Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹69.1 L+₹14,430 (0.21%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹72.7 L+₹3.8 L (5.50%)Rejected-Finance 35 1 B M 1ST BYE LANE CHAPDANI HOOGHLY 712222 | CHAPDANI | HOOGHLY | WEST BENGAL | 712222 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
6 May 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
N K Das SE EL
NBDD UttarKanya Siliguri
Design Supply Installation Testing and Commissioning with 5 years comprehensive maintenance of Solar High Mast Lighting System at different locations of Itahar Block and installation of solar street light from Itahar Daspara to Itahar Polytechni
2022_NBDD_377641_1
NBDD/BS/SE /NIQ-04 - (EL) of 2022-2023
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Uttar Dinajpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹50,000
Yes
27 May 2022
22 Apr 2022
10 May 2022
22 Apr 2022
6 May 2022
22 Apr 2022
120 days
Amount
SITC of Solar high mast including foundation as per drawing: Supply of Solar High Mast, with 2 Day Autonomy, having 6 Luminaries of 52W each with Colour Temperature of 3000K. 10 Meter GI High mast, designed to sustain a wind speed of 180 KM/hr, with 6Pcs of 52W Led fixture enclosed in Pressure die cast Aluminum Housing, powder coated in silver grey and with Toughened glass, The 312W of Light will be backed up and powered by More than 3200 Wh of Lithium Ferrous Phosphate Based Battery Backup and the system will be charged by 900Wp of Solar PolyCrystalline PV Modules. 10 Meter Polygonal Pole, GI with necessary mounting arrangement for Solar PV Module & Light Fittings Mounting arrangement should be such that it is easy to maintain 6 Units of 52W LED Light with secondary Lens, in Aluminum Die Casting, IP66 Protection, Auto Switching Dask to Dawn, Led Driver cum charge controller should be equipped with the following features, MPPT based charge controller with Three stage battery charge monitoring algorithm, Greater than 90 percent efficiency, Short Circuit Protection, Battery Over- charge Protection, Battery Deep Discharge Protection, PV Reverse Voltage Polarity Protection, Battery Reverse Voltage Polarity Protection, Software Watch-dog for LED Over-current Protection, (Zero Dark Spot at ground level) 6 Units of 42Ah LiFePO4 Battery BIS approved, with easily replaceable mounting and wiring arrangement 6 Units of 150Wp Solar PV Modules Polycrystalline with RFID Tag All wirings with the modules should be made using 4Sqmm Solar cables, the connection with the Modules to be made using MC4 Connectors. System must have an inbuilt Remote Monitoring System, integrated with MPPT charge controller and it would record the parameters at a fixed interval of 10 Minutes, Recorded data should be available in the PDF, XLS, JPED, PNG & SVG Format with the Data logging of the following parameters 1. Battery: Voltage/Current/Power 2. Solar PV Module: Voltage/Current/Power 3. Load: ON-Off Status/Voltage/Current/Power 4. Fault description 5. Site Co-ordinates (Make: SOLARIZE (SOLHM52WX6WL )
Earthing with 50mm dia Gl Pipe 3.64mm thick x 3.04 Mts. Long and 1 x 4 SWG Gl (Hot Dip) wire (4 Mts. Long) 13mm. Dia x 80mm long Gl bolt, double nuts, double washers incl. S&F 15mm dia Gl pipe protection (1mts. Long) to be filled with bitumen partly under the gound level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed for Morrum Soil.
Supply & fixing of sticker (NBDD) of best quality water resistant reflective type and suitable size for pasting on steel tubular pole(as per EIC).
Supplying, Fitting and fixing Project Display Boards at different locations of project area made with M.S .Sheets and angle, including writing letters both Bengali and English encrypt of project name,project cost, necessary pictures, animations etc. including suitable section MS channel as per design properly fixing within ground of 1M below ground level and upto 4 mtr above GL with M15 grade of concrete including all paintings and complete in all respect as per direction of Engineer-in-Charge without electrical illumination works.
Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well. i) First 50 mtrs.
ii) Next 50 mtr.
iii) Next 50 mtr.
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (a) 100 mm dia
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. 100 mm dia.
Labour for jointing and lowering pipes including strainer within the tube well bore vertically with necessary sockets, special fittings and welding as required including cost of all jointing materials, hire charges of tools and plants, cutting pipes to required sizes, making threads, welding pieces together etc. as necessary as per direction of the Engineer-in-charge. (i)Upto 100 mm dia. pipe
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Supply, fitting, fixing and lowering the following with fabrication as required: (a)100 mm dia bottom cap.
©Do-----Do----100 mm dia M.S. Top cap with hole.
(g) Do-----Do----Threaded Adopter ( 100 mm Dia).
Supply, fitting, fixing 32 mm dia G.I. Pipe (TATA-M) column pipe for submersible pump lowering having 3-mtr average length including special threading in Lathe and S & F one Tata GI socket.
Embedding the clamped neck of the tube well by providing CC (6:3:1) base block around the tube well dimension 0.45x0.45x0.6 mt above ground level,neatly cemented finish(3 mm thick) at the base tube well.
a)100 mm dia (PVC blank Pipe)
Surging / Development and Yield test
Mobilisation and site clearance
Chemical and Biological testing of water sample
(a) Construction of cement concrete 1:2:4 base of size 450x 450x 450 mm using 20 mm down well graded rriver bazree flashed with the platform as per drawing including 10 mm thick plaster with neat cement finish and E/w in excavation for trenches , shuttering if required, curing etc complete as per direction of E-I-C.
(b) Construction of 1.8 m dia tubewell platform of cement concrete as per Direction of E-I-C (1:2:4) with 20 mm down river bazree of 75 mm thick over 75 mm thick cement concrete (1:4:8)with 30 mm down graded singles with construction of circular terain 150 x 150 mm size along the cement concrete 1:2:4 of 75 mm thick over 75 mm thick concrete platform of( 1:4:8) including 12 mm thick plaster ( 4:1) and net cement finish to the exposed including E/w in excavation in any kind of soil, including dressing ,shuttering, curing etc complete as per drawing & direction of E-I-C.
(c) Construction of drain of size 15 mm X 150 mm of cement concrete 1:2:4 using 200 mm down bazree of 75 mm with singles including 12 mm thick plaster 1:4 and neat cement finish including earth work in excavation , lebelling , dressing , shuttering , shoring etc complete as per direction of E-I-C
Supply , delivery & installation of 900 watt peak capacity Solar photovoltaic .array along with 1.00 H.P. capacity D.C. Submersible Pump (designed to use with Solar Power) of approved brand which output not less than 2000 Ltr/hours at Suitable Head including supply of all necessary materials of approved quality, labour etc. with all allied works as per approved design and direction of the E.I.C. System must be provided with above pump set with cable wire 3 core 2.5 sq.rnrn, control panel and protection with rain preventlng box and manual tracking system for solar photovoltaic panel. Motor of the pump set should be permanent magnet DC brush less type (PMDC), positive displacement type with helical rotors. Pump outer dia not more than 96mm, outlet dia 32mm. [ D.C. Submersible Pump and controller should carries a warranty of 1 year directly from the manufacturers 1 Earthing with SOmm dia G.!. pipe (lSI medium GI Pipe) 3.64mm thick and 3.04mtr. Long and 1X 4SWG G.!. (Hotdip ) wire (4mtr. Long) 13mm dia X 18mm long GI Bolts, double nuts, double washer including supply & fitting of 1Smmd dia GI pipe protection ( 1 mtr. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth on 3.6mtr. below the ground level and restoring surface duly rammed or morrum soil. Pump Make -Grundfoss I Lorentz I Any other Approved mak.e Solar photovoltaic array - Sova Power Limited.
For installation of Solar photovoltaic array Panels on the structure as per standard & approved drawing which will grouted either ground based by construction of foundation concrete . The Solar Panels will then be connected to the Pump Controller which in turn will be connected to the pump as well as tile level indicator of the water tank as per direction of E.I.C. Solar Panel which components will be Galvanized on MS are carry a warranty of 5 years
Supplying, delivery & erection pre-fabricated M.S. Steel structure of 3.00 Mtr. Height above G.L. for resting of 5000 Ltr. Capacity H.D.P.E. water storage tank of approved band capable of extreme weather condition including wind thrust upto 100 KM/Hour with fixing of necessary ladder, railing and painting with appropriate d weather coats including construction of R.C.C. foundation ( column structure ) including all allied works as per approved drawing and direction of the EIC.
Laying rising main. delivery main, overflow. washout pipe line with supplying fitting and fixing PVC pipes (ASTM-D Schedule-SO, medium duty ) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS ; 1239 (Part-l) with all necessary accessories, valves and fittings as per lSI mark including laying UPVC distribution main as per Deoartmental specification to feed the nearest to houses at least one habitation gate through stand post and complete the all works as per drawing and direction of EIC. (a) 32 mm HDPE make Supreme/Oriplast / Long last / Approved make
(b) 40 mm UPVC make Supreme/Oriplast / Long last / Approved make
(c) 32 mm UPVC make Supreme/Oriplast / Long last / Approved make
(d) 25 mm UPVC make Supreme/Oriplast / Long last / Approved make
(e) 15 mm UPVC make Supreme/Oriplast / Long last / Approved make
Supplying, delivery fitting, fixing of special water chamber of G.1. Sheeled of approved quality as per specification over and above the 3rd plate of the Hand Pump as per approved drawing cluding all fittings 83 per direction of the E.I.C. Make - Approved make
Construction of R C C Street. Stand Post with platform and 1 mtr. masonry drain with ordinary cement concrete M-15 (Mix 4:2:1) with 20mm down local hard stone (crusher broken including plastering 20mm (6: 1) with neat cement to platform as per dept. type drawing and design including tapping the distnbution main, supplying fitting, fixing, 15mm brass ferrule with necessary saddle piece with 20mm dia GI pipe of TATA make medium quality (considering total length of pipe upto 3 mtr.) with specials, 20mm dia gun metal wheel valve, 15mm dia gun metal bib cock, GI nipple, 20mm X 15 mm dia GI reducing socket etc. all of approved quality etc. all complete as per direction of EIC.
Supply & Installation of 3000 Ltr. Capacity water storage tank at a height of 3.00 mtr. staging of approved make & brand including punching of required holes for raw water and 2000 Ltr. Capacity tank for treated/clean water.
Extra carriage charges for transportation of all rnatertats related with the above work at working site by manual labour time to time by head load due to neccessibility of site if required with specific prior permission.
Supply ,Installation ,commissioning and trial run (for three months) of water treatment unit for removal of iron and Arsenic (with media) Treatment Units: 1.OxidationChamber 2.Pre Filtration unit 3.Arsenic treatment unit 4.Other as needed 5.UV treatment unit of adequate capacity
Complete overhauling of oxidation vessel, pre-filter vessel and backwash as and when required by engagement of labour (at least annually) (a) Complete removal of media from the vessels, breaking of clots and through washing and cleaning of all media. (b) Placement of all media with 10% fresh new media(lost during washing) inluding cost and carriage of the fresh media.
Complete Replacement of Mno2 green sand in the oxidation vessel and pre filter vessel as and when required by engagement of labour and equipment (The work to be executed on written permission from the E-I-C) which includes: complete removal of media from the vessel and placement of new media including cost and carriage.
Opertation and maintenance of entire instllation for 5 years(except day to day operation.a)Clearing of site ,checking of valves and pipes,checking of electrical connection,cleaning solar panel etc.twice a month. B)Replacement of damaged valves,bid cocks and any other parts of all unit as and when necessary.C)Repair/Replacement of pumping machinery i.e controller ,PVpanel,wiring,switches.
Lightning protection (Pole mounted): Lightning protection with 3" X1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (lSI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip)wire and 85 mm dia 6 mm thick GI base plate at bottom Incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (lSI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure).
UNIQUES
LAXMI ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .