Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹2.6 Cr Quoted ₹2.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.7 Cr+₹1.5 L (0.53%)Rejected-Finance 401 7 32 CIVIL LINES ROORKEE HARIDWAR UP 247 667 | ROORKEE | HARIDWAR | UP | 247667 | ₹2.7 Cr+₹1.5 L (0.53%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹2.7 Cr+₹1.8 L (0.66%)Rejected-Finance 77 28 WANOWRIE OPP HANDICAP SCHOOL PUNE 411 040 | PUNE | PUNE | MAHARASHTRA | 411040 | ₹2.7 Cr+₹1.8 L (0.66%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹2.8 Cr+₹5.4 L (1.99%)Rejected-Finance | ₹2.8 Cr+₹5.4 L (1.99%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹2.9 Cr+₹21.6 L (7.92%)Rejected-Finance | ₹2.9 Cr+₹21.6 L (7.92%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
11 May 2021, 6:00 pmClosed
Chief Engineer Pune Zone Dakshin Kaman Marg Camp
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
ADDN/ ALTN AND SPECIAL REPAIRS TO MD ACCN OF JCOS AND ORS UNDER GE (SOUTH) PUNE
2021_MES_431802_1
84504E8
Open Tender
Civil Works
Item Rate
540 days
GE SOUTH PUNE
CLASS A CATEGORY a i
7 documents required · 7 mandatory
₹2,000
GE (South) Pune
₹4.1 L
Yes
31 May 2021
19 Mar 2021
13 May 2021
19 Mar 2021
11 May 2021
27 Apr 2021
20 Mar 2021 - 10 Apr 2021
Amount
Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in cement mortar, as in floors, hard standing , Aprons etc complete all as specified & directed.
Dismantling ceiling / boarding of any description, fixed in any position like ceiling, partition etc with nails including frame work of timber complete all as specified & directed.
Taking down chowkats or frames wooden/steel with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specifed and directed.
Taking down chowkats or frames wooden/steel with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specifed and directed.
Taking down shutter of any description not exceeding 1.00 Sqm each complete all as specifed and directed.
Taking down shutter of any description exceeding 1.00 Sqm and not exceeding 2.00 sqm each complete all as specifed and directed.
Demolition of brick work or PCC block masonry or stone/boulder masonry, built in cement mortar complete all as specified & directed.
Taking down cement plaster on brick/ block walling including racking out joints, hacking for key, scrubbing down with water etc complete all as specifed and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15cm thick (below or above ground level) unreinforced all as specified and as directed.
Dismantling of single layer Mangalore Pattern roof tile laid dry complete all as specified and directed
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spacing exceeding 15 cm complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete
Dismantling timber fillets in framed work , rails, posts, rafters, purlins, etc under 40 sqcm in section complete all as specified and directed.
Dismantling Plain or Corrugated Steel Sheeting of any gauge or similar pattern Roof Coverings complete all as specified and directed.
Dismantling of structural steel work including doors,gates but excluding framed Truss etc complete all as specified and as dircted.
Dismantling existing water tanks 250 lit/ 500 lit/1000 ltr capacity and removing to store complete all as specified and as directed.
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of size 15mm bore complete all as specifed and directed.
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of size 20mm bore complete all as specifed and directed.
Dismantling of CI / AC/ PVC pipes of various dia jointed in CM or adhesive 75 to 100mm dia all as specified and as directed.
Demolition of cement concrete of any description in any position etc un reinforced complete all as specifed and as directed.
M&L for coloured Non skid ceramic tiles, 7 to 8mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for non skid ceramic Coloured tiles, 300mmx300mmx7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in leveling course to floor tiles complete all as specified & directed
M & L glazed colour ceramic tiles of size 300mm x 450mm x7 to 8mm thick in dado/skirting, laid over and including 10 mm thick Cement Mortar (1:4) backing coat , set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles etc complete all as spcecified and directed.
M & L for Kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar, laid over and including 10mm thick cement plaster in cement mortar 1:4 as in backing coat and jointed in grey cement to match complete all as specified and directed.
M&L for 18 to 20mm thick Granite (of any type/colour) work (table rubbed and polished) in steps, pillars;window cills/jamb, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. as counters of any radius etc laid over and including 15mm thick screed bed in Cement Mortar (1:6) complete all as spcecified and directed.
Labour only for chamfering splays or arries in face work not exceeding 15mm wide, thickness of granite stone slab 18 to 20mm complete all as specifed and directed.
M&L for 20-25mm thick machine cut cudappah stone slabs, fixed independently in shelves for cooking platform and the like etc complete all as specified and as directed.
S&F in repair 18 mm thick prelaminated particle board interior grade, Conforming to IS-12823, Gde-I, prelaminated both side with decorative choice lamination as in Kitchen Cabinet etc, fixed with screw including 3mm thick, 1st Class HW (TW) beading all around on edging to timber frame work all as specified and directed.
S&F in repairs 40 mm dia polished hardwood cupboard Knobs fixed with nuts, screws and washer of brass polished all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (When open) is 30 mm, all as specified and as directed.
S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed
M & L for 12 mm thick mineral fibre false ceiling tiles on and including GI powder coated grid work of size 605 mm X 605 mm with using 26.5 mmX 23.5 mm X 1.5 mm angle fixed to wall for false ceiling including necessary supporting hanger with 3.0 mm dia GI wire and 'J' bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, size of grid shall be 605 mm X 605 mm complete all as specified and as directed. Make/ Manufacturer: Armstrong / Anutone / Anchor
S&F solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening all as specified and directed.
S&F three track sliding window with two shutters with 4mm thick sheet glass and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F, fixed glass ventilators using 5mm thick plain glass and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed. (a) SP - 20048 (b) Glazing clips - 19352. complete all as specified and directed.
S & F butt hinges 100mm size MS cold rolled medium weight all as specified.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified & directed.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 300 mm complete all as specified & directed.
S&F in repair, aluminium handles, fabricated type, of size 150 mm complete all as specified & directed.
Removing of old water proofing treatment and cleaning the surface of slab and cleaning with wire brushes, removing dust, foreign material, rubbish off the site to a distance not exceeding 500m complete all as specified and directed.
M & L Water proofing treatment to RCC roof slab shall be carried out as specified below and as directed by Engineer-in-Charge .(a) M&L for 10mm thick screed bed in cement mortar 1:3 on concrete surfaces of roof slab and parapets mixed with WPC @ 3% by weight of cement finished even and smooth without using extra cement (b) The roof surface shall be thoroughly wire brushed, cleaned to eleminate all sharp projection washed dried up and cleaned of all foreign matter and dust to receive primer.(c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE.(d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge.(e) The overlap while Torching shall be 100 mm on length side and 100 mm on width side of membrane.(f) The treatment shall be carried as per manufacturer instructions.Note:- The contractor shall furnish the following :- I) Quality confirmation from the manufacturer of the product alongwith quantity supplied.ii) Manufacturer test certificate.iii) The result if tested any of the independent laboratory, the testing charges shall however be borne by the Contractor.
Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning etc and hoisting if required, reconnecting and refixing in position exceeding 500 Ltr but not exceeding 1000 ltr Complete all as specified and as directed
M&L PCC 1:4:8, type D2, using 40 mm graded aggregate, 75 mm thick as in sub floor, Sub base, floor, including finishing the surfaces even and fair complete all as specified & directed.
M&L for PCC 1:2:4 Type B-1 (using 20 mm graded stone aggregates) as in 40 mm thick floor, finishing the surface even and smooth without using extra cement, complete all as specified & directed.
S&F glass dividing strips, 3mm thick and 38 mm wide, inserted in position, complete all as specified & directed.
M&L for 100 mm thick PCC 1:2:4 Type B-1, using 20 mm graded stone aggregate as in PCC path and paving, surface finished even and fair without using extra cement and making impressions of expended metal, whilist concrete is green, complete all as specified & directed.
M&L PCC 1:3:6, Type C-2 using (40mm graded stone aggregates) 75mm thick, finished even and smooth without using extra cement as in plinth protection, PCC path, complete all as specified & directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick in floors, set, jointed and pointed in neat cement slurry with grey cement and pigment, laid over and including 15mm thick screed bed in Cement Mortar (1:6) complete all as specified & directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in Cement Mortar (1:6) complete all as specified & directed.
M&L for rendering 10mm thick in cement mortar 1:6 on concrete surfaces finished even and smooth with sagol finish complete all as specified & directed.
M & L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work/ stone surface and finishing even and smooth without using cement with sponge finish all as specified and as directed.
M & L for rendering 5mm thick in cement mortar 1:3 on concrete surface, finished even and smooth with a thin layer of sagol as in ceiling all as specified and as directed.
M & L for preparation of new plastered surfaces of walls & applying two coats of weather proof anti fungal, anti algae acrylic emulsion paint which gives 3 year of performance warranty (Make as specified in Appendix 'C') complete all as specified & directed.
M & L for preparing newly plastered surfaces of walls and applying two coats of Acrylic emulsion distemper over a coat of alkali resistant primer complete all as specified & directed.
M & L for preparing newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified & directed.
M&L for prepration of old painted wooden surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for scrapping and removing old paint, lease material and algae fungus then cleaning of surface with water using pressure washer machine, then crack filling with acrylic based textured crack filler and application of one coat of primero primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio 5:4:1 followed by application of two coats of weather proof , anti fungle, anti algea acrylic emulsion paint of approved shade having silicon additives in paint which gives 3 year of performance warranty (Make as specified in Appendix 'C') complete all as specified & directed.
Complete removal of existing treatment on wall and applying two coat of Acrylic emulsion destemper over a coat of alkali resistant primer on wall complete all as speficied and as directed.
Prepration of old decorated surfaces of ceiling by brooming down and scrapping wherever necessary and applying one coat of white wash complete all as specified and directed.
S&F in repairs towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden /plastic cleats complete all as specified and as directed.
S&F roof sheeting prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F plain sheeting prepainted galvalume aluminium zinc coating GI based steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering / ridge/Valley gutter ll, fixed with self tapping screws complete all as specified and directed.
M&L for MS structural steel work, framed as in trusses, purlins, rafter, post etc. confirming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plat, gusset plate and also erecting in true position complete all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming Fe 410 -W (Gde- E- 250) quality- A, all as specified and as directed.
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290.Gde-E-165, all as specified and as directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetics enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F in repairs, cast iron Nahani trap with grating of diameter of outlet 75mm including jointing to waste pipe fixed including provision of cement concrete type B1 (1:2:4). complete all as specified and directed.
S&F PVC SWR gully trap 125/110mm setting and jointing with solvent cement complete all as specified and directed.
Supply and fixed double layer embosed ISI marked and manufacturer name approved make rotational moulded polyetylene water storage tanks (cylindrical vertical with closed top) of 500 Litres capacity, hoisted and fixed in position all as specified in SSR Part 1 (2009) and connecting up pipes securing access covers incl 20 mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc including dismantling old water tanks and removing to store, all as specified and directed.
S&F 15mm dia bore GI tubing medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. complete all as specifed and directed.
S&F 20mm dia bore GI tubing medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc. complete all as specifed and directed.
Refixing old steel water tubing and connections of 15mm dia bore in new or old position ( walls, ceiling , floors etc) complete all as specifed and directed.
Refixing old steel water tubing and connections of 20mm dia bore in new or old position ( walls, ceiling , floors etc) complete all as specifed and directed.
M&L for cutting chases, pinning in brick work, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
S&F 110 mm UPVC SWR pipes single socketed in any length with rubber ring joints fixed to wall including clamp etc complete all as specifed and directed.
S&F 75 mm UPVC SWR pipes single socketed in any length with rubber ring joints fixed to wall/Floor including clamp etc complete all as specifed and directed.
S&F UPVC (SWR) bends plain 110 mm bore complete all as specifed and directed.
S&F UPVC(SWR) bends plain 75mm bore complete all as specifed and directed.
S&F in repairs vitreous china, squatting pan, 'Orissa' pattern, size 580 x 440mm white of first quality with integral foot rest, including concrete bedding and PVC flushing cistern 10 Ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
S & F in repair for Wash Hand basins, Vitreous China, white, flat back, size 550x400mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed.
S&F in repairs, pillars tap CP 15mm dia, cast copper alloy with capstan head, screwed down high pressure with long screwed shanks and flynuts screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repairs shower rose bass chromium plated 125 mm dia with swivel joints type, screwed for 15mm bore including jointing to pipe or unions complete all as specifed and directed.
S&F in repairs stainless steel sink with drainage board made of stainless steel 1 mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size not less than 915mm x 460mm and bowl size not less than 405mm x 355mm x178mm, complete all as specified and as directed.
S&F in repairs stainless steel sink, 1 mm thick for kitchen or laboratory, with plugs, waste pipe, washers; including bedding in cement mortar on to dwarf wall or including fixing cantilever CI Brackets, connecting union etc & connecting to inlet/out let for smooth functioning, size of sink not less than 495 x 420mm overall and bowl size not less than 405mmx355mmx178mm, including PVC connection, CP waste coupling, etc. complete all as specified and as directed.
S&F looking mirror of size 600 x 450mm approved quality and make, mounted on 6 mm thick plywood commercial as backing and aluminium powder coated frame all around on edges all as specified and as directed.
S&F in repairs fancy type bib taps of cast copper alloys chromium plated with capstan heads screwed down screwed for iron pipe or for brass ferrule and fixed for 15mm dia pipe complete all as specified and as directed.
S&F aluminium powder coated fancy type curtain rod 20mm bore all as specified & directed.
S & F aluminium powder coated brackets suitable for 20mm dia curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed.
S&F in repairs stop valve 15mm dia, cast copper alloy chromium plated screwed down high pressure with capstan head screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and as directed.
S&F in repairs stop valve of 15 mm dia cast copper alloy chromium plated, with long shank and cup consealed type secrewed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs stainless steel plate rack of size 36inch x 31inch x 10inch, made out of 0.63mm thick stainless steel sheet (Grade AISI 304 18/8), S S screws and round pipe, fixed to wall with screws complete all as specified and as directed. Make– Blue Star Silver Shine Cat No.SSKPR-315 or equivalent in any make listed in Appendix 'C' complete all as specified and as directed.
S & F for pressed steel door frames of size 105x60mm and 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filling of hollow portion with PCC 1:3:6 type C-1 using 20mm graded coare stone aggregates complete, as specified, supplied and fixed all as specified and directedh all as specified and as directed complete.
S & F for pressed steel door frames of size 125x60mm and 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including filling of hollow portion with PCC 1:3:6 type C-1 using 20mm graded coare stone aggregates complete, as specified, supplied and fixed all as specified and directedh all as specified and as directed complete.
S&F flush door shutters, 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides including 6mm thick Ist class Hard Wood (Teak) beading complete all as specified and directed.
S & F 35mm thick glazed and skeleton shutter in 2nd class hardwood, open rebated and prepared to receive glass,gauge,etc.(without sash bars), edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass,etc; The size of the members of shutters as specified in SSR Part-I, Section 8, clause No 8.24(a), Kiln seasoned and chemically pressure treated all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of M.S tubes for top & bottom rails; M.S frame shall be covered with heat moulded plain colour PVC ‘C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supply and fixing in frame at site as per specification& drawing, all as specified and directed.
M&L for preparation of new wooden surfaces over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and labour for sunken flooring as per following details :-
(a) Special treatment to toilet floor by demolition of existing treatment of any description and thickness, removal rubbish outside MD land.
(b) Clean the sunken portion of toilet / Bath / WC / Kitchen throughly to remove laitance, dirt dust, etc.
(c) Form angle fillet of size 40mm x 40mm along the junction of wall and floor using polymer modified mortar ("Dr Fixit" Pidicrete URP" or equivalent Make as given in Appx 'C')
(d) Sanitary pipes entering through walls and floor shall be sealed with "Dr Fixit Bathseal Tape " or equivalent Make as given in Appx 'C' and the gaps to be grouted with non-shrink cementitous grout "Dr Fixit Bathseal Grout" or equivalent Make as given in Appx 'C' Nahani Traps, etc to be fitted securely and the gaps around it to be grouted in the same manner.
(e) Apply one coat of a Bitumen-modified polymer coating "Dr Fixit Bathseal Plus" or equivalent Make as given in Appx 'C' on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.
(f) In the remaining area, in dry sustrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing coating "Dr Fixit Pidifin 2K" or equivalent Make as given in Appx 'C', can be further applied right upto 2.10 mm to water proof the shower area also, it is a bathroom or bath cubicles of a sanitary annes and apply second coat after 6-8 hours and allow to dry completely.
(g) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed M-15 type B0 mixed with intergral WPC (Liquid) laid to be slope 1:60 towards outer face of wall. including provision of 40mm OD UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2 etc complete all as per manufacturers instruction and direction.
Taking down carefully existing unserviceable aluminium/copper point wiring (light, fan, socket or power), complete (fitting such as switches, ceiling rose, pendent, regulators etc) removing material from site and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed.
Taking down carefully submain wiring of any description any type and any size complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in any type of wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick,60mm deep, with earth dollyduly, covered with hylam sheet top cover 3mm thick,ISI marked suitable for fixing switches , fan regulators and sockets, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for One light point controlled by one, one way switch 5 Amps.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in any type of wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick,60mm deep, with earth dollyduly, covered with hylam sheet top cover 3mm thick,ISI marked suitable for fixing switches , fan regulators and sockets, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amps.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in any type of wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick,60mm deep, with earth dollyduly, covered with hylam sheet top cover 3mm thick,ISI marked suitable for fixing switches , fan regulators and sockets, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in any type of wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick,60mm deep, with earth dollyduly, covered with hylam sheet top cover 3mm thick,ISI marked suitable for fixing switches , fan regulators and sockets, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in any type of wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick,60mm deep, with earth dollyduly, covered with hylam sheet top cover 3mm thick,ISI marked suitable for fixing switches , fan regulators and sockets, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for One light point controlled by two, two way switchs.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in any type of wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick,60mm deep, with earth dollyduly, covered with hylam sheet top cover 3mm thick,ISI marked suitable for fixing switches , fan regulators and sockets, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for One bell point controlled by one, bell switch 5 Amps.
All as per item No 115 above but with stranded copper conductor 2.5 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet on independent board including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6.0 Sqmm nominal area and drawing into PVC non metallic rigid PVC concealed conduit in any type of wall/ ceiling including one run of PVC insulated 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed incl taking down old unserviceable sub main of any description complete all as specified and as directed. Note:- Three runs of cables and one run of PVC conduit will be measured as one unit.
S&F Switch piano, flush type single pole, one way 6 Amp complete all as specified and as directed.
S & F for celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified.
S&F socket outlet 2 in 1, 3 pin, 5 /15 Amp flush type complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 15 Amp complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amp complete all as specified and as directed.
S&F Switch piano, flush type,single pole, two way 5/6 Amp complete all as specified and as directed.
S & F for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten/ slanting fittings with 10 watts LED bulb, complete all as specified.
S&F bell push, flush type, 5 Amp complete all as specified and as directed.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed
S & F ceiling fan regulator socketed, step type, flush type, heavy duty suitable to work on 230 Volts AC supply complete all as specified and as directed.
S&F IP-54, IK 09, protection metal double door vertical TPN -DB , rated bus bar 415 V, 50 Hz, complete with interconnection links, blanking plates, cable ties, identification labels TPN 8 ways, 24 modules suitable for accomodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as outgoing and concealed in wall including all cutting holes in or through walls , ceiling etc including two coats of white /colour washing/distempering etc to the disturbed surfaces to match the existing, all as specified and directed. Cat No 5077 52 of Legrand or equivalent in make as given in Appendix 'C'.
S & F MCCB 100 Amps, 25KA, 4 Pole, 415Volts, electronic protection complete all as specified and as direcrted. Unit model of Legrand Cat No 4203 15 or equivalent in make as given in Appendix 'C'.
S & F by flushing to walls MCB distribution board SPN 240 volts 12 way double door with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incl taking down old unserviceable MCB DB of any description complete all as specified and as directed.
S & F by flushing to walls MCB distribution board SPN 240 volts 8 way double door with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incl taking down old unserviceable MCB DB of any description complete all as specified and as directed.
S & F MCB SPN 40 Amps 240 volt breaking capacity 10 KA complete all as specified and as directed.
S & F MCB SP 6 to 32 amps 240 volt breaking capacity 10 KA complete all as specified and as directed.
Supply and fix wall mounted LED 25 watts, IVORA LED batten for surface, anodised extruded alluminium housing, high transmissitivity diffuser and high lumen output, 230 volts etc. complete with all accessories internally pre wired and necessary mounting arrangement, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make bajaj cat No 830258 or equivalent in make as given in Appendix 'C'. .
Supply and fix energy saving new generation 10 watts LED bulk head fitting IP65 luminaire with opel diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removalof old existing unserviceable tube light fitting complete all as specified and as directed. Make bajaj cat No BIBWP 10W or equivalent in make as given in Appendix 'C'.
Supply and fix LED 10 watt batten aluminium extruded with decorative end caps including removal of old unserviceable T-8 type light fitting complete all as specified and as directed. Make bajaj cat No BCLSB 10 WH or equivalent in make as given in Appendix 'C'.
Supply and fix energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 Watts with prewired and necessary mounting arrangment and provision of 2.5Sqmm three core copper conductor cable multistranded from ceiling rose to light fittings including necessary GI pipe medium grade bracket 600mm long bent to required shape and including taking down old unserviceable existing light fitting of any description complete all as directed by Engineer -in-Charge. Make bajaj cat No BCLST 25W LED I or equivalent in make as given in Appendix 'C'.
S & F for plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. Make -Bajaj Cat Part No - 70049 MAXIMA DX BLACK or its equivalent in approved make given in Appx 'C'.
M&L for cutting and making hole into or through cement concrete or stone masonery wall of thickness upto 45 cm and in girth 45 cm for fixing exhaust fan of size 250mm sweep & providing fasterner grouted in wall four nos inside for fixing of exhaust fan and four nos outside for louvers and redressing the surface and making smooth with cement plaster 1:4 to match existing surface incl lime white wash all as spd and directed all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3, SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection and 20 mm dia medium grade GI pipe for watering purpose inlcuding funnel, wire mesh, RCC pit with cover including excavation/earth work in any strata complete and connected to earthing test point all as specified or indicated including testing on completion.
M & L for earth continuity conductor or main earth lead fixed to walls, or burried in ground or drawn in GI pipe 4.0 mm dia GI wire all as specified and as directed.
Taking up carefully steel tubing and connections of any type and size (except 15mm & 20mm) including cleaning for refixing or removal complete all as specifed and directed.
Supply, laying in trenches and jointing Galvanised steel water tubings 40mm dia, medium grade, ISI Marked conforming to IS-1239, in any lengths with screwed and socket joints, together with and including all galvanised steel fittings such as sockets, elbows, bends, tees reducers, unions caps plugs, nipples, short pieces etc all as specified and directed.
S&F stop valve 40mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F Reinforced cement concrete pipe of bore dia 150 mm, class NP2,with one coller per length of pipe, half round (02 Nos for top and bottom) as in protection to LT cable laid in trenches complete all as specified and directed.
Supply, laying, testing and commissionnig of UG LT cables of size 35 sqmm x 3½ core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/DB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete including taking down old cable of any type and size complete all as specified and as directed.
Supply & lay GI tubing light grade ISI marked 50mm dia bore for cable protection/GI strip/GI wire protection in UG trenches/ road crossing /floor /wall /on poles or at any indicated situation etc duly sealed at both end with hession cloth impregnated with bituminous compound in ground and with teak wood bushes for ends after drawing cable including necessary clamps, saddles all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes, laying of pipes and cables etc not exceeding 10 sqm on plan and getting out in soft/loose soil all as specifed and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes,laying of pipes and cables etc not exceeding 10 sqm on plan and getting out in hard/dense soil all as specifed and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells, manholes, pier holes, laying of pipes and cables etc not exceeding 10 sqm on plan and getting out in soft and disintegrated rock all as specifed and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soft/disintegrated rock complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m from the starting point complete all as specified & directed.
KHANDELWAL ASSOCIATES
Khanuja Industries
Suma Construction
pal construction
United Sales Corporation
KARNI BUILDERS
L.K.R.TIWARI CONSTRUCTION
agarwal and company
N. H. Saluji & Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .