Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.5 LAccepted-AOC | ₹16.5 L Quoted ₹1.4 L | 1 | Accepted-AOC L-1 bidder |
| 2 | 2₹15.6 L+₹14.2 L (1016.1%)Rejected-AOC VPO BARWA NEAR DO JHANTI DHAM STADIUM ROAD VPO BARWA 127045 | BARWA | BHIWANI | HARYANA | 127045 | ₹15.6 L+₹14.2 L (1016.1%) | 2 | Rejected-AOC L-2 bidder |
| 3 | 3₹23.4 L+₹22.0 L (1570.3%)Rejected-AOC G 6 RNS TOWER NEAR KADMA POLICE STATION KADMA JAMSHEDPUR EAST SINGHBHUM JHARKHAND 831005 | EAST SINGHBUM | JHARKHAND | 831005 | ₹23.4 L+₹22.0 L (1570.3%) | 3 | Rejected-AOC L-3 bidder |
| 4 | Rejected-Technical 2 3 OLD MANDI ROAD HISAR HARYANA 125001 | HISAR | HISAR | HARYANA | 125001 | - | - | Rejected-Technical Disqualified as the firm is not fulfill the PQR of NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified as the firm is not fulfill the PQR of NIT |
| Sl No | Description | Qty | Unit | NEWTECH ELECTRONICS L1 | INDUSTRIAL CONTROL SOLUTIONS L3 | Pri-Power Enterprise L2 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation, testing and commissioning of Electrical distribution panels at RGTPP Residential Colony, Khedar, Hisar Note: 1. Evaluation of tender i.e. L1,L2,L3…etc. bidders will be based on overall total rates quoted by the bidder in rate quoting sheet. 2. The work as a whole will be allotted to a single firm whose overall quoted/equated prices are lowest for the complete work. 3. Read scope of work and visit site before quoting the rate. 4. The quoted rate should be inclusive of all taxes except GST. 5. GST will be paid extra as per applicable rates against the documents proof. | ||||||
| 1.01 | Outdoor double-door panel for VIP guest house with 400 A incoming and 2 outgoing 200A feeders, along with a changeover switch. Panel size: 1450LX1700HX600D MM +300MM stand. | 1 | nos | 1,49,000 ₹1,49,000 Lowest | 2,39,874 ₹2,39,874 | 1,64,000 ₹1,64,000 |
| 1.02 | Indoor wall-mounted distribution panel for a community centre with 250A incoming and 2 outgoing feeders of 160A & 125A each. Panel Size:1652LX1650HX300DMM | 1 | nos | 1,14,000 ₹1,14,000 Lowest | 1,83,867 ₹1,83,867 | 1,42,000 ₹1,42,000 |
| 1.03 | Indoor wall-mounted distribution panel for the field hostel with 400A incoming and 2 outgoing feeders of 200A & 160A each. Panel Size:1652LX1650HX300DMM | 1 | nos | 1,45,000 ₹1,45,000 Lowest | 1,83,033 ₹1,83,033 | 1,57,000 ₹1,57,000 |
| 1.04 | Metering panel for a Type-2 residential building with 200A oncoming & space for 16 single-phase energy meters. Panel Size: 1800LX1950H X400DMM | 3 | nos | 90,000 ₹2,70,000 Lowest | 1,19,821 ₹3,59,463 | 1,06,000 ₹3,18,000 |
| 1.05 | Indoor main distribution panel of a Type-2 residential building with 400A incoming and 8 outgoing feeders of 200A each. Panel Size: 1800Lx1575Hx400D MM | 1 | nos | 2,13,000 ₹2,13,000 Lowest | 3,48,658 ₹3,48,658 | 2,15,000 ₹2,15,000 |
| 1.06 | Outdoor double-door panel for staff club & rest house & main meter panel for Type 5&6 with 400 A incoming and 5 outgoing 160A feeders. Panel size: 1500LX1750HX500D MM. | 3 | nos | 1,54,000 ₹4,62,000 Lowest | 2,76,887 ₹8,30,661 | 1,71,600 ₹5,14,800 |
| 1.07 | Outdoor double-door panel for football ground with 100 A incoming and 4 outgoing 63A feeders. Panel size: 700L X900HX300D MM | 1 | nos | 47,000 ₹47,000 Lowest | 1,92,924 ₹1,92,924 | 51,800 ₹51,800 |
Tender Value
Refer Docs
EMD Value
₹34,100
Closing Date
24 Mar 2026, 3:00 pmClosed
Chand Singh
CE RGTPP Khedar Hisar
Supply, Installation, testing and commissioning of Electrical distribution panels at RGTPP Residential Colony, Khedar, Hisar.
2026_HBC_504656_1
20266FE09902 DAF2 4F4E 8E12 6E551D32DC82712PGC
Open Tender
Electrical Works
Works
120 days
KHEDAR
2 documents required · 2 mandatory
₹1,180
₹34,100
Yes
15 Jun 2026
24 Feb 2026
27 Mar 2026
24 Feb 2026
24 Mar 2026
24 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, testing and commissioning of Electrical distribution panels at RGTPP Residential Colony, Khedar, Hisar Note: 1. Evaluation of tender i.e. L1,L2,L3…etc. bidders will be based on overall total rates quoted by the bidder in rate quoting sheet. 2. The work as a whole will be allotted to a single firm whose overall quoted/equated prices are lowest for the complete work. 3. Read scope of work and visit site before quoting the rate. 4. The quoted rate should be inclusive of all taxes except GST. 5. GST will be paid extra as per applicable rates against the documents proof. | |||||
| 1.01 | Outdoor double-door panel for VIP guest house with 400 A incoming and 2 outgoing 200A feeders, along with a changeover switch. Panel size: 1450LX1700HX600D MM +300MM stand. | 1 | nos | - | - |
| 1.02 | Indoor wall-mounted distribution panel for a community centre with 250A incoming and 2 outgoing feeders of 160A & 125A each. Panel Size:1652LX1650HX300DMM | 1 | nos | 1 | ₹1 |
| 1.03 | Indoor wall-mounted distribution panel for the field hostel with 400A incoming and 2 outgoing feeders of 200A & 160A each. Panel Size:1652LX1650HX300DMM | 1 | nos | 1 | ₹1 |
| 1.04 | Metering panel for a Type-2 residential building with 200A oncoming & space for 16 single-phase energy meters. Panel Size: 1800LX1950H X400DMM | 3 | nos | 1 | ₹3 |
| 1.05 | Indoor main distribution panel of a Type-2 residential building with 400A incoming and 8 outgoing feeders of 200A each. Panel Size: 1800Lx1575Hx400D MM | 1 | nos | 1 | ₹1 |
| 1.06 | Outdoor double-door panel for staff club & rest house & main meter panel for Type 5&6 with 400 A incoming and 5 outgoing 160A feeders. Panel size: 1500LX1750HX500D MM. | 3 | nos | - | - |
| 1.07 | Outdoor double-door panel for football ground with 100 A incoming and 4 outgoing 63A feeders. Panel size: 700L X900HX300D MM | 1 | nos | 1 | ₹1 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_583375.xls
BOQ • 0.37 MB
corrigendum-II.pdf
PDF • 0.33 MB
Corrigendum-I.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .