Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance PLOT NO 62 REDDY COLONY BUDVEL R R DIST TS 500030 | BUDVEL | RANGA REDDY | TELANGANA | 500030 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
7 Aug 2023, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPECIAL REPAIR TO BLDG NO E-65 OR LIVING ACCN, PROVN OF TILING FOR SALUTING DIAS AND SHED AND PROVN OF DRAINAGE IN FRONT OF CLKS TRG SCHOOL UNDER AGE B/R-I OF GE GOLCONDA
2023_MES_609415_1
8717/E8
Limited
Civil Works
Item Rate
120 days
HYDERABAD
As Per Tender
6 documents required · 6 mandatory
₹500
GE GOLCONDA
₹94,000
Yes
10 Aug 2023
17 Jul 2023
9 Aug 2023
17 Jul 2023
7 Aug 2023
31 Jul 2023
Amount
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified and directed.
Dismantling battens for tiles, shingles etc of any size including tilting fillets n exc 15 cm centre to centre complete all as specified and directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
M & L pre-painted galvalume aluminium zinc coating GI based corrugated mangalore profile sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. Note: Rate quoted deemed to include cost of making good disturbed masonry surface to match with existing etc using PCC 1:2:4/brick work/cement mortar 1:4 complete all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed
S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
Drilling holes round, drill or cut in second class hardwood diameter or side not exc 15 mm dia and complete all as specified and directed
S & F for mild steel screw bolts of 5 to 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 10 cm. but not exc 15cm complete all as specified and directed
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to anin half brick thick walls built in cement mortar 1: 4
Taking down cement plaster on wall of any desdriptions incl racking out joints for key scrubbing with water etc. complete all as specified and directed
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick with IWPC @ 3% over a coat of 10 mm thick ) on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed ( Note: IWPC measured separately )
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed
M&L for two coats of oil bound distemper over a coat of chalk whiting primer on newly plastered surfaces including 3mm thick wall care putty on wall including preperation complete all as specified and directed
M&L for preparing new plastered surfaces and applying Two coats of cement based paint over a coat of alkali resistant primer on surfaces of walls complete all as specified and directed
M&L for complete removal of existing treatment and applying two oil bound distemper over a coat of chalk whiting primer on old surface of walls including 3mm thick wall care putty on wall complete all as specified and directed
M&L for complete removal of existing treatment and applying two coats of cement base paint over a coat of alkali resistant primer on walls surfaces complete all as specified and directed
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed
Taking down shutters of any description not exceeding 1 Sq. M each and removing complete all as specified and directed
Taking down shutters of any description exc. 1.0 Sq. M but not exc. 2.0 Sqm each and removing complete all as specified and directed
S&F for glazed/gauzed II class hardwood 30mm thick skelton shutters open rebated and prepared to receive glass, gauze etc divided in to squares with sash bars plain chamferedor rounded, mitred and rebated sash bars complete all as specified and directed
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges
S & F 125 mm long mild steel wire type I Gate and shutter, hook & eye.
S & F 100 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt.
S & F 125 mm size mild steel pressed handles, oval type, stove enamelled black
M & L for hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
S & F for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty or wooden beading in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed
S & F 35 mm thick Second class hard wood plain, framed, factory made panelled shutters (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), Kiln seasoned and chemically pressure treated complete all as specified and directed
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges.
S & F 150 mm size mild steel pressed handles, oval type, stove enamelled black
S & F 125 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt.
S & F for 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed
M & L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets complete all as specified and directed
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed suface with precoated capping, main tee of size 24x32mm at every 1200mm c/c and cross tee of size 24x27mm (1200mm & 600mm long) at every 600mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 3mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 9mm thick gypsum board of size 600mm X 600mm with rear size aluminium foil and front side PVC lamination complete all as specified and directed.
M&L Rendering 5 mm thick in CM 1:3 on fair faces of brick surfaces of ceiling finished the surface fair and even omplete all as specified and directed.
M & L preparation of new surfaces of walls plastered or unplastered and applying three coat of white wash on ceiling to obtain uniform surfaces including making good the surface complete all as specified and directed.
M&L for Praparation of old plastered surfaces and applying One coat of White wash on Ceiling complete all as specified and directed
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick (Below or above ground level) complete all as specified and directed
Dismantling slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed complete all as specified and directed
M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base and finishing surface of concrete even and rough to receive the topping layer complete all as specified and directed
M&L for Machine cut kota stone slab flooring 20 -25mm thick over & incl cement screed base CM(1:6) 20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Excavating post holes or similar holes, each not exc 0.5 Cum, getting out in hard dence soil , returning, filling and ramming earth and broken rubble mixed with earth around , in layers not exceeding 25cm, watering and removing surplus soil complete all as specified and directed
M& L for plain cement concrete type B1 1:2:4 (using 20mm graded stone agg) in foundation filling, mass concrete and similar works and for fixing of MS pipe
M&L for 100mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in sub base and finishing surface of concrete even and rough to receive the topping layer.
M&L 20mm thick Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment tomatch the shade of granite stone including grinding and polishing complete and incl chamfeirng/rounding the edges over 15mm thick cement screed in CM 1:4 complete all as spd and as directed (Colour and design approved by Engr in charge).
M&L 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admix- ture of pigment to match with shade of granite and incl chamfeirng/rounding the edges over 10mm plaster in CM 1:4 complete all as spd and as directed (Colour and design approved by Engr in charge).
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense soil complete all as specified and directed.
M & L for Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc.10cm in width and setting in mortar 1:4 complete all as specified and directed.
M & L for Plain Cement Concrete Type B-0 1:2:4 (using 12.5 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates/Hunching and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed.
M&L for plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement complete all as specified and directed.
M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
M & L for Removing Excavated soils exceeding 250 M but not exceeding 1.5 KM and depositing where directed complete all as specified and directed.
Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc. all as specified and directed.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed type on stone / brick, masonary walls, roof etc including new CI/MS sunken box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified and directed.
All as per item No.61 but One 5 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed
All as per item No.61 but One 5 pin 5/6 Amps switch socket outlet on same board complete all as specified and directed
All as per item No.61 but for One 5 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed
S&F in repairs switch piano flush type single pole one way 5/6 Amps complete all as specified and directed
S&F in repair switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/5 pin with porcelain base complete all as specified and directed
S&F Switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and directed
S&F lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed
S&F Fan Regulator (Rotary step type, Switch/Socket type Dimmer) 230/240V, AC complete all as specified and directed.
S&F in repair 9 W LED bulb of base B22d with color temp 6500K complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), extruded aluminium batten in anodised finish with opal diffuser, IP20 heat sink provided for efficient heat dissipation and integrated electronic driver, lamp color white complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
Fixing only LED lights fittings of any type and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED light fittings, 1x10 watts bulk head luminaires etc complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 100 Amps bus-bar single pole and neutral 240V, 8 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.
All as per item No.76 above but TPN 4 way, 415 V complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6-32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP of current carrying capacity 40 to 100 AMP in the DB complete with connection testing and commissioning complete all as specified and directed.
Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for concealed type and making good the disturbed wall surfaces to match with existing specification all as required at site complete with all as specified and directed.
All as per item No.81 above but Sub main wiring using four runs of 6.0 sqmm wire with two runs of 4.0 sqmm earth wire complete all as specified and directed.
S&F in repair bracket suitable for fixing of building security light fitting made out from 40 mm bore GI pipe, medium grade 2 metre in length, made to shape as required, fixed to pole with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc complete including necessary nuts, bolts & washer etc as required and complete all as specified and directed.
Taking down Ceiling fan, sealing cable end, dismantling blades and removing fan and blades and refixing ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
M&L fabricated of iron bands,straps,supports or stays for rain water ,ventilating pipes including bolts if required hooks(stay) heavy for large gates ,hook and pintle hinges,large hasps and staples ,chains,hand made slidings bolts clamps hold fasts,wall ties hook for hanging fans,plain angles cleats for securing purlins to wood trusses or rafters ,knee piece inserts two way and three way straps plate washers and similar small articles conforming to Fe 290 Gde E-165, including clamps nuts,bold,fixing and old one complete all as specified and directed at site.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35.0 sq mm 4 core complete all as specified and directed.
M & L for cutting of hard standing made of concrete ,soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved M-Sand / Robo Sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 115 x 75mm for cable protection complete all as specified and directed.
m/s s indra reddy constructions
SANJEEV CONSTRUCTIONS
M/S SAI MURALI ENTERPRISES
SREE KIRAN ENGINEERS
RAFEEQ AND CO
M/S Veerabhadra Constructions
NAVANAND ENTERPRISES
GNV Engg Services
BUILDWEL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .