
etc. complete as required.
531 SECTION - III- LOCAL AREA NETWORK ( LAN )
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying, installation, Testing and commissioning of 10 Giga Bandwidth Data Centre
Network Switch of 48 port Layer 3 having features and specifications etc. as mentioned
here under: - ToR/EOR/Core Network Switch 48x 10GbE SFP+, 6x 100GbE QSFP28,
RPS, with Console Port, Management Port and 1 x USB 2.0 Type A port, The switch
must provide a switching capacity of no less than 2.16 Tbps and a forwarding rate of at
least 1600 Mpps, ensuring non-blocking performance for high-bandwidth applications. It
should support hot-swappable dual power supply modules (AC or DC) for 1+1
redundancy and load sharing, as well as hot-swappable, front-to-back airflow fan trays
with N+1 redundancy to ensure continuous availability. IEEE 802.1X support for port-
based and MAC-based authentication should be available, along with integration for
RADIUS and TACACS+ authentication services. Guest VLANs, DoS prevention, and
management access restrictions are essential. SNMP v1/v2c/v3, syslog, sFlow, and
support for autoconfiguration via DHCP. Support for OpenFlow v1.4, Netconf/YANG,
and LLDP is required for modern network automation. Support ONIE (Open Network
Install Environment), IEEE 802.1Q bb Priority-based Flow Control (PFC), OpenFlow
v1.4, ERPS, IPv6 Tunneling, IP interfaces and supported, VXLAN, Private VLAN,
Multicast VLAN, Guest VLAN Double VLAN (Q-in-Q), RoCEv2, PIM-SSM/SM,
MSDP. Support High Availability with MLAG/VSS and Layer 2/3 VPNs Critical for
Multi-tenant, Virtualized, and Containerized Environments. BGPv4/v6, OSPFv2/v3,
IS-IS, RIPng. VRRP, ECMP, BFD, and route redistribution for high-availability routing.
Support flexible routing domains and secure inter-segment traffic flow. Certifications:
FCC, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of
Telecommunication, Government of India etc. complete as required.
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2
indoor Network Switch having features and specifications etc. as mentioned here under:
At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP
Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and
packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port,
Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP,
RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP
Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more,
IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper,
ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN,
VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+
Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED,
802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP
Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP,
LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route,
SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access
ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted
Telecom Portal of Department of Telecommunication, Government of
India etc. complete as required.
24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each
copper port supporting 802.3at PoE+ min.
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for
535 39.6 Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.
536 39.6.1 1G SFP Single Mode/Multi Mode Nos. 2 4211 8422
537 39.6.3 10 G SFP + Single Mode/Multi Mode Nos. 2 14972 29944
Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for
High density use having features and specifications etc. as mentioned here under- WiFi6
802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console
port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise,
WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS
server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point,
WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL),
Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security –
WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and
MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone,
Compatible with S/W & H/W Controller with addtional features like - Real-Time
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for
Low Density use having features and specifications etc. as mentioned here under - Dual-
band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x
RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3™
Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access
control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel,
Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure
Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports
539 39.7 enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Nos. 1 22739 22739
Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC.
Should also work as Standalone and must be Compatible with S/W & H/W Controller
with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features,
Centralized Device Management, Role-Based Administration, Real-Time Monitoring,
VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-
SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom
Portal of Department of Telecommunication, Government of India etc. complete as
Supplying and Fixing of following sizes of steel conduit along with accessories in surface/
540 1.20 recess including cutting the wall and making good the same in case of recessed conduit as
542 TOTAL OF SUBHEAD :15 5994320 0
543 SUBHEAD :16_CCTV SYSTEM
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3
Network Switch having features and specifications etc. as mentioned here under: At least
20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports
with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of
min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC
table. Console Port, USB port, Internal AC Power supply with operating temperature of 0
to +50 0C. Stacking port with stacking support of minimum 8 units per stack. 48K Mac
address, 9K or more Jumbo frame, ERPS with enabling ring to converge in less than 50
ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, IPv6
Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route
Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1
for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C
accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access
List, MAC Access List. Multicast: VLAN, PIM-SM, PIMDM, PIM- SDM, PIM-SMv6,
DVMRP v3 and MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD
Snooping Ǫuerier, Per-VLAN IGMP C MLD Snooping. SNMP, Dual configurations,
Multiple images, RMON, LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client, IPv4/IPv6,
Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity
Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control
(PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet
ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE,
OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication,
Government of India etc. complete as required.
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded.
Must be of 1U height with clear label holders and white label with the panel.24 Ports Cat-
6 Patch Panel should have ETL/UL verification program certificate for compliance with
ANSI/TIA-568.2-D etc. complete as required.
Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should
546 39.12 have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D
etc. complete as required.
547 39.12.1 Copper Patch Cords of length 1m (3ft) Each 41 151 6191
548 39.12.2 Copper Patch Cords of length 3m (10ft) Each 41 227 9307
Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet
(IO) with face plate of color as per site requirement, should have ETL/UL verification
549 39.14 program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Each 41 212 8692
Components should be from same OEM to maintain compatibility and interoperability etc.
complete as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover
plate for modular switches in recess etc. as required.
552 40.5 5/6MP IP IR Dome Camera
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having
following specifications and features etc :-
1)Type of Camera: Dome Camera
2) Image Sensor: 1/2.8" or better progressive Scan
CMOS get color image even at night condition
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0
lux with IR or better
5) Imaging: 1/3s to 1/30000s Shutter Support, Auto
Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC,
553 Digital Watermarking.
6) On Screen Display: Camera should display Camera
title, Date & Time in live & recorded video both.
7) Signal to Noise Ratio: > 50 dB
8) Day & Night: True Day & Night High Performance
Mechanical IR cut filter with auto switch, IR Source-
Inbuilt IR LED's with effective distance upto 50 Mtrs
integrated IR 30 Mtrs for colour view in night.
9) Video Compression (Minimum): H.265 or better,
Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
10) Wide Dynamic Range: WDR (120dB or more)
11) Digital Noise Reduction: DNR (2D/3D) On/Off
12) Streaming: Triple streaming, configurable
13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP
@25/30 fps, Sub streams: D1@25/30 fps or better
14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable
through client software or web browser
15) Profile Management: User configuration import, export
16) Security: User Authentication, Water Marking
17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot
upto 512 GB. It should be supplied with minimum 128GB memory Card.
18) Recording Management: Format SD, overwrite, storage management, video to NAS
19) Edge Analytics : Tripwire, Intrusion, Motion Detection
20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
21) Alarm Support: It should have 1/1 Alarm In/ Out Port
22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external
Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/
AAC/ G.726 audio compression
23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP
TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
24) System Capability: ONVIF
25) VMS: Camera shall support open source VMS
26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption,
trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC
filtering, HTTPS, trusted upgrade.
27) Ethernet: 1 RJ 45 10/100 Ethernet port
28) Power Input: The camera should support simultaneous dual power input—12 VDC
(via power adapter) and PoE—to ensure continuous operation in the event of a failure in
one power source.
29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE
30) Enclosure: IP67 weather proof, IK10
31) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max)
(non-condensing)
32) IR life: 40000 hours or higher
33) Video Bit rate: 32 KBPS - 8 MBPS or better
34) Standards: BIS with ER, STQC Certified, CE, FCC
5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens Dome
557 40.6 5MP /6MP IP IR Bullet Camera
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera
having following specifications, type of lens and features etc :-
1) Type of Camera: Bullet Camera2) Image Sensor: 1/2.8" or better progressive Scan
CMOS get color image even at night condition
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0
lux with IR or better
5) Imaging: 1/3s to 1/30000s Shutter Support, Auto
Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC,
Digital Watermarking.
6) On Screen Display: Camera should display Camera
title, Date & Time in live & recorded video both.
7) Signal to Noise Ratio: > 50 dB
8) Day & Night: True Day & Night High Performance
Mechanical IR cut filter with auto switch, IR Source-
Inbuilt IR LED's with effective distance upto 50 Mtrs
integrated IR 30 Mtrs for colour view in night.
9) Video Compression (Minimum): H.265 or better,
Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
10) Wide Dynamic Range: WDR (120dB or more)
11) Digital Noise Reduction: DNR (2D/3D) On/Off
12) Streaming: Triple streaming, configurable
13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP
@25/30 fps, Sub streams: D1@25/30 fps or better
14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable
through client software or web browser
15) Profile Management: User configuration import, export
16) Security: User Authentication, Water Marking
17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot
upto 512 GB. It should be supplied with minimum 128GB memory Card.
18) Recording Management: Format SD, overwrite, storage management, video to NAS
19) Edge Analytics : Tripwire, Intrusion, Motion Detection
20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
21) Alarm Support: It should have 1/1 Alarm In/ Out Port
22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external
Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/
AAC/ G.726 audio compression
23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP
TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
24) System Capability: ONVIF
25) VMS: Camera shall support open source VMS
26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption,
trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC
filtering, HTTPS, trusted upgrade.
27) Ethernet: 1 RJ 45 10/100 Ethernet port
28) Power Input: The camera should support simultaneous dual power input—12 VDC
(via power adapter) and PoE—to ensure continuous operation in the event of a failure in
one power source.
29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE
30) Enclosure: IP67 weather proof, IK10
31) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max)
(non-condensing)
32) IR life: 40000 hours or higher
33) Video Bit rate: 32 KBPS - 8 MBPS or better
34) Standards: BIS with ER, STQC Certified, CE, FCC
5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying Installation Testing and Commissioning of following Channel Network Video
Recorder (NVR) with camera licenses to record for all channels having specifications
and features etc as mentioned below :
1) Network Video Recorder Embedded/ Installed OS
(Linux) along with Camera Licenses to record per NVR and to provide a live view,
storage and simultaneously Multi-channel playback of all IP camera or more and must be
ONVIF with minimum support of 384 Mbps incoming Bandwidth.
2) NVR should support video compressions : H.265 or better, H.264, MJPEG.
3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with
G.711U/A, G.711u, PCM, G726 audio compressions.
4) Intelligent auto power on when power resumes after power outage.
5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID
562 40.11 support of RAID 0/1/5/6/10.
6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x
RS232, 1x eSATA Port
7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
8) Video Output Ports: 2x HDMI and 2 VGA
9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external
sensors and output devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated
mobile number for power failure, HDD failure, vandalism, tempring, network
disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for
alerts and viewing.
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP
Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration,
ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote
monitoring without any public IP need.
13) Standards: CE, FCC, RoHS, BIS Certified
14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.
15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)
16) The VMS application shall support all the features & functionalities of the offered
17) VMS should consist Licenses for all channels to record Cameras with General,
motion detection, intelligent, alarm and POS recording modes. VMS should be provided
with Camera Licenses , with no dependency of VMS licenses by binding with the MAC
563 address of the cameras to achieve the functionality.
18) The NVR OEM shall be responsible for providing a mobile application compatible
with both Android and iOS devices, enabling remote monitoring and playback of
cameras/NVR footage.
19) The OEM must provide its own DDNS server hosted in India, eliminating the need
for a public IP address for remote monitoring over the Internet.
20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode
21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p;
720p; D1; CIF; QCIF
22) When alarm recording is enabled and an event occurs, you can click the alarm icon on
monitoring page to view the alert details. The snapshot function is supported on
monitoring and playback page
23) The Network Video Recorder (NVR) shall be configured to send email whenever a
system message is created or an alarm event occurs. The email server shall be a valid
SMTP server. Each recipient email address shall be configured to receive any
combination of critical, warning, or informational messages or alarm notifications. When
an alarm occurs, the email message includes the NVR name, time of alarm and a list of
camera that is configured to record upon alarm
24) It should have Web and GUI interface.
25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face
detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8
Channel Smart Motion Detection
564 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist
capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face
images/sec and facility to add Name, gender, birthday, address, credential type, credential
No., countries & regions and state to each face image.
27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group,
glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and
28) ANPR Capability: It should support ANPR Camera with License plate, plate color,
vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location
etc vehicle attributes.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene
changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter
protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd
distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan,
cybersecurity exception
30) Alarm Notification should be linked with Recording, snapshots, Camera external
alarm output, buzzer, logs, presets and email.
565 31) General AI Based Search: Search Pictures by channel, time, event type, target
classification (Fall Detection, People Approach Detection, People No. Exception
Detection, People Staying Detection, Violence Detection.
32) Smart playback function: Should support smart search for the selected area in the
video and smart playback to improve the playback efficiency
33) VCA (Video Content Analytic): Should support multiple video contented analytics
based on camera analytics
34) Analytics by NVR: Perimeter protection and face recognation
64 Channel Network Video Recorder (NVR) having display split :- Main screen:
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade
Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5
567 40.12 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC,
Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH
23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded
Twisted Pair, 4 pair should be complied as per UL/ETL verification program for
compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of
6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :
< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as
Supplying and Fixing of following sizes of steel conduit along with accessories in surface/
571 1.20 recess including cutting the wall and making good the same in case of recessed conduit as
Supply, Installation, Testing and Commissioning of Full HD 55" LED Professional
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM)
i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3
1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline
574 MR DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) Each 1 107974 107974
82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5"
SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest.
575 TOTAL OF SUBHEAD :16 2310549 181827
576 SUBHEAD :17_ACCESS CONTROL SYSTEM
Access Control System with 1.77" display (without Face Recognition Readers)
Supplying, Installation, Testing and Commissioning of Access Control System comprising
of Fingerprint & Card based Reader with 1.77" LCD Display, Fake Fingerprint Detection
Technology, supports ANSI 378 encryption, AES 128 bit encrypted algorithm to protect
important info such as personal info transmitted, 5,000 Fingerprint storage (1 :N) / 10,000
Fingerprint storage (1 :1), 50,000 transaction logs, Onboard Camera to
577 41.4 capture live images against transactions, Communication protocols like TCP/IP, Wiegand Nos. 3 28073 84219
Out / IN, RS 485, OSDP; Supports Mobile Key through Bluetooth, User wise
authentication modes; Built in Lock Control; UL Listed Power Supply, Certification: CE,
FCC, RoHS, BIS, WPC, Ingress Protection IP 65 etc. suitable for mounting on metal
surface/metal frames/ wooden frames / wall / flap barriers including all mounting bracket
& accessories complete etc. as required.
Software for Web based Access Control System
Supplying, Installation, Testing and Commissioning of Web based Access Control
Enrolment and Device Configuration Software, Should be independent of OS (Windows),
Unified Management of Biometric, Card, and Controllers, Import Functionality for bulk
user details, Biometric Template Retrieval for Data Recovery, User Management, Logs
and Terminal Management, Support for IP-based and USB Biometric Devices, User-
specific Access Policies, Different User Policies on the Same Terminal, Assignment of
Specific Access Schedules, Pushing Users to Terminals or Groups, Admin Authority
Management to define rights of each user to perform, Blacklist User Management, Access
Schedule Creation, Real-Time Log Retrieval, Real- Time User Identification, Secure
Storage of Biometric/Users Data, Capable to integrate with 3rd party applications over
Web API's, MQTT protocol support
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Electromagnetic locks
Supplying, Installation, Testing and Commissioning of Electromagnetic locks (fail safe
type) for following type of Doors suitable for operation on 12 V DC having holding force
600 lbs for Single Leaf Door and 1200lbs for Double leaf door with suitable feedback i/c
connection complete etc. as required.
580 41.6.1 Single leaf door Nos. 2 4831 9662
581 41.6.2 Double leaf door (Each leaf 600lbs & Total 1200 lbs) Nos. 1 7593 7593
Exit Push Button
Supplying, Installation, Testing and Commissioning of Heavy Duty SS Finish Exit Push
Button for releasing access doors with all necessary installation accessories i/c connection
complete etc. as required.
Supplying, Installation Insta, Testing and Commissioning of Door Position Sensor i/e
connection complete etc. as required.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH
23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded
Twisted Pair, 4 pair should be complied as per UL/ETL verification program for
compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of
6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :
< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as
Supplying and Fixing of following sizes of steel conduit along with accessories in surface/
586 1.20 recess including cutting the wall and making good the same in case of recessed conduit as
Supply ,Installation ,Testing & Commissioning of Smart Card Contactless transmission of
588 MR data and supply energy (No battery needed), Operating Distance: Upto 100mm Nos. 5 276 1382
(Depending on Antenna Geometry), Operating Frequency: 13.56 MHZ.
Supply and Laying of 8 Core x 1.0 sq mm multi strand, copper, unarmoured shielded
Cable as per specification (between the every card readers & the access controllers)
Supply and Laying of 4 Core x 1.0 sq mm multi strand, copper, unarmoured shielded
Cable as per specification (between the every card readers & the access controllers)
591 TOTAL OF SUBHEAD :17 256451 49452
592 SUBHEAD :18_SECURITY SYSTEM
Supply, installation, testing and commissioning of automatic electromechanical boom
barrier suitable road width 5-7 mtrs for intensive applications, high speed with 4-6
second opening/closing time with Aluminium housing & aluminium boom with fork rest,
IP 67 Protection etc. (for Gate Entry/Exit).
Supply , Installation , Testing and Commissioning of a set of Entry/Exit push buttons for
594 MR manual open and closing of barriers etc. complete as required.(for Gate Entry/Exit). Nos. 2 3887 7774
Supply , Installation , Testing and Commissioning of Photocell based safety device to
595 MR avoid closing of the barrier when a Vehicle is crossing the barrier. (Anti Fall Protection ). Nos. 2 5615 11229
596 MR Supply installation, testing and commissioning of Remote & Receiver. Nos. 2 3455 6910
Supply , Installation , Testing and Commissioning of Loop detector for closing of the
barrier when a Vehicle crosses the barrier.
599 SUBHEAD :19_DIESEL GENERATOR SET
Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as
per CPCB IV + or better norms along with having Prime Power Rating of KVA as below,
415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase
system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test
and other necessary arrangements Complete as per CPWD specifications, should have QR
code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing
location, rating plate as per relevant IS Code etc. and consisting of the followings:
601 (A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced
fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of
alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over
loading for one hour after 12 hours of continuous operation. The engine will be with
Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel
(after commissioning) lubricating Oil, Coolant and other consumables complete with all
the required accessories, the Electronic governor shall be as per ISO 8528.The engine
shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS
5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital display for
604 (i) Start-stop switch with key
605 (ii) Water temperature indication
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
606 (iii) Lubrication oil pressure indication
607 (iv) Lubrication oil temperature indication
608 (v) Battery charging indication and Voltage indication
609 (vi) RPM indication
610 (vii) Over speed indication
611 (viii) Low lubricantion Oil trip indication
612 (ix) Engine Running Hours indication
613 (x) Fuel Level
614 (C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz,
AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL.
The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23,
615 brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over
loading for one hour after 12 hours of continuous operation, self cooled,self-excited and
self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for
tropical conditions and with class- H insulation.
616 (D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS
channel with necessary reinforcement which shall be installed on suitable cement
concrete foundation and vibration isolation arrangement as per recommendations of
618 (E) FUEL TANK:
Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated
out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping
619 between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with
valves, level indications & accessories as required as per specifications.
620 (F) Exhaust System:
621 Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
622 (G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and
arrangement for initial excitation complete with suitable numbers of batteries (180 AH
capacity lead acid SMF type) as required as per specifications. The battery shall be
housed inside the acoustic enclosure of DG Set.
624 (H) Acoustic and weather proof enclosure
with arrangement for fresh air intake for cooling of the engine & alternator, extraction,
discharging hot air in to the atmosphere and the temperature rise inside the enclosure,
noise level outside enclosure. The acoustic enclosure should be suitable for cable
connection/connection through bus-trunking. Such arrangements on acoustic enclosure
should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall
be as per CPCB IV + or better norms etc. and as per CPWD specifications.
626 (I) AMF Panel:
Free standing floor mounted IP 42 automatic mains failure control panel including auto by-
pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of
CTs for metering & protection and energy analyser to indicate currents, phase and line
voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH),
KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault,
627 under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15
meter between AMF panel, LT Panel and DG Set including connection interconnection
etc. as required, all complete and inter locking and communication/ Ethernet
/RS485/SNMP port open protocol for BMS integration including suitable software, the
panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and
including the following:
1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw
628 out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and
629 2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos.
reverse power relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA
class-I for metering
5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA
(Phase & Total), Frequency, KWH, PF
633 6. LED Indicating lamps for load on mains and load on set.
634 7. Fuse/ MCB for instruments.
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter,
635 selector switch for trickle, off and boost and current
636 9. Main supply failure monitor.
637 10. Supply failure timer.
638 11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure
to start lockout.
640 13. Impulse counter with locking and reset facility.
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
641 14. ON/OFF/Control circuit switch with indicator
642 15. Audio/Video annunciation for
643 (i) High water temperature
644 (ii) Low lubricating oil pressure
645 (iii) Engine over speed
646 (iv) Engine fails to start
647 (v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing
648 load with suitable number of relays and
649 17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of incomer
breakers, bus coupler switching of essential panel , interlocking providing signal to AMF
Panel for load status and AMF shall give command to DG Set to auto start / auto stop
depending upon load status and requirement etc. and necessary hardware and software
required to perform the operation shall be provided by the contractor including all control
653 TOTAL OF SUBHEAD :19 2433003 0
654 SUBHEAD :20_LIFT
1: Contactor will submit the GA Drawings of Lift for Approvel from
Clint/Consultant before order the Lift.
2: Lift pit depth & overhead etc. will be as per NBC norms.
Supplying, Installation, Testing & Commissioning of following capacity passenger
Machine room less (MRL) lift with regenerative drive as per CPWD General
Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016
as amended upto date having provision for barrier free access as per Harmonised
Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving
different floors in the lift shaft as per detailed specifications enclosed and as under
other equipment and accessories complete as required:-
(i) Speed-1 MPS
(ii) Floors-3 (G+2)
(iii) Travel -8 Meters (approx.)
(iv) Stops & opening- 3 stops and 3 openings
(v) Controller: A.C. variable voltage & variable frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as
vii) Operation: Microprocessor based single automatic push button/simplex selective
collective/duplex collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline
Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
(xi) Type of doors
(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof
(Moon Rock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent
to control panel in the lift car.
(xiii)Voice announcement system in the car to announce the position of the elevator in the
hoist way as the car passes or stops at floor served by the
(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic
control, Landing doors 2 hours Fire rated, Overload detection and
protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings,
BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the
lift car door, Alarm horn, Anti Nuisance
Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30
days storage backup , Firemen switch, 2/3 way intercom,
Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to
signal for help or assistance in the event of an emergency.
(xvi) An appropriate technological support be provided (Through
emergency messaging |services or alarms etc.) to respond to the emergency requirements
of person with hearing impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
659 TOTAL OF SUBHEAD :20 3368451 0
660 SUBHEAD :21_EXTERNAL LIGHTING
661 Feeder Pillar
Design, manufacturer, supply, testing and commissioning of approx size 1200 mm
heightx1000mm wide x 450mm deep of 2.5mm thick sheet metal enclosure, powder
coated, weather proof, double door type feeder pillar with godown lock and padlock
complete with interconnection with copper wires, LED indicating lights, providing holes
for the glands. The base frame shall have angle iron of 50mm x 50mm x6mm of size
1000mm x 450mm with 600mm long legs of MS angle and coverage of underground
cable under feeder pillar with 2.5 mm thick sheet, 450mm in width all round the base
frame including grouting the feeder pillar in 1:4:8 cement concrete complete as required.
Feeder Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with
earth bus and lifting hooks as required. Approval shall be taken for each panel before
fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc
663 Feeder Pillar
1 No. 40 amps FP MCCB(25 KA) with thermal Magnetic release (PRMB-3) with Class-
665 C transient voltage surge suppression device suitable for 3 phases as per specifications.
666 Protection Istrument
One (1) Nos. (0-500V) 96 x 96 Sq.mm voltmeter with control Fuse & selector switch.
1 Set of (0-40 Amps) 96 x 96mm CT operated Ammeter with 3 way selector switch and
669 One (1) Set of Phase Indication & ON/OFF Lamp with 2A Fuse.
1 Nos.TIMER suitable for 24Hrs. Setting with Auto/Manual Selector switch with Suitable
1 Set of 200 A TPN Aluminium Bus Bar with colour coded PVC Sleeves (Heat
Shrinkable sleeve)
674 4 No. 32 A 2P MCCB, 16 KA
675 MR Feeder pillar as described above Set 1 140941 140941
Supplying and fixing of Family of Decorative Casting poles in different designs, shaped
and heights to compliment the EROS LEDPost Top family. These poles can infuse life
677 MR into roads of high importance and visibilty.complete with all fixing accessories as Each 16 43984 703745
required of Cate. Ref. HAVELLS : EROSPOLET03060M or apporoved equivalent.
Supplying and fixing of Family of Decorative Arms in different designs, shaped and
lengths to compliment the EROS LED Post Tops and Poles Family.complete with all
fixing accessories as required of Cate. Ref. HAVELLS : Orbit S Round Arm for Pole or
apporoved equivalent.
Supplying and fixing of Family of Decorative Arms in different designs, shaped and
lengths to compliment the EROS LED Post Tops and Poles Family.complete with all
fixing accessories as required of Cate. Ref. HAVELLS : Orbit D Round Arm for Pole or
apporoved equivalent.
Supplying and fixing of Aesthetically designed IP 66 LED post Top with aluminium
enclosure, powered with high power LEDs as light source and die casted heat sink
exhibiting classic Victorian look with symmetrical light distribution, suspended mounting
arrangement and excellent heat dissipation for long life.complete with all fixing
accessories as required of Cate. Ref. HAVELLS :
EROSNXTPT90WLED757PSYMTOPC or apporoved equivalent.
The cable quantities given are approximate and to cover various sizes. The contractor
683 shall measure the cables required and procurement order shall be placed accordingly. The
quantities shall be confirmed before start of work.
Supply of 2 core, 6 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured
electric cable with aluminium conductor.
685 Cable termination :
Single Compression glands to be used for internal area, while double compression cable
glands to be used for outdoor installation.
Supplying and making end termination with brass compression gland and aluminium lugs
687 11.1 for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor
cable of 1.1 KV grade as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of
1.1 KV grade of following size in the existing RCC/ HUME/ metal pipe as required.
691 HDPE Pipe:
Digitally signed by SUPARNA
S. ITEM UNIT AMOUNT (IN RS.)
DESCRIPTION UNIT QTY
NO. NO. RATE DSR 2025 MR
Supplying and laying of following size DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with
fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand cushioning and protective covering
etc., complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,
695 5.4 and providing masonry enclosure with cover plate having locking arrangement and Each 2 8351 16702
watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and
696 5.2 providing masonry enclosure with cover plate having locking arrangement and watering Set 6 7658 45948
pipe etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth
697 5.11 electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling Meter 20 755 15100
etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as
699 TOTAL OF SUBHEAD :21 232158 1858313
700 SUBHEAD :22_MISCELLANEOUS ITEMS
Providing and fixing MV. danger notice plate of 200 mm X 200 mm, made of mild steel,
701 2.21 at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in Each 3 315 945
single red colour on front side as required
Supplying and laying of following size DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with
702 15.16 fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including
excavation and refilling the trench but excluding sand cushioning and protective covering
etc., complete as required
703 15.16.5 200 mm dia (OD-200 mm & ID-175 mm nominal) Metre 150 733 109950
704 TOTAL OF SUBHEAD :22 110895 0
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC
Name of Work : Plumbing Works
S. No. Description PLUMBING
DSR NSR Total
a Sanitary Installations Works 760,003.65 90,167.60 850,171.25
b Soil, Waste, Vent & Rain Water Pipes 1,440,636.70 64,836.28 1,505,472.98
c Internal Water Supply 869,786.60 22,716.00 892,502.60
d External Sewerage System 1,102,492.20 - 1,102,492.20
4.00 External Water Supply 90958.55 0.00 90,958.55
5.00 External Storm Water Drainage 617163.50 0.00 617,163.50
6.00 Rain Water Harvesting 444964.65 0.00 444,964.65
Total of External 59.82
Grand Total 5,981,571.57 Lakh
Grand Total 5,981,571.57 Lakh
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
A Sanitary Installations & Internal Water Supply
1 ,17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as
per IS 13983 with C.I. brackets and stainless steel plug 40 mm
including painting of fittings and brackets, cutting and making
good the walls wherever required :
a 17.10.1.3 Kitchen sink with drain board 510x1040 mm bowl depth 200 mm
2 17.31 Providing and fixing mirror of superior glass (of approved quality)
complete with 6 mm thick hard board ground fixed to wooden Each 35.00 1607.95 56278.25 0.00
cleats with C.P. brass screws and washers complete.
3 17.28 Providing and fixing P.V.C. Waste pipe for sink or wash basin
including P.V.C. waste fittings complete.
a 17.28.1 Semi rigid pipe
4 DSR-17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved
quality & make and as per the direction of Engineer-in-charge. Each 35.00 1034.80 36218.00 0.00
5 DSR-17.34 Providing and fixing toilet paper holder :
17.20 Providing and fixing white vitreous china pedestal type water
closet (European type W.C. pan) with seat and lid, 10 litre low
level white P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever), conforming to IS :
7231, with all fittings and fixtures complete, including cutting and
making good the walls and
floors wherever required :
6 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid Each 35.00 6515.55 228044.25 0.00
6a 17.1 Providing and fixing water closet squatting pan (Indian type W.C.
pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level
white P.V.C. flushing cistern, including flush pipe, with manually
controlled device (handle lever) conforming to IS : 7231, with all
fittings and fixtures complete, including cutting and making good
the walls and floors wherever required
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440
mm with integral type foot rests
7.00 ,18.49 Providing and fixing C.P. brass bib cock of approved quality
conforming to IS:8931 :
8.00 ,18.53 Providing and fixing C.P. brass angle valve for basin mixer and
geyser points of approved quality conforming to IS:8931
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
9.00 17.70 Providing and fixing wash basin with C.I. brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:
17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of
15 mm C.P. brass pillar taps]
10.00 18.21 Providing and fixing uplasticised PVC connection pipe with brass
18.21.2 45 cm length
11.00 18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm
12.00 17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of
quality & make as approved by Engineer in charge.
13.00 NS-1 Providing and fixing C.P. cast brass twin coat hooks fixed to PVC
rawl plug with SS screws Make Euronics, Cat. No. EC02 or Each 35.00 974.40 0.00 34,104.00
approved equivalent.
14.00 17.16.A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube
upto 1 metre long with S.S. triangular plate to Eureopean type Each 35.00 349.15 12220.25 -
W.C. of quality and make as approved by Engineer - in-charge
15.00 NS-2 Providing, fixing, testing and commissioning of CP brass swan
neck wall mounted sink mixer with wall flange and swinging
casted spout complete as required and making good the walls Each 5.00 4782.10 0.00 23,910.50
wherever required. [Make :Euronics, Model:FLO-3012A].
16.00 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm
long, 200 mm wide with minimum distances of 37 mm from wall
face with concealed fittings arrangement of approved quality and Each 35.00 231.95 8118.25 -
colour,weighing not less than 88 gms.
17.00 18.65 Providing and fixing PTMT soap Dish Holder having length of
138mm,breadth 102mm, height of 75mm with concealed fitting Each 35.00 111.45 3900.75 -
arrangements,weighing not less than 106 gms.
19.00 17.5 Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in C.P. brass) with waste
fitting as per IS : 2556, C.I. trap with outlet grating and other
couplings in C.P. brass, including painting of fittings and cutting
and making good the walls and floors wherever required :
17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing
17.73 Providingand fixingPTMT towel rail completewithbrackets fixed
to wooden cleats with CP brass screws with concealed fittings
arrangement of approved quality and colour.
20.00 17.73.2 600 mm long towel rail with total length of 645 mm, width 78
mm and effective height of 88 mm, weighing not less than 190 Each 3.00 708.95 2126.85 0.00
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
21.00 NS-3 Supply, installation, testing and commissioning of horizontal type
storage hot water heater within-built pressure relief valve, rated
for inlet water pressure upto 6 bar complet in all respects
including inlet, oulet connections, fixing bolts etc. and testing
Total C/F to Summary 760,003.65 90,167.60
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
B Soil, Waste, Vent & Rain Water Pipes
21.00 12.22 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet
1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 Each 18.00 298.25 5368.50 0.00
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.
22.00 Providing and fixing to the inlet mouth of rain water pipe cast
DSR-12.44 iron grating 15 cm diameter and weighing not less than 440 Each 18.00 54.70 984.60 0.00
23.00 17.35 Providing and fixing soil, waste, vent and rain water pipes
Hubless centrifugally cast iron pipes epoxy coated inside &
outside IS : 15905
24.00 Providing and fixing MS holder bat clamps of approved design to
cast iron (spun) pipe embedded in and Including cement concrete
17.37 blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) including cost of
cutting holes and making good the walls etc.
25.00 Providing and fixing bend of required degree with access door,
17.38 insertion rubber washer 3mm thick, bolts and nuts complete.
Hubless centrifugally cast iron epoxy coated inside & outside IS :
26.00 17.39 Providing and fixing plain bend of required degree.
Hubless centrifugally cast iron epoxy coated inside & outside IS :
27.00 Providing and fixing double equal plain junction of required
Hubless centrifugally cast iron pipes epoxy coated inside &
outside IS : 15905
28.00 Providing and fixing single equal plain junction of required degree
Hubless centrifugally cast iron epoxy coated inside & outside IS :
29.00 Providing and fixing single unequal plain junction of required
Hubless centrifugally cast iron epoxy coated inside & outside IS :
30.00 Providing and fixing Hubless cast iron offsets epoxy coated inside
& outside as per IS : 15905
17.54A.1 130 mm offsets
31.00 17.56 Providing and fixing terminal guard:
Hubless centrifugally cast iron epoxy coated inside & outside IS :
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
32.00 Providing and fixing shielded coupling for Hubless centrifugally
17.57A.1.1 SS 304 grade coupling with EPDM rubber gasket Each 700.00 432.05 302,435.00
33.00 Painting with synthetic enamel paint of approved drand and
manufacture to give an even shade
13.61.1 Two more coast on new work sqm 498.00 155.90 77638.20
34.00 4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work up
to plinth level:
4.1.3 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm
and down gauge).
35.00 ,17.60 Providing and fixing trap of self cleansing design with screwed
down or hinged with or without vent arm complete, including
cost of cutting and making good the walls and floors.
a 17.60.1 100 mm inlet and 100 mm outlet
17.60.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside &
outside as per IS:15905
b 17.60.2 100 mm inlet and 75 mm outlet
17.60.2.3 Hubless centrifugally cast (spun) iron epoxy coated inside &
outside as per IS:15905
36.00 NS-4 Providing and fixing SS grating of approved quality and colour.
Circular type 125 mm nominal dia [Make :Euronics, Model:
37.00 Fire DSR 18.8 Providing, laying, testing & commissioning of 'B' class heavy duty
G.I. pipe conforming to IS 1239 including welding, fittings like
elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing
the pipe on the wall/ceiling with suitable clamp/support frame
and painting with two or more coats of synthetic enamel paint of
required shade complete as required :
For WB, Urinal FT & FD and Sink Drain pipe
18.8.3 40 mm dia nominal bore Metre 103.00 831.00 85593.00 0.00
18.8.4 50 mm dia nominal bore Metre 80.00 927.00 74160.00 0.00
38.00 12.41 Providing & fixing on wall face unplasticised -Rigid PVC rain water
pipes conforming to IS:13592 Tyape A included jointing with seal
ring conforning to IS:5382 leaving 10 mm gap for thermal
expansion. (i)Single socketed pipes.
39.00 12.42 Providing, fixing on wall face unplasticised - PVC moulded fittings
/accessories for unplasticised - Rigid PVC rain water pipes
conforming to IS ; 13592 Type A including jointing with seal ring
conforming to IS ; 5382 leaving 10 mm gap for thermal
39.00 NS 5 Providing and fixing of 110x75 mm dia uPVC Balcony Drain Each 10.00 198.00 0.00 1,980.00
Total C/F to Summary 1,440,636.70 64,836.28
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
C Internal Water Supply
41.00 18.70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.
Internal Work - Exposed on Wall
a 18.7.3 25 mm nominal outer dia .Pipes. Metre 30.00 401.55 12046.50 0.00
a 18.7.4 32 mm nominal outer dia .Pipes. Metre 195.00 518.75 101156.25 0.00
b 18.7.5 40 mm nominal outer dia .Pipes. Metre 150.00 702.95 105442.50 0.00
18.7.6 50 mm nominal outer dia .Pipes. Metre 95.00 934.15 88744.25 0.00
42.00 ,18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all
CPVC plain & brass threaded fittings i/c fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and the cost of cutting
chases and making good the same including testing of joints
complete as per direction of Engineer in Charge.
Concealed work including cutting chases and making good the
a 18.8.2 20 mm nominal outer dia .Pipes. Metre 520.00 537.60 279552.00 0.00
b 18.8.3 25 mm nominal outer dia .Pipes. Metre 175.00 627.25 109768.75 0.00
43.00 ,18.10 Providing and fixing G.I. pipes with two coats of anti-corrosive
bitumastic paint of approved quality : complete with G.I. fittings
and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on Wall
a 18.10.1 & 15 mm dia nominal bore
b 18.10.2 & 20 mm dia nominal bore
44.00 Fire DSR - 18.8 Providing, laying, testing & commissioning of 'B' class heavy duty
G.I. pipe conforming to IS 1239 including welding, fittings like
elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing
the pipe on the wall/ceiling with suitable clamp/support frame
and painting with two or more coats of synthetic enamel paint of
required shade complete as required :
c DSR Fire-18.8.1 25 mm dia nominal bore
d DSR Fire-18.8.2 32 mm dia nominal bore
e DSR Fire-18.8.3 40 mm dia nominal bore
f DSR Fire-18.8.4 50 mm dia nominal bore
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
45.00 DSR-18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick
work in cement mortar 1:4 (1 cement :4 coarse sand) for stop
cock, with C. I. surface box 100x100 x75 mm (inside) with hinged
cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c
necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size ) and
inside plastering with cement mortar 1:3 (1 cement : 3 coarse
sand) 12mm thick, finished with a floating coat of neat cement
complete as per standard design :
a 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5
46.00 DSR-18.48 Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable
locking arrangement and making necessary holes for inlet, outlet Litre 0.00 11.00 0.00 0.00
and overflow pipes but without fittings and the base support for
47.00 DSR-18.77 Making core cutting machine up to 15x15 cm in R.C.C. floors and
roofs for passing drain pipe etc. and repairing the hole after
insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement Each 52.00 452.00 23504.00 0.00
: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),
including finishing complete so as to make it leak proof.
48.00 18.17 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
18.17.1 25 mm nominal bore Each 8.00 622.4 4979.20
18.17.2 32 mm nominal bore Each 4.00 689.6 2758.40
49.00 DSR Fire- Supplying, fixing, testing and commissioning of butterfly
18.11.5 valve of PN 1.6 rating with bronze/gunmetal seat duly ISI
marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required :
50.00 18.19 Providing and fixing gun metal non- return valve of approved
quality (screwed end) :
51.00 NS - 6 Providing and fixing forged brass ball valve of brass body with
hard chrome plated steel ball inside PTFE (Teflon) seat & ring
with chrome plated centre handle with female BSP threads
complete in all respects.
a 15 mm nominal bore Each 12.00 368.00 0.00 4416.00
b 20 mm nominal bore Each 28.00 513.00 0.00 14364.00
52.00 NS - 7 Providing and fixing forged brass single acting air release valve
with screwed inlet 25 mm dia.
53.00 Providing and fixing ball valve (brass) of approved quality, High or
18.18 low pressure, with plastic floats complete :.
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
Total C/F to Summary 869786.60 22716.00
3.0 External Sewerage System
54.0 DSR-2.10 Excavating trenches of required width for pipes, cables, etc
including excavation for sockets, and dressing of sides,
ramming of bottoms, depth upto 1.5 m, including getting out
the excavated soil, and then returning the soil as required, in
layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead
a 2.10.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300
55.0 2.14 Extra for excavating trenches for pipes, cables etc. in all kinds
of soil for depth exceeding 1.5 m, but not exceeding 3 m.
(Rate is over corresponding basic item for depth upto 1.5
2.14.1 ordinary rock
a 2.14.1.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300
56.0 ,19.4 Fixing SW Gully Trap Grade A Complete CI Grating, brick
masonry chamber and water tight CI cover frame of 300 x
300 mm size (inside) square mouth traps or "P" or "S" Type
57.0 ,19.7 Constructing brick masonry manhole in cement mortar 1:4 (1
cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix
(1 cement : 1.5 coarse sand (zone- III) : 3 graded stone
aggregate 20 mm nominal size), foundation
concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8
graded stone aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with floating coat of neat cement
and making channels in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size)
finished with a floating coat of neat cement complete as per
standard design :
a (A) Inside size 90×80 cm and 45 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions,
total weight of cover and frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg) : With
common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
b 19.7.2 Inside size 120x90 cm and 90 cm deep including C.I. cover
with frame (medium duty) 500 mm internal diameter, total
weight of cover and frame to be not less than 116 kg (weight
of cover 58 kg and weight of frame 58 kg)
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
58.0 18.8.1.1 Extra over item No. 25.4 for every additional depth of 0.10 m.
or part there of manhole.
a 19.8 Extra for depth for manholes
19.8.1 Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
b 19.8.2 Size 120x90 cm
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
59.0 ,19.16 Providing orange colour safety foot rest of minimum 6 mm
thick plastic encapsulated as per IS : 10910 on 12mm dia
steel bar conforming to IS : 1786 having minimum cross
section as 23 mmx25mm and over all minimum length 263
mm and width as 165mm with minimum 112 mm space
between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate
anchoring projections on tail length on 138 mm as per Each 20.00 553.70 11074.00 0.00
standard drawing and suitable to with stand the bend test
and chemical resistance test as per specifications and having
manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15
cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size) complete as per
7 DSR-19.6 Providing and laying non-pressure NP2 class (light duty)
R.C.C. pipes with collars jointed with stiff mixture of cement
mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete :
60.0 DSR-19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggregate 40 mm nominal size)
up to haunches of RCC. pipes including bed concrete as per
standard design :
61.00 19.21.1 Making connection of drain or sewer line with existing
manhole including breaking into and making good the walls,
floors with cement cincrete 1:2:4 mix (1cement: 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) cement
plastered on both sides with cement mortar 1:3 (1cement : 3
coarse sand) finished with a floating coat of neat cement and
making necessary channels for the drain etc. complete for
pipes 100 to 250mm dia.
Size :- Length = 3.0 M. Width = 2.0 M Total Depth =
Earth work in excavation over areas including disposal of
excavated earth, lead upto 50m, disposed earth to be levelled
62.00 and neatly dressed.
2.6.1 In all kind of soil upto 1.5m depth Cum 28.80 177.50 5112.00 0.00
2.26 In all kind of soil upto 1.5m to 3.0m. depth Cum 21.30 126.80 2700.84 0.00
4.1.3 Providing and laying of cement concrete in base excluding the
cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse
sand : 4 gradded stone aggregae 40mm nominal size)
6.1.1 Brick work with common bumt clay FPS(non modular) brick
of class designation 7.5 in foundation and plinth in cement Cum 4.20 7370.65 30956.73 0.00
64.00 mortar (1 cement : 4 coarse sand)
5.3 Reinforced cement concrete work in slab with 1:2:4 (1
cement : 2 course sand : 4 graded stone aggregate 20mm Cum 3.90 11505.50 44871.45 0.00
65.00 normal size).
5.22.6 Reinforcement for R.C.C. work including, straightening,
cutting bending binding and placing in position complete.
Thermo-Mechanically Treated bars of grade Fe-500D or more
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
5.9.3 Centring and shuttering including struting , proping etc and
removal of form for slab.
13.14 15mm cement plaster on rough side of mix 1:4 (1 cement : 4
19.15.1 Providing M.S. foot rest including fixing with 20x20x10 cm.
cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6
gradded aggregate of nominal size 20mm ) as per standard
69.00 design with 20x20mm sq bars.
7087 Providing and fixing C.I. tee at the inlet and outlet of septic
71.00 17.35.2.1 Providing & fixing 75mm dia vent pipes. Rm. 2.50 1044.75 2611.88 0.00
72.00 17.56.2.1 Providing & fixing of 75mm dia cast iron terminal guard. No. 2.00 340.70 681.40 0.00
19.19 Providing and fixing in position precast RCC manhole cover
73.00 and frame of required shape and approved quality.
19.19.2.2 M.D. -10- Circular shape 500mm internal diameter No. 3.00 1172.60 3517.80 0.00
19.19.1.3 M.D. -2.5- Circular shape 450mm internal diameter No. 3.00 1169.65 3508.95 0.00
19.32.1 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45
cm dry brick honey comb shaft with bricks of class
designation 75 and S.W. drain pipe 100 mm diameter, 1.8m
74.00 long complete as per standard design.
Total C/F to Summary 1102492.20 0.00
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
4.0 External Water Supply
1 18.12 Providing and fixing G.I. pipes with two coats of anti-orrosive
bitumastic paint complete with G.I. fittings including
trenching and refilling etc.
a 18.12.3 25 mm dia nominal bore Metre 10 467.75 4677.50 0.00
b 18.12.6 50 mm dia nominal bore Metre 75 762.15 57161.25 0.00
2 DSR-18.41 Providing and filling sand of grading zone V or coarser grade,
allround the G.I. pipes in external work :
a 18.41.3 25 mm dia nominal bore Metre 10 160.70 1607.00 0.00
b 18.41.6 50 mm dia nominal bore Metre 75 173.45 13008.75 0.00
3 DSR-18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick
work in cement mortar 1:4 (1 cement :4 coarse sand) for stop
cock, with C. I. surface box 100x100 x75 mm (inside) with
hinged cover fixed in cement concrete slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), i/c necessary excavation, foundation concrete
1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40
mm nominal size ) and inside plastering with cement mortar
1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a
floating coat of neat cement complete as per standard design
a 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class
designation 7.5
4 ,18.33 Constructing masonry Chamber brick work with common
burnt clay F.P.S.(non modular) bricks of class designation 150
in brick work in cement mortar 1:4 (1 cement : 4 coarse
sand) for sluice valve, with C.I. surface box 100 mm top
diameter, 160 mm bottom diameter and 180 mm deep
(inside) with chained lid and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size ), i/c necessary excavation, foundation concrete
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40
mm nominal size ) and inside plastering with cement mortar
1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a
floating coat of neat cement complete as per standard design
6.0 18.17 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
a 18.17.1 25 mm nominal bore Each 1 622.4 622.40
b 18.17.4 50 mm nominal bore Each 1 1026.65 1026.65
Total C/F to Summary 90,958.55 -
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
5.0 Storm Water Drainage System
1.0 DSR-2.10 Excavating trenches of required width for pipes, cables, etc
including excavation for sockets, and dressing of sides,
ramming of bottoms, depth upto 1.5 m, including getting out
the excavated soil, and then returning the soil as required, in
layers not exceeding 20 cm in depth, including consolidating
each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed, within a lead
2.10.1 all kind soil
2.0 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300
2.14 Extra for excavating trenches for pipes, cables etc. in all kinds
of soil for depth exceeding 1.5 m, but not exceeding 3 m.
(Rate is over corresponding basic item for depth upto 1.5
2.14.1 ordinary rock
3.0 2.14.1.1 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300
4 DSR-19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5
coarse sand : 10 graded stone aggregate 40 mm nominal size)
up to haunches of S.W. pipes including bed concrete as per
standard design :
3 ,19.16 Providing orange colour safety foot rest of minimum 6 mm
thick plastic encapsulated as per IS : 10910 on 12mm dia
steel bar conforming to IS : 1786 having minimum cross
section as 23 mmx25mm and over all minimum length 263
mm and width as 165mm with minimum 112 mm space
between protruded legs having 2 mm tread on top surface by
ribbing or chequering besides necessary and adequate
anchoring projections on tail length on 138 mm as per Each 4 553.70 2214.80 0.00
standard drawing and suitable to with stand the bend test
and chemical resistance test as per specifications and having
manufacture's permanent identification mark to be visible
even after fixing, including fixing in manholes with 30x20x15
cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size) complete as per
4.0 DSR-19.6 Providing and laying non-pressure NP2 class (light duty)
R.C.C. pipes with collars jointed with stiff mixture of cement
mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete :
5.00 19.13. Constructing brick masonry circular manhole 1.52 m internal
dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1
cement : 4 coarse sand) inside cement plaster 12 mm thick
with cement mortar 1:3 (1 cement : 3 coarse sand) finished
with a floating coat of neat cement, foundation concrete 1:3:6
(1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm
nominal size) and making necessary channel in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a floating coat
of neat cement, all complete as per standard design
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
a 19.13.1 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20
grade designation) 560 mm internal diameter conform- ing to
I.S. 12592, total weight of cover and frame to be not less than
182 kg. fixed in cement concrete 1:2:4 (1 ce- ment : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size)
including centering, shuttering all complete. (Excavation, foot
rests and 12 mm thick cement plaster at the external surface
shall be paid for separately) :
19.13.1.1 with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
6 19.14 Extra depth for circular type manhole 1.52 m internal dia (at
bottom) beyond 2.30 m :
19.14.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
7.00 DSR-19.27 Constructing brick masonry road gully chamber 50x45x60
cm with bricks in cement mortar 1:4 (1 cement : 4 coarse
sand) including 500x450 mm pre-cast R.C.C. horizontal
grating with frame complete as per standard design
19.27.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
8.00 19.21.1 Making connection of drain or sewer line with existing
manhole including breaking into and making good the walls,
floors with cement cincrete 1:2:4 mix (1cement: 2 coarse
sand : 4 graded stone aggregate 20mm nominal size) cement
plastered on both sides with cement mortar 1:3 (1cement : 3
coarse sand) finished with a floating coat of neat cement and
making necessary channels for the drain etc. complete for
pipes 100 to 230mm dia.
Total C/F to Summary 617,163.50 0.00
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
6.0 Rain Water Harvesting System
1.0 DSR-2.6 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means over areas (exceeding 30cm in depth.
1.5m in width as well as 10 sqm on plan) including geting out and
disposal of excavated earth, lead upto 50m and lift upto 1.5m, as
directed by Engineer-in-Charge.
2.0 DSR-2.25 Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and Cum 31 196.00 6076.00 0.00
watering, lead up to 50 m and lift upto 1.5 m.
a DSR-2.26 Extra for every additional lift of 1.5 m or part thereof in.
3.0 DSR-4.1 Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work up
to plinth level :
4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40
mm nominal size).
4.0 DSR-5.3 Reinforced cement concrete work in beams, suspended floors,
roofs having slope up to 15° landings, balconies, shelves,chajjas,
lintels, bands, plain window sills, staircases and spiral stair cases
up to floor five level excluding the cost of centering, shuttering, Cum 3.5 11505.50 40269.25 0.00
finishing & reinforcement with1:2:4 (1 cement: 2 coarse sand: 4
graded stone aggregate 20 mm nominal size)
5.0 DSR-5.9 Centring and shuttering including stutting, propping etc. and
removal of form for:
6.0 5.9.3 Suspended floors, roofs, landings, balconies and acees platform
7.0 DSR-5.22 Reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete.
5.22.6 Thermo-Mechanically Treated bars of Grade Fe-500D or More.
8.0 DSR-6.1 Brick work with F.P.S. bricks of class designation 75 in foundation
6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand) Cum 26 7370.65 191636.90 0.00
9.0 DSR-19.16 Providing orange colour safety foot rest of minimum 6 mm thick
plastic encapsulated as per IS: 10910 on 12mm dia steel bar
conforming to IS :1786 having minimum cross section as 23 mm x
25 mm and over all minimum length 263mm and width as
165mm with minimum 112mm space between protruded legs
having 2mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail
length on 138mm as per standard drawing and suitable to with Each 9 553.70 4983.30 0.00
stand the bend test and chemical resistance test as per
specifications and heaving manufactures permanent
identification mark to be visible even after fixing " including
fixing in manholes with 30x20x15 cm cement concrete block
1:3:6: (1 cement :3 coarse sand :6 graded stone aggregate
20mm nominal size )complete as per design.
10.00 DSR-19.19 Providing and fixing in position precast RCC manhole cover and
frame of required shape and approved quality.
19.19.3.1 HD-20 circular shape 560 mm internal diameter. Each 3 1675.70 5027.10 0.00
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
11.00 DSR-23.1 Boring/drilling bore well of required dia for casing/ strainer pipe,
by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and
submitting strata chart/bore log, including hire & running charges
of all equipments, tools, plants & machineries required for the
job, all complete as per direction of Engineer –in-charge, upto 90
metre depth below ground level.
a 23.1.1 All types of soil
12.00 DSR-23.3 Supplying, assembling, lowering and fixing in vertical position in
bore well, unplasticized PVC medium well casing (CM) pipe of
required dia, conforming to IS: 12818, including required hire and
labour charges, fittings & accessories etc. all complete, for all
depths, as per direction of Engineer –in-charge.
23.3.2 150 mm nominal size dia. Metre 15 793.25 11898.75 0.00
13.00 DSR-23.4 Supplying, assembling, lowering and fixing in vertical position in
bore well unplasticized PVC medium well screen (RMS) pipes
with ribs, conforming to IS: 12818, including hire & labour
charges, fittings & accessories etc. all complete, for all depths, as
per direction of Engineer-in-charge.
23.4.2 150 mm nominal size dia. Metre 30 807.45 24223.50 0.00
14.00 DSR-23.5 Supplying, filling, spreading & levelling stone boulders of size
range 5 cm to 20 cm, in recharge pit, in the required thickness, 3 1509.80 4529.40 0.00
for all leads & lifts, all complete as per direction of Engineer-in-
15.00 DSR-23.6 Supplying, filling, spreading & levelling gravels of size range 5 mm
to 10 mm, in the recharge pit, over the existing layer of boulders,
in required thickness, for all leads & lifts, all complete as per Cum 3 1538.25 4614.75 0.00
direction of Engineer-in-charge.
16.00 DSR-23.7 Supplying, filling, spreading & levelling coarse sand of size range
1.5 mm to 2 mm in recharge pit, in required thickness over gravel 3 1538.25 4614.75 0.00
layer, for all leads & lifts, all complete as per direction of Engineer
17.00 DSR-23.14 Providing and fixing M.S. clamp of required dia to the top of
casing/ housing pipe of tubewell as per IS: 2800 (part I), including
necessary bolts & nuts of required size complete.
Total C/F to Summary 444,964.65 0.00
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
7.00 BORE WELL
1.00 23.1 Boring/drilling bore well of required dia for casing/ strainer pipe,
by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and
submitting strata chart/ bore log, including hire & running
charges of all equipments, tools, plants & machineries required
for the job, all complete as per direction of Engineer -in-charge,
upto 90 metre depth below ground level.
All types of soil.
2.00 23.2 Boring/drilling bore well of required dia for casing/ strainer pipe,
by suitable method prescribed in IS: 2800 (part I), including
collecting samples from different strata, preparing and
submitting strata chart/ bore log, including hire & running
charges of all equipments, tools, plants & machineries required
for the job, all complete as per direction of Engineer -in-charge,
beyond 90 metre & upto 150 metre depth below ground level.
23.2.1 All types of soil.
3.00 23.1 Supplying, assembling, lowering and fixing in vertical position in
bore well, ERW (Electric Resistance Welded) FE 410 mild steel
screwed and socketed/plain ended casing pipes of required dia,
conforming to IS: 4270, of reputed & approved make, including
painted with outside surface with two coats of anticorrosive
paint of approved brand and manufacture, including required
hire & labour charges,
fittings & accessories, all complete, for all depths, as per
direction of Engineer-in-charge.
23.10.2 150 mm nominal size dia having minimum wall thickness
23.11 Supplying, assembling, lowering and fixing in vertical position in
bore well, ERW (Electric Resistance Welded) FE 410 plain slotted
(having slot of size 1.6/3.2 mm) mild steel threaded and
socketed/ plain bevel ended pipe (type A) of required dia,
conforming to IS: 8110, of reputed and approved make, having
wall thickness not less than 5.40 mm, including painted with
outside surface with two coats of anticorrosive bitumestic paint
of approved brand and manufacture, including hire & labour
charges, fittings & accessories, all complete, for all depths, as per
direction of Engineer -in-charge.
23.11.2 150 mm nominal size dia Metre 15 2102.25 31,533.75
Fire DSR 2022 Providing, laying, testing&commissioningof 'B' class
18.8 heavydutyG.I. pipeconforming to IS1239 including welding,
fittings likeelbows, tees, flanges, tapers,nuts, bolts, gaskets etc.
and fixing the pipe on the wall/ceiling with suitable
clamp/support frame and painting with two or more coats of
synthetic enamel paint of required shade complete as required
4.00 23.8 Gravel packing in tubewell construction in accordance with IS:
4097,including providing gravel fine/ medium/ coarse, in
required grading & sizes as per actual requirement, all complete Cum 6 2024.50 12,147.00
as per direction of Engineer-in-charge.
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION TWO STOREYED TAMS BUILDING AT DVC MAITHON
S. No. Description of Item Unit Qty
2023/MR Rate DSR NSR
5.00 23.12 Development of tube well in accordance with IS : 2800 (part I)
and IS: 11189, to establish maximum rate of usable water yield
without sand content (beyond permissible limit), with required
capacity air compressor, running the compressor for required
time till well is fully developed, measuring yield of well by "V"
notch method or any other approved method, measuring static Hour 12 1085.05 13,020.60
level & draw down etc. by step draw down method, collecting
water samples & getting tested in approved laboratory, i/c
disinfection of tubewell, all complete, including hire & labour
charges of air compressor, tools & accessories etc., all as per
requirement and direction of Engineer-in-charge.
6.00 23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the
bottom of pipe assembly of tubewell as per IS:2800 (part I).
23.15.2 150 mm nominal size dia Each 2 322.00 644.00
DSR Fire-18.11 Supplying, fixing, testing and commissioning of butterfly valve of
PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
6.00 NS-8 Supply, Installation, testing & Commissioning of suitable capacity
and type of submersible pump set capable to discharge 25,000
ltrs. of clean filtered water from a 250 mm x 150 mm deep
tubewell at a total head of 60 meter, complete with control Set 1 75066.00 0.00 75066.00
panel, bend, gate valve nipple supporting clamp, 35 metres of
neoprene cable etc. complete as required.
Digitally signed by SUPARNA
Name of Project : PROPOSED CONSTRUCTION OF TWO STOREYED AT DVC
MAITHON SUBSTATION.
NSI Amount (Rs.)
S. No. Description
I. FIRE PUMPS AND ELECTRICAL WORKS 1,675,482.00 -
II FIRE HYDRANT WORKS 261,036.00 -
III PIPING FOR FIRE FIGHTING SYSTEM 2,219,601.85 -
IV FIRE NON SCHEDULED ITEMS - 469,835.16
Grand Total A+B 4,625,955.01
Grand Total A+B 4,625,955.01
Digitally signed by SUPARNA
CONSTRUCTION OF TWO STOREYED TAMS AT DVC MAITHON SUBSTATION.
DETAILED ESTIMATE
S. NO. SOR / DSR-
2022 / NSI DESCRIPTION
Item NO Qty. Unit DSR-2022 NSI DSR NSI
SUBHEAD-I(A): FIRE PUMPS AND HYDRANT WORKS (NON SCHEDULED ITEMS)
1 FIRE PUMPS - ELECTRICAL
Supplying, installation, testing and commissioning of Electric driven
Main Fire Pump suitable for automatic operation and consisting of
18.1 following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast
iron body & bronze impeller with stainless steel shaft, mechanical
a seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed
1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC
supply with IP 55 protection for enclosure, horizontal foot mounted
type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard,
c foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti
d vibration pads.
Supplying, installation, testing and commissioning of electric driven
pressurisation pump suitable for automatic operation and consisting
3 of following, complete in all respects, as required : (Jockey Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and
bronze impeller with stainless steel shaft, mechanical seal
conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of
protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
2 FIRE PUMPS - DIESEL
Supplying, installation, testing and commissioning of diesel engine
driven main fire pump suitable for automatic operation and
consisting of following, complete in all respects, as required : (Diesel
18.2 Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body
and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant IS standard complete with auto starting
mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly
insulated with 50 mm thick glass wool with 1.0 mm thick aluminium
sheet cladding, residential silencer, instruments and protection as
per standard specification, stop solenoid for auto stop in the event
of fault with audio indications, painted with post office red colour
etc. as required.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
18.4 FIRE ROOF PUMPS - ELECTRICAL
Digitally signed by SUPARNA
Supplying, installation, testing and commissioning of electric driven
terrace pump suitable for automatic operation and consisting of
following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body
and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520.
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of
protection for enclosure, horiziontal foot mounted type with Class-
'F' insulation, conforming to IS-325.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
18.5 Fabricating, supplying, testing and commissioning of electrical
control panel of cubicle construction, floor mounted type, fabricated
out of 2mm thick crca sheet, compartmentallised and hinged
lockable doors, dust and vermin proof, powder coated approved
shade after 7 tank treatment process, cable alley interconnection,
having switchgears and accessories mounting and internal wiring,
earth terminals, numbering etc., complete in all respects, suitable for
operation on 415V, 3 phase 50 Hz., AC supplywith enclosure
protection class IP-42as required.
COMMON PANEL IN FIRE PUMP HOUSE.
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating
Digital Voltmeter 0-500V with selector switch
Ammeter (0-400 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 800Amps
Main fire pump and Sprinkler pump
200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic
Star/Delta starter suitable for 100 hp pump with overload
protection, current sensing type single phase preventor complete
with all acceessories and internal wiring required for automatic
operation, selector switch for local/remote, auto/manual/OFF
operation. - 2 sets
100 A, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully
automatic Star/Delta starter with overload protection, current
sensing type single phase preventor complete with all acceessories
and internal wiring required for automatic operation, selector switch
for local/remote, auto/manual/OFF operation. - 2 sets
Diesel Engine Control
Control for Diesel Engine comprising:-
Auto / Manual selector switch & 3 attempt starting device, timers
and relays as required, push buttons, start / stop in manual mode.
Indication lamp for High / Low Lub. Oil pressure, High Water Temp.
and Engine ON indication.
Battery charger suitable for 12V / 24 V DC with boost and tickle
selector switch, 0-30 V DC volt meter, 0-20A DC Ammeter.
All standard relays and acessories for automatic operation of diesel
Diesel Engine Control
Control for Diesel Engine comprising:-
Auto / Manual selector switch & 3 attempt starting device, timers
and relays as required, push buttons, start / stop in manual mode.
Indication lamp for High / Low Lub. Oil pressure, High Water Temp.
and Engine ON indication.
Digitally signed by SUPARNA
Battery charger suitable for 12 V / 24 V DC with boost and tickle
selector switch, 0-15 V / 0-30 V DC volt meter, 0-20A DC Ammeter.
All standard relays and accessories for automatic operation of diesel
SYSTEM CONTROLLER
Designing, Supply, Installation, Testing and Commissioning of system
controller to control operation of Main Electric Fire Pump, Diesel
Pump in sequence as per specification consisting of relays, timets,
sensors, annunciation window for fault indication, complete as per
Note - All cabling, earthing, GI strip and cable tray including all
electrical related accessories included in electrical tender.
Providing & fixing of pressure switch in M.S. pipe line including
4 18.22 connection etc. as required. 4.00 Each 1,546.00 0.00 6184.00 -
5 18.20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS
sheet, 1200 mm in height with air release valve on top and flanged
connection to riser, drain arrangement with 25 mm dia gun metal
wheel valve with required accessories, pressure gauge and
paintingwith synthetic enamel paint of approved shade as required.
FIRE ELECTRICAL WORKS (ELECT DSR 2022)
6 5.4 Supplying and Earthing with GI earth plate 600mm x 600 mm x 6mm
thick including accessories and providing masonary enclosure with
cover plate having locking arrangement and watering pipe etc,
with charcoal/ coke and salt as required.
Supplying and laying 25 mm x 5 mm. G.I. strip in 40 mm dia. G.I.
Pipe from earth electrode, including connection with GI nut, bolt,
spring, washer excavation and re-filling etc as required.
8 5.15 Providing & fixing 25mm x 5mm G.I. strip on surface or in recess for
connections etc. as required.
9 5.18 Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for
loop earthing alongwith existing surface/ recessed conduit/ submain
wiring/ cable as required.
Supplying, fabricating and installing following size of perforated
painted with powder coating M.S. cable trays,with perforation not
more than 17.5%, in covenient section, joined with connectors,
suspended from the ceiling with MS suspenders including bolts &
nuts, painting suspenders etc. as required. 0.00
4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness 35.00 Rm 543.00 0.00 19005.00 -
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness 28.00 Rm 777.00 0.00 21756.00 -
11 7.7.1 Laying and fixing of One number PVC Insulated and PVC
Sheathed/XLPE power cable of 1.1 kV grade of size not exceeding 35
sqmm on surface as required. 20.00 RM 39.00 0.00 780.00 -
7.7 Laying and fixing of One number PVC Insulated and PVC
Sheathed/XLPE power cable of 1.1 kV grade of folloing size on wall
surface as required.
Aboved 35 sq mm and upto 95 sq mm (clamed with 25x3mm MS flat
Supplying of all materials and making terminations of 1.1 KV grade
aluminium multicore cables of the following sizes. The work includes
cable glanding using brass plated double compression glands, sizing
the core leads, removing insulation, fixing suitable crimping type
copper lugs/ thimbles by using hydraulic crimping tools with correct
size of the dies, shaping the leads and neatly connecting the same to
the equipment terminals.
a 9.1.25 3.5 Core 120 sq. mm. Armoured Aluminium cable. 15.00 Mtr 613.00 0.00 9195.00 -
b 9.1.21 3.5 Core 35 sq. mm. Armoured Aluminium cable. 40.00 Mtr 369.00 0.00 14760.00 -
Digitally signed by SUPARNA
c 9.1.8 3.5 Core 16 sq. mm. Armoured Aluminium cable. 21.00 Mtr 270.00 0.00 5670.00 -
Control Cabling (PVC insulated and PVC sheathed, armoured, Copper
13 1.17 Conductor of 1.1 KV grade on existing cable trays).
TOTAL C/F TO SUMMARY 1,675,482.00 -
SUBHEAD-II (A): FIRE HYDRANT WORKS (DSR 2019)
Fire Hose Cabinet
Supplying and fixing single headed internal hydrant valve with
instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with
cast iron wheel ISI marked conforming to IS 5290 (Type -A) with
1 18.9 blank Gunmetal/Stainless Steel cap and chain as required : 8.00 Set 7,646.00 0.00 61168.00 -
18.9.1 Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with
1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel
coupling and cast iron wheel, ISI marked, conforming to IS 5290
(type A) with blank Gunmetal/Stainless Steel cap and chain as
2 18.1 required :
d 10.1 Single headed Gunmetal 0.00 Set 7,646.00 0.00 0.00 -
Supplying and fixing first-aid Hose Reel with MS construction spray
painted in post office red, conforming to IS 884 complete with the
3 18.17 following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall
Connections from riser with 25 mm dia stop gun metal valve & M.S.
Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63
mm dia male and female couplings duly bound with GI wire, rivets
4 18.16 etc. conforming to IS 636 (type-A) as required :
Supplying & fixing 63 mm dia gun metal short branch pipe with 20
mm nominal internal diameter size nozzle conforming to IS 903
suitable for instantaneous connection to interconnect hose pipe
5 18.18 coupling as required :
18.18.1 Providing and fixing of standard short size GM branch pipe with
nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia
coupling complete IS marked & TAC approved. 8.00 Nos. 2,416.00 0.00 19328.00 -
Supplying and fixing orifice plate made out of 6 mm thick stainless
steel (Grade 304) with orifice of required size to be fitted between
flange & landing valve of external and internal hydrants to reduce
pressure at the outlet to the level of 3.5 kg/cm2 complete as
Supplying and fixing of fire brigade connection of cast iron body with
gun metal male instantaneous inlet couplings complete with cap and
chain as reqd. for suitable dia MS pipe connection conforming to IS
7 18.19 904 as required :
TOTAL C/F TO SUMMARY 261,036.00 -
SUBHEAD-III (A): PIPING FOR FIRE FIGHTING SYSTEM
Providing and fixing C.I. double acting air valves of approved quality
CIVIL DSR with bolts, nuts, rubber insertions etc. complete ( The tail pieces,
1.0 18.59 tapers etc. if reqd. will be paid separately)
Digitally signed by SUPARNA
2.1 Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms,
depth upto 1.5 m including getting out the excavated soil, and then
returning the soil as required, in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering,
etc. and disposing of surplus excavated soil as directed, within a lead
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm
4.5 Providing and fixing up to floor five level precast cement concrete
string or lacing courses, copings, bed plates, anchor blocks, plain
window sills, shelves, louvers, steps, stair cases, etc. including
hoisting and setting in position with cement mortar 1:3 (1 Cement : 3
coarse sand), cost of required centering, shuttering and finishing
smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand)
on exposed surfaces complete.
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate
Constructing masonary chamber 90 x 90 x100 cm. inside with 75
class designation brickwork in cement mortar 1:5 ( 1 cement : 5 fine
sand) for sluice valve with CI surface box 100 mm top dia. 180 mm
bottom dia. And 180 mm deep (inside) with chained lid and RCC top
slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) necessary excavation foundation concrete 1 :5
:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm
nominal size and inside plastering with 1:3 (1 cement : 3 coarse
sand) 12 mm thick finished with a floating coat of neat cement
4 18.34.1 complete as per standard design with FPS bricks 24.00 Each 17577.9 0.00 421869.60 -
Supplying, fixing, testing & commissioning of double flanged sluice
valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat,
ISI marked complete with nuts, bolts, washers, gaskets and
5 18.12 conforming to IS 780 of following sizes as required :
Providing, installation, testing and commissioning of stainless steel Y-
strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,
6 18.15 sheet with 3 mm dia holes with stainless steel flange.
Providing, installation, testing and commissioning of non-return
valve of following sizes confirming to IS:5312 complete with rubber
7 18.14 gasket, GI bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN
1.6 rating with bronze/gunmetal seat duly ISI marked complete with
nuts, bolts, washers, gaskets conforming to IS 13095 of following
8 18.11 sizes as required :
Digitally signed by SUPARNA
Providing laying, testing & commissioning of 'C' class heavy duty MS
Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees,
flanges, tapers, nuts bolts, gaskets etc. in ground including welding,
excavation & providing cement concrete blocks as supports,
anticorrosive treatment with coaltar/asphalt tape as per IS 10221,
9 18.6 refilling the trench etc. of following sizes complete as required.
Providing, laying, testing & commissioning of 'C' class heavy
duty MS pipe conforming to IS 3589/IS 1239 including Welding,
fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets
etc. and fixing the pipe on the wall/ceiling with suitable
clamp/support frame and painting with two or more coats of
synthetic enamel paint of required shade complete as required
TOTAL C/F TO SUMMARY 2,219,601.85 -
SUBHEA- III (B): FIRE NON SCHEDULED ITEMS
Providing and fixing carbon-di-oxide type fire extinguishers
consisting of welded M.S. cylindrical body, internal discharge tube,
discharge nozzle, suspension bracket, conforming to IS 15683,
finished externally with red enamel paint and fixed to wall with
1 M.R. brackets complete with internal charges.
Providing and fixing (ABC Dry Chemical Powder ) type Fire
Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI mark
complete with brass forged squeeze grip type valve fitted with
pressure gauge , pressurize with dry Nitrogen gas filled, with
discharge nozzle with wall mounting bracket complete with internal
2 M.R. charges.
Providing and fixing mechanical foam type Trolley Mounted Fire
3 Extinguisher of bearing to IS:10568/IS13385/IS13386 with dis
Providing and fixing Carbon Dioxide Type Trolley Mounted Fire
Extinguisher of as per IS: 2878 with discharge time of 10 to 20 sec/15
4 to 36sec/20 to 60sec respectively.
a 22.5 Kg. CO2 Fire Extinguisher 1.00 Nos. - 15,867.73 0.00 15,867.73
Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door
frame 900x2100 door capable of accommodating fire hose reel,
landing valve, hose pipes, fittings & accessories. The door shall have
a front glass with lock and key arrangement & shall be painted with
post office red colour (approval shall be taken on the basis of
submitted sample before ordering) Cost of fire extinguishers not
included in item rate. (Liasioing with civil contractor for making
5 900x600x2100 Recessed type mansoary box (by civil contractor). 6.00 Each - 13,836.66 0.00 83,019.97
Digitally signed by SUPARNA
Providing and fixing of TAC approved 1.6mm thick M.S. fire hose
cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable
of accommodating landing valve, hose pipes, fittings & accessories.
The box shall have a front glass door with lock and key arrangement
& shall be painted with post office red colour (approval shall be
taken on the basis of submitted sample before ordering) - for
6 external and roof hydrant. 2.00 Each - 8,565.55 0.00 17,131.10
7 Providing and fixing of Fire Axe 6.00 Each 658.89 0.00 3,953.33
Supply, installation testing & commissioning Foot Valve lift type as
per specifications to the satisfaction of Project-in-charge - 150mm
Providing and fixing brass ball valve with SS 304 Stem and ball, teflon
NS-6 ROOF FIRE PANELS:
Supply, installation, testing and commissioning of
followingintegrated, cubicle type,dead front, extensible, sheet steel
control panel. The panel shall be suitable for 440 volts, 50 cycles, 4
The following components and accessories shall be mounted with
ineach control panel.
One no 100 amps TP incoming MCCB with the following:
0-500 volts 96 x96 square mm voltmeter with slector switch and
control fuses- 1 SET
0-100 amps 96 x96 square mm ammeter with CT's and slector
Including all elecal works
Phase indicating lamp with toggle switches.
Indication lamps for ON/OFF/TRIP status
Outgoing Feeders / Starters as below:
100 ATP MCCB with star / delta as starter suitable for 30 HP motor
for Downcomer Pump - 1 Set
Provision in control panel to connect flow switch for autmatic
operation of roof fire pumps.
TOTAL C/F TO SUMMARY 469,835.16
Digitally signed by SUPARNA
SUMMARY OF COST HVAC WORK
S.No. Section`s System Description DSR (AMMOUNT) NSR (AMMOUNT)
1 SECTION-A VRF/VRV AC SYSTEM (DSR-2025) 11335770.00 5928385.00
2 SECTION-B AIR DISTRIBUTION WORK FOR AC SYSTEM (DSR-2022) 2104185.50 57061.00
3 SECTION-C MECHANICAL VENTILATION EQUIPMENTS 0.00 143470.00
4 SECTION-D HVAC ELECTRICAL WORKS:(DSR-2022) 205294.00 1412055.00
GRAND TOTAL HVAC (DSR+NSR) 21186220.50
GRAND TOTAL HVAC (DSR+NSR) 21186220.50
Digitally signed by SUPARNA
TAMS BUILDING MAITHON
DSR-2025/22 / DSR/NSR DSR NSR
SI.No Description Unit Qty.
NSR ITEMS (Rate) (Amount) (Amount)
A) VRF/VRV AC SYSTEM
1 OUT DOOR UNITS:
Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant
Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating
having 100% hermetically sealed inverter type twin Rotary/Scroll
Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP
modules, microprocessor based Controller, top discharge type condensing unit(s), with R-
410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete
as required. To have better efficiency condenser fan shall be capable to operate at different
speed with respect to load. The unit shall deliver the rated capacity and in confirmation as
per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature
without tripping. The system shall be able to deliver 100% of the rated capacity upto 39
Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC
power supply and BMS compatible. The unit shall be filled with first charge of the
refrigerant and ready for use as required. The condenser should be coated with a
hydrophilic film to prevent water accumulation on the surface of the heat exchanger,
enhance water dispersion, and reduce the risk of degradation, thereby improving overall
performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the
unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as
below and complete as per CPWD specification, connections, inter connections etc. as
required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70
ISEER 6.6 for ECSBC+ Building)
2 VRV/VRF INDOOR UNITS:
Supply, Installation, Testing and Commissioning of following minimum capacity and
external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor
unit equipped with washable synthetic media pre-filter, fan section with low noise
fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil,
electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain
2.1 DSR-2025-7.11 pan, drain pump, other necessary supports etc., suitable for operation on single phase AC
supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon
receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust
air flow as per room requirement automatically. The cooling capacity of indoor unit will be
at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
b) DSR-2025-7.11.7 3.2 TR Ductable unit Nos. 1 40166.00 40166.00
c) DSR-2025-7.11.8 4.0 TR Ductable unit Nos. 2 45997.00 91994.00
e) DSR-2025-7.11.8 4.0 TR Ductable unit TFA Nos. 4 45997.00 183988.00
f) DSR-2025-7.12.2 5.6 TR Ductable unit TFA Nos. 2 74394.00 148788.00
Supply, Installation, Testing and Commissioning of following minimum capacity 4 way
Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-
filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil
section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill,
necessary supports, vibration Isolation, Corded remote control etc., suitable for operation
on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units
must shut down upon receiving a singal from the BMS System/Fire Signals. The system
shall be capable to adjust air flow as per room requirement in auto mode. The cooling
capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C
WB temperature.
a) DSR-2025-7.4.1 0.8 TR Cassette unit with drain pump Nos. 4 22304.00 89216.00
b) DSR-2025-7.4.3 1.2 TR Cassette unit with drain pump Nos. 8 38601.00 308808.00
c) DSR-2025-7.4.4 1.6 TR Cassette unit with drain pump Nos. 1 39464.00 39464.00
d) DSR-2025-7.4.5 2.0 TR Cassette unit with drain pump Nos. 2 39734.00 79468.00
e) DSR-2025-7.4.6 2.3 TR Cassette unit with drain pump Nos. 10 40814.00 408140.00
f) DSR-2025-7.4.7 2.8 TR Cassette unit with drain pump Nos. 23 40814.00 938722.00
g) DSR-2025-7.4.8 3.2 / 3.6 TR Cassette unit with drain pump Nos. 1 44269.00 44269.00
Supply, Installation, Testing and Commissioning of following minimum capacity High wall
type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan
section with low noise fan/dynamically balanced blower, multispeed motor, coil section
with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control,
2.3 DSR-2025-7.8 drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single
phase AC supply, complete as required. The Indoor units must shut down upon receiving a
singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as
per room requirement automatically. The cooling capacity of indoor unit will be at air inlet
conditions of 27 Degree C DB and 19 Degree C WB temperature.
Digitally signed by SUPARNA
DSR-2025/22 / DSR/NSR DSR NSR
SI.No Description Unit Qty.
NSR ITEMS (Rate) (Amount) (Amount)
3 DX AHU COMPATIBLE WITH VRV/VRF ODU
Supply, Installation, testing and commissioning of Factory built ceiling suspended chilled water
double skin type horizontal/vertical air handling units of following capacity, made of 25mm thick
panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside
layer with Polyurethane Foam (PUF) insulation factory injected between them by injection
moulding machine, complete with blower section with blower suitable for static pressure as
required, minimum 2 bend PVC eliminators, cooling coil section with aluminum finned copper
tubes (tubes thickness not less than 0.5mm) cooling coil of 4 row deep, filter section with 50mm
thick metal viscous/ washable synthetic type air prefilters, belt drive package with Totally
Enclosed Fan Cooled (TEFC) drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz,
3 Phase AC supply suitably designed for Variable Frequency Drive (VFD) applications, drain
connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure
gauges (2 nos.)and industrial type thermometers (2 nos.) and industrial type thermometers (2
nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration
Isolation arrangement, noise level shall not exceed 70 dBA. AHU shall be AHRI/Eurovent certified,
fan shall be AMCAcertified etc. Complete as per CPWD specification/drawings and as directed by
Engineer-in-Charge. (Total static pressure considered is max. 50 mm WC).
a) DSR-2025-11.1.10 CS AHU: 10000 CFM (22.5 TR) 4 Row Deep Coil at 45 mm static pressure. Nos. 2 254530.00 509060.00
4 AIR HANDLING UNIT KIT:
Supply, installing, testing and commissioning of Electronic expansion valve & control kit
compatible to connect the following Dx type AHU with the VRF outdoor unit, the AHU kit should be
complete with Control box for flow of refrigerant so as to modulate the capacity of AHU as and
when required in sync with VRF outdoor unit, the AHU kit should have corded remote control, and
capability to control the AHU fan , speed of AHU Fan.
a) NSR-1 Suitable for AHU :10000 cfm 22.5TR AHU 5.5 KW MOTOR ) Nos. 2 47220.00 94440.00
Supply, installing, testing and commissionin of VFD designed for HVAC applications with
built-in PID controller, control panel (keypad & display) , IP-65 enclosure for use on
standard centrifugal plug fans. The display should be in alpha-numeric characters and
programming facility should be in user-friendly HVAC terminology. VFD’s shall have built-
in harmonic filters. No. VFD panel to be provided with digital display showing electrical
parameters like voltage, current and power consumption. No. VFD shall be installed in a
dedicated externalIP-65 enclosure andthe inter connecting wires between driver and MCC
shallbe included. VFD cost included in this AHU price itself.
a) Suitable for -5.5 kw ahu motor Nos. 2 35590.00 71180.00
6 DX TYPE PRECISION AIR CONDITIONING UNITS:
Supply, Installation, Testing and Commissioning of DX type precision air-conditioning
units with necessary painted MS stand with anti vibration pad for indoor and outdoor
units, self contained floor mounted . The unit should operatre on high reurn air
temperature upto 43 Deg. C.
The cabinet Shall be provided with double skin side panels with inner panel of minimum
thickness of 0.8mm and outer panel of thickness of 1.0mm and fabricated out of heavy
gauge steel sheets with minimum 19 mm thick 60kg /cum density Rockwool insulation
sandwitched in between.
The Indoor unit shall comprise of Digital scroll compressor , corrossion resistant
Evaporator fan section with statically & dynamically balanced plug type direct driven by
Electronically Commutated (EC) motor, Straight /Slant type Evaporator DX Cooling Coil
with hydrophilic coating, Microprocessor controllers, Expansion valves, Driers, high
efficiency HDPE washable filters of MERV 8, Suction and Discharge piping, Internal power
and Control wiring, Heaters, HP/LP Cutouts, with Steam Elctrode type humidifier . Power
and Control contactor ,water leak detectors contacotrs and Other Electrical accessories.
EER of not less than 11.1 BTUH/watt (COP of not less than 3.25) at ARI rating conditions.
The Outdoor Condenser unit shall comprise of Condenser fans & motor, Condenser cooling
coil (Copper coil with aluminium fins), Isolater switch.
The unit shall be suitable for operation on 415 Volts, 50 Hz, 3 Phase, 4 Wire AC supply.
Each unit should be having individual display panel, which shall display date, time, actual
& set values, operating conditions, signal faults, collective faults, limiting values and PAC
wellness alarm / service alarm to reduce the down time and unit memory shall hold the
200 most recent events with ID number, time and date stamp for each event.
Microprocessor Controls:( Touch Screen Display)
Following information shall be available on the display on the units:
a) Room temperature and humidity.
b) Supply fan working status.
c) Current date and time.
d) Electric heaters working status.
e) Manual / Auto unit status.
f) Temperature set point.
g) Humidity set point.
h) Working hours of main component i.e. fan, heater, humidifier
Following alarms should be available:
Temperature High / No Air Flow
Compressor 1 High / Low Pressure
Temperature high / low
Humidity high / low
Indoor unit shall be selected to ambient temp. of 35°C & return air temperature 24±1°C &
50±5% RH.,Refrigerent -R410A, to achieve 20 deg C inside temperature ear round
particularly during monsoon with the operation of heaters as may be required irespective
of the eqipment load inside the Server Room.
a) NSR-2 Top Discharge Type PAC Unit - 10.0 TR (4W+1S) Nos. 5 1125920.00 5629600.00
Digitally signed by SUPARNA
DSR-2025/22 / DSR/NSR DSR NSR
SI.No Description Unit Qty.
NSR ITEMS (Rate) (Amount) (Amount)
7.0 REFRIGERANT PIPING:
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen
testing of following nominal sizes of soft/hard drawn copper refrigerant piping for
VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger
DSR-2025-7.14 supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular
insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of
19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per
specifications etc. as required :
a) DSR-2025-7.14.1 6.40 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 40 256.00 10240.00
b) DSR-2025-7.14.2 9.50 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 245 346.00 84770.00
c) DSR-2025-7.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 250 487.00 121750.00
d) DSR-2025-7.14.4 15.8 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 275 615.00 169125.00
e) DSR-2025-7.14.5 19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 330 739.00 243870.00
f) DSR-2025-7.14.6 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 155 904.00 140120.00
g) DSR-2025-7.14.7 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 75 1068.00 80100.00
h) DSR-2025-7.14.8 28.5 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation Rmt 165 1157.00 190905.00
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick
41.2 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick
Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same
DSR-2025-7.13 Original Equipment Manufacturer (OEM) make as of ODUs and IDUs
a) DSR-2025-7.13.1 Y- Joints set (Indoor units) Set 60 4535.00 272100.00
b) DSR-2025-7.13.2 Y- Joints set (Outdoor units) Set 8 8098.00 64784.00
6.0 DRAIN PIPING :
Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm
thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications &
TOTAL SECTION A 11335770.00 5928385.00
B) AIR DISTRIBUTION WORK FOR AC & VENTILATION SYSTEM
7.0 Sheet Metal Duct:
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter
dampers, vanes, hangers, supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter
dampers, vanes, hangers, supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
Supplying, fixing. testing commissioning of GI volume control duct damper complete
8.0 16.13 with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, in accordance with Sqm 5.5 7046.00 38753.00
approved shop drawings and specifications complete as required.
Supplying & fixing of powder coated extruded aluminium Air Grills with aluminium
volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Air Grills without volume
control dampers complete as required.
Digitally signed by SUPARNA
DSR-2025/22 / DSR/NSR DSR NSR
SI.No Description Unit Qty.
NSR ITEMS (Rate) (Amount) (Amount)
Supplying, fixing. testing commissioning of Supply Air Diffuser of powder coated
11.0 16.17 extruded aluminium with aluminium volume control dampers with anti smudge ring & Sqm 10.5 12184.00 127932.00
removable core.
Supplying, fixing. testing commissioning of Return Air Diffuser of powder coated
12.0 16.18 extruded aluminium without volume control dampers with anti smudge ring & Sqm 10.5 8121.00 85270.50
removable core.
Supply and fixing of Acoustic lining of supply air duct and plenum with 25 mm thick
resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of
1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper
and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with
cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as
per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish
closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats
14.0 16.23 of cold setting adhesive (CPR X compound). The joints shall sealed with 50 mm wide and 3
mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as
Supply, installation and balancing of extruded aluminium powder coated air louvers
complete with aluminium wire mesh bird screen as per specifications.
Supplying, fabricating, installing and testing of 200mm wide fire retardent Silicone
16.0 NSR-7 Coated (Both Side) Fiberglass Cloth material Flexible Connection between duct & Rmt 25 1540.00 38500.00
equipment complete as per the drawings/specifications.
TOTAL SECTION B 2104185.50 57061.00
C) MECHANICAL VENTILATION EQUIPMENTS
17.0 INLINE FANS
Supply, Installation, Testing and commissioning of Fresh/exhaust air fan
suitable for Inline mounting comprising of forward curved centrifugal blower
complete with induction motor, metal clad MCB, canvas connection all
compete as required. Motor shall be suitable for single phase, 230 volts, 50Hz
AC. supply as per specifications of following capacities: Noiselevel should not
exceed 65dB(A)at 3 meter in room condition.
a) NSR-8 700 cfm capacity with 10 mm static pressure Nos. 6 13800.00 82800.00
18.0 PROPELLER FANS
Supply, Installation, Testing and commissioning of wall mounted propeller type exhaust
fans of Axial Flow type with light weight type PVC / aluminium impellers with aerofoil
contours for high efficiency and low noise. The fan shall be supplied complete with and
gravity louvers with a suitable Squirrel cage induction motor.
TOTAL SECTION C 143470.00
D) HVAC ELECTRICAL WORKS:
19 ELECTRICAL WORKS
Design, fabrication, supply, installation, testing and commissioning of panels fabricated out
of 2mm thick for structural members and 1.6mm thick for door and covers CRCA sheet in
cubicle compartmentalize free standing floor mounted/ wall mounted powder coated with
reinforcement wherever necessary. Cable gland plates shall be provided on top and
bottom. Panels have 2 Nos. earthing terminals. Panels shall be suitable for 415V, 3-phase, 4-
wire, 50Hz supply system lifting hooks shall also be provided in case of large panels.
Degree of ingress protection shall be IP42.
19.1 ODU PANEL (TERRACE)
Incomer (1 No.):
500 A, TPN MCCB (35 KA) with adjustable O/L fix short circuit
0-500 Volts, digital Voltmeter with S/S and shall be protected by 2 Amps MCBs.
0-500 Amps digital Ammeter and 500/5A, 10VA, CL-1 CTs and selector switch.
Phase indicating lamps and shall be protected by 2 Amps MCBs.
630 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves,
(6) Nos. 4 pole 100A RCBO
(3) Nos. 4 pole 63A RCBO
NSR-12 (1) Nos. 4 pole 32A MCB (Spare) Set 1 256000.00 256000.00
Digitally signed by SUPARNA
DSR-2025/22 / DSR/NSR DSR NSR
SI.No Description Unit Qty.
NSR ITEMS (Rate) (Amount) (Amount)
19.2 ODU PANEL (TERRACE FOR DVC CONTROL ROOM)
Incomer (1 No.):
150 A, TPN MCCB (35 KA) with adjustable O/L fix short circuit
0-500 Volts, digital Voltmeter with S/S and shall be protected by 2 Amps MCBs.
0-150 Amps digital Ammeter and 150/5A, 10VA, CL-1 CTs and selector switch.
Phase indicating lamps and shall be protected by 2 Amps MCBs.
200 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves,
(2) Nos. 4 pole 80A RCBO
NSR-13 (1) Nos. 4 pole 32A MCB (Spare) Set 1 28000.00 28000.00
19.3 PAC PANEL (GROUND FLOOR FOR SERVER ROOM)
Incomer (1 No.):
150 A, TPN MCCB (35 KA) with adjustable O/L fix short circuit
0-500 Volts, digital Voltmeter with S/S and shall be protected by 2 Amps MCBs.
0-150 Amps digital Ammeter and 150/5A, 10VA, CL-1 CTs and selector switch.
Phase indicating lamps and shall be protected by 2 Amps MCBs.
200 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves,
(5) Nos. 4 pole 40A MCB(4W+1S)
NSR-14 (1) Nos. 4 pole 32A MCB (Spare) Set 1 17000.00 17000.00
20.0 SWITCH SOCKET FOR INLINE & PROPELLER FAN (SINGLE PHASE)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface
1.56 or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A Set 23 676.00 15548.00
modular switch, connections etc. as required.
21.0 MCB FOR AHU`S VFD
Supplying and fixing 5A to 32A rating 230/415V "C" curve, miniature circuit breaker
2.10.6 suitable for inductive load of following poles in the MCB DB complete with connections, Set 2 1228.00 2456.00
testing and commissioning etc. as required.
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed Copper
conductor armoured cables including , clamped includes anchor fastners wall with
suitable clamps, saddles fixing bolts including connecting testing and commissioning etc as
per specification complete as required.
Supplying and installing following size of perforated painted with powder coating MS.
cable trays with perforation not more than 17.5%, in convenient sections, joined with
connectors, suspended from the ceiling with MS, suspenders including bolts & nuts,
painting suspenders etc as required.
Supplying and fixing of following sizes of steel conduit along with accessories in
23.0 1.20 surface/recess including painting in case of surface conduit, or cutting the wall and making
good the same in case of recessed conduit as required.
a) 1.20.2 25 mm dia. ISI marked, steel conduit Rmt 15 256.00 3840.00
Supplying and fixing of following sizes of medium class PVC conduit along with accessories
24.0 1.21 in surface/recess including cutting the wall and making good the same in case of recessed
conduit as required.
a) 1.21.2 25 mm dia. ISI marked, PVC conduit Rmt 20 145.00 2900.00
25.0 WIRING IN EXISTING CONDUIT / PVC CASING CAPPING WITH COPPER CONDUCTOR
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single
core cable in the existing surface/ recessed steel/ PVC conduit as required.
26.0 EARTHING SYSTEM
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as
TOTAL SECTION D 205294.00 1412055.00
HVAC WORK TOTAL 13645249.50 7540971.00
Digitally signed by SUPARNA
PROJECT: PROPOSED CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON ,SUBSTATION
Wooden Flooring,Acoustic Wall Panel,Fire Door
BASED ON DSR 2023/MR
S.No. ITEAM NO DESCRIPTION Unit Quantity Rate Amount (SI) Amount (NSI)
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws
1 DSR 11.33 complete with :
11.33.1 Second class teak wood Sqm 349.20 4508.95 1,574,514.41
Acoustic Wall Panelling at all heights as per design:- Providing & fixing of Petawood acoustical wall
panels of 18mm thickness square edge in required design, the panels are manufactured with
combination of Polyethylene Terephthalate & wood slat having weight of 7.8kg/m2 and system NRC of
0.80, panels should be fire resistant as per B1 Class. The panel to be glued over 120x12mm thick HDHMR
strip which is fixed over 50mm GI framework consisting of 48x36x34x0.5mm thick GI Studs wall channels
& 50x35x35x0.5mm floor channels @ 600mm c/c. The cavity of GI framework should be inserted with
2 NS thermaly bonded polyester fibre of 50mm thick 1000 GSM density for better insulation. The panel size Sqm 320.90 6875.00 2,206,215.00
will be 600 x 600/1200/2400 mm in different colors as per choice of architect or engineer in charge. The
panels to be pasted on the HDHMR Strip with SR505 adhesive . The work to be done complete as per the
design & instructions of Engineer-in-Charge including all accessories / hardware as required.
3 Acoustic Fire Door
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60
mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not
less than 120gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The
frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm . The
frame will have a provision of G.I. anchor fastners 14 nos ( 5 each on vertical style & 4 on
horizontal style of size M10 x 80 ) suitable for fixing in the opening along with factory made
template for SS ball bearing hinges of Size 100x89x3mm for fixing of fire rated glazed shutter .
The frame shall be finished with a approved fire resistant primer or powder coating of not less
than 30 micron in desired shade as per the directions of Engineer - in- Charge . (Cost of SS ball
bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating
conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical
styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of
1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool
insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball
bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved
fire resistant primer or powder coating not less than 30 micron etc all complete as per direction
of Engineer-in-Charge (panelling to be paid for seperately).
GRAND TOTAL 4,290,977.01
GRAND TOTAL 4,290,977.01
Digitally signed by SUPARNA
PROJECT: PROPOSED CONSTRUCTION OF TAMS BUILDING, MAITHAN
BUILDING NAME : ENTRANCE GATE, GUARD ROOM & TOILET (G)
ABSTRACT OF COST - CIVIL WORKS
DSR-2023 DESCRIPTION DSR-2023 AMOUNT NON DSR AMOUNT
A 2.0 EARTH WORKS 60,562.76 -
B 4.0 CONCRETE WORKS 41,664.46 -
C 5.0 REINFORCED CEMENT CONCRETE WORK 389,481.97 -
D 6.0 BRICK WORK 94,014.32 -
E 8.0 MARBLE & GRANITE WORK 26,272.10 -
F 9.0 WOOD & PVC WORK 23,438.36 -
G 10.0 STEEL WORK 59,099.90 -
K 21.0 ALUMINIUM WORK 76,371.41 -
L 22.0 WATER PROOFING 25,723.84 -
GRAND TOTAL 963,196.92
GRAND TOTAL 963,196.92
Digitally signed by SUPARNA
PROJECT: PROPOSED CONSTRUCTION OF TAMS BUILDING, MAITHAN
GUARD ROOM & TOILET (G) , BOQ - CIVIL WORKS
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
A 2.0 EARTH WORKS
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5
1 2.6 m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
i 2.6.1 All kinds of soils Cum 50.92 177.50 9038.66
Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials.
i 2.26.1 All kinds of soil Cum 6.64 126.80 842.21
Excavating trenches of required width for pipes, cables, etc.
including excavation for sockets, and dressing of sides, ramming of
3 2.10 bottoms, depth upto 1.5m including getting out the excavated soil,
and then returning the soil as required, in layers not exc
a 2.10.1 All kinds of soil.
Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
4 2.25 consolidating each deposited layer by ramming and watering, lead Cum 44.17 196.00 8658.08
up to 50 m and lift upto 1.5 m.
Disposal of excavated excess earth away from the site including
conveyance of materials up to an average lead of 5KM away from
the site, and correspondiong required lift, loading, unloading etc
5 1.1.2 complete as directed by the Engineer-in-charge. (The quantity is net
quantity of capacity of truck after deduction of 20% for
looseness)(considering the maximum disposal location at 5 KM
By mechanical transport including loading, unloading and stacking.
i 1.1.2 (8) (Lead upto 5KM away from the site) Cum 6.75 326.68 2204.48
Supplying and filling in plinth with sand under floors, including
6 2.27 watering, ramming, consolidating and dressing complete. Cum 4.22 2123.75 8967.53
Surface dressing of the ground including removing vegetation and
7 2.28 inequalities not exceeding 15 cm deep and disposal of rubbish, lead
up to 50 m and lift up to 1.5 m.
i 2.28.1 All kinds of soil Sqm 19.43 34.15 663.36
Dry brick on edge flooring in required pattern with bricks of class
designation 7.5 on a bed of 12 mm mud mortar, including filling
joints with Jamuna sand, with common burnt clay non modular
Supplying chemical emulsion in sealed containers including delivery
9 2.34 as specified
i 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Litre 10.47 234.75 2456.70
10 Anti termite treatment
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL
2.35 anti-termite treatment (excluding the cost of chemical emulsion) :
Along external wall where the apron is not provided using chemical
emulsion @ 7.5 litres / sqm of the vertical surface of the
i 2.35.1.1 substructure to a depth of 300mm including excavation channel Metre 19.78 38.90 769.25
along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane
E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @
one litre per hole, 300 mm apart including drilling 12 mm diameter
a) 2.35.3 holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse
sand) to match the existing floor:
i 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm 12.31 310.05 3816.72
TOTAL (Carried Over to Summary of Civil Works) 60562.76 0.00
B 4.0 CONCRETE WORKS
Providing and laying in position cement concrete of specified grade
1 4.1 excluding the cost of centering and shuttering - All work up to plinth
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural
a 4.1.6 sources : 6 graded stone aggregate 40 mm nominal size derived from Cum 0.50 7178.75 3589.38
natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
b 4.1.8 sources : 8 graded stone aggregate 40 mm nominal size derived from Cum 2.82 6812.00 19175.78
natural sources)
Providing and laying cement concrete in retaining walls, return walls,
walls (any thickness) including attached pilasters, columns, piers,
abutments, pillars, posts, struts, buttresses, string or lacing courses,
2 4.2 parapets, coping, bed blocks, anchor blocks, plain window sills,
fillets, sunken floor etc., up to floor five level, excluding the cost of
centering, shuttering and finishing:
1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural
i 4.2.2 sources : 3 graded stone aggregate 20 mm nominal size derived from Cum 0.45 10357.55 4649.25
natural sources).
1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural
ii 4.2.5 sources : 6 graded stone aggregate 20 mm nominal size derived from Cum 0.03 9311.40 244.42
natural sources)
Centering and shuttering including strutting, propping etc. and
removal of form work for :
i 4.3.1 Foundations, footings, bases for columns. Sqm 9.00 391.15 3520.35
Providing and laying damp-proof course 50mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from
natural sources : 4 graded stone aggregate 20mm nominal size
derived from natural sources).
Extra for providing and mixing water proofing material in cement
4 4.12 concrete work in doses by weight of cement as per manufacturer's 2.00 18.15 36.30
Providing & applying a coat of residual petroleum bitumen of grade
of VG-10 of approved quality using 1.7kg per square metre on damp
5 4.13 proof course after cleaning the surface with brushes and finally with Sqm 6.00 146.15 876.90
a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1
cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm
nominal size) over 75mm thick bed of dry brick ballast 40 mm
6 4.17 nominal size, well rammed and consolidated and grouted with fine Sqm 8.81 749.30 6597.59
sand, including necessary excavation, levelling & dressing & finishing
the top smooth.
TOTAL (Carried Over to Summary of Civil Works) 41664.46 0.00
C 5.0 REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and
removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth
and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
d 5.9.4 Shelves (Cast in situ) Sqm 2.49 927.25 2308.85
Lintels, beams, plinth beams, girders, bressumers and cantilevers
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 37.50 961.30 36048.75
g 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 0.00 764.95 0.00
h 5.9.9 Arches, domes, vaults up to 6 m span Sqm 5.00 2154.35 10771.75
Small lintels not exceeding 1.5m clear span, moulding as in cornices,
i 5.9.15 window sills, string courses, bands, copings, bed plates, anchor Sqm 0.39 392.15 152.42
blocks and the like.
j 5.9.16 Edges of slabs and breaks in floors and walls
k 5.9.19 Weather shade, Chajjas, corbels etc., including edges. Sqm 1.22 951.10 1155.59
Extra for additional height in centering, shuttering where ever
required with adequate bracing, propping etc., including cost of de-
l 5.11 shuttering and decentering at all levels, over a height of 3.5 m, for
every additional height of 1 metre or part thereof (Plan area to be
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
Suspended floors, roofs, landing, beams and balconies (Plan area to
Steel reinforcement for R.C.C. work including straightening, cutting,
2 5.22 bending, placing in position and binding all complete upto plinth
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 659.00 107.85 71072.81
Steel reinforcement for R.C.C. work including straightening, cutting,
3 5.22A bending, placing in position and binding all complete above plinth
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 737.63 107.85 79553.36
Providing and laying in position ready mixed or site batched design
mix cement concrete for reinforced cement concrete work; using
coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS: 9103 to
accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding
4 5.33.1 the cost of centering, shuttering, finishing and reinforcement as per
direction of the engineer-in-charge; for the following grades of
concrete. Note: Extra cement up to 10% of the minimum specified
cement content in design mix shall be payable separately. In case the
cement content in design mix is more than 110% of the specified
minimum cement content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra cement.
a) 5.33.1 All works upto plinth level.
Concrete of M25 grade with minimum cement content of 330 kg
b) 5.33.2 All works above plinth level upto floor V level.
Concrete of M25 grade with minimum cement content of 330 kg
Add for using extra cement in the items of design mix over and
above the specified cement content therein.
TOTAL (Carried Over to Summary of Civil Works) 389481.97 0.00
D 6.0 BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in foundation and plinth in:
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 0.47 7132.25 3334.33
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars
2 6.15 at every third course of half brick masonry. Sqm 2.25 104.80 235.80
Brick work with non modular fly ash bricks conforming to IS:12894,
3 6.34 class designation 10 average compressive strength in super structure
above plinth level up to floor V level in :
i 6.34.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 10.30 8452.55 87083.72
Brick edging 7cm wide 11.4 cm deep to plinth protection with
common burnt clay F.P.S. (non modular) bricks of class designation
7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine
Half brick masonry with non modular fly ash bricks of class
5 6.45 designation 10, conformingio IS :12894, in super structure above
plinth and upto floor V level.
i 6.45.2 Cement mortar 1:4 (1 cement : 4 coarse sand) Sqm 2.25 1105.80 2488.05
TOTAL (Carried Over to Summary of Civil Works) 94014.32 0.00
E 8.0 MARBLE & GRANITE WORK
Providing and fixing 18mm thick gang saw cut ( premoulded and
prepolished) machine cut for kitchen platforms, vanity counters,
window sills , facias and similar locations of required size of
approved shade, colour and texture laid over 20mm thick base
1 8.2 cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated
with white cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to edge to give
high gloss finish etc. complete at all levels.
Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black
i 8.2.1.1 Area of slab upto 0.50 sqm Sqm 0.53 3414.80 1792.77
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
ii 8.2.1.2 Area of slab over 0.50 sqm Sqm 2.49 3078.40 7665.22
Extra for fixing marble / granite stone over and above corresponding
basic item, in facia and drops of width upto 150mm with epoxy resin
baesd adhesive including cleaning etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming
to IS: 15622 (thickness to be specified by the manufacturer), of
approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-Charge, in skirting,
3 8.31 risers of steps and dados, over 12 mm thick bed of cement mortar Sqm 11.40 1267.95 14454.63
1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry
@ 3.3kg per sqm, including pointing in white cement mixed with
pigment of matching shade complete.
TOTAL (Carried Over to Summary of Civil Works) 26272.10 0.00
F 9.0 WOOD & PVC WORK
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction
1 9.21 with frame of 1st class hard wood and well matched commercial 3
ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with
necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm
2 9.23 minimum depth on all edges of flush door shutters (over all area of Sqm 3.47 462.35 1602.04
door shutter to be measured).
Providing and fixing wooden moulded beading to door and window
frames with iron screws, plugs and priming coat on unexposed
surface etc. complete :2nd class teak wood.50x12 mm.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to
frame with 10 mm diameter bolts, nuts and wooden plugs and
4 9.53 embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 Each 8.00 228.85 1830.80
cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal
Providing and fixing aluminium sliding door bolts, ISI marked
anodised anodic coating not less than grade AC 10 as per IS : 1868),
5 9.96 transparent or dyed to required colour or shade, with nuts and
screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade, with necessary
screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
7 9.100 transparent or dyed to required colour or shade, with necessary
screws etc. complete :
Providing & Fixing decorative high pressure laminated sheet of plain
/ wood grain in gloss / matt / suede finish with high density
8 9.127 protective surface layer and reverse side of adhesive bonding quality
conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
TOTAL (Carried Over to Summary of Civil Works) 23438.36 0.00
G 10.0 STEEL WORK
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
Providing and fixing pressed steel door frames conforming to IS:
4351, manufactured from commercial mild steel sheet of 1.60 mm
thickness, including hinges, jamb, lock jamb, bead and if required
angle threshold of mild steel angle of section 50x25 mm, or base ties
of 1.60 mm, pressed mild steel welded or rigidly fixed together by
mechanical means,
including M.S. pressed butt hinges 2.5 mm thick with mortar guards,
lock strike-plate and shock absorbers as specified and applying a
coat of approved steel primer after pre-treatment of the surface as
directed by Engineer-in-charge:
10.14.1. Profile B,Fixing with adjustable lugs with split end tail to each jamb
Steel work welded in built up sections/ framed work including
2 10.25 cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required
In stringers, treads, landings etc. of stair cases including use of
a 10.25.1 chequered plate wherever required, all complete. KG 50.00 123.60 6180.00
In gratings, frames, guard bar, ladder, railings, brackets, gates and
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box
for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid
of 1.5 mm thick M.S. sheet with its top surface hacked for proper
bonding, top lid shall be screwed into the cast iron/ M.S. sheet box
3 10.18 by means of 3.3 mm dia round headed screws, one lock at the Each 1.00 220.65 220.65
corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape
as per standard drawing.
Providing and fixing carbon steel galvanised ( minimum coating 5
micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield
strength 480 N/mm2), counter sunk head, comprising of 10 m dia
polyamide PA 6 grade sleeve, including drilling of hole in frame ,
concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories & stainless
steel dash fasteners , stainless steel bolts etc., of required size, on
the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-charge, (for payment
purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.)
TOTAL (Carried Over to Summary of Civil Works) 59099.90 0.00
H 11.0 FLOORING WORK
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate) finished with a floating coat of neat cement
1 11.3 including cement slurry, but excluding the cost of nosing of steps
i 11.3.1 40mm thick with 20mm nominal size stone aggregate. Sqm 5.00 614.20 3071.00
Kota stone slab flooring over 20 mm (average) thick base laid over
and jointed with grey cement slurry mixed with pigment to match
2 11.26 the shade of the slab including rubbing and polishing complete with
base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and
pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3
3 11.27 coarse sand) and jointed with grey cement slurry mixed with sqm 0.30 2354.70 700.52
pigment to match the shade of the slabs, including rubbing and
polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand
Extra for Kota stone/ sand stone in treads of steps and risers using
single length up to 1.05 metre.
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer) of 1st quality
conforming to IS : 15622 of approved make in colours such as White,
Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar
1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @
3.3 kg/sqm including pointing the joints with white cement and
matching pigment etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved brand &
manufacturer, in all colours and shade, laid on 20 mm thick cement
mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement
slurry @3.3 kg/sqm including grouting the joints with white cement
and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only . Laying of tiles will be done with the
notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
a) 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
TOTAL (Carried Over to Summary of Civil Works) 30432.14 0.00
I 12.0 ROOFING
Providing and laying gola 75x75mm in cement concrete M15 grade
1 12.21 including finishing with cement mortar 1:3 (1 cement : 3 fine sand) rmt. 16.18 305.15 4937.33
as per standard design in 75x75 mm deep chase.
Making khurras 45x45 cm with average minimum thickness of 5 cm
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400
micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse
sand) and a coat of neat cement, rounding the edges and making
and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC RAIN
WATER PIPES conforming to IS : 13592 Type A including jointing with
3 12.41 seal ring conforming to IS : 5382 leaving 10 mm gap for thermal
expansion.(i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
a) 12.42.1 Coupler
c) 12.42.6 Shoe (Plain)
Providing and laying brick tiles over mumty roofs, grouted with
cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of
integral water proofing compound by weight of cement, over 12 mm
layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished
neat: With common burnt clay F.P.S. (non modular) brick tiles of
class designation 10.
TOTAL (Carried Over to Summary of Civil Works) 16230.96 0.00
J 13.0 FINISHING WORK
1 13.4 12 mm cement plaster of mix :
18 mm cement plaster in two coats under layer 12 mm thick cement
plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm
thick cement plaster 1:6 (1 cement : 6 fine sand).
Add or deduct for plaster drip course/ groove in or moulding to
3 5.30 R.C.C. projections.plastered surface metre 63.00 78.40 4939.20
4 13.16 6 mm cement plaster of mix :
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
Extra for providing and mixing water proofing material in cement per bag of
5 13.21 plaster work in proportion recommended by the manufacturers. 50KG Cement 19.27 22.10 425.78
Wall painting with premium acrylic emulsion paint of interior grade,
having VOC (Volatile Organic Compound ) content less than 50
6 13.83.2 grams/ litre of approved brand and manufacture, including applying Sqm 50.32 142.80 7186.23
additional coats wherever required to achieve even shade and
colour. Two coats.
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound ) content.
7 13.85.3 With water thinnable cement primer on wall surface having VOC Sqm 50.32 73.95 3721.44
content less than 50 grams/litre
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and
i 13.46.1 including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Sqm 88.76 160.60 14255.02
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
9 13.80 plastered wall surface to prepare the surface even and smooth Sqm 139.08 156.05 21704.18
Finishing with Epoxy paint (two or more coats) at all locations
prepared and applied as per manufacturer's specifications including
10 13.52.1 appropriate priming coat, preparation of surface, etc. complete. On Sqm 12.50 241.75 3021.88
Painting with synthetic enamel paint of approved brand and
11 13.61 manufacture to give an even shade :
i 13.61.1 Two or more coats on new work Sqm 2.51 155.90 391.70
Providing and fixing GI hexagonal chicken wire mesh of size 12mm
x22g at the junction of disimilar surfaces of brick masonry wall and R
C C column by beams and the like including necessary nails for fixing
etc, complete all as per specification and direction of Engineer -in -
charge for all floor at all heights.
TOTAL (Carried Over to Summary of Civil Works) 118262.62 1642.08
K 21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular
sections/appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and
screws or with fixing clips, or with expansion hold fasteners
including necessary filling up of gaps at junctions, at top, bottom and
sides with required PVC/neoprene felt etc. Aluminium sections shall
be smooth, rust free, straight, mitred and jointed echanically
wherever required including cleat angle, Aluminium snap beading
for glazing / paneling, C.P. brass / stainless steel screws, all complete
as per architectural drawings and the directions of Engineer-in-
charge. Glazing and paneling to be paid for separately) :
a) 21.1.1 For fixed portion.
Powder coated aluminium (minimum thickness of powder coating 50
For shutters of doors, windows & ventilators including providing and
fixing hinges/ pivots and making provision for fixing of fittings
b) 21.1.2 wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50
Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket
2 21.3 etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid
in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50
Digitally signed by SUPARNA
Sl. DSR- DSR-2023 DSR-2023
DESCRIPTION UNIT QTY. NDSR RATE NDSR Amount
No. 2023 RATE Amount
Filling the gap in between aluminium frame and adjacent
RCC/Brickwork/ Stone Work by providing weather silicon sealant
3 21.8 over backer rod of approved quality as per architectural drawings
and direction of Engineer-in-charge
i 21.8.1 Upto 5mm depth and 5mm width metre 8.40 96.75 812.70
Providing and fixing anodised aluminium grill (anodised transparent
or dyed to required shade according to IS: 1868 with minimum
anodic coating of grade AC 15) of approved design/pattern, with
approved standard section and fixed to the existing window frame
with C.P. brass/ stainless steel screws @ 200 mm centre to centre,
4 21.17 including cutting the grill to proper opening size for fixing and kg 84.00 638.35 53621.40
operation of handles and fixing approved anodised aluminium
standard section around the opening, all complete as per
requirement and direction of Engineer-in-charge. (Only weight of
grill to be measured for payment).
TOTAL (Carried Over to Summary of Civil Works) 76371.41 0.00
L 22.0 WATER PROOFING
Providing & laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: a)
Applying a slurry coat of neat cement using 2.75kg/sqm of cement
admixed with water proofing compound confirming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including
adjoining walls upto 300mm height including cleaning the surface
1 22.7 before treatment. b) Laying brick bats with mortar using broken
bricks/brick bats 25mm to 115mm size with 50% of cement mortar
1:5 (1 cement : 5 coarse sand ) admixed with water proofing
compound confirming to IS : 2645 and approved by Engineer-in-
charge over 20 mm thick layer of cement of 1:5 ( 1 cement : 5 coarse
sand ) admixed with water proofing compound confirming to IS :
2645 and approved by Engineer-in-charge to required slope and
treating similarly the
adjoining walls upto 300mm height including rounding of junctions
of walls and slabs. c) After two days of proper curing applying a
second coat of cement slurry using 2.75kg/sqm of cement admixed
with water proofing compound confirming to IS : 2645 and approved
by Engineer-in-charge. d) Finishing the surface with 20 mm thick
jointless cement mortar 1:4 (1 cement : 4 coarse sand ) admixed
with water proofing compound confirming to IS : 2645 and approved
by Engineer-in-charge including laying glass fibre cloth of approved
quality in top layer and finally finishing the surface with trowel with
neat cement slurry and making pattern of 300x300 mm square 3mm
deep. e) The whole terrace so finished shall be flooded with water
for a minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and specified
by the Engineer-in-charge:
With average thickness of 120mm and minimum thickness at khurra
TOTAL (Carried Over to Summary of Civil Works) 25723.84 0.00
ALL SUB-HEAD TOTAL 961554.84 1642.08
GRAND TOTAL 963196.92
GRAND TOTAL 963196.92
Digitally signed by SUPARNA
Abstract. Boundary Wall
PROJECT:- PROPOSED CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC
MAITHON SUBSTATION.
NEW CONSTRUCTION AND RENNOVATION OF BOUNDARY WALL
ABSTRACT OF COST
Si. No. Particulars Amount
1 Total Civil works for Rennovation of Existing Boundary Wall ₹ 805,039.00
2 Total Civil works for Construction of Boundary Wall With Concertina Wire ₹ 1,259,464.00
3 Total Civil works for Construction of Boundary Wall With Grill ₹ 1,020,513.00
Gross Total ₹ 3,085,016.00
Grand Total = ₹ 3,085,016.00
Grand Total = ₹ 3,085,016.00
Renno_Boundary_Sum.
PROJECT:- PROPOSED CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON
RENNOVATION OF BOUNDARY WALL
ABSTRACT OF COST - CIVIL WORKS
Sl. No. DSR-2023 DESCRIPTION
A 5.0 REINFORCED CEMENT CONCRETE WORK 254,110.58
B 6.0 BRICK WORK 61,544.10
C 13.0 FINISHING 255,422.10
D 14.0 REPAIRS TO BUILDING 112,120.00
E 15.0 DISMANTLING & DEMOLISHING 53,070.77
F 16.0 ROAD WORK 68,771.40
GRAND TOTAL 805,039.00
GRAND TOTAL 805,039.00
Bill Of Quantity
CONSTRUCTION OF TWO STOREYED SWITCH YARD AND CONTRIOL ROOM TAMS BUILDING
AT DVC MAITHON SUBSTATION
RENNOVATION OF BOUNDARY WALL
Based on Schedule Rate : DSR -2023
Si. No. Item of Work Unit Quantity Rate Amount
A 5.0 REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and removal
a) 5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts Sqm 25.50 961.30 24,513.15
Steel reinforcement for R.C.C. work including straightening, cutting,
2 5.22A bending, placing in position and binding all complete above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 1157.91 107.85 124,880.19
Providing and laying in position ready mixed or site batched design mix
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting
of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing,
3 5.33.1 carriage for all leads; but excluding the cost of centering, shuttering,
finishing and reinforcement as per direction of the engineer-in-charge;
for the following grades of concrete. Note: Extra cement up to 10% of
the minimum specified cement content in design mix shall be payable
separately. In case the cement content in design mix is more than 110%
of the specified minimum cement content, the contractor shall have
discretion to either re-design the mix or bear the cost of extra cement.
a) 5.33.1 All works upto plinth level.
Concrete of M25 grade with minimum cement content of 330 kg /cum
Add for using extra cement in the items of design mix over and above
(Derived) the specified cement content therein.
5.35 Note:- Excess/less cement over the specified cement content used is
payable / recoverable separately.
TOTAL (Carried Over to Summary of Civil Works) 254,110.58
B 6.0 Brick Work
Brick work with non modular fly ash bricks conforming to IS:12894,
6.34 class designation 10average compressive strength in super structure
above plinth level up to floor V level in :
6.34.2 Cement mortar 1:6 (1 cement: 6 coarse sand ) cum 12.77 4819.90 61,544.10
TOTAL (Carried Over to Summary of Civil Works) 61,544.10
D 13.0 Finishing
1 Cement plaster in course sand
13.4 12 mm cement plaster of mix:
2 13.6 20 mm cement plaster of mix
3 13.16 6 mm cement plaster of mix :
4 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
i 13.46.1 New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and Sqm 1050.24 160.60 168,669.15
including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Removing white or colour wash by scrapping and sand papering and
5 13.88 preparing the surface smooth including necessary repairs to scratches Sqm 878.40 19.75 17,348.40
TOTAL (Carried Over to Summary of Civil Works) 255,422.10
E 14.0 REPAIRS TO BUILDING
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5
sq.meters and under, including cutting the patch in proper shape,
1 14.1 raking out joints and preparing and plastering the surface of the walls
complete, including disposal of rubbish to the dumping ground, all
complete as per direction of Engineer-in-Charge.
Digitally signed by
Bill Of Quantity
Si. No. Item of Work Unit Quantity Rate Amount
14.1.2 With cement mortar 1:4 (1cement: 4 coarse sand) Sqm 200.00 560.60 112,120.00
TOTAL (Carried Over to Summary of Civil Works) 112,120.00
F 15.0 Dismantling & Demolishing
Demolishing R.C.C. work manually/ by mechanical means including
1 15.3 stacking of steel bars and disposal of unserviceable material within 50 Cum 13.27 3551.25 47,137.52
metres lead as per direction of Engineer - in- charge.
Extra for scrapping, cleaning and straightening reinforcement from
R.C.C. or R.B. work.
TOTAL (Carried Over to Summary of Civil Works) 53,070.77
G 16.0 Road Work
Providing and fixing concertina coil fencing with punched tape
concertina coil 600 mm dia 10 metre openable length ( total length 90
m), having 50 nos rounds per 6 metre length, upto 3 m height of wall
with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with
9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples
1 16.53 and G.I. clips to retain horizontal, including necessary bolts or G.I. Mtr. 183.00 375.8 68,771.40
barbed wire tied to angle iron, all complete as per direction of Engineer-
in-charge, with reinforced barbed tape (R.B.T.) / Spring core (2.5mm
thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52
mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks
shall be paid separately)
TOTAL (Carried Over to Summary of Civil Works) 68,771.40
Grand Total = 805,038.95
Grand Total = 805,038.95
Digitally signed by
CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON SUBSTATION.
CONSTRUCTION OF BOUNDARY WALL BASED ON DSR 2023
SL.NO ITEM NO. DESCRIPTIOM OF ITEM NOS QUANTITY UNIT RATE AMOUNT
Earth work in excavation by mechanical means
(Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10
1 2.6.1 sqm on plan) including getting out and disposal of 32.781 Cum 177.50 5818.63
excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
All Kinds of Soil
Supplying and filling in plinth with sand under floors,
2 2.27 including watering, ramming, consolidating and dressing 3.147 Cum 2,123.75 6683.44
Providing and laying in position cement concrete of
3 4.1 specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from
4.1.8 natural sources : 8 graded stone aggregate 40 mm 3.147 Cum 6,812.00 21437.36
nominal size derived from natural sources)
Providing and laying in position specified grade of
4 5.1 reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All
work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived
5.1.2 from natural sources : 3 graded stone aggregate 20 mm 7.265 Cum 9,045.75 65712.85
nominal size derived from natural sources)
Reinforced cement concrete work in walls (any
thickness), includint attached pilasters, buttresses,
plinth and string courses, fillets, columns, pillars, piers,
5 5.2 abutments, posts and struts etc. above plinth level up to
floor five level, excluding cost of cente.ing, shuttering,
finishing and reinforcement :
1:1.5:3 (l cement: 1.5 coarse sand(zone lll) derived from
5.2.2 natu'ral sources 3 gJaded stone aggregate 20 mm 1.856 Cum 10,852.95 20145.79
nominal size derived from natural sources)
Steel reinforcement for R.C.c. work including
6 5.22A straightening, cutting, bending, placing in position and
binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or
Filling available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not
7 2.25 exceeding 20cm in depth, consolidating each deposited 21.116 Cum 196.00 4138.79
layer by ramming and watering, lead up to 50 m and lift
Brick work with common burnt clay F.P.S. (non modular)
8 6.1 bricks of class designation 7.5 in foundation and plinth
6.1.2 Cement mortar 1:6 (1 cement i 6 coarse sand) 0.938 Cum 7,132.25 6686.48
Brick work with non modular fly ash bricks conforminS
9 6.34 to ls:12894, class designation 10 average compressive
streneth in super structure above plinth level up to floor
6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) 13.869 Cum 8,752.55 121389.12
Digitally signed by SUPARNA
10 13.1 12 mm cement plaster of mix :
Finishing walls with Acrylic Smooth exterior paint
of required shade :
New work (Two or more coat applied @ 1.67 ltr/
10 sqm over and including priming coat of exterior
primer applied @ 2.20 kg/ 10 sqm)
Qty Same as Plaster 158.400 Sqm 160.60 25439.04
Providing and frxing concertina coil fencing with
punched tape concertina coil 600 mm dia 10 metre
openable length (total length 90 m), having 50 nos
rounds per 6 metre length, upto 3 m height of wall with
exissting angle iron'Y' shaped placed 2.4m or 3.OO m
apart and with t horizontal R.B.T. reinforced barbed
wire, stud tied with G.l. staples and G.l. clips to retain
horizontal, includin8 necessary bolts or G.l. barbed wire
tied to antle iron, all complete as per direction of
Engineer-in-char8e, with reinforced barbed tape (R.8.T.)
/ SprinS core (2.5mm thick) wire ol hiSh tensile strength
of 165 k&/ sq.mm with tape (0.52 mm thick) and weight
43.478 8m/ metre (.o!t of M.5. angle, C.C. blocks Shall
be paid separatelv)
centering and shuttering including strutting, propping
5.9.1 etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass
Centering and shuttering including strutting, propping
etc. and removal of form for: Sqm 736.40 14801.64
Lintels, beams, plinth beams, girders, bressumers and
Centering and shuttering including strutting, propping
etc. and removal of form for : Sqm 961.30 28550.61
Columns, Pillars, Piers, Abutments, Posts and Struts
Rate For 30 Mtr Boundry Wall = 419821.29
Rate For 1 Mtr Boundry Wall = 11661.70
Rate For 108.0 Mtr Boundry Wall = 1259463.87
Digitally signed by SUPARNA
CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON SUBSTATION.
CONSTRUCTION OF BOUNDARY WALL BASED ON DSR 2023
SL.NO ITEM NO. DESCRIPTIOM OF ITEM NOS QUANTITY UNIT RATE AMOUNT
Earth work in excavation by mechanical means
(Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10
1 2.6.1 sqm on plan) including getting out and disposal of 32.781 Cum 177.50 5818.63
excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
All Kinds of Soil
Supplying and filling in plinth with sand under floors,
2 2.27 including watering, ramming, consolidating and dressing 3.147 Cum 2,123.75 6683.44
Providing and laying in position cement concrete of
3 4.1 specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from
4.1.8 natural sources : 8 graded stone aggregate 40 mm 3.147 Cum 6,812.00 21437.36
nominal size derived from natural sources)
Providing and laying in position specified grade of
4 5.1 reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All
work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived
5.1.2 from natural sources : 3 graded stone aggregate 20 mm 7.265 Cum 9,045.75 65712.85
nominal size derived from natural sources)
Reinforced cement concrete work in walls (any
thickness), includint attached pilasters, buttresses,
plinth and string courses, fillets, columns, pillars, piers,
5 5.2 abutments, posts and struts etc. above plinth level up to
floor five level, excluding cost of cente.ing, shuttering,
finishing and reinforcement :
1:1.5:3 (l cement: 1.5 coarse sand(zone lll) derived from
5.2.2 natu'ral sources 3 gJaded stone aggregate 20 mm 2.269 Cum 10,852.95 24622.63
nominal size derived from natural sources)
Steel reinforcement for R.C.c. work including
6 5.22A straightening, cutting, bending, placing in position and
binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or
Filling available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not
7 2.25 exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift
TOTAL EARTH FILLING 21.116 Cum 196.00 4138.79
Brick work with common burnt clay F.P.S. (non modular)
8 6.1 bricks of class designation 7.5 in foundation and plinth
6.1.2 Cement mortar 1:6 (1 cement i 6 coarse sand) 0.938 Cum 7,132.25 6686.48
Brick work with non modular fly ash bricks conforminS
9 6.34 to ls:12894, class designation 10 average compressive
streneth in super structure above plinth level up to floor
6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand)
10 13.1 12 mm cement plaster of mix :
Digitally signed by SUPARNA
Finishing walls with Acrylic Smooth exterior paint
of required shade :
New work (Two or more coat applied @ 1.67 ltr/
10 sqm over and including priming coat of exterior
primer applied @ 2.20 kg/ 10 sqm)
Qty Same as Plaster 108.600 Sqm 160.60 17441.16
Steel work welded in built up sections/ framed work,
12 10.25 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer using
structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works
centering and shuttering including strutting, propping
13 5.9.1 etc. and removal of form for : 15.840 Sqm 392.15 6211.66
Foundations, footings, bases of columns, etc. for mass
Centering and shuttering including strutting, propping
etc. and removal of form for: Sqm 736.40 14801.64
Lintels, beams, plinth beams, girders, bressumers and
Centering and shuttering including strutting, propping
etc. and removal of form for : Sqm 961.30 34895.19
Columns, Pillars, Piers, Abutments, Posts and Struts
Rate For 30 Mtr Boundry Wall = 448029.88
Rate For 1 Mtr Boundry Wall = 12445.27
Rate For 82.0 Mtr Boundry Wall = 1020512.51
Digitally signed by SUPARNA
PROJECT: PROPOSED CONSTRUCTION OF TWO STOREYED AT DVC MAITHON SUBSTATION.
UGT, SUMMARY - CIVIL WORKS
Sl. No. DSR-2023 DESCRIPTION DSR AMOUNT Non SOR AMOUNT
A 2.0 EARTH WORKS 408,679.15 -
B 4.0 CONCRETE WORKS 62,890.33 -
C 5.0 REINFORCED CEMENT CONCRETE WORK 2,308,899.23 -
D 6.0 BLOCK WORK 15,944.86 -
E 10.0 STEEL WORK 92,035.55 -
G 13.0 FINISHING 126,154.49 -
I 22.0 WATER PROOFING 150,059.86 -
GRAND TOTAL 3,451,424.14
GRAND TOTAL 3,451,424.14
CONSTRUCTION OF TWO STOREYED TAMS BUILDING AT DVC MAITHON SUBSTATION.
UGT- BOQ - CIVIL WORKS
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. SOR Amount NSOR RATE NSOR Amount
A 2.0 EARTH WORKS
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
1 2.6 getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-in-charge.
i 2.6.1 All kinds of soil. Cum 520.63 177.50 92412.43
Earth work in excavation by mechanical means (Hydraulic
excavator)/ manual means over areas (exceeding 30 cm in
depth, 1.5 m in width as well as 10 sqm on plan) including
2 2.7 getting out and disposal of excavated earth lead upto 50 m and
lift upto 1.5 m, as directed by Engineer-incharge.
i 2.7.1 Ordinary rock Cum 70.50 498.90 35172.45
Extra for every additional lift of 1.5 m or part thereof in.
a) 2.26.1 All kinds of soils
4 2.24 Extra rates for quantities of works, executed :
In or under water and/or liquid mud, including pumping out
water as required.(Note for item no. 2.24:- The extra
percentage rate is applicable in respect of each item but
limited to quantities of work executed in these difficult
conditions. The unit, namely, metre depth, to be considered for
payment, shall be the depth measured from the sub soil water metre
i 2.24.1 level upto the centre of gravity of the quantity executed in depth/Cu 77.41 35.50 2748.22
difficult conditions. The depth shall be reckoned correct to 0.1 m
metre. 0.05 metre or more shall be taken as 0.1 metre and less
than 0.05 metre ignored.)
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
5 2.25 depth, consolidating each deposited layer by ramming and Cum. 274.79 196.00 53859.48
watering, lead up to 50 m and lift upto 1.5 m.
Disposal of excavated excess earth/rock away from the site
including conveyance of materials up to an average lead of
5KM away from the site, and correspondiong required lift,
loading, unloading etc complete as directed by the Engineer-in-
6 1.1.2 charge. (The quantity is net quantity of capacity of truck after
deduction of 20% for looseness)(considering the maximum
disposal location at 5 KM distance)
Earth By mechanical transport including loading, unloading and
i 1.1.2 stacking. (Lead upto 5KM away from the site) Cum 245.84 326.68 80311.06
Ordinary Rock By mechanical transport including loading,
ii 1.1.4 unloading and stacking. (Lead upto 5KM away from the site) Cum 70.50 522.70 36850.35
Supplying and filling in plinth with sand under floors, including
7 2.27 watering, ramming, consolidating and dressing complete. Cum 5.10 2123.75 10831.13
TOTAL (Carried Over to Summary of Civil Works) 408679.15 0.00
B 4.0 CONCRETE WORKS
Providing and laying in position cement concrete of specified
1 4.1 grade excluding the cost of centering and shuttering - All work
up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
a 4.1.8 sources : 8 graded stone aggregate 40 mm nominal size derived Cum. 8.35 6,812.00 56860.92
from natural sources)
Sl. No. DSR-2023 DESCRIPTION UNIT QTY. SOR Amount NSOR RATE NSOR Amount
Extra for laying concrete in or under water and/or liquid mud
including cum per cost of pumping or bailing out water and
removing slush etc.complete.Note for item No. 4.15 :- The
quantity will be calculated by multiplying the depth measured
from the sub-soil water level up to centre of gravity
of concrete under sub-soil water level with quantity of meter
concrete in cum executed under sub-soil water. The depth of depth
centre of gravity shall be reckoned correct to 0.1m. 0.05m or
more shall be taken as 0.1m and less than 0.05m ignored.
Centering and shuttering including strutting, propping etc. and
3 4.3.1 removal of form work for : Foundations, footings, bases for Cum 5.15 392.15 2018.79
TOTAL (Carried Over to Summary of Civil Works) 62890.33 0.00
C 5.0 REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and
1 5.9 removal of form for :
Foundations, footings, bases of columns, etc. for mass
Walls (any thickness) including attached pilasters, butteresses,
b 5.9.2 plinth and string courses etc. Sqm 377.04 842.50 317652.83
Suspended floors, roofs, landings, balconies and access
Lintels, beams, plinth beams, girders, bressumers and
d 5.9.5 cantilevers Sqm 0.00 736.40 0.00
e 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 0.00 961.30 0.00
f 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sq.Mt. 0.00 764.95 0.00
g 5.9.16 Edges of slabs and breaks in floors and walls
Extra for additional height in centering, shuttering where ever
required with adequate bracing, propping etc., including cost
of de-shuttering and decentering at all levels, over a height of
2 5.11 3.5 m, for every additional height of 1 metre or part thereof
(Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan
i 5.11.1 area to be measured) Sqm 27.75 384.30 10664.33
Steel reinforcement for R.C.C. work including straightening,
3 5.22 cutting, bending, placing in position and binding all complete
upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 8236.21 107.85 888274.82
Steel reinforcement for R.C.C. work including straightening,
4 5.22A cutting, bending, placing in position and binding all complete
above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 0.00 107.85 0.00
Extra for laying reinforced cement concrete in or under water
and/ or liquid mud, including cost of pumping or bailing out
water and removing slush etc., complete. Note For Item No.
5.31:- The quantity will be calculated by multiplying the depth
measured from the subsoil water level up to the centre of
gravity of the R.C.C. under subsoil water with the quantity of
R.C.C. in cubic metre executed under subsoil water. The depth
of centre of gravity shall be reckoned correct to 0.1 m. 0.05 m
or more shall be taken as 0.1 m and less than 0.05 m ignored.
No extra payment shall be made for placing reinforcement or
centering & shuttering under sub - soil water conditions.
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT DVC Maithon.pdf
Tender Document
BOQ DVC Maithon.pdf
Tender Document
Integrity Pact.pdf
Tender Document
GCC 2022 with Ammendments.pdf
Tender Document
SCC.pdf
Tender Document
Technical Circulars.pdf
Tender Document
TENDER DRAWING.pdf
Tender Document
List of Makes.pdf
Tender Document
corrigendum-4299-Tamspricebid.pdf
pdf • 0.40 MB
corrigendum-4232-Corrigendum No DVC TAMS.pdf
pdf • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .