Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹34,900Qualified Make: LED STREET LIGHT
Model: sunmax 06 NAURANGA JALALPUR MOKAMA PATNA BIHAR 811302 | LAKHISARAI | BIHAR | 811302 | Make: LED STREET LIGHT
Model: sunmax | ₹34,900 | L1 | Qualified |
| 2 | L2₹58,725+₹23,825 (68.3%)Qualified Make: LED STREET LIGHT
Model: sunmax J 28 62 A AGAGANJ JAITPURA JAITPURA VARANASI VARANASI UTTAR PRADESH 221001 UDYAM UP 75 0025068 09BTHPG6520Q1Z6 B R | VARANASI | UTTAR PRADESH | 221001 | Make: LED STREET LIGHT
Model: sunmax | ₹58,725+₹23,825 (68.3%) | L2 | Qualified |
| 3 | Disqualified Make: hpl
Model: HPL( hplledsl1860p) 4G CHOTTI SRI GANGANAGAR RAJASTHAN 335022 | GANGANAGAR | RAJASTHAN | 335022 | Make: hpl
Model: HPL( hplledsl1860p) | - | - | Disqualified |
| 4 | Disqualified Make: Ascentech
Model: AT_SL_18 ASCENTECH LIGHTENING SOLUTION PLOT NO 150 151 A HSIIDC INDUSTRIAL AREA NEAR HSIIDC BUILDING SEC 59 BALLABGARH FARIDABAD HARYANA 121004 FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | Make: Ascentech
Model: AT_SL_18 | - | - | Disqualified |
| 5 | Disqualified Make: crompton
Model: LED STREET LIGHT 18 WATT, MODEL NO LSTS - 18 CDL ASTRA GAURAV GUNJAN COMPLEX G B MARG LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | Make: crompton
Model: LED STREET LIGHT 18 WATT, MODEL NO LSTS - 18 CDL ASTRA | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
18 Oct 2018, 11:00 amClosed
LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 25 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 3/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS:IS: 16103(Part-2)/2012 Type 3 * LED Rating (in Watts)/System Wattage/Rated Power 18W 18W 1/7 Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 * Warranty for free replacement (in years) 2 2 ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 with auto cutt off at below 120V * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) Upto 100W: ≥85%
Above 100W: >/=90% Yes * Total Harmonics Distortion ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer (as per Cl. 8 of IS:16104:2012 lates)" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature 6000+/-500K * Working life for LED (Minimum 50
000 burning hours as per LM-80 and LM 21 reports) Yes * Colour Rendering Index(CRI) ≥70 * LED Beam Angle ≥120 * Optic lense materal (UV stabilised) Poly carbonate lense * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Junctiojn/Soldering Yes * 2/7 point temperature shall not exceed 85 deg.c as per LM 80 report Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Operating temperature range -10 deg C to +50 deg C -10 deg C to +50 deg C Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M Ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV * The luminaire shall be protected against surges and transients of >/=10KV (External) Yes * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 IP66 * 3/7 latest Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
water
insects etc.
Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear (power supplies) 1 No. 1 No.
2 Nos.
3 Nos.
4 Nos. Light Source SMD LED Chip as per LM 80/IS16106 * Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase
Neutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm 50 cm MARKING "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed * 4/7 Manufacturer’s name
model number
serial number Yes * Date of manufacture (month-year)
and lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * Diameter of pole Luminiare suitable for: (upto 45W Pole OD: shall be 40mm)
(>45W<120W Pole OD: Shall be 50 mm)
(above 120W: OD shall be 60 mm for which luminiare is suitable Yes * REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILEDS/PHILIPS SYSKA/LUMENMAX EVERLIGHT/EDISON BRIDGELUX NATIONSTAR/REFOND * System must have EMI/EMC compliance as applicable (Test reports shall be furnish to the buyer/consignee on demand) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government Lab NABL/ILAC accrediated lab. Reports shall be furnish to the buyer consignee on demand (LM-79 report shall have total lumen output
power
PF
Current in Amps
CRI & CCT etc.
) Yes * LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological Yes * 5/7 report for LED report from Central Government Lab NABL/ILAC accrediated lab. Reports shall be furnish to the buyer consignee on demand (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) Availability of test Report from Central Government Lab NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-3/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * Seller shall furnish the Type test reports to the buyer/consignee on demand Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for road and street lighting shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 3): 2012 as applicable on date Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Birendra Singh 803116
RTC
CRPF
RAJGIR
NALANDA
BIHAR
pIN- 803116 25 15
691867
GEM/2018/B/97921
LED Luminaire (For Road and Street Lights)
15 days
Bihar; Nalanda
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| LED Luminaire (For Road and Street Lights) LED Luminaire (For Road And Street Lights) ( 25 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 3/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS:IS: 16103(Part-2)/2012 Type 3 * LED Rating (in Watts)/System Wattage/Rated Power 18W 18W 1/7 Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 * Warranty for free replacement (in years) 2 2 ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 with auto cutt off at below 120V * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) Upto 100W: ≥85% | - | - | - |
| Above 100W: >/=90% Yes * Total Harmonics Distortion ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer (as per Cl. 8 of IS:16104:2012 lates)" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature 6000+/-500K * Working life for LED (Minimum 50 | - | - | - |
| 000 burning hours as per LM-80 and LM 21 reports) Yes * Colour Rendering Index(CRI) ≥70 * LED Beam Angle ≥120 * Optic lense materal (UV stabilised) Poly carbonate lense * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Junctiojn/Soldering Yes * 2/7 point temperature shall not exceed 85 deg.c as per LM 80 report Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Operating temperature range -10 deg C to +50 deg C -10 deg C to +50 deg C Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M Ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV * The luminaire shall be protected against surges and transients of >/=10KV (External) Yes * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 IP66 * 3/7 latest Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust | - | - | - |
| water | - | - | - |
| insects etc. | - | - | - |
| Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear (power supplies) 1 No. 1 No. | - | - | - |
| 2 Nos. | - | - | - |
| 3 Nos. | - | - | - |
| 4 Nos. Light Source SMD LED Chip as per LM 80/IS16106 * Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase | - | - | - |
| Neutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm 50 cm MARKING "Manufactures Name and and brand on the aluminium die cast body " Engraved/Embossed * 4/7 Manufacturer’s name | - | - | - |
| model number | - | - | - |
| serial number Yes * Date of manufacture (month-year) | - | - | - |
| and lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * Diameter of pole Luminiare suitable for: (upto 45W Pole OD: shall be 40mm) | - | - | - |
| (>45W<120W Pole OD: Shall be 50 mm) | - | - | - |
| (above 120W: OD shall be 60 mm for which luminiare is suitable Yes * REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILEDS/PHILIPS SYSKA/LUMENMAX EVERLIGHT/EDISON BRIDGELUX NATIONSTAR/REFOND * System must have EMI/EMC compliance as applicable (Test reports shall be furnish to the buyer/consignee on demand) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government Lab NABL/ILAC accrediated lab. Reports shall be furnish to the buyer consignee on demand (LM-79 report shall have total lumen output | - | - | - |
| power | - | - | - |
| PF | - | - | - |
| Current in Amps | - | - | - |
| CRI & CCT etc. | - | - | - |
| ) Yes * LM 80 & TM 21 (Ref. IS:16105:2012) Report and Photo biological Yes * 5/7 report for LED report from Central Government Lab NABL/ILAC accrediated lab. Reports shall be furnish to the buyer consignee on demand (LM-80 report shall have the Pohoto Biological report of the LED Chip being used in the luminaire) Availability of test Report from Central Government Lab NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-3/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * Seller shall furnish the Type test reports to the buyer/consignee on demand Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for road and street lighting shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 3): 2012 as applicable on date Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Birendra Singh 803116 | - | - | - |
| RTC | - | - | - |
| CRPF | - | - | - |
| RAJGIR | - | - | - |
| NALANDA | - | - | - |
| BIHAR | - | - | - |
| pIN- 803116 25 15 | - | - | - |
Exempted
18 Oct 2018
4 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_691867.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .