Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹41.1 L+₹92,480 (2.30%)Rejected-Finance | L2 | Rejected-Finance BEING L2 REJECTED | |
| 3 | L3₹43.0 L+₹2.8 L (6.99%)Rejected-Finance | L3 | Rejected-Finance BEING L3 REJECTED | |
| 4 | L4₹43.9 L+₹3.7 L (9.30%)Rejected-Finance | L4 | Rejected-Finance BEING L4 REJECTED | |
| 5 | L5₹45.0 L+₹4.8 L (12.0%)Rejected-Finance | L5 | Rejected-Finance BEING L5 REJECTED |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIRS AND REHABILITATION OF SOME STRUCTURAL MEMBERS CERTAIN BUILDINGS UNDER AGE B/R-I AT NAVAL STN KARANJA
2023_MES_613658_1
8699/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW KARANJA
D and above
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹90,000
Yes
7 Nov 2023
14 Aug 2023
13 Sept 2023
14 Aug 2023
11 Sept 2023
28 Aug 2023
Amount
Notes : (i) The work consists of 01 job as under:- TPP NO 18 FOR YR 2023-24 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department.
Removing, chipping and cleaning of existing loose and damaged concrete carefully upto 60mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete including cleaning the surface by air jet and stacking & disposal of unserviceable materials outside the premises including all necessary scafolding safety net, props etc. complete all as specified and as directed
Providing and applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/ltr and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation, necessary scaffolding, props, etc. as per requirement, complete all as specified and as directed
Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire surface of bars free from rust scales, loose material, dirt etc. and M&L for applying alkaline rust converting primer on the existing rebars and allowing it to react with rust and form a corrosion resistant, insoluble protective layer, as per manufacturer's instructions, including necessary scaffolding, props etc. complete all as specified and as directed. (Mode of measurement: per sqm of breaking area of concrete.)
Drilling Holes of 12mm dia upto 100mm deep in structureal members at the interval of 300mm in stagered manner or along the crack line in RCC structural member including cleaning of the holes by air blower and M&L for inserting 12mm dia NRV nozzles compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix the nozzles inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 hrs before grouting: Cut and remove nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc. complete all as specified and directed. The rate shall incude scaffolding and other necessary works.
Providing and injecting two part, low viscous, high strength epoxy resin based moisture insensitive liquid using pressure injector with accessories till nozzle refuses to accept the grout including mixing of grout material components in adequate proportions as per manufacturer's instructions by weight batching and grouting the mixed material into the structural member by grouting gun, maintaining desired pressure in the gun by air compressor and maintaining pressure at exit about 2 to 3 kg/cm2 by monitoring pressure guage at exit. The mixed grout should have following properties:- (i) Mixed Density 1.1 kg/I (at + 27°C); Viscosity ~ 250 mPas at + 30 °C and should comply according to ASTM C 881, Type II and IV, Grade-1, class E+F (i° Compressive strength >+ 70 N/ sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (i) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30oC cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle
M&L MS TMT bars 10 mm and above, cut to length , bent to shape required, including cranking bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed
Providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sam of application area of concrete.) complete all as specified and as directed. The rate shall include cost of scaffolding necessary for the work.
Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C.
Rebuilding the section of damaged RCC elements to its original size in thickness upto 60mm by providing and casting with ready to use non shrink, cementitious free flow micro-concrete having having compressive strength >60 N/sqmm (28 days) according to ASTM C 1107-99 including. drilling holes and fixing shear connectors, mixing the microconcrete with adequate quantity of water, placing, levelling the surface by grinding off cementitious slurry or cementitious joints diffencess if any and curing complete all as specified and directed. The rate to include cost of scaffolding as per site requirement.
M&L Formwork to sides of rough finish surfaces of concrete pillars, posts, struts, piers, columns, and stanchions fair finished surfaces of concrete etc all as specified and directed.
Fiber wrapping: Design, fabrication and supply of FRP system for strengthening of structural elements comprising of FRP sheet and compatible saturant, by dry/wet layup system including surface preparation: Grinding, moulding concrete substrate. Cleaning it with wire brush, removing oil, laitance if present. Rounding off sharp edges to minimum 25mm radius. Proofing:Applying epoxy primer on prepared substrate, filling holes and uneven surfaces with thixotropic putty, etc. complete. Wrapping: Wrapping the fibre sheet to structural element at desired orientation with application of compatible epoxy saturant using tamping roller to avoid any air voids. Sand pasting: Applying second coat of saturant, rectify air voids if any; paste the river sand on it to make surface rough to take further finishes. (Mode of measurement: Fiber area or application, not surface area of Rec member). Rate to include scaffolding as per site requirement. CFRP 230 GSM
Taking down cement or cement lime plaster, any description on brick or stone, concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed
Rebuilding the section of structural damaged RCC/PC elements to its original size and shape upto 20 mm thickness by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >=50 N sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/sqmm (7days) according to ASTM C 293-79 complete all as specified and as directed The rate shall include cost of scaffolding required for the work.
M&L 20 mm thick polymer modified ready mix cement based plaster on external surfaces complete all as specified and directed.
M & L 15 mm thick ready mixed cement base plaster on internal surfaces on brick or concrete surfaces complete all as specified and directed.
M&L 5 mm thick (average) polymer modified ready mix cement based plaster on ceiling surfaces finished even and smooth complete all as specified and directed.
M & L for new or old surfaces of exterior wall decorating and water proofing treatment to wal surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water & allow to dry. Fill visible cracks/ joints by chemistic crack seal caulking compound & allow to dry for 24 hours. Apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours. Thereafter apply 02 coats of chemistik PDS-50 (WB high build anti caronatin coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed.
M&L Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper on walls over a coat of chalk whiting primer complete all as specified and as directed
M/L Preparation of new plastered surfaces and applying three coats of white wash on ceilings complete all as specified and as directed
Note :1. Supplying & erecting scaffolding upto required height (max 25 to 30m) with necessary H frames, pipes, couplers, buckles, bracing, top platform with support railing at top necessary H-frames, pipes, couplers, buckles, bracing, top platform with support ralling at top etc. at an levels of building including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc 2. Providing and erecting temporary bamboo scaffolding around the building as required. The scaffolding is to be secured properly in position by bracings, ties clamps, etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work complete all as specified and as directed 3. Providing and fixing dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair work in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system at shown area before start of work, removal after completion of work, carrying out regular cleaning etc. 4. Supporting the structural components temporarily during repair and streghthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonallay at centre with each other using 40 B heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration, complete all as specified and as directed by Engineer-in-charge. (Note: Mode of measurement - per prop per repetition).
Note:-2 Structural retrofitting work shall be got executed through one of the specialist firm(s) listed below: - (a) Rebuild Technologies Services Pt Ltd 602, 6th Floor, Tulsee Chamber, Teen Petrol Pump, Thane (W) E (b) Techton Buildcons Pt Ltd 203, Plot No 6, Milenium Plaza, Sakinaka Telephone Exchange Lane, Off AK Road Andheri E-Mumbai 72 (c) Sanrachana Structural Strenthening Pt Ltd 103, 104, Monalisa CHS, Hariniwas Circle, Thane West - 400602 (d) USHTA Infinity Construction Co Pt Ltd Ushta House, C-17/79 Krishna Industrial Estate, Gorwa, Vadodara - 390016 India (e) Gubbi Civil Engineers 18/26 Dev Prayag CHS, Op Thanawala garage, Bhakti Mandir Road, Near Hari Nivas Circle Thane (W), Thane, Maharashtra 400602
Colaba Group Works
K N CONSTRUCTION
S N TRADERS
INDIA ENGINEERS AND CONTRACTORS
BALAJI TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .