| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L1₹9.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 3 | L1₹9.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 4 | L2₹10.9 L+₹1.1 L (10.6%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S QADRI ELECTRICALS L1 | M/s JB ELECTRICALS L2 | SOLARCITY ELECTRICALS AND SUPPLIERS L1 | BUDOO ELECTRICALS AND SUPPLIERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Charging of 43 no. un-commissioned EMC infrastructure (25KVA DT Substations) on Feeder no. 4 emanating from Receiving Station Bemina-2nd falling under the jurisdiction of ESD Watalkadal ED 3rd (Partial Turnkey Basis) | |||||||
| 1.01 | Supply, Installation, testing and commissioning of 35 mm² Single-Core Cable,1.1kV Grade XLPE Insulated Stranded Conductor un-armoured, FRLS type | 760 | Mtrs | 174 ₹1,32,240 | 170 ₹1,29,200 | 195 ₹1,48,200 | 100 ₹76,000 Lowest |
| 1.02 | Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of 11 KV Disc Insulators 12 KV, 45KN Complete with fittings (To be Provided Departmentally) | 3 | No. | 200 ₹600 | 300 ₹900 | 50 ₹150 Lowest | 180 ₹540 |
| 1.03 | Supply, Installation, testing and commissioning of 11 KV Polymeric composite Pin Insulator with pins 12kV, 5kN | 100 | No. | 250 ₹25,000 | 300 ₹30,000 | 240 ₹24,000 | 50 ₹5,000 Lowest |
| 1.04 | Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of LT Distribution Box for 25 KVA DTR (To be Provided Departmentally). | 30 | No. | 500 ₹15,000 Lowest | 4,500 ₹1,35,000 | 600 ₹18,000 | 3,000 ₹90,000 |
| 1.05 | Supply, Installation, testing and commissioning of MCCB ‐ 63 Amps, 36 KA, 4P adjustable | 13 | Nos | 8,500 ₹1,10,500 | 7,000 ₹91,000 | 5,500 ₹71,500 Lowest | 8,800 ₹1,14,400 |
| 1.06 | Providing of material and laying of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set &lighting arrestor as per IS 2629/85, GI nuts &bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 35 | No. | 3,000 ₹1,05,000 Lowest | 5,000 ₹1,75,000 | 3,200 ₹1,12,000 | 3,000 ₹1,05,000 Lowest |
| 1.07 | Supply, installation, testing and commissioning of 16 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, XLPE FRLS type | 1,500 | mtr | 180 ₹2,70,000 | 70 ₹1,05,000 Lowest | 192 ₹2,88,000 | 90 ₹1,35,000 |
| 1.08 | Fixing (including loading/ unloading/ carriage from Divisional store to site) of PG Clamps/ Wedge connectors (To be Provided Departmentally) | 30 | no. | 50 ₹1,500 | 100 ₹3,000 | 10 ₹300 Lowest | 10 ₹300 Lowest |
| 1.09 | Supply and fixing of GI Barbed Wire for Anti-Climbing with Clamps | 50 | kgs | 125 ₹6,250 | 200 ₹10,000 | 120 ₹6,000 | 10 ₹500 Lowest |
Tender Value
₹13.2 L
EMD Value
₹26,360
Closing Date
20 Sept 2025, 4:00 pmClosed
Executive Engineer, ED-3rd Srinagar
Office of Executive Engineer, ED-3rd Srinagar
Charging of 43 no. un-commissioned EMC infrastructure (25KVA DT Substations) on Feeder no. 4 emanating from Receiving Station Bemina-2nd falling under the jurisdiction of ESD Watalkadal ED 3rd (Partial Turnkey Basis)
2025_PDD_286857_1
ED-III /18 of 2025-26, Dated - 04/09/2025
Open Tender
Electrical Works
Turn-key
20 days
Office of Executive Engineer, ED-3rd Srinagar
Refer SBD, Technical Specification, Drawing
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED-3rd Srinagar
₹26,360
26 Sept 2025
4 Sept 2025
22 Sept 2025
4 Sept 2025
20 Sept 2025
8 Sept 2025
8 Sept 2025 - 18 Sept 2025
Amount
Charging of 43 no. un-commissioned EMC infrastructure (25KVA DT Substations) on Feeder no. 4 emanating from Receiving Station Bemina-2nd falling under the jurisdiction of ESD Watalkadal ED 3rd (Partial Turnkey Basis)
Supply, Installation, testing and commissioning of 35 mm² Single-Core Cable,1.1kV Grade XLPE Insulated Stranded Conductor un-armoured, FRLS type
Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of 11 KV Disc Insulators 12 KV, 45KN Complete with fittings (To be Provided Departmentally)
Supply, Installation, testing and commissioning of 11 KV Polymeric composite Pin Insulator with pins 12kV, 5kN
Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of LT Distribution Box for 25 KVA DTR (To be Provided Departmentally).
Supply, Installation, testing and commissioning of MCCB ‐ 63 Amps, 36 KA, 4P adjustable
Providing of material and laying of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set &lighting arrestor as per IS 2629/85, GI nuts &bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply, installation, testing and commissioning of 16 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, XLPE FRLS type
Fixing (including loading/ unloading/ carriage from Divisional store to site) of PG Clamps/ Wedge connectors (To be Provided Departmentally)
Supply and fixing of GI Barbed Wire for Anti-Climbing with Clamps
Fixing (including loading/ unloading/ carriage from Divisional store to site) of Galvanized Nuts and Bolts (To be Provided Departmentally)
Supply, Installation, testing and commissioning of MCB SP, 32 Amps
Supply, Installation, testing and commissioning of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply, Laying, Installation, testing and commissioning of 50 mm² ACSR Conductor
Supply, fabrication and Fixing of GI Channel/Angle Iron/Side channels including clamps/collars
Supply, Laying, Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of 120 mm² AB (HT) Cable (3x120 + 1x95 insulated) mm² XLPE(11 kV, 3C + Earth)
Supply and Fixing of Heat Shrinkable Outdoor Cable Termination Kit
Fixing (including loading/ unloading/ carriage from Divisional store to site) of Suspension/Tension Clamp with eye hook (To be Provided Departmentally)
Supply and Fixing of Danger Plates with Clamps
Supply and fixing of Anti-Climbing Device with Clamps
Providing and fixing of Pole Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3 mm
Providing and painting of poles with single coat of red oxide an two coats of Aluminum Paint
Providing of material and laying of Cement bottoming of poles (1:2:4 Mix as per REC Standards 0.48 M3 per Pole)
SOLARCITY ELECTRICALS AND SUPPLIERS (BID ID -2528200)
BUDOO ELECTRICALS AND SUPPLIERS (BID ID -2532622)
M/s JB ELECTRICALS (BID ID -2530328)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .