| 1 | L1₹29.4 LAccepted-AOC 0 FUTANA OLI NEAR KAL BHAIRAV MANDIR KAMPTEE ROAD KAMPTEE NAGPUR MAHARASHTRA 441002 | 441002 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹30.0 L+₹57,800 (1.96%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹33.6 L+₹4.1 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Not the lowest e-tenderer | |
| 4 | L4₹37.6 L+₹8.2 L (27.7%)Rejected-Finance | L4 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
29 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Santosh Pandey
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
DEFECT RECTIFICATION THROUGH RISK AND COST CONTRACT IN MAP PH 1 ACCN AT KALINA MILITARY CAMP UNDER GE NORTH MUMBAI
2020_MES_399770_1
83986/N/E8
Open Tender
Civil Works
Item Rate
180 days
GE NORTH SANTACRUZ
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH SANTACRUZ
₹70,000
15 Feb 2021
1 Dec 2020
30 Dec 2020
1 Dec 2020
29 Dec 2020
17 Dec 2020
1 Dec 2020 - 22 Dec 2020
60 days
Amount
Taking down cement plaster on brick or stone/concrete surfaces, etc. on internal/external surface of wall/ceiling including raking out joints, hacking for key, scrubbing down with water to receive plaster and removing debris out side MD land complete all as specified and as directed by Engr-in-Charge.
M & L for rendering 10mm thick plaster in CM (1:6) on fair faces of the brick or concrete surfaces of internal wall and finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge
M & L for rendering 15mm thick (10 + 5) plaster in CM (1:4) on fair faces of the brick or concrete surfaces using water proofing compound @ 3% by the weight of cement or as per manufacturer instructions and finished the surface even and smoothr without using extra cement complete including steel scaffolding for working up to 12mt with safety measures all as specified and as directed by Engr-in-Charge Note :- (i) Water proofing powder shall be mixed in CM only with second coat i.e. 5mm thick. (ii) WPC will be measured & paid seperately as "Supply only".
M & L for rendering 5mm thick plaster in CM (1:3) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge
M & L for preparation of new plastered surfaces of wall including 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed by Engineer in Charge. Make: SHALIMAR / BERGER / NEROLAC / ICI LTD/ASIAN (Tractor Brand)
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engr-in-Charge.
M & L for preparing of new plastered surfaces of wall/ceiling by scrapping/rubbing and applying two coats of Acrylic weather proof exterior paint over a coat of acrylic primer complete including scaffolding complete all as specified and as directed by Engineer-in-Charge and as per manufacturers instructions. Make- (a) Asian Paint - Apex Ultima Protek. (b) Berger Paint - Weather coat smooth. (c) Nitco Paint - Outshine premium 100% acrylic exterior (d) ICI Dulux - Weather shield exterior.
Taking down shutters of any description n.exc 1 sqm each including fittings & removing clear off site after credit for the same is recovered by dept complete all as specified and as directed by Engr-in-Charge
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm each including fittings & removing clear off site after credit for the same is recovered by dept complete all as specified and as directed by Engr-in-Charge
S & F stainless steel butt hinges, heavy duty of 100mm size complete all as specified and as directed by Engr-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F for providing moulded door shutter consisting of solid core, single leaf, flush door of 30mm thickness, lipped with 15mm thick (5mm x 3) x 30mm with on stiles and top rails and 10mm (5mm x 2) thick x 30mm width on the other stiles and bottom rails, the inner panel laminated with 2mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2, 4, 6 raised panel design in different plain and or prelam colours on one side after rooting the moulded design on flush door and 2mm plain and or prelam PVC sheet on other side using rubber based adhesive on flush door and solvent cement adhesive on the PVC lipping etc complete as per direction of Engr-in-Charge , Manufacturer's specification and drawings complete all as specified and as directed Make-RAJSHRI Plastiwood, M/S Sintex Industries Ltd, M/S Accucell, M/S Dura Plast Extrusion
S & F 2nd class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, sectional area n exc 3 sqcm, secured with nails or brads complete all as specified and as directed by Engineer-in-Charge
S & F extruded aluminium alloy handles, fabricated type, anodised, of size 125 mm complete all as specified and as directed by Engr-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F 40mm dia cupboard knob, fixed with nut, screw and washer of brass polished complete all as specified in drawing and directed by Engineer-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish out side MD land complete all as specified and as directed by Engr-in-Charge.
M & L for 25mm thick cement concrete PCC 1:2:4, type B-1, using 20 mm nominal size graded crushed stone aggregate as levelling course and finishing the surface even and fair complete all as specified and as directed by Engineer-in-Charge
M & L for non skid coloured ceramic tiles (group B II), 7 to 8mm thick (square/rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed of 15mm thick in CM (1:6) complete all as specified and as directed by Engr-in-Charge. Make:M/s H R Johnson/M/s Orient Bell Tiles/M/s Kajaria/M/s Somany Tiles Ltd/M/s Nitco tiles/M/s Swastik Tiles
M & L for glazed coloured ceramic tiles (Group B III), 1st quality of size 300 x 200 x 7 mm thick (or nearest size) on vertical surface such as skirting, dado, riser/steps etc, set and jointed in neat cement slurry and pointed in colour cement to match including backing coat 10 mm in CM (1:4) complete all as specified and as directed by Engr-in-Charge. Make:M/s H R Johnson/M/s Orient Bell Tiles/M/s Kajaria/M/s Somany Tiles Ltd/M/s Nitco tiles/M/s Swastik Tiles
M & L Drilling and fixing Teflon nozzles in RCC members, including drilling holes (drilling 12 mm dia, 40mm deep holes in structural members at the intervals of 600mm c/c in staggered manner or as directed by Engineer-in Charge in RCC structure elements and cleaning the holes (to clean the holes by air blower prior to fixing nozzles) and fixing of nozzles (to insert 12mm dia teflon nozzles in cleaned holes), external end of nozzles to be machined to receive outlet of grouting gun and fixing it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and curing the system for minimum 12 hrs and cutting of nozzles (to cut the nozzles by chisel after completion of grouting without damaging structural elements etc complete all as specified and as directed by Engineer-in-Charge.
M & L for Injecting low viscosity (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories, till nozzles refuses to accept the grout including mixing of materials( Mixing material components (part a & b) in required quantities as per manufacturer’s instruction by weigh batching and Grouting, Filling the grouting gun with monomer, Maintain desired pressure in the gun by air compressor; maintain the pressure at exit (4 to 5 Kg/ Cm2) by monitoring pressure gauge at exit, grouting the material through prefixed nozzles in the structural elements till its refusal, sealing the nozzle with epoxy putty after the refusal, monitoring leakages through other nozzles while grouting and seal them as per the requirement, repeat the process for all the nozzles the operation to be within pot life of the material.and Cleaning of gun and accessories (The gun and accessories like valves, pipes and other fixtures to be cleaned with thinner after the operation to avoid jamming of the gun.) etc complete all as specified and as directed by Engineer-in-Charge.
S & F flexible single componund, liquid applied, pure polyurethane water proofing membranes ECMACOAT FLEX PU 40 ( single componund, self levelling, thixotropic , self curing solvent based, bitumin/ tar free, PURE POLYURETHANE based liquid applied membranes having minimum solid contents >93 %, vOC less than 70gms/ ltr, elongation > 550 % and tensile strength > 2.50 mpa with minimum crack bridging of 2.5mm , to be applied by brush or roller or spraying in two coats to achieve 1.2mm ( DFT) @ 1.5 Kg / Sqm, water proofing membranes to be terminated on parapet wall in a V groove of size 25 x 25mm atleast 300mm above FFL, which should be sealed with polymer mortar, before application ECMACOAT FLEX PU 40, surface should be primed with ECMACOAT PUPRIME @ 200 gms / sqm, quoted rates should be including cleaning of mother concrete surface to remove dust loosely adhering particles, oiling grease, etc completely using suitable means, making of corner fillets 50mm and repairing wall cracks & construction joints by cutting and filling with ECMAS polymer modified mortar, providing and laying 150 GSM Geo textile layer over the water proofing coating for protection of membranes, laying protective screed (average 50mm thickness) of M-20 grade RMX concrete admixtured with integral water proofing Ecma guard WPL & Polypropylene fibres @ 0.90 Kg /cum to be laid in proper slope towards beam with minimum thickness of 50mm on horizontal suface and 15mm thick rich cement sand (1:4) plaster admixtured with integral water proofing compound on vertical surfaces all as specified and as directed by manufacturer and as directed by Engineer-in-Charge. Make- ECMAS
Taking down existing water proofing treatment of any description and in any position, not otherwise specifically provided for, any thickness above ground floor including cleaning of roof surfaces with wire brushes and removing debis out side MD land complete all as specified and directed by Engr-in-Charge.
Vishal Builders
Dimalson Decorator
M/S OMKARA INFRATECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .