Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.9 L+₹2.3 L (5.97%)Rejected-Finance INDUSTRIAL ESTATE DOLLYGUNJ PORT BLAIR 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹41.7 L+₹3.0 L (7.88%)Rejected-Finance NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹41.7 L+₹3.0 L (7.89%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹42.2 L+₹3.6 L (9.22%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Aug 2022, 6:00 pmClosed
GE Minniebay
Junglighat PO Port Blair
ADDITION ALTERNATION TO P-24 AND PROVN OF STORAGE SHED AT INS UTKROSH UNDER GE MINNIEBAY, PORT BLAIR
2022_MES_542987_1
8168/E8
Open Tender
Civil Works
Item Rate
180 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹70,000
Yes
17 Sept 2022
4 Aug 2022
31 Aug 2022
4 Aug 2022
29 Aug 2022
22 Aug 2022
Amount
Taking down cement plaster from block masonry wall surface in any description complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store/hand over to the contractor on sch of credit and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Material and Labour for external rendering 5mm thick in cement mortar 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in cement mortar 1:6 over block masonry or concrete surfaces finished even and fair complete all as specified and directed by Engr-in-Charge. Note : Water Proofing Compound shall be measured and paid separately as 'Supply only'
Supply only water proofing compound conforming to IS-2645 1975 complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-Charge
Dismantling Wall and ceiling boards (fibre,pulp, insulation,etc.) including grids complete all as specified and as directed by Engr-in-Charge
Dismantling plain or corrugated steel sheeting of any gauge and thickness including nainital or similar pattern roof coverings including ridges complete all as specified and as directed by Engr-in-Charge
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified and as directed by Engr-in-Charge
S&F 0.50mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge
Dismantling wrought iron or mild steelwork of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge.
M&L rendering 10mm thick in CM (1:6) on block masonry finished even & smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed by Engr-in-Charge
M& L for preparation newly plastered wall surfaces and applying two coats of acrylic emulsion based premium quality matt finish exterior antifungal paint over a coat of alkali resistant primer all as per manufacturer's instructions complete all as specified and as directed by Engr-in-Charge
M & L for coloured chequered cement concrete tiles 300 x 300 x 25 mm thick, set and jointed neat cement slurry and pointed with coloured or grey cement match with pigment, over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc. complete all as specified and as directed by Engr-in-Charge
M & L for non skid coloured ceramic tiles of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
M & L for non skid coloured ceramic tiles of size exceeding 0.11 Sqm and not exceeding 0.18 Sqm, 7 mm to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge
All as per item No 16.00 above but on vertical surfaces over 10mm thick backing coat in cement mortar 1:3 in dado/skirting complete all as specified and as directed by Engr-in-Charge
M & L for glazed coloured ceramic tiles of size 450X 300X 7 to 8mm thick as in vertical surfaces such as skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed by Engr-in-Charge.
M&L for 100mm thick plain cement concrete 1:4:8 type D2 (nominal mix) using 40mm graded stone aggregate for paving, sub base path etc including necessary form work complete all as specified and as directed by Engr-in-Charge
M&L for 100mm thick plain cement concrete 1:2:4 type B2 (nominal mix) using 40mm graded stone aggregate for paving, sub base path including necessary form work complete all as specified and as directed by Engr-in-Charge
M& L for machine cut kota stone slab Ist quality 20 to 25mm thick over 20mm thick cement screed bed or bedding layer in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in-Charge
M&L for machine cut kota stone slab of thickness 20 to 25mm laid over 10mm thick backing coat in cement mortar 1:3 as in riser of steps, skirting, dado and pillar including ribbing and polishing and making sharpless complete all as specified and as directed by Engr-in-Charge
S&F aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/RM, main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc including 'E' board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid including preparation of new surface and applying two coats of oil bound distemper over a coat of primer all as specified and directed by Engr-in-Charge.
All as per item No 23 above but in repairs complete all as specified and as directed by Engr-in-Charge
S & F in Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge. Note:- (i) Weight of various aluminium sections and handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. (ii) Glass panels, prelaminated particle boards, glass & aluminium wire cloth as required shall be measured and paid separately in relevant item of this schedule as supply only).
All as per item No 25.00 above but in repairs complete all as specified and as directed by Engr-in-Charge
Supply only 5mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Supply only 12 mm thick prelaminated particle board, exterior grade prelaminated one side with decorative choice lamination & other side balancing white lamination complete all as specified and as directed by Engr-in-Charge
Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed by Engr-in-Charge
S & F Aluminium flat iron work in, wind ties screwed as directed, including all necessary drilling, bolting or riveting etc and similar work complete all as specified and as directed by Engr-in-Charge
All as per item No 30.00 but in repairs complete all as specified and as directed by Engr-in-Charge
M&L for mild steel rolled sections as in cross beams, hip and jack rafters, vertical posts, purlins where connected to common rafters fixed with angle cleats or similar work including welding and all necessary works complete all as specified Note : The rates are inclusive of Scaffoldings as required
M&L for Plates (Plain or Chequered) channels, square or notched (Ordinary and counter sunk) forming holes, without any attachment of Fe 290 (Gde E-165) completely all as specified and as directed by Engineer in Charge.
M&L for preparing new or previously untreated steel surfaces of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engr-in-Charge
S&F in repairs Vitreous China Wash down water closet pan semi pedestal pattern (Anglo-Indian type, EWC) white in colour with and including plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device including connection to outgoing pipe and flushing pipe complete all as specified and as directed by Engr-in-Charge
S & F in repairs Vitreous china ware wash hand basin, white, flat back of size 550 mm X 400 mm including 32mm brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI brackets, cutting for and pinning in ends of brackets or erecting strand, etc including PVC connections and waster pipe as required complete all as specified and as directed by Engr-in-Charge
S&F in repairs 10 liter capacity PVC low level valve less symphonic action type flushing cistern, white, with inlet, ball valve, float and handle including brackets, and 32mm PVC bend complete all as specified and as directed by Engr-in-Charge
S&F in repair CP towel rail 20 mm dia, 60 cm long fixed with CP screws and wood cleats / rowel plug in wall complete all as specified and as directed by Engr-in-Charge
S & F in repairs pillar taps, cast copper alloy, Chromium Plated, Fancy Type heavy duty, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge
S & F in repairs bib taps cast copper alloy heavy duty, 15 mm dia, chromium plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and as directed by Engr-in-Charge
S & F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed complete all as specified and as directed by Engr-in-Charge
S & F in repairs two way bib taps, cast copper alloy, 15 mm dia, chromium plated, fancy type screwed down for iron pipe and fixed etc complete all as specified and as directed by Engr-in-Charge
S&F in repairs chromium plated health faucet with 1000mm PVC pipe for 15 mm bore with fittings complete all as specified and directed.
S & F in repairs 32/40mm dia PVC flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink complete all as specified and directed..
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long of approved quality complete all as specified and as directed by Engr-in-Charge
S&F in repairs 100 mm dia CP grating with/without hole including joints with solvent cement complete all as specified and directed.
M&L for preparation of old wall surfaces and applying one coat of acrylic emulsion weather coat premium quality antifungal exterior emulsion complete all as specified and as directed by Engr-in-Charge
M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed by Engr-in-Charge
S&F in repairs 20mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed to walls, ceilings or in floors etc complete all as specified and as directed by Engr-in-Charge
S&F in repairs 25mm bore unplasticised PVC pipes of pressure rating 10 Kgf/Sqcm fixed to walls, ceilings or in floors etc complete all as specified and as directed by Engr-in-Charge
Excavation in post holes ( or similar holes) in hard/ dense soil ,each not exceeding 0.5 Cum , getting out returning , filling in and ramming earth or broken rubble mixed with earth around , in layers not exceeding 25 Cm, watering and removing surplus soil to a distance not exceeding 50M and making good surface complete all as specified and as directed by Engr-in-Charge
M&L for plain cement concrete 1:2:4 type C2 (nominal mix) using 40mm graded aggregate as in foudation filling under post hole etc complete all as specified and as directed by Engr-in-Charge
M&L for surface dressing in hard & dense soil not exc 15cm deep complete all as specified and as directed by Engr-in-Charge
M&L for hardcore of gauge exceeding 63mm but not exceeding 100mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rolled/rammed to true surface complete all as specified and as directed by Engr-in-Charge
M &L for 75mm thick plain cement concrete1:4:8 type D-2 (nominal mix) using 40mm graded stone aggregate ,surface finished even and smooth without using extra cement including form work etc complete all as specified and as directed by Engr-in-Charge
M&L for 40mm thick plain cement concrete1:2:4 type B-1 (nominal mix) using 20mm graded stone aggregate, surface finished even and smooth without using extra cement including form work complete all as specified and as directed by Engr-in-Charge
S&F glass dividing strips 3mm thick, 38mm width complete all as specified and as directed by Engr-in-Charge
M&L for precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed.
M&L for steel work in tubular trusses including special shaped washers etc complete to IS 1161-1979 grade St-240 complete all as specified and as directed by Engr-in-Charge
M&L for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, flat iron fillets (for securing wall cladding etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engr-in-Charge
Taking down old unserviceable point wiring complete including fittings complete all as specified and as directed by Engr-in-Charge
M & L point wiring with 1.5 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor FRLS PVC insulated 1100 volt drawn through and including PVC casing capping/conduit ISI marked, minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface, in mounted and including 1.2mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting electrical switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as directed and specified for the following:-
One light /fan point controlled by one 05Amps switch
One 5 Amps plug point independent board controlled by one switch
One three pin switch socket 5 Amps plug point on same board
All as per item No 63.00 above but with 2.5 Sqmm single core multi standard FRLS copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire 2.5 Sqmm FRLS copper solid conductor to common earth dolly complete all as specified and as directed by Engr-in-Charge
All as per item No 63.00 above but with 4 Sqmm single core multi standard FRLS copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire 4.0 Sqmm FRLS copper solid conductor to common earth dolly complete all as specified and as directed by Engr-in-Charge
Taking down unserviceable socket/switches/ceiling rose etc complete all as specified and as directed
S&F socket outlet 2/3 pin 5 Amps 240 volts flush type complete all as specified and as directed by Engr-in-Charge
S&F socket outlet 3 pin 5/15 Amps 240 volts flush type complete all as specified and as directed by Engr-in-Charge
S&F switches 6 Amps 240 volts flush type complete all as specified and as directed by Engr-in-Charge
S&F switches 15 Amps 240 volts flush type complete all as specified and as directed by Engr-in-Charge
S&F ceiling rose surface type Bakelite 65 x 50 mm with three terminals with ISI mark complete all as specified and as directed by Engr-in-Charge.
Taking down unserviceable tube light fittings 20w complete all as specified and as directed by Engr-in-Charge
S&F LED tube light fitting, 1x20 w, 230v .Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.Flicker free, high efficiency and robust industrial batten family suitable for Surface, Wall and Conduit mounting & connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified directed. Cat Pat No.BN308C LED20S-6500 L60 PSU WH of Phillips or equivalent makes as mentioned in list of makes
Taking down old unserviceable DBs of any capacity complete all as specified and as directed by Engr-in-Charge
S&F DB SPN 8 way with category of protection double door type IP-43 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed by Engr-in-Charge Make- Legrand Cat Part No 5076 11or equivalent makes as mentioned in list of makes Note : Front cover of enclosure shall be flush with with surface
S&F load line sheet metal enclosure vertical DB VTPN 8 way IP-54 IK-09 with metal double door suitable for MCCB 36kA, 160 Amps complete all as specified and as directed by Engr-in-Charge Note : Front cover of enclosure shall be flush with with surface
S&F in replacement MCCB 160Amps, 415v, 36kA, 3 pole including lugs, nut and bolts complete all as specified and as directed by Engr-in-Charge
S&F MCB DP 32 Amps, 415 volts 50 Hz AC supply, breaking capacity 10 kA, 'C' series complete all as specified and as directed by Engr-in-Charge
S&F MCB single pole 6 to 40 Amps, 240 volts 50 Hz AC supply,breadking capacity 10kA, 'C' complete all as specified and as directed by Engr-in-Charge
S&F sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB single pole of capacity 20 to 32 Amps complete all as specified and as directed by Engr-in-Charge
S&F ceiling fan 1200mm Sweep, 240 volt , BLDC white/brown including rod minimum length 1.5 m and bush , nut bolts , capacitors including drilling on roof and fixed 1 to 1.5 feet rod and connecting bolts etc complete all as specified and as directed by Engr-in-Charge Make; Havells model - Efficiencia NEO or equivalent make as mentioned in list of makes.
S&F 300mm sweep exhaust fan, 240 volt , 1400rpm opal white/brown colour including making hole of suitable size for fixing and making good to disturbed surface and fixing flap cover, nut bolts , capacitors including all accessories complete all as directed by Engr-in-Charge. Make; Havells model - Tubro force SP or equivalent make as mentioned in list of makes.
S&F 450mm sweep exhaust fan, 240 volt , 1400rpm opal white/brown colour including making hole of suitable size for fixing and making good to disturbed surface and fixing flap cover, nut bolts , capacitors including all accessories complete all as directed by Engr-in-Charge. Havells model - Tubro force SP or equivalent make as mentioned in list of makes.
S&F 450mm sweep wall mounted fan, 230volts, 50 Hz, fixing on wall with fan clamp/hook, connecting electrically complete all as specified and as directed by Engr-in-Charge Make : Havells V3 or equivalent make as mentioned in list of makes
S&F step type fan regulator, 220V, single phase complete all as specified and as directed by Engr-in-Charge
S&F street light fitting, LED type, 35 Watts, 240 Volts luminous more than 2000 lumen, efficiency not less than 100 lumem/Watt and accessories complete mounted on 40mm dia light grade GI pipe bracket 1.2 mtr long bent to shape, mounted on wall, connection complete all as specified and as directed by Engr-in-Charge
M&L for Sub main wiring complete with 2x1.5 Sqmm , single core , multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along walls roofs etc including 1.5 sqmm unsheathed FRLS copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed by Engr-in-Charge Note:- (i) All three wire/cable Phase, Neutral and Earth) shall run through for every individual circuit from the DBs. (ii) Three run of cable and one run of conduit shall be measured and paid as one unit in this qouted item
All as per item No 87.00 above but 2 x2.5 Sqmm and 1 x 1.5 Sqmm for earth wire complete all as specified and as directed by Engr-in-Charge
All as per item No 87.00 above but 2 x2.5 Sqmm and 1 x 2.5 Sqmm for earth wire complete all as specified and as directed by Engr-in-Charge
All as per item No 87.00 above but 2 x4.0 Sqmm and 1 x 4.0 Sqmm for earth wire complete all as specified and as directed by Engr-in-Charge
Supply, laying and testing and commissioning of under ground XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and as directed by Engr-in-Charge
Supply, laying and testing and commissioning of under ground XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure for under ground cable complete all as specified and as directed by Engr-in-Charge
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 50mm and inner dia 38mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure for under ground cable complete all as specified and as directed by Engr-in-Charge
Supply, laying of DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 90mm and inner dia 76mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure for under ground cable complete all as specified and as directed by Engr-in-Charge
Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out including forming of bottom for laying cable all as specified and directed by Engineer-in-Charge
Excavation in hard / dense soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out including forming of bottom for laying cable complete all as specified and as directed by Engr-in-Charge
Returning filling including spreading leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil not exceeding 50 meters and depositing where directed at a level n.exc 1.5 mtrs above the starting point complete all as specified and as directed by Engr-in-Charge
Supply and laying 50mm bore GI tubing medium grade ISI marked as laid in trenches/duct/fixing to pole/wall or in such similar position complete all as specified and as directed by Engr-in-Charge
S&F MCB TP 40 to 63Amps, 440V, breaking capacity 10 kA, 'C' series complete all as specified and as directed by Engr-in-Charge
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip 25×4mm connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed by Engr-in-Charge. Note: (i) Cost of earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (vi) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
M/s J. M. Enterprises
M/s Sriya Enterprises
Kathir Marketing Services
Allied Trading Company
bansal construction
M/s Pooja Enterprises
KRISHNA TRADING COMPANY
M/s Shiva Engineering
S S CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .