Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | L1 | Accepted-AOC Became L1 and technically eligible. | |
| 2 | L2₹1.8 L+₹9,410.50 (5.64%)Rejected-Finance AT REMUAN PO HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹2.7 L+₹1.0 L (62.1%)Rejected-Finance AT ITI CHHAK PO TALCHER DIST ANGUL PIN 759100 | ANUGUL | ODISHA | 759100 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹2.7 L+₹1.1 L (63.6%)Rejected-Finance AT PO TALCHER TOWN PS TALCHER DIST ANGUL ODISHA | L4 | Rejected-Finance Being L4 |
Tender Value
₹2.5 L
EMD Value
₹3,200
Closing Date
27 Mar 2023, 6:00 pmClosed
Staff Officer EnM, MCL Bharatpur Area
Sri Saikat Chaudhary, mob no. 94384 93763, Address Staff Officer EnM, MCL Bharatpur Area Office, N.S.Nagar, Talcher, Angul dist. 759148
Complete Internal Wiring of GM Office canteen of Bharatpur Area.
2023_MCL_275280_1
MCL/BA/EnM/e-Tender/222354 dtd. 15.03.2023
Open Tender
Miscellaneous Works
Item Rate
30 days
GM Unit, Bharatpur area
Refer Tender Docs
4 documents required · 4 mandatory
₹3,200
Yes
8 May 2023
15 Mar 2023
29 Mar 2023
16 Mar 2023
27 Mar 2023
16 Mar 2023
15 Mar 2023 - 20 Mar 2023
Amount
Providing of 63 A RCCB 4 pole
Providing of 20 w LED Tube light fitting complete
Providing of 100 A TPN Main Switch
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ sub main wiring along with earth wire with the 2x1.5 sq mm + 1x1.5 sq mm FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required
Wiring for circuit/ sub main wiring along with earth wire with the 2x2.5 sq mm + 1 x 2.5 sq mm FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required
Wiring for circuit/ sub main wiring along with earth wire with the 2x4 sq mm + 1 x 4 sq mm FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required
Wiring for circuit/ submain wiring alongwith earth wire with the 2x6 sq mm + 1x 6 sq mm FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. As required. (For light plugs to be used in non residential buildings).
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200 mm X 250 mm X 100 mm deep
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 amp switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 amp switch socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door)
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
Total impact of GST for the purpose of CTC
SWASTIK ELECTRICAL
M/s Santoshi Maa Industries
DILIP KUMAR ROUT
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .