Garrison Engineer Air Force
Garrison Engineer Air Force
COMPREHENSIVE MAINT/REPAIRS TO LIFT AND FIRE ALARM SERVICES WITH ALLIED WORKS IN CERTAIN TECH BLDGS AT AFS THANJAVUR.
2024_MES_638309_1
8104/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Thanjavur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Air Force
₹20,000
18 Mar 2024
19 Jan 2024
17 Feb 2024
19 Jan 2024
16 Feb 2024
3 Feb 2024
Amount
Supply and fixing battery 12 Volts, 7 AH SMF type to existing lift 8-10 persons capacity complete including taking down the unserviceable item all as specified and directed.
Supply and fixing battery 12 Volts, 18 AH SMF type to existing lift 8-10 persons capacity complete including taking down the unserviceable item all as specified and directed.
Supply and fixing cabin light 18 watt 230 volts to existing lift 8-10 persons complete including taking down the unserviceable item all as specified and directed.
Comphrensive maintenance and repairs including attending the break down complaints in the following locations of electric fire smoke alarm system, electrically operated with 8 to 10 zone micro processor based fire alarm panel with LCD display zone, short, open indication all as specified and directed. Note :- The rate quoted by the bidders shall include the following :- (i) Replacement of any electrical and electronic parts like PCB, battery charger, integrated circuits, diodes, capacitors transformer, LED indicators, open / short circuit LEDs, relays etc. (ii) Removing of short circuit / open circuit / earth faults for individual fire alarm panel. (iii) For testing only through authorised service engineer/dealers. (iv) The duration of the test is once in every month througout the currency of contract. (v) Periodical test report to be submitted through authorised service engineer/dealers for every month (vi) Report of monthly inspection maintenance carried out by the bidder to be submitted on every inspection / maintenance and after rectification of any breakdown. (vi) The bidder is lailable for conducting inspection/ maintenance/repair on call basis if required other than normal monthly inspection. On call contractor is required to attend the complaint within 24 hrs. If not attended the complaint within 24 hrs the bidder is liable to pay a penality Rs.1500/- per day.
(vii) Cleaning of every fire/smoke detectors every month. (viii) Replacement of major spare parts as given in item here-in-after will be measured and paid separetely.
SRE tech building
SRE adm building
Signal complex/AF Net
Computer Centre (Addressable type)
FMS (Addressable type)
Sqn Hanger Annex - I & II (Addressable type)
Tech Hanger Annex - I & II (Addressable type)
Supply and fixing existing fire smoke alaram system battery 12V 7 AH SMF type including taking down of unserviceable item. Make : Exide
M&L for sub main wiring with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FR) of working voltage 1100 volts grade with stranded copper conductor including one run of 1.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. Make:- Plaza / Havells / Polycab / FINOLEX
M & L Fire detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence as per IS:11360 including taking out old complete all as specified and as directed.
M & L Fire detectors complying with and type certified to EN - 45 Conventional type multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence as per IS:11360 including taking out old complete all as specified and as directed.
Supply and fix in replacement Conventional type manual call point resettable type complete all as specified and as directed.
Supply and fix in replacement Addressable manual call point resettable type complete all as specified and as directed.
Supply and fix in replacement Addressable type sounder complete all as specified and as directed.
Supply and fix in replacement 10 watt wall mounted Conventional type speaker complete all as specified and as directed.
Supply and fixing switching mode power supply board 230 volts input 24 volts output 60 watts 12 amps complete including taking down of unserviceable item all as specified and directed.
SUPER COOL
M/S. SRI RAMANUJA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .