Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.4 L+₹1.4 L (3.47%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹43.6 L+₹2.7 L (6.54%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹44.7 L+₹3.8 L (9.24%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹46.2 L+₹5.2 L (12.8%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
16 Nov 2022, 6:00 pmClosed
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8476/22/E8
2022_MES_552005_2
8476/22/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category a i
9 documents required · 9 mandatory
₹500
GE NW VASCO
₹78,000
Yes
23 Dec 2022
5 Nov 2022
18 Nov 2022
5 Nov 2022
16 Nov 2022
10 Nov 2022
5 Nov 2022 - 9 Nov 2022
Amount
Demolition of reinforcement concrete as in roofs, floors (other than ground floor, beams, stair case landing, chajja and similar suspended works in any position not otherwise specifically provided complete all as specified and as directed
Separating, scraping and cleaning of reinforcement obtained from item No 1.00 here in before complete all as specified and as directed
Demolition of brickwork or stone/boulder masonery, built in cement mortar complete all as specified and as directed
Taking down chowkat or frames not exceeding 1.5 sqm each w/o taking of shutters from the frame complete all as specified and as directed
Taking down chowkat or frames exceeding 1.5 sqm each but not exceeding 4 Sqm each but without taking of shutters from the frame complete all as specified and as directed
Taking up or down steel tubing and connections including for refixing or removing to store 15 mm dia complete all as specified and as directed
Taking up or down steel tubing and connections including for refixing or removing to store 20 mm dia complete all as specified and as directed
Dismantling water tanks and removing to store of size exceeding 500 and not exceeding 1000 ltr complete all as specified and as directed
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed
Excavating over areas, not exceeding 1.5 m deep and getting out in any type of soil complete all as specified and as directed
Excavating over areas, exceeding 1.5 m deep and not exceeding 1.5 m deep and getting out in any type of soil complete all as specified and as directed
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for Plinth Beam & Dwarf Wall, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth for dwarf wall and getting out in any type of soil complete all as specified and as directed
M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed
M & L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed
M & L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed
M & L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed
M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed
M & L plain cement concrete in foundations, filling and mass concrete 1:2:4 Type B-2 using 40 mm graded aggregate (For Footing) complete all as specified and as directed
M & L plain cement concrete in foundations, filling and mass concrete 1:2:4 Type B-2 using 40 mm graded aggregate (For plinth beam/ dwarf wall / steps) complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm In any type of soil complete all as specified and as directed
Removing excavated material in soft/ loose soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate For Foundation,plinth beam, Including rafts as Mass Concrete complete all as specified and as directed
M & L for form work for rough finished surfaces of concrete measured flat for foundation,plinth beam complete all as specified and as directed
S & F TMT bars 12 mm dia of Grade Fe 500 including cutting, bending, binding & placing in position with binding wire complete all as specified and as directed
All as per Item No. 24.00 here in before but for 16 mm dia complete all as specified and as directed
All as per Item No. 24.00 here in before but for 20 mm dia complete all as specified and as directed
All as per Item No. 24.00 here in before but for 8 mm dia complete all as specified and as directed
All as per Item No. 24.00 here in before but in stirrups, spacers & binder for 8 mm dia complete all as specified and as directed
Demolition on cement concrete of any description and in any position not otherwise specifically
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for column complete all as specified and as directed
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for roof beam
M & L for form work to sides and bottom for rough finished surface of roof beam
Forming square grooves in plaster n exe 12mm deep and n exe 15mm on face
M & L For pre-cast cement concrete block masonry, Type C5 confirming to IS , ( 20mm Graded Aggregate ) With Solid Blocks, exc. 10 CM in Width and Setting in CM (1:6), Complete all as specified and as directed
M & L for form work for rough finished surfaces of concrete measured flat for Column (From Footing Top to Plinth Top) complete all as specified and as directed
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for plinth beam complete all as specified and as directed
M & L for form work for rough finished surfaces of concrete measured flat for plinth beam complete all as specified and as directed
M & L for form work for rough finished surfaces of concrete measured flat for Column (above plinth) complete all as specified and as directed
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for RCC lintel complete all as specified and as directed
M & L for form work for rough finished surfaces of concrete measured flat for RCC lintel complete all as specified and as directed
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for RCC roof slab complete all as specified and as directed
M&L for use & waste form work for fair finished surfaces of concrete measured flat for roof slab Complete all as specified and as directed
M & L for RCC- M-30 (Design Mix) using 20mm graded aggregate for fascia complete all as specified and as directed
M & L for form work for rough finished surfaces of concrete measured flat for fascia complete all as specified and as directed
M & L for rendering 12mm thick on fair faces of brick work or concrete surfaces in CM (1:6) to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed
M & L for rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:4) over soffit of RCC slabs landing, waist slabs, beams, roof/chajja projection roof Ceiling etc. to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately).
Supply only water proofing compound complete all as specified and as directed.
S & F Anodised aluminium frame for doors, windows, ventilators, Fixed Glazing with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
S & F 6.3 mm thk Sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 sq. m in each pane (For Doors) complete all as specified and as directed
M&L for prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed
S & F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane (For Glazing) complete all as specified and as directed
S & F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified and as directed
S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge
M&L for 12mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed
M&L for distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms / litre, of approved anufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and as directed
M&L for applying three coats of white wash on ceiling complete all as specified and as directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed
M&L for 100mm Thick PCC (1:5:10) SUB BASE E-2 TYPE complete all as specified and as directed
M & L For 150mm Thick PCC type D-2, 1:4:8 (40mm graded aggregate) complete all as specified and as directed
M & L For 100mm Thick PCC type B-1, 1:2:4 (20mm graded aggregate) complete all as specified and as directed
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M & L For bedding layer of mortar CM(1:4) 20 mm thick for laying floor finishes complete all as specified and as directed
M&L for 20mm thick maple wooden Sport Flooring complete all as specified and as directed
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed complete all as specified and as directed
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed
M&L for 75 mm thick plinth protection PCC (1:3:6) type C1 using 20 mm graded aggregate (0.6 m wide) complete all as specified and as directed
M&L for hardcore of broken stone or boulders of guage not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface all as specified and as directed.
M&L for APP based polymeric membrane weighting 3 kg/sqm minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specifed and as directed.
M&L for screed bed or bedding layer of mortar 10 mm thick cement mortar1:3 complete all as specified and as directed.
M&L for bituminous compound for waterproofing and caulking purpose complete all as specified and as directed.
Supply and installation of Clear Tough free standing and maintenance free glass back wall system confirming the WSF (WORLD Squash Federation) requirement made of 12 mm micron clear toughened glass with 4 panels 1 door, 4 fins, fixtures & fittings and all other materials for erecting the glass wall system. The height of the glass wall is 2130 mm above the finish floor level complete all as specified and as directed
Supply and fix LDPE septic tank designed to carry sewage and sullage water,excavation in any type of soil/rock, PCC 1:4:8 below foundation, vent shaft connection etc complete for 25 users conventional type complete all as specified and as directed
Excavating in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation etc. and getting out in soft/disintegrated rock complete all as specified and as directed
Returning and filling in, including, spreading, levelling, watering and well ramming in layersn.exc 25 cm in soft rock complete all as specified and as directed.
Removing excavated material n.exc 50 m and deposited where directed not exceeding 1.5 m above the startin point in rock complete all as specified and as directed
M & L for PCC 1:3:6 type C1 (using 20 mm graded agg.) as in benching, like works, hold fast block incl. necessary form work complete all as specified and as directed.
Use & waste formwork to flat to side of concrete fdn footing etc and similar work verticle or to batter fair finished surfaces of any description complete all as specified and as directed.
M&L Brickwork with sub class 'B' bricks in one brick thick honey comb walling, built in complete all as specified and as directed.
M&L for RCC type B1 1:2:4 (20mm graded stone agg) in precast reinforced wall or slab of any thickness set in cement mortar 1:4 and fixed complete all as specified and as directed.
M&L for TMT bars 6mm to 8mm dia cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or scruing with clips complete all as specified and as directed.
M&L for loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed.
M&L for 150mm bore Cl pipes with spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits / casing caping with fittings such as switches, ceiling roses, pendents, regulators,bells, sockets, tube light fittings etc, removing the materials / debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 86.00 here in before, but for one fan/exhaust fan point controlled by one, 5 Amp Switch one way complete all as specified and as directed
All as per item No 86.00 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
All as per item No 86.00 here in before, but for two way controlled by one , 5 Amp Switch one way complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/ debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 2.5 qmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as Tees, elbows, junction boxes etc, as required fixed in wall along with one run of 2.5 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, One run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs modular Switch single pole two way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular Socket outlet 2 in 1 , 6 Amps, 240 V complete all as specified and as directed
S & F in repairs modular Socket outlet 2 in 1 , 6/16 Amps, 240 V complete all as specified and as directed
S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
S & F in repairs Modular Fan step regulator, 120W - 2 module all as directed.
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
S&F in repairs MCB DB TPN 4 way DB 415 V with 200 A rated bus bar double door type complete all as specified and as directed.
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
M & L for exhaust fan AC single phase 230V of size 450 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan all as specified.
M & L for exhaust fan AC single phase 230V of size 300 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan all as specified.
Supply and fix ceiling fan, 1200 mm sweep, single phase, 230 volts, five star rated white in colour complete with all accessories such as down rod (required length at site), regulator, blades, shackle clip, canopy and making cable connections including removing of old unserviceable fans from existing site and deposited to MES store all as specified and directed .
S & F in repairs Energy efficient surface Mounted LED Batten Luminire 20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed.
S & F in repairs Energy efficient surface Mounted LED batten Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.
Supply and fix in repairs LED mirror light fitting 1 x 12 Watts WW, operating voltage 140 V to 265 V indoor decorative aluminum die cast, IP 42, complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs Flood light 150/160 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on Building by providing MS angle iron bracket of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed.
Supply and fix in repairs Building Security LED fitting 72-75 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on Building by providing MS angle iron bracket of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed.
Supply and fix in repairs GI bracket pipe of size 32/40 mm dia medium grade bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surfaces by providing suitable MS flat iron 32x6 mm clamps 2 nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts,bolts & washers and removing of old unserviceable item complete all as specified and directed
M/S jvsr constructions
Super Construction
M/s. P S REDDY
M/s. R.S. LAWANDE
M/S DUBAL CONSTRUCTION
Leela Enterprises
U k Enterprises
STAR FABRICATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .