Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 LAccepted-AOC | L-1 | Accepted-AOC rate is genuine and covered requirement | |
| 2 | L-II.₹1.5 LRejected-Finance Q NO 2202 SEC 4E BOKARO | BOKARO | JHARKHAND | 825102 | L-II. | Rejected-Finance RATE IS HIGHER | |
| 3 | L-III₹1.5 LRejected-Finance | L-III | Rejected-Finance RATE IS HIGHER |
Tender Value
Refer Docs
EMD Value
₹2,998
Closing Date
26 Feb 2021, 4:00 pmClosed
DIGP (Ops) Range Bokaro
O/O DIGP (Ops) Bokaro Range, QTR No. 797, Sec 1/C Bokaro
Repairing renovation of 02 Nos office toilets cum Bath Room
2021_CRPF_616619_1
L.VII-1/2020-21-Q(1)
Limited
Construction Works
Works
30 days
O/O DIGP(OPS) BOKARO RANGE CRPF BOKARO JHARKHAND
Please refer Tender documents.
15 documents required · 15 mandatory
₹200
Yes
DIGP (OPS) CRPF , BOKARO
₹2,998
Yes
6 Mar 2021
15 Feb 2021
27 Feb 2021
15 Feb 2021
26 Feb 2021
16 Feb 2021
REPAIRING OF 2 NOS TOILET CUM BATH ROOM SIZE (8’5’’X 5’4’’) & SIZE( 10’6’’X5’6’’)
DSR No. 2018 (14.75) Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
DSR No. 2018 (15.23) Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.2 For thickness of tiles above 25 mm and up to 40 mm
DSR No. 2018 (11.41) Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.4 Size of Tile 1000x1000 mm
DSR No. 2018 (8.31) Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
DSR No. 2018 (13.80) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
DSR No. 2018 (13.90) Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : 13.90.1 Old work (one or more coats)
DSR No. 2018 (17.7) Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
DSR No. 2018 (12.50) 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
DSR No. 2018 (17.32) Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.4 Rectangular shape 1500x450 mm
DSR No. 2018 (15.52) Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
DSR No. 2018 (17.19) Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 17.19.1 10 litre (full flush) capacity-white
DSR No. 2018 (14.82) Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge
DSR No. 2018 (17.15) Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.
DSR No. 2018 (17.4) Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern
DSR No. 2018 (15.12) Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. metres
DSR No. 2018 (10.5) Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces
DSR No. 2018 (14.90) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 14.90.1 3 mm thick
DSR No. 2018 (18.9) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work ;- DSR No. 2018 (18.103) i) 25 mm dia nominal bore
DSR No. 2018 (18.104) ii) 32 mm dia nominal bore
DSR No. 2018 (18.22) Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.22.2 150 mm diameter
DSR No. 2018 (18.15) Providing and fixing brass bib cock of approved quality : 18.15.1 15 mm nominal bore
DSR No. 2018 (18.56) Providing and fixing PTMT pillar cock of approved quality and colour. 18.56.2 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms
DSR No. 2018 (17.73) Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
R. S. Construction and Communication
KAVITA CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .