Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹3.4 L+₹33,817 (11.0%)Rejected-Finance B 16 280 KALYANI KALYANI NEAR KALYANI MUNICIPALITY NADIA WEST BENGAL 741235 | NADIA | WEST BENGAL | 741235 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹4.5 L+₹1.4 L (47.1%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹6,150
Closing Date
12 Jan 2026, 10:55 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Annual maintenance estimate of the EI work at Lokpur Admin and Academic Building, MRD, Cardiology, Eye OPD allied non residential type building of BSMCH under BSMCH Electrical Section-III, PWDte for the year of 2024-25.------Dismantling , shifting an
2025_WBPWD_974888_1
WBPWDTE/AE/BMCESD/NIQ-31/Q of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹6,150
Yes
12 Feb 2026
15 Dec 2025
14 Jan 2026
15 Dec 2025
12 Jan 2026
2 Jan 2026
Amount
Dismentaling , Shifting & Re-installation, Testing, and Commissioning of 7.5 TR capacity concealed type Split Air Conditioner from OLD CCU to USG-11 Room. (i) No. of ODU- 01 Nos. (ii) Rated Cooling capacity of ODU: Upto 90,000 BTU / Hr. or Higher (iii) Rated Power Supply of ODU: 400V,50Hz, 3Ph. (iv) Compressor type- Twin Rotary/ Scroll (v) No. of IDU- 03 Nos.
Dismentaling , Shifting ,Installation , Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of suitable size bracket for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC.
SITC of 2.5 TR Compressor Split type AC Machine 7.5 TR machine (Make-Hitachi/Emerson)
Supply & laying of Suction line 5/8" Cu.Pipe With 9 mm thick Nitrile Insulation & Liquid Line 3/8" Cu. Pipe with 9 mm thick nitrile insulation for 7.5 Tr Concealed Split AC Machine
Supply and Laying Copper Control Cabling from Condensing Unit to control panel (Make:Gloster/ Polycab/Finolex) 4 core 2.5 sq.mm communication cable
Charges of Refrigerant R22
After commissioning the machine testing the leack by nitrogen gas pressure (minimum 400 PSI ) and vacuuming the unit properly (Minimum -30 PSI), hold the vacuum up to 48 hours, after release the gas testing the Ductable split type Air-conditioner Room Air conditioner.
Supply & laying Drain Water piping work by PVC / HDPE hard pipe of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors. (Make- Oriplast / Supreme) 25/32 mm dia
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (100 mm x 50 mm x 50 mm) and ( 50 mm x 50 mm 50 mm) for making platform for installation of outdoor unit of 7.5TR Ductable split AC incl. drilling 3 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle same .The entire structure should be baricaded & safe for ODU Maintenance . Area of the platform is 3Mtr. x 1.2Mtr. With space factor 0.8 or as per Machine configuration & load with adequate service access as per direction of EIC
REFRICON (BID ID -7819436)
CARRION AIR COOLING (BID ID -7817619)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .