| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹39.0 L+₹2.4 L (6.56%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹39.0 L+₹2.4 L (6.58%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹42.1 L+₹5.4 L (14.8%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹42.5 L+₹5.8 L (16.0%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
2 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
REPAIRS / MAINTENANCE OF WATER SUPPLY DISTRIBUTION SYSTEM AND ALLIED WORKS AT CENTRAL AREA UNDER AGE E/M-1 AT GE (CENTRAL) KHADKI.
2023_MES_604205_1
8844/E8 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CENTRAL area
AS PER NIT
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹98,000
Yes
15 Dec 2023
19 Jun 2023
4 Sept 2023
19 Jun 2023
2 Sept 2023
21 Aug 2023
19 Jun 2023 - 30 Jun 2023
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipes /cables etc and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for lying of pipes/cable etc and getting out in soft disintegrated rock/road cuttings complete all as specified and as directed.
Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers n . Exc 25 cm complete all as specified and directed.
Repairs, renewal of pipie lines and attending emergency water supply breakdown complaints within 6 hours on telephonic intimation/SMS by arranging JCB/Excavator for excavation,breaking footpath paved with PCC blocks,PCC flooring,bituminus road etc up to 4 mtrs depth,dewatering with suitable dewatering pump,cutting and removing defective pipes,lowering the required size of pipes,valves and fittings with the help of crane and welding works if any,refilling the trench after repair with excavated soil,relaying of removed PCC blocks and matching with sorroundings etc complete including PCC work as directed at site. NOTE :- (1) Materials required for the repairs such as pipes,fittings,valves,Mechanical joints, PCC,PCC blocks etc will be measured and paid under relevant item. (2) Items such as Rubber gaskets,Nuts,bolts, washers and lathe work required to bring the pipe line of required size etc are to be included in the quoted rate. (3) the contractor shall provide sufficient barricades,caution tape,danger boards etc at work site to avoid any accidents at site. (4) If the contractor fails to start the work within 6 hours on receipt of telephonic intimation /SMS , Necessary recovery will be made twice the quoted rates of respective items. (5) Compensation if any due to any accident at site to be borne by the contractor.
Material and labour for taking up cast iron water mains (incl all fitting) 80mm bore dia of pipe with spigot and socket ends from trenches complete all as psecified and directed.
Description all as item no.6 above but size of pipe 100 mm bore
Description all as item no.6 above but size of pipe 150 mm bore
Description all as item no.6 above but size of pipe 200 mm bore
Description all as item no.6 above but size of pipe 250 mm bore
Description Description all as item no.6 above but size of pipe 300 mm bore
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wDescription all/ on floor locations for 100 mm bore dia pipe complete all as specified and directed. MAKE :- Electrosteel/Jindal or its equivalent.
Description all as item no.12 above but 150 mm bore pipes.
Description all as item no12 above but 200 mm bore pipes.
Description all as item no.12 above but 250 mm bore pipes.
Description all as item no.12 above but 300 mm bore pipes.
Material and labour for cutting cast iron pipes in position for insertion of fittings, mechanical joints, replacement of pipes etc for bore of pipe 80mm complete all as specified and directed by Engineer-in-Charge.
Description all as item no.17 above but 100 bore pipes
Description all as item no.17 above but 150 bore pipes
Description all as item no.17 above but 200 bore pipes
Description all as item no.17 above but 250 bore pipes
Description all as item no.17 above but 300 bore pipes
Description all as item no.17 above but 450 bore pipes
Supply and fixin repair MS mechanical joint with rubber washer, mild steel screw bolts (machine made) with screwed both ends of dia as per flange hole and required length each screwed end to be fitted with washers and one hexagonal nut suitable for bore of pipe 80mm complete all as specified and as directed.
Description all as item no.24 above but 100 mm size.
Description all as item no.24 above but 150 mm size.
Description all as item no.24 above but 200 mm size.
Description all as item no.24 above but 250 mm size.
Description all as item no.24 above but 300 mm size.
Description all as item no.24 above but 450 mm size.
Material and labour for ductile iron fittings such as bends (any type, radius and angle), tapers any type (straight, bend, incresing, decreasing or double socket etc.), Tee piece, single branch 'Y'junction double branch, collar etc., caps and plugs etc. as per IS: 9523-2000 of class K-7, with internal cement mortor lining, and external zinc and black bitumen coated of dia upto 150 mm complete all as specified and directed.
Description all as per item No. 31 above but of dia exc 200 but n.exc 300mm complete all as specified and directed
Material and labour for laying, jointing and testing MS Pipe 300 mm bore, 8 mm thick externally coated with anti corrosive paint with welded joints laid in trenches in short lengths as required at site up to 4 mtr in depth including taking out defective pipes all as directed at site.
Description all as per item No. 33 above but for MS Pipe 450mm dia.
Material and labour for MS fittings such as bends (any type, radius and angle), tapers any type (straight, bend, incresing, decreasing or double socket etc.), Tee piece, single branch 'Y'junction double branch, collar, caps and plugs etc of 8mm thick externally coated with anti corrosive paint duly welding the joints internally and externally of dia upto 250 mm complete all as specified and directed
Description all as per item No. 35 above but of dia exc 250mm upto 450 mm .
Material and labour for taking up worn out GI steel tubing incl all fitings fron trenches of 15 mm bore complete all as specified and directed.
Description all as item no.37 above but 20 mm bore pipes.
Description all as item no.37 above but 25 mm bore pipes.
Description all as item no.37 above but 40 mm to 50 mm bore pipes.
Description all as item no.37 above but 80 mm bore pipes.
Description all as item no.37 above but 100 mm bore pipes.
Description all as item no.37 above but 150 mm bore pipes.
Material and labour for laying in trenches / fixed to wall galvanised steel water tubing 15 mm bore, medium grade with and including all medium grade fittings complete all as specified and directed. MAKE :-Tata/Jindal.
Description all as item no.44 above but 20 mm bore pipes.
Description all as item no.44 above but 25 mm bore pipes.
Description all as item no.44 above but 40 mm bore pipes.
Description all as item no.44 above but 50 mm bore pipes.
Description all as item no.44 above but 80 mm bore pipes.
Description all as item no.44 above but 100 mm bore pipes.
Description all as item no.44 above but 150 mm bore pipes.
Supply and fix in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and as directed. MAKE :- Zoloto/Leader .
Description all as item no.52 above but 20 mm bore
Description all as item no.52 above but 25 mm bore
Description all as item no.52 above but 40 mm bore
Description all as item no.52 above but 50 mm bore
Description all as item no.52 above but 65 mm bore
Supply and fix in repairs CI body non raising SS spindle sluice valve with cast iron wheel, of size 80 mm bore, class PN-1.6 with SS spindle with brass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc complete in position of pipe line all as specified and directed. Make; Kirloskar/Upadhaya
Description all as item no.58 above but 100 mm bore
Description all as item no.58 above but 150 mm bore
Description all as item no.58 above but 200 mm bore
Description all as item no.58 above but 250 mm bore
Description all as item no.58 above but 300 mm bore
Description all as item no.58 above but 450 mm bore
Supply and fix in repairs cast iron air release valves with twin globe air outlet,100 mm dia flanged including fittings as required at site, making necessary modification/ arrangements and on CI/MS/DI pipeline of bore up to 450 mm complete all as specified and directed. MAKE :- Normex/Kirloskar or its equivalent.
Supply and fix in repair extended valve operating device 1.0 mtr long with 25 mm GI Pipe heavy grade duly welded with spindle cap and handle as per sample complete all as specified and as directed. complete all as specified and directed by Engr-in-Charge.
Material and labour for spray painting of various pump set and old metal surface such as suction /delivery pipes, with 2 coats of synthetic enamel paint, marking arrows, writing letters etc including preparation of surface by rubbing and removing all dirt complete all as specified and directed.
Fabrication, supply and installation of glow sign boards of size not less than 6mtr x 1 mtr x 0.4 mtr made of ACP Panel sheet of 3mm thick with Blue background over 40' x 40' square tubes with verge letters made of acryclic sheet white in colour and having LED strip only on letters and MES Logo placed on angle iron frame duly welded of size 50X50X5.00 mm thick of height not less than 2 mtr including connecting service cable weather proof 4.00 sq mm 2 core from switch board upto 20 mtr including taking out perished sign boards of any type complete as per sample all as specified and directed by Engr-in-Charge. NOTE : Sample of glow sign board to be got approved by Engr-in-charge/GE before placing the order.
Supply and fix in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltrs complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair cast Iron swing check non return valve confirming to IS : 5312 (Part I) of 1969, both end flanged with rubber gasket & Nuts, bolts & washers of sizes 150 mm bore. Make : Normex/Kirloskar or its equivalent.
Description all as item no.70 above but 100 mm bore.
Supply and fix in repairs cast iron foot valve confirming to IS : 4038 flanged end with rubber gasket, Nuts, bolts & washers of sizes 150 mm bore. MAKE :- Normex/Kirloskar
Description all as item no.72 above but 100 mm bore
Description all as item no.72 above but 80 mm bore
Description all as item no.72 above but 65 mm bore
Material and labour for brick masonry valve pit chamber of internal dimension 120 cm x 100 cm x 90 cm depth with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping, with and including MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
Material and labour for angle iron frame and MS cover for valve chambers and duct covers., pump motor base frame of ISMB etc as per existing size and shape including two coat of painting over one coat of red oxide including dismantling of existing covers etc complete all as specified and directed by Engineer-in-Charge.
Material and labour cement concrete type B-2,1:2;4 ( 40 mm graded stone aggregate ) in sub base 75 mm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix 80 mm thick machine pressed precast concrete rubber moulded coloured interlocking paver block with coloured cement and pigment any shape and size confirming to IS-15658-2006 M-40 grade laid over 50 mm thick sand cushionining complete all as specified and directed by Engineer-in-Charge.
Supply and fix hot dipped galvanized chain link fencing with zinc coating, nominal height-2400mm, pitch-50mm and wire dia 3.15 mm. (approx weight-2.55 Kg /Sqm)
Material and labour for mild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts incl dismantling / taking down unsv one complete all as specified and directed.
Material and labour for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securingwith clips complete for support of chain link fencing incl dismentling taking down unsv one all as specified and directed.
Dismantling taking out complete pump of any type, capacity upto 20 HP of different models from foundation including dismentling suction and delivery pipe connection from pump , carrying to wksp & back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete including testing, commissioning all as specified and directed. NOTE :- 1. spares required for the repairs will be measured and paid under respective items . 2. Small items such as gaskets, Nuts,bolts and washers,screws, consumable like grease etc will be inclusive of quoted rates.
Supply only ball Bearing, (DE).
Supply only Ball Bearing (NDE).
Supply only Impeller.
Supply only Pump Shaft.
Supply only Lantern Ring.
Supply only Mechanical Seal.
Supply only Water Deflector.
Supply only Bush
Supply only Key Impeller.
Supply only Gland Packing.
Supply only Gasket set
Dismantling taking out induction motor upto 20 HP from foundation by removing electric connection, coupling carefully and carrying to wksp & back for repair complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning, proper alignment all as specified and directed.
Material and labour for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled coper wire, required binding, bonding, insulation, varnishing and drying and proper testing after rewinding for the following sizes of motor capacity upto 20 HP
Supply and fix in repair automatic Star delta starter for centrifugal pump set of capacity upto 20 HP conforming to IEC-60947-4-1 / IS-13947-4-1, 3 phase 415 volt 50 Hz with CRCA sheet steel enclosure complete with heavy duty 4 pole contactor with wide band operating coil, overload relay for motor protection and electronic star delta timer, single phase preventer, etc complete all as specified and directed by Engr-incharge. MAKE :- L&T/BCH
Material and labour calcium hypochlorite (65% to 70% chlorine content) calcium based granular disinfectant in 45 Kg Drum
Material and labour alum ferric Gde -I
Material and labour hydrated lime suitable for drinking water
Supply and fix in replacement MCCB 250 Amps type DTH -250 having breaking capacity 36 KA 415V 3 pole complete all as specified and as directed. MAKE :- L&T/Legrand
Supply and fix in replacement MCCB 200 Amps type DTH -200 having breaking capacity 25 KA 415V 3 pole complete all as specified and as directed. MAKE :- L&T/Legrand
Supply and fix in replacement MCCB 100 Amps type DTH -100 having breaking capacity 16 KA 415V 3 pole complete all as specified and as directed. MAKE :- L&T/Legrand
Supply and fix in replacement MCCB 63 Amps type DTH -63 having breaking capacity 10 KA 415V 3 pole complete all as specified and as directed. MAKE :- L&T/Legrand
Supply and fix in replacement MCB 63 Amps C Curve 415 volts 3 pole complete all as specified and as directed. MAKE :- L&T/Legrand
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/ MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured, heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, heavy duty cable served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size 16 Sqmm 4 Core. MAKE :- Polycab/KEI/Gloster /Havells
Description all as per item No. 107 here-in-before but 25 sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 107 here-in-before but 35 sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 107 here-in-before but 50 sqmm 3.5 core complete all as specified and directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 40 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Alcorr/ Rex/Gemini or its equivalent
Description all as per item No-111 above but of size 50mm outer dia
Description all as per item No-111 above but of size 63mm outer dia
Material and labour for 10 sqmm stranded copper conductor three phase alongwith copper lugs including connecting from pump set to starter complete all as specified and directed. MAKE :- Finolex/Polycab/Havells/KEI
Supply and fix in repair LT panel board factory made, indoor type dust and weather proof, fabricated with 3.00 mm CRCA sheet of suitable size confirming to IP 54 protection complete including Copper bus bar 150 Amps, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following: (a) Incoming MCCB 100 Amps 4 pole with microprocessor based release having breaking capacity 36 KA.....01 Nos. (b) On load change over switch of capacity 100 Amps - 01 No. (c) Outgoing MCB 63 Amps 415 V, Triple Pole, 36KA---03 Nos. (d) Outgoing Star Delta starter 20 HP - 03 Nos (e) Outgoing MCB SPN 40 AMps - 02 Nos. ( f) Digital Voltmeter 0-500 V 96x96xm …. 01 No (g) Digital Ammeter 0 - 500 A 96x96m …. 01 No (h) Indicating lamps set RYB …. 01 set. (j) Panel mounted type digital multifunctional energy meter, CT operated, LT 3 phase, 4 wire, including CT of suitable ration- 01 Nos
Supply and fix in repair LT panel board factory made, indoor type dust and weather proof, fabricated with 3.00 mm CRCA sheet of suitable size confirming to IP 54 protection complete including Copper bus bar 150 Amps, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following: (a) Incoming MCCB 100 Amps 4 pole with microprocessor based release having breaking capacity 36 KA.....01 Nos. (b) On load change over switch of capacity 100 Amps - 01 No. (c) Outgoing MCB 63 Amps 415 V, Triple Pole, 36KA---02 Nos. (d) Outgoing Star Delta starter 15 HP - 02 Nos (e) Outgoing MCB SPN 40 Amps - 02 Nos. ( f) Digital Voltmeter 0-500 V 96x96xm …. 01 No (g) Digital Ammeter 0 - 500 A 96x96m …. 01 No (h) Indicating lamps set RYB …. 01 set. (j) Panel mounted type digital multifunctional energy meter, CT operated, LT 3 phase, 4 wire, including CT of suitable ration- 01 Nos
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/clear water sumps of capacity UG sump 100000 gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: rays Cleantech/ Inus watertech/ satya enterprise. seven stages are as under :- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 . Contd to
Contd from,, NOTE:- (i) COMPANY WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXIi-60/NB-69, BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE.) (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE.
All as per ser item No 117 and 118 above but for UG sump of capacity 50000 gallons
All as per ser item No 117 and 118 above but for UG sump of capacity 20000 gallons
All as per ser item No 117 and 118 above but for UG sump of capacity 10000 gallons
All as per ser item No 117 and 118 above but for overhead reservoir capacity 10000 gallons
All as per ser item No 117 and 118 above but for overhead reservoir capacity 20000 gallons
All as per ser item No 117 and 118 above but for overhead reservoir of capacity 50000 gallons
All as per ser item No 117 and 118 above but for overhead reservoir capacity 100000 gallons
Chemical testing of water sample at PMC or at any govt recognised water testing lab for the following parameters: Turbidity, pH, Total Hardness, Alkalinity, Chloride, Nitrate, TDS, Iron, Flourides, calcium, Magnesium, Aluminium, Sulphide, Lead, Arsenic, Manganese, Copper, Mercury, residual chlorine complete all as specified and directed by Engineer-in-Charge. NOTE :- (i) Sample of water to be collected from pump houses in sterilised bottle provided by the lab (ii) Sample of water to be deposited to lab and report to be collected duly signed by authorised person of Lab, (iii) Cost of transportation of water sample and collection of report shall be inclusive of quoted rate, (iv) Cost of Testing as specified shall be paid to Lab directly by the Contractor and the cost shall be inclusive of quoted rate, (v) Testing shall be carried out in scheduled time, otherwise recovery shall be effected thrice the quoted rate, (vi) Complete parameter testing shall be considered as one job)
SKS Electricals
M/S kirpan Enterprises
JP ENTERPRISES
ONKAR ELECTRIC AND GENERAL STORE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .