Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Jan 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/SERVICING OF DG SET OF VARIOUS CAPACITY WITH ALLIED SERVICES IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2022_MES_569906_1
GE/EM/LKO/HOSP/T-65 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹60,000
Yes
15 Mar 2023
19 Dec 2022
16 Jan 2023
19 Dec 2022
14 Jan 2023
2 Jan 2023
Amount
Servicing/ maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of capacity 625 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc complete all as specified and directed.
Supply only lubrication oil filter for 625 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only paper bypass filter for 625 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only fuel filter for 625 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner inner for 625 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Suply only air cleaner outer for 625 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply Filter screen for 625 KVA DG Sets as existing make/model/type, complete all as specified and directed.
Material and Labour for checking of fan hub including minor repairs if any for 625 KVA DG set and checking for alignment complete all as specified and directed.
Servicing/ maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of capacity 320/400 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc complete all as specified and directed.
Supply only lubrication oil filter for 320/400 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only paper bypass filter for 320/400 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only fuel filter for 320/400 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner inner for 320/400 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner outer for 320/400 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only Filter screen for 320/400 KVA DG Sets as existing make/model/type, complete all as specified and directed.
Material and Labour for checking of fan hub including minor repairs if any for 320/400 KVA DG set and checking for alignment complete all as specified and directed.
Servicing/ maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of capacity 200 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc complete all as specified and directed.
Supply only lubrication oil filter for 200 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only paper bypass filter for 200 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only fuel filter for 200 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner inner for 200 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner outer for 200 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only Filter screen for 200 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Material and Labour for checking of fan hub including minor repairs if any for 200 KVA DG set and checking for alignment complete all as specified and directed.
Servicing/ maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of capacity 100/160 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc complete all as specified and directed.
Supply only lubrication oil filter for 100/160 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only paper bypass filter for 100/160 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only fuel filter for 100/160 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner inner for 100/160 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner outer for 100/160 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only Filter screen for 100/160 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Material and Labour for checking of fan hub including minor repairs if any for 100/160 KVA DG Sets and checking for alignment complete all as specified and directed.
Servicing/ maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of capacity 50/62.5/75 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc complete all as specified and directed.
Supply only lubrication oil filter for 50/62.5/75 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only paper bypass filter for 50/62.5/75 KVA DG sets as per existing make/model/type, complete all as specified and directed.
Supply only fuel filter for 50/62.5/75 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner inner for 50/62.5/75 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner outer for 50/62.5/75 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only Filter screen for 50/62.5/75 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Material and Labour for checking of fan hub including minor repairs if any for 50/62.5/75 KVA DG Sets and checking for alignment complete all as specified and directed.
Servicing/ maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of capacity 15/30 KVA such as injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters & oil, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, removing the existing engine oil, clean the oil sump and refilling with directed quantity of new oil & coolant top up, cleaning of radiator inside with solution i.e restore plus and outside thoroughly with solution(caustic soda with water) including trial and testing etc complete all as specified and directed.
Supply only lubrication oil filter for 15/30 KVA DG sets as per exissting make/model/type, complete all as specified and directed.
Supply only paper bypass filter for 15/30 KVA DG sets as per existging make/model/type, complete all as specified and directed.
Supply only fuel filter for 15/30 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner inner for 15/30 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only air cleaner outer for 15/30 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Supply only Filter screen for 15/30 KVA DG Sets as per existing make/model/type, complete all as specified and directed.
Material and Labour for checking of fan hub including minor repairs if any for 15/30 KVA DG Sets and checking for alignment complete all as specified and directed. NOTE FOR ITEM NO 1 to 48 :- (i) The 'C' Check maint spares parts and engine oil etc shall be measured and paid separately in relavent items of schedule and any other check as per menufacturer's instructions & minor repair as directed by Engineer-in-charge also deem in the quoated rate of schedule. (ii) servicing of DG Set shall be carried out through OEM authorised workshop.
Taking down radiator from Gen set of capacity 625 KVA after disconnecting the water connecting pipe and descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as specified and directed.
Taking down radiator from Gen set of capacity 320/400 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as specified and directed.
Taking down radiator from Gen set of capacity 200 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as specified and directed.
Taking down radiator from Gen set of capacity 100/160 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as specified and directed.
Taking down radiator from Gen set of capacity 55/75 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as specified and directed.
Taking down radiator from Gen set of capacity 15/30 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as specified and directed.
Dismantling and taking out Dynamo/alternator assembly of 12 Volts/24 Volts from the DG sets replacing the spare parts such as carbon brushes, springs, spring holders, brushes, bearings or any other part required for full functioning of machine and fixing and testing complete all as specified and directed.
Dismantling and taking out dynamo/alternators from DG set for rewinding and taking out the old coil, cleaning thoroughly and wound with new super enameled copper cord of existing size and gauge, varnishing, drying, heating as per manufacturer norms and fixed with dynamo/alternator properly testing and commissioning complete all as specified and directed.
S&F in replacement of radiator hoses of any size and any capacity of DG set and fixed properly with new jublee clips, clamps, nuts and testing complete all as specified and directed.
Dismantling and taking out the FIP (PT Pump Assy) for repairing by replacing the worn out gasket, filter, suction valve, discharge valve and fixing the same after calibration and testing of capacity 200 KVA / 250 KVA/320KVA/625 KVA DG set, complete all as specified and directed. (Note : Repairing & Calibration shall be carried out by authorised dealers only).
As per item No 58 above but for DG set of capacity 100/160KVA
As per item No 58 above but for DG set of capacity 55/75KVA
As per item No 58 above but for DG set of capacity 15/30KVA
M&L in repair overhauling/calibration of injector assembly for any make/model/capacity of DG sets including renewal of wornout parts such as copper gasket, injector nozzle and testing complete all as specified and directed. (Note :- Repairing/Calibration shall be carried out by authorised dealer only).
Supply and fixing of oil pressure gauge as per existing make/model/ capacity of any type of DG sets including taking down old one etc complete all as specified and directed.
Supply and fixing in repair AVR unit /CVR –II for 320/250/200KVA DG Set & testing etc complete all as specified and directed. (Make : Kirloskar/Cummins)
Supply and fixing in repair AVR unit /CVR –II for 100/160KVA DG Set and testing etc complete all as specified and directed. Make :Kirloskar/Cummins
Supply and fixing in repair AVR unit /CVR –II for 50/62.5KVA DG Set and testing complete all as specified and directed. Make : Kirloskar/Cummins
Supply and fixing in repair AVR unit /CVR –II for 30KVA/15 KVA DG Set and testing etc complete all as specified and directed. Make : Kirloskar/Cummins
Dismantling and taking out of defective water pump assembly from the the DG sets and supply and fix new water pump assembly for the DG sets of capacity 320/250KVA/200KVA including testing complete all as specified and directed.
Dismantling and taking out of defective water pump assembly from the the DG sets and supply and fix new water pump assembly for the DG sets of capacity 160KVA/100KVA including testing complete all as specified and directed.
Dismantling and taking out of defective water pump assembly from the the DG sets and supply and fix in repairs new water pump assembly for the DG sets of capacity 50KVA/62.5KVA including testing complete all as specified and directed.
Dismantling and taking out of defective water pump assembly from the the DG sets and supply and fix in repairs new water pump assembly for the DG sets of capacity 30KVA/15 KVA including testing complete all as specified and directed.
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 15 KVA to 62.5 KVA at site and transporting to the work shop for repair and refixed the same after repiar & testing complete after replaement of the following parts:-. (a) Over hauling of water body pump complete - 01 Job, (b) Supply and fix water body kit complete- 01 Set, (c) water body bearing - 02 Nos, (d) water body Hose- 01 Set
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 100 KVA to 160 KVA at site and transporting to the work shop for repair and refixed the same after repiar & testing complete after replaement of the following parts:-. (a) Over hauling of water body pump complete - 01 Job, (b) Supply and fix water body kit complete- 01 Set, (c) water body bearing - 02 Nos, (d) water body Hose- 01 Set
Dismantling and taking out the water body pump assembly complete from the DG set upto capacity 200 to 320 KVA at site and transporting to the work shop for repair and refixed the same after repiar & testing complete after replaement of the following parts:-. (a) Over hauling of water body pump complete - 01 Job, (b) Supply and fix water body kit complete- 01 Set, (c) water body bearing - 02 Nos, (d) water body Hose- 01 Set
Supply & fix battery terminals made of brass superior quality including taking down old one etc complete all as specified and directed.
Dismantling and taking out the dfective self starter assembly of any capacity (12V/24V) form the DG set and re-fixing the same after repair works including replacing the spare parts such as carbon brushes, springs, spring holder bushes, bearings, or any other spare part not mentioned herein but essentially required for proper functioning of the starter assembly complete all as specified and directed.
Dismantling and taking out self starter from DG set and taking out unserviceable old coil , cleaning thoroughly slot and rewinding the starter with super enameled copper conductor of existing size and gauge including varnishing drying, heating and re-fixing the same after repair including testing complete all as specified and directed.
Supply & Fixing flexible pressure hose for lubricant oil and fuel for any size/capacity/model/make of DG set including taking down old one etc complete all as specified and directed.
S & F PVC heavy duty transparent pipe of size 10 mm dia for Diesel tank indicator with suitable clamps fixed on any type of tank including taking down old one etc complete all as specified and directed.
S & F oil pressure cut out suitable for any model/make of DG set upto 320 KVA including takding down old one, complete all as specified and directed.
S & F water temperature cut out suitable for any model/make of DG set upto 400 KVA.including taking down old complete all as specified and directed.
Supply and fix ignition switch and key for DG sets of 100/320 KVA capacity including taking down old one complete all as specified and directed.
Dismantling the radiator of 625 KVA DG set its position and soldering of copper pipes, where leakage including rectifying leaks & cleaning radiator and PVC hose and fitting the same place and testing complete all as specified and directed.
Dismantling the radiator of 320/250/200 KVA DG set its position and soldering of copper pipes, where leakage including rectifying leaks & cleaning radiator and PVC hose and fitting the same place and testing complete all as specified and directed.
Dismantling the radiator of 160/100 KVA DG set its position and soldering of copper pipes, where leakage including rectifying leaks & cleaning radiator and PVC hose and fitting the same place and testing complete all as specified and directed.
Dismantling the radiator of 62.5 to 15 KVA DG set its position and soldering of copper pipes, where leakage including rectifying leaks & cleaning radiator and PVC hose and fitting the same place and testing complete all as specified and directed.
Material and labour for draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 15W40 complete all as specified and directed.
Material and labour for draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 20W40 complete all as specified and directed.
Supply and fixing in repair rotating rectifier assembly for 320/250/200 KVA DG set of any make and model, complete all as specified and directed.
Supply and fixing in repair rotating rectifier assembly upto 160/100 KVA DG set of any make and model, complete all as specified and directed.
Supply and fixing in repair rotating rectifier assembly upto 15/62.5 KVA DG set of any make and model, complete all as specified and directed.
Dismatling defective coupling assembly from the alternator & engine any capacity and make of DG set and carrying out the repair works/renewal of spare for proper functioning of the alternator and re-fixing the same and to the entire satisfaction of Engineer-in-Charge, complete all as specified and directed.
Material and labour for repairing/renewal of the existing broken/leaking PVC fuel over flow pipe of the DG sets of any capacity upto fuel tank placed externally from the DG sets complete all as specified and directed.
Supply and fixing rectifier diode for 200/320 KVA DG sets as per exising make/model/ size including taking down old one etc complete all as specified and directed.
Supply and fixing rectifier diode for 160/100 KVA DG sets as per exising make/ model /size including taking down old one etc complete all as specified and directed.
Supply and fixing rectifier diode for DG sets upto 62.5 KVA capacity as per exising make/size/ model including takding down old one etc complete all as specified and directed.
Supply and fixing voltmeter square/ round upto 500 Volts of existing size. Make : MECO/AE including taking down old one complete all as specified and directed.
Supply and fixing ammeter 0-300A as per existing size/make/model including taking down old one etc complete all as specified and directed.
Supply and fixing indicator lamp assembly 230/110 Volts as per existing make/model/size etc complete all as specified and directed.
S & F battery leads 95 Sqmm copper cable 1.5 Mtr long with brass terminals etc complete all as specified and directed.
S & F techometer as per existing size/make/model including taking down old one etc complete all as specified and directed.
S & F techometer cable in and out with adopters etc complete as per exisiting size/make/model complete all as specified and directed.
S & F asbestos rope 20mm dia for tightly covered the silencer exhaust pipe etc complete all as specified and directed.
Supply only coolant concentrate, complete all as specified and directed. Pert No SK 802 OIC Make : Valvoline
Material and labour for dismantling and taking out the alternator upto 625 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and re-assembling the rotor & stator complete with applying suitable greasing & oiling of bearing & moving parts and refixing the same on existing position and testing complete all as specified and directed.
Material and labour for dismantling and taking out the alternator above 200 KVA but upto320 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same on its position and testing complete all as specified and directed.
Material and labour for dismantling and taking out the alternator and taking out above 55 KVA but upto 62.5 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same on its position and testing complete all as specified and directed.
Material and labour for dismantling and taking out the alternator above 100 KVA but upto 200 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and re-assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts and refixing the same its position and testing complete all as specified and directed.
Supplying and fixing including testing of fuel feed pump for DG set of capacities upto 62.5 KVA including taking down old one complete all as specified and directed. Make as approved by GE
Supplying and fixing including testing of fuel feed pump for DG set of capacities upto 100/160KVA including taking down old one complete all as specified and directed. Make as approved by GE
Supplying and fixing including testing of fuel feed pump for DG set of capacities upto 200 KVA including taking down old one complete all as specified and directed. Make as approved by GE
Supplying and fixing including testing of fuel feed pump for DG set of capacities upto 320 KVA including taking down old one complete all as specified and directed. Make as approved by GE
Supplying and fixing including testing of fuel feed pump for DG set of capacities upto 625 KVA including taking down old one complete all as specified and directed. Make as approved by GE
Supplying, fixing lead acid battery 12 volts, 180 AH suitable for DG set including initial charging (Model No. FXPO-MHD1800 Exide New express or equivalent of other specified make) including connection & testing and taking down old one etc complete all as specified and directed.
Supplying, fixing lead acid battery, 12 volts, 150 AH suitable for DG set terminals including initial charging (Model No. FXPO-MHD1500 Exide New express or equivalent of other specified make) including connection & testing including taking down old one etc complete all as specified and directed.
Supplying, fixing lead acid battery, 12 volts, 110 AH with lead acid suitable for DG set including initial charging (Make- EXIDE / AMRON ) including connction and testing including taking down old one complete all as specified and directed.
Supply only distilled water for batteries, complete all as specified and directed.
Supply and fix new battery charger heavy duty type with volteter and ammeter, with copper wound transformer, suitable for charging 12 Volts 180 AH battery complete all as specified and directed.
Supply and fix battery charger heavy duty type with volteter and ammeter, with copper wound transformer, suitable for charging 02 Nos 12 Volts 180 AH battery complete all as specified and directed.
Supply and fixing turbo kit suitable for 625 KVA DG sets, complete all as specified and directed.
Supply and fixing turbo kit suitable for 400 KVA DG sets, complete all as specified and directed.
Supply and fixing turbo kit suitable for 320 KVA DG sets, complete all as specified and directed.
Supply and fixing turbo kit suitable for 250/200 KVA DG sets, complete all as specified and directed.
Supply and fixing turbo kit suitable for 62.5 to 100 KVA DG sets, complete all as specified and directed.
Supply, fixing and testing Self Starter 12 Volt, DC for DG Set of capacity upto 160 KVA (Make of DG Set Kirloskar/Cummins as per existing size and make) complete all as specified and directed.
Supply, fixing and testing Self Starter 24 Volt, DC for DG Set of capacity upto 320 KVA (Make of DG Set Kirloskar/Cummins) complete all as specified and directed.
Supply only DC 6/12 VOLT battery cell tester upto 180 AH battery complete all as specified and directed.
Supply only DC 6/12 VOLT battery hydrometer upto testing oof elecrolite specific grevity 180 AH battery complete all as specified and directed.
Supply & chelating cleaner Restore Plus solution Part No. AX1001098 Make : Cummins for engines cooling system complete all as specified and directed.
Supplying & fixing Exhaust Manifold as per exisitng make/model/type of capaicty 160/200 KVA DG set including taking down old one complete all as specified and directed.
Supplying & fixing Exhaust Manifold as per exisitng make/model/type of capaicty 100/62.5 KVA 100/110/125 KVA DG set including taking down old one complete all as specified and directed.
Supplying & fixing Exhaust Manifold as per exisitng make/model/type of capaicty 200/320 KVA DG set including taking down old one complete all as specified and directed.
Supplying & fixing Exhaust Manifold as per exisitng make/model/type of capaicty 625KVA DG set including taking down old one complete all as specified and directed.
Supplying & fixing Exhaust Manifold as per exisitng make/model/type of capaicty 100 KVA DG set including taking down old one complete all as specified and directed.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 250/200 KVA DG Set including taking down old one etc complete all as specified and directed.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 100/160 KVA DG Set including taking down old one etc complete all as specified and directed.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 50/62.5 KVA DG Set including taking down old one etc complete all as specified and directed.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 320 KVA DG Set including taking down old one etc complete all as specified and directed.
Supplying & fixing Exhaust Gasket as per existing make/model/type of capacity of DG set 15/30 KVA DG Set including taking down old one etc complete all as specified and directed.
Supplying & fixing Pipe water pipe of manifold A bank of capacity of DG set 30 to 200 KVA as per existing make/model/type including taking down old one etc complete all as specified and directed.
Supplying & fixing Pipe water pipe of manifold B bank of capacity of DG set 250 to 320 KVA as per existing make/model/type including taking down old one etc complete all as specified and directed.
Supply and fixing only off load changeover switch 63 Amps TPN with sheet metal enclosure ,side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed.
All as per Item No 142 above but 100 Amps
All as per Item No 142 above but 200 Amps
Supply & Fixing in repairs "ON LOAD" type Change over switch 630 Amps TPN front handle operated, on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC complete all as specified and directed.
All as per Item No 145 above but 315 Amps
All as per Item No 145 above but 250 Amps
All as per Item No 145 above but 200 Amps
All as per Item No 145 above but 100 Amps
All as per Item No 145 above but 63 Amps
Supply and fix in repairs 3 pole power contactor MNX400 auxilary contacts 2NO + 2NC suiable for 320 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/model for AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 3 pole power contactor MNX225 auxilary contacts 2NO + 2NC suiable for 320 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/model for AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 3 pole power contactor MNX110 auxilary contacts 2NO + 2NC suiable for 320 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/model for AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MCX44 auxilary contacts 2NO + 2NC suiable for 320 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/model for AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MCX42 auxilary contacts 2NO + 2NC suiable for 250 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/modelfor AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MCX41 auxilary contacts 2NO + 2 2NC suiable for 200 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/modelfor AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MCX33 auxilary contacts 2NO + 2NC suiable for 100 to 125 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/modelfor AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MCX22 auxilary contacts 2NO + 2NC suiable for 63 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/modelfor AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MCX12 auxilary contacts 2NO + 2NC suiable for 30-40 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/modelfor AMF panel boards etc complete all as specified and directed.
Supply and fix in repairs 4 pole power contactor MXC4 auxilary contacts 2NO + 2NC suiable for 15-25 KVA DG set ,415 Volts, 50 Hz or existing make/type/rating/modelfor AMF panel boards etc complete all as specified and directed.
Magneoflux
MTR GROUP & COMPANY
NEXT POWER ENTERPRISES
LARSEN AIR CONDITIONING & REFRIGERATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .