Executive Engineer University of Kashmir
Construction Division
Electrification for Raising of 2nd Floor of Vice Chancellors Secretariat and Administration Block towards west side at Main Campus
2021_UDJK_135075_1
F(E.Tend)( UCD)KU/28/21
Open Tender
Electrical Works
Item Rate
365 days
Main Campus
As per NIT
5 documents required · 5 mandatory
₹2,600
Registrar University of Kashmir
Exempted
2 Sept 2021
17 Aug 2021
2 Sept 2021
17 Aug 2021
31 Aug 2021
17 Aug 2021
120 days
Amount
MAIN DISTRIBUTION BOARD Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed Out-door, double door lockable type, free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB & MCB's complete as required.( for VC secretariat) 2 No. 250 Amp TPN MCCB release of 36kA with Adjustable thermo magnitic and Rotary Handle. 3 nos. 160A TPN MCCB release of 36 kA with Adjustable thermo magnitic and Rotary Handle. 2 nos. 125A TPN MCCB release of 36 kA with Adjustable thermo magnitic and Rotary Handle. 1 nos. 100A TPN MCCB of 36kA with Adjustable thermo magnitic release and Rotary Handle. multifunctional meters with of CT's R,Y,B LED phase indicating lamp with MCB protection. BUSBARS 4 pole 360 Amp space for additional MCB TPNs Note; The contractor will have to submit ISO certification and internal Drawings. The Contractor will have to submit test certificates i.e (HV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and free service
MAIN DISTRIBUTION BOARD Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed In door, double door type, free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB & MCB's complete as required. 1 No. 250 Amp TPN MCCB release of 36kA with Adjustable thermo magnitic and Rotary Handle. 4 nos. 160A TPN MCCB release of 36kA with Adjustable thermo magnitic and Rotary Handle. 2nos. 125A TPN MCCB release of 36kA with Adjustable thermo magnitic and Rotary Handle. multifunctional meters with of CT's R,Y,B LED phase indicating lamp with MCB protection. BUSBARS 4 pole 360 Amp space for additional MCB TPNs Note; The contractor will have to submit ISO certification and internal Drawings. The Contractor will have to submit his test certificates i.e (HV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and free service
MAIN DISTRIBUTION BOARD for DG Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed In door, double door type, free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB & MCB's complete as required.( admin 2nd floor) 1 nos. 160A TPN MCCB release of 36kA with Adjustable thermo magnitic and Rotary Handle. 3nos. 100A TPN MCCB release of 36kA with Adjustable thermo magnitic release and Rotary Handle. multifunctional meters with of CT's R,Y,B LED phase indicating lamp with MCB protection. BUSBARS 4 pole 200 Amp space for additional MCB TPNs Note; The contractor will have to submit ISO certification and internal Drawings. The Contractor will have to submit test certificates i.e (HV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and free service
MAIN DISTRIBUTION BOARD Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed Out-door, double door lockable type, free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB & MCB's complete as required. 1 No.630 Amp TPN MCCB release of 36kA with Adjustable thermo magnitic and Rotary Handle. multifunctional meters with of CT's R,Y,B LED phase indicating lamp with MCB protection. BUSBARS 4 pole 800 Amp space for additional MCB TPNs Note; The contractor will have to submit ISO certification and internal Drawings. The Contractor will have to submit test certificates i.e (HV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears Panel should have minimum of 12 months of warrenty period certificate and free service
Providing, fixing, testing and Commissioning of 40- 63 RCCB 300mA including Double door enclosure suitable for RCCB as per requirement
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 35 sqmm 3 1/2 core
50 sqmm 3 1/2 core
70 sqmm 3 1/2 core
240 sqmm 3 1/2 core
300 sq mm 3 1/2 core
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade Through existing HDPE pipes/ Cable tray or on surface of following size Upto 35 sq. Mm
Above 35 sq. mm and upto 95 sq. mm
Providing/fixing of Manual Bus Bar Chamber 4P TYPE, Hinged type single door, surface type 200 Amp
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and fixing following way, Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) DB up to 160 A MCCB I/C & SP/TP MCB O/G (for 24 nos) Vertical three phase distribution board with provision for 4 pole MCCB upto 160A as incomer with three phase and single with out MCCB's and MCB's 4 way
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links 125 - 160 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 - 160 Amp 4 P MCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
Double pole
Supplying and fixing 2 A to 4 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required with Double door enclosure 40-63 A
Providing and fixing of 12-18 way Double door distribution Board
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note : Rates of Suitable PVC conduit included in above description for the follwing items of 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
2 x 6 sq.mm + 1 x 6 sq.mm earth wire Note: Wire for Gyser power point wiring from DB to outlets & for Sub main wiring of SPN DB.
2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring
4 x 6 sq.mm + 2 x 6 sq.mm earth wire for Sub main wiring
4 x 10 sq.mm + 2 x 10 sq.mm earth wire for Sub main wiring
4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 20 pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the through PVC conduit recessed in surface (Cost of conduit included) as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS including through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of Modular Switch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects
Providing and fixing of Lighting point wiring ( looping wiring) with 1.5 mm2 PVC insulated copper wire of FRLS including through PVC conduit pipe/ PVC channel with all necessary accessories including providing and fixing of ceiling rose of with round junction plate 5Amp switches of recessed in wall using Modular plate & MS box of required size, point taken upto D.B. duly tested and commissioned, etc.
Providing and fixing of fan point wiring with 1.5 sq. mm PVC insulated copper wire of FRLS including through PVC conduit pipe with all necessary accessories including providing and fixing of ceiling rose of with round junction plate 5Amp switches of recessed in wall using Modular plate & MS boxof required size, point taken upto D.B. duly tested and commissioned, etc.
Providing and fixing of Computer point/ TV point/ raw power point (in loop max 4 pts.) with 2.5 sq. mm PVC insulated copper wire including through PVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 2 nos. of recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 2.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned
Providing and fixing of Ac points using 6 sq mm PVC FRLS insulated copper wire of including through 1 inch heavy duty PVC conduit pipe and providing and fixing of 32 Amp Dp MCB 10KA C curve with enclosure including providing and fixing of 6 sq. mm PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned in all respects complete.
Providing/fixing of 140mm x 140mm LED slim 15 watt 230V Downlighter Recessed/ Surface mount including MS box of required size as per requirement, complete in all respects not less than 100 LM/W LM79-80, L70, 2KV Surge Protection
Providing/fixing of 2ft x 2ft 36 watt 230V Downlighter Recessed/ Surface mount including MS box of required size as per requirement, complete in all respects not less than 110 LM/W LM79-83, L70, 2KV Surge Protection
Providing/fixing of 4 ft LED slim 16 watt 230V Batten type mirror lights(T5), complete in all respects not less than 130 LM/W LM79-80, L70, 3KV Surge Protection
Providing and fixing of 12”x12” Metalic type exhaust fan complete with all accessories includindg Frame etc
Providing and fixing of 48 inches Sweep energy efficient ceiling fan of approved sample at site including wiring the down rods of standard length (30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc including Fan Junction MS box as required.
Providing and fixing of Fan dimmer Including MS box and Modular Plate 5Ampere 3 pin type.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections and modular plate etc. as required Telephone socket outlet
TV antenna socket outlet
20/25 A switch
6 pin 20/25 A socket outlet
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. D-link 1 run of cable
Supply and installation of flush mounted Enhanced Category 6 outlet. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover / blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover shall be provided to protect jack wiring. Single outlet faceplate with RJ-45 jack
Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged & lockable door including supply & fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 50 Pair
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
sypplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels / DBs etc.
Providing and fixing of GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required.
Providing and fixing of lighning conductor finial, made of 25 mm dia. 300mm. Long GI tube, having single prone at top, with 85mm. Dia. 6mm thick GI base plate including holes etc. complete as required.
Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)
PORTABLE FIRE EXTINGUISHERS 'Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases. 4 Kg. Capacity
Fire Alarm system for 2nd Floor of Administration Block Main Campus, University of Kashmir.
FIRE SYSTEM Supplying and fixing of following sizes of medium class conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. (DSR 1.17.1) 2 x 1.5 sq. Mm
(NS) Supply, installation, testing and commissioning of UL listed 2 Loop (each loop accessing minimum 160 detectors and 160 modules ) Addressable Fire Alarm Control Panel complete with 960 Character Liquid Crystal Display, with sufficient panel enclosure and cabinet size. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required. Panel shall be able to sense & indicate fire or fault.
(NS) Supply, installation, testing and commissioning of UL listed Intelligent Addressable Multi Criteria Smoke cum Heat Detector, optical type with blinking LED and being capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with Mounting Base. Below false ceiling
(NS) Supply, installation, testing and commissioning of UL listed Intelligent Addressable Double action manual pull station capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.
(NS) Supply, installation, testing and commissioning of UL Listed Fire Alarm Hooter (sound output of minimum 90 dB upto a distance of 30 meters),made Addressable with the help of Intelligent Addressable Signal Module, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with seperate power supply arrangement complete as required and suitable for wall/ceiling mounting.
(NS) Supply, installation, testing and commissioning of UL listed Addressable Fault isolator module complete as required for determining the short in a circuit and separating the segment having the short capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.
(NS) Supply, installation, testing and commissioning of UL listed Addressable Control Module complete as required for driving hooters, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
Providing and fixing of 4.5kg. capacity I.S.I. Marked. (IS : 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.
Re-electrification/ renovation of 1st Floor of Administration Block Main Campus, University of Kashmir.
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 50 sqmm 3 1/2 core
70 sqmm 3 1/2 core
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 3½ X 50 sq. mm (32mm)
3½ X 70 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade Through existing HDPE pipes/ Cable tray or on surface of following size 35 sq. mm up to 95 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 35 sq. mm up to 95 sq mm
Providing/fixing of Bus Bar Chamber 4P TYPE, Hinged type single door, surface type 200 Amp
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and fixing following way, Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) DB up to 160 A MCCB I/C & SP/TP MCB O/G (for 24 nos) Vertical three phase distribution board with provision for 4 pole MCCB upto 160A as incomer with three phase and single with out MCCB's and MCB's 4 way
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links 125 - 160 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 - 160 Amp 4 P MCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
Double pole
Supplying and fixing 2 A to 4 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole
Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required with Double door enclosure 40-63 A
Providing and fixing of 12-18 way Double door distribution Board
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note : Rates of Suitable PVC conduit included in above description 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
2 x 6 sq.mm + 1 x 6 sq.mm earth wire Note: Wire for Gyser power point wiring from DB to outlets & for Sub main wiring of SPN DB.
2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring
4 x 6 sq.mm + 2 x 6 sq.mm earth wire for Sub main wiring
4 x 10 sq.mm + 2 x 10 sq.mm earth wire for Sub main wiring
4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 20 pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS including through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of ModularSwitch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects
Providing and fixing of Lighting point wiring ( looping wiring) with 1.5 mm2 PVC insulated copper wire of FRLS including through PVC conduit pipe/ PVC channel with all necessary accessories including providing and fixing of ceiling rose of with round junction plate 5Amp switches recessed in wall using Modular plate & MS box of required size, point taken upto D.B. duly tested and commissioned, etc.
Providing and fixing of fan point wiring with 1.5 sq. mm PVC insulated copper wire of FRLS including through PVC conduit pipe with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches recessed in wall using Modular plate & MS boxof required size, point taken upto D.B. duly tested and commissioned, etc.
Providing and fixing of Computer point/ TV point/ raw power point (in loop max 4 pts.) with 2.5 sq. mm PVC insulated copper wire including through PVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 2 nos. of recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 2.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned
Providing and fixing of Ac points using 6 sq mm PVC FRLS insulated copper wire including through 1 inch heavy duty PVC conduit pipe and providing and fixing of 32 Amp Dp MCB 10KA C curve with enclosure including providing and fixing of 6 sq. mm PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned in all respects complete.
Providing/fixing of 140mm x 140mm LED slim 15 watt 230V Downlighter Recessed/ Surface mount including MS box of required size as per requirement, complete in all respects not less than 100 LM/W LM79-80, L70 2KV Surge Protection
Providing/fixing of 2ft x 2ft 36 watt 230V Downlighter Recessed/ Surface mount including MS box of required size as per requirement, complete in all respects not less than 110 LM/W LM79-80, L70, 3KV Surge Protection
Providing/fixing of 4ft 20 watt LED slim 16 watt 230V T5 tube light type Surface mount , complete in all respects not less than 130 LM/W LM79-80, L70, 3KV Surge Protection
Providing and fixing of 12”x12” Metalic type exhaust fan complete with all accessories includindg Frame etc
Providing and fixing of 48 inches Sweep energy efficient ceiling fan of approved sample at site including wiring the down rods of standard length (30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc including Fan Junction MS box as required.
Providing and fixing of Fan dimmer Including MS box and Modular Plate 5Ampere 3 pin type.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections and modular plate etc. as required Telephone socket outlet
TV antenna socket outlet
20/25 A switch
6 pin 20/25 A socket outlet
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supply and installation of flush mounted Enhanced Category 6 outlet. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover / blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover shall be provided to protect jack wiring. Single outlet faceplate with RJ-45 jack
Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged & lockable door including supply & fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 50 Pair
Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
sypplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels / DBs etc.
Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)
Dismantelling, shifting of old electrical/ telephone and set righting what so ever required to restore the power, telephone systems as per site requirement complete in all respects
Dismantelling of 23 no of AC's including handling, shifting and re installations of fuctional AC's with gas filling, additional piping/ control cabling etc, what so ever required to in all respects.
Design , Supply , Installation , Testing and Commissioning of Passenger Elevator including system control panel and with following specifications including all necessary Chanelles/Gauders and all other accessories complete, should have following technical parameters of Category A Note: Free maintenance for twenty-four months. The period of this maintenance shall commence from the date of handing over of the lift. Capacity / Load:8 Persons (Gear Less MRL) Speed: 1 MPS Type of drive: VF Regenerative (closed loop) Rise (m): as required. Serving: GF , 1st , 2nd floor Stops: 3Floors Controller type: ACD3-MRL/eq. Power Supply: 400/415 Volts 3Phase Operation: Full collective Car group: One car (simplex) Machine: PM Gearless ( located in Shaft on top of guide rails) Ventillation: Cross flow fans No. of Car entrance: One location front at all floors Hoistway/ Car entrance door: Centre opening, Glass , SS Hairline finish Traction Media: Flate Coated steel Belt Operation: Automatic Control: Simplex False ceiling Type: CD-41/eq False ceiling Finish: Stainless steel Hand rails: Stainless steel Mirror Finish on all sides of car Panels Flooring: Vinyl Car door finish: Stainless steel Landing door finish: Stainless steel Car & Hoistway Door Type: Central Operating (CO) doors AdvancedFeatures: E- call system, auto ionic sanitization Standard Features: Anti-nuisance Car Call Protection, Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off and Automatic Rescue Operation/ DC door operator COP: COP for Stops ≤ 12(950mm) in stain less steel Car position indicator/Hall button arrangements: LCD Monochrome Dot matrix multi color
Providing and fixing of Lighting/fan/exhaust fan/point wiring for lift with 1.5 mm2 PVC insulated copper wire of FRLS including through PVC conduit pipe/ PVC channel ) with all necessary accessories including providing and fixing of ceiling rose of with round junction plate 5Amp switches of recessed in wall using Modular plate of required size, point taken upto D.B. duly tested and commissioned, including holder etc.
Providing and Fixing of Bluck Heads including LED 9W lamp
Providing and fixing of 8 way Double door distribution Board
Providing and fixing of Heating points for lift using 4 sq.mmPVC insulated copper wire of FRLS including through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of Modular Switch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wiret as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects
Wiring for circuit (lift)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Rates of Suitable PVC conduit included in above description for the follwing items of 4 X 10 sq. mm + 1 X 10 sq. mm earth wire
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links for lift 125 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 Amp 4 P MCCB
PORTABLE FIRE EXTINGUISHERS 'Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases. 4 Kg. Capacity
Fire Alarm system for 1st Floor of old Administration Block Main Campus, University of Kashmir
FIRE SYSTEM D.S.R ITEMS Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (DSR 1.20.1) 20 mm.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. (DSR 1.17.1) 2 x 1.5 sq. Mm
(NS) Supply, installation, testing and commissioning of UL listed Intelligent Addressable Multi Criteria Smoke cum Heat Detector, optical type with blinking LED and being capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with Mounting Base. Below false ceiling
(NS) Supply, installation, testing and commissioning of UL listed Intelligent Addressable Double action manual pull station capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.
(NS) Supply, installation, testing and commissioning of UL Listed Fire Alarm Hooter (sound output of minimum 90 dB upto a distance of 30 meters),made Addressable with the help of Intelligent Addressable Signal Module, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with seperate power supply arrangement complete as required and suitable for wall/ceiling mounting.
(NS) Supply, installation, testing and commissioning of UL listed Addressable Fault isolator module complete as required for determining the short in a circuit and separating the segment having the short capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.
(NS) Supply, installation, testing and commissioning of UL listed Addressable Control Module complete as required for driving hooters, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
Providing and fixing of 4.5kg. capacity I.S.I. Marked. (IS : 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.
Sabtech Engineering Works
MIR ELECTRONICS
stage.html
html • 0.02 MB
finance_270394.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .