Loading…
Loading…
Tender Value
₹4.4 L
EMD Value
₹8,816
Closing Date
25 Jun 2026, 12:00 pmClosed
Executive Engineer Cooch Behar Electrical Division
Executive Engineer Cooch Behar Electrical Division
Urgent Electrical Repairing Works of Main Incoming Sytem and Compound Lights at Pundibari Rural Hospital,Cooch Behar.
2026_WBPWD_5015479_1
WBPWD/EE/CED/NIT52/2nd/R/25-26
Open Tender
ELECTRICAL WORKS M/R
Item Rate
15 days
Cooch Behar
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,816
29 Jun 2026
15 Jun 2026
29 Jun 2026
15 Jun 2026
25 Jun 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of exixting Panel,Checking of old lines & rectification ,necessary connections by engaging Manpower [1(One)No Semi Skilled Electrician + 2 (Two)Nos Helper Electrician] and Co's own tools & tackles with proper care of electrical equipments and appliances as per direction of EIC | 7 | Man power per day | 1.25 | ₹8.75 |
| 2DBs,MCCB,MCBs,Isolator etc. Supplying and fixing double door Vertical TPN MCB Distribution board for Up to 160A MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen [ Make - Legrand Enclosure(607914 )/Schneider/L&T/ABB ] | |||||
| 2.01 | 12 Way | 1 | Nos. | 1.25 | ₹1.25 |
| 3Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmen[ Make - LegrandEnclosure Enclosure (607716)/Schneider/Siemens /ABB ] | |||||
| 3.01 | 6 Way | 2 | Nos. | 1.25 | ₹2.5 |
| 4Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for HorizontalVertical TPN DB enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment | |||||
| 4.01 | 6 Way | 4 | Nos. | 1.25 | ₹5 |
| 4.02 | 12 Way | 4 | Nos. | 1.25 | ₹5 |
| 5Supplying and fixing 415 V,MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make :- LEGRAND/SCHNEIDER/L&T /ABB) | |||||
| 5.01 | 100A Four Pole | 1 | Nos. | 1.25 | ₹1.25 |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.32 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Tendernotice_2.pdf
PDF • 1.03 MB
BOQ_5084294.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .