COMMISSIONER OF UJJAIN MUNICIPAL CORPORATION
CHATRAPATI SHIVAJI BHAWAN, AGAR ROAD UJJAIN
CONSTRUCTION WORK OF G PLUS 1 COMMUNITY HALL AT NARAYANPURA IN WARD NO. 45
2026_UAD_491916_1
279/ZONE4/E-TENDER/2026
Open Tender
Civil Works - Buildings
Percentage
180 days
AT NARAYANPURA IN WARD NO. 45
PLEASE REFER TENDER DOCUMENT
4 documents required · 4 mandatory
₹5,000
₹28,100
18 Mar 2026
18 Mar 2026
22 Apr 2026
18 Mar 2026
20 Apr 2026
18 Mar 2026
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-I In cement mortar
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead For thickness of tiles upto 25 mm
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in.All kinds of soil.
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing completeCrusher Stone Dust
Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering fo
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 75 Kg/CM2 (average compressive strength) in superstructure above plinth level up to floor 2 level including the cost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand)
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete. 2.18.1 Moorum/Hard copra
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. 5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 75 Kg/CM2 (average compressive strength) in superstructure above plinth level up to floor 2 level including the cost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. 5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 75 Kg/CM2 (average compressive strength) in superstructure above plinth level up to floor 2 level including the cost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Suspended floors, roofs, landings, balconies and access platform
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 sand)
12 mm cement plaster of mix 1:4 (1 cement: 4 sand)
6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
Providing and laying vitrified floor tiles (without Soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm as per manufacturer specification
Applying one coat of cement primer of approved brand and manufacture on wall surface : Cement primer.
Providing and applying 1.0 mm thick white cement based wall putty of best quality, over plastered surface to prepare the surface even and smooth complete
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Granite of any colour and shade 8.2.6.1 Area of slab upto 0.50 sqm
Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- a) Short point
Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- b) Medium point
Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- Long point
3 Pin 6 Amp socket outlet on Separate Board a) Short point
3 Pin 6 Amp socket outlet on Separate Board b) Medium point
3 Pin 6 Amp socket outlet on Separate Board Long point
Point wiring including metallic switch box, sheet, switches, sockets for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
Circuit Wiring a) 2x2.5 Sq.mm.
Circuit Wiring b) 4x2.5 Sq.mm
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth co On Separate Board A. Short Point
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth co On Separate Board B. Medium Point
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth co On Separate Board C. Long Point
Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth co On Separate Board D. Extra Long -I
Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) with inbuilt electronic ballast ISI marked of approved make as required as per specification 20 Watt
Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) with inbuilt electronic ballast ISI marked of approved make as required as per specification 25 Watt
Suppling and fixing of approved make step type electronic Fan regulator including connection etc. as required on existing board
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments. Ceiling Fan (Energy Saver 60 W)-1400 mm Sweep
Supplying, erection and testing of approved make Wall Mounting fan complete with Wall Bracket ,canopy, blades, speed Regulator etc .A.C 230- 250 volts with connections and including raw bolt/Anchor hole fastener etc. complete finished and as required.400 sweep
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters using following hinges.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters to IS : 2202 Part-1 on one side only.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete with Hard wood.
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. 5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 75 Kg/CM2 (average compressive strength) in superstructure above plinth level up to floor 2 level including the cost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. 5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 75 Kg/CM2 (average compressive strength) in superstructure above plinth level up to floor 2 level including the cost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Suspended floors, roofs, landings, balconies and access platform
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 sand)
12 mm cement plaster of mix 1:4 (1 cement: 4 sand)
6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
Providing and laying vitrified floor tiles (without Soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm as per manufacturer specification
Applying one coat of cement primer of approved brand and manufacture on wall surface : Cement primer.
Providing and applying 1.0 mm thick white cement based wall putty of best quality, over plastered surface to prepare the surface even and smooth complete
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Granite of any colour and shade 8.2.6.1 Area of slab upto 0.50 sqm
Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
Point Wiring in surface rigid P.V.C. conduit system with Flush type Accessories Light Point/Fan Points. a) Short point
Point Wiring in surface rigid P.V.C. conduit system with Flush type Accessories Light Point/Fan Points. b) Medium point
Point Wiring in surface rigid P.V.C. conduit system with Flush type Accessories Light Point/Fan Points. Long point
3 Pin 6 Amp socket outlet on Separate Board a) Short point
3 Pin 6 Amp socket outlet on Separate Board b) Medium point
3 Pin 6 Amp socket outlet on Separate Board Long point
Point wiring including metallic switch box, sheet, switches, sockets for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
Circuit Wiring a) 2x2.5 Sq.mm.
Circuit Wiring b) 4x2.5 Sq.mm
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES On Separate Board A. Short Point
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES On Separate Board B. Medium Point
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES On Separate Board C. Long Point
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES On Separate Board D. Extra Long -I
Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) with inbuilt electronic ballast ISI marked of approved make as required as per specification 20 Watt
Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) with inbuilt electronic ballast ISI marked of approved make as required as per specification 25 Watt
Suppling and fixing of approved make step type electronic Fan regulator including connection etc. as required on existing board
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments.Ceiling Fan (Energy Saver 60 W)-1400 mm Sweep
Supplying, erection and testing of approved make Wall Mounting fan complete with Wall Bracket ,canopy, blades, speed Regulator etc .A.C 230- 250 volts with connections and including raw bolt/Anchor hole fastener etc. complete finished and as required. 400 sweep
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters using following hinges. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters to IS : 2202 Part-1 on one side only.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete with Hard wood.
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood
Chequered terrazo tiles 18-20mm thick with graded marble chips of size up to 6 mm in floors jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade using white cement.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
tender.pdf
Tender Documents • 1.85 MB
BOQ_581623.xls
BOQ • 0.35 MB
estimate.pdf
Other Document • 0.62 MB
drawing.pdf
Other Document • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .